Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

11 micrometer emissivities and droplet radii for marine stratocumulus

The results of a new multispectral infrared retrieval scheme for obtaining fractional cloud cover and 11 micrometer emissivity with those of the spatial coherence method which obtains fractional cloud cover assuming that the clouds are opaque at infrared wavelengths. Both methods are applied to 4-km NOAA advanced very high resolution radiometer global area coverage data for 250-km-scale regions containing single-layered marine stratocumulus off the coast of South America. The average 11 micrometer emissivity for low level clouds is found to be between 0.70 and 0.85. The low emissivity is evidently due to the thinning of clouds at their edges. Semitransparent cloud edges evidently make up a substantial portion of the area covered by such clouds. This result indicates that cloud cover obtained using the spatial coherence method is underestimated by 0.1 to 0.2, as has been claimed in a previous study. The fractional cloud cover for the ensemble of 250-km-scale regions studied here increased slightly from 0.60 for daytime observations to 0.63 for nighttime observations. The 11 micrometer emissivity also increased slightly, but about half of the increase was related to the increase in cloud cover and a decrease in the relative area covered by cloud edge material. Presumably, the other half was due to an increase in cloud liquid water. Cloud height showed no significant change. The average effective droplet radius increased from 9.3 micrometers for daytime observations to 10.2 micrometers at night.

Luo, Gang↗

Titan's 5 micrometers spectral window: carbon monoxide and the albedo of the surface

We have measured the spectrum of Titan near 5 micrometers and have found it to be dominated by absorption from the carbon monoxide 1-0 vibration-rotation band. The position of the band edge allows us to constrain the abundance of CO in the atmosphere and/or the location of the reflecting layer in the atmosphere. In the most likely case, 5 micrometers radiation is reflected from the surface and the mole fraction of CO in the atmosphere is qCO=10(+10/-5) ppm, significantly lower than previous estimates for tropospheric CO. The albedo of the reflecting layer is approximately 0.07(+0.02/-0.01) in the 5 micrometers continuum outside the CO band. The 5 micrometers albedo is consistent with a surface of mixed ice and silicates similar to the icy Galilean satellites. Organic solids formed in simulated Titan conditions can also produce similar albedos at 5 micrometers.

Saturn↗

Influence of Solar-Geomagnetic Disturbances on SABER Measurements of 4.3 Micrometer Emission and the Retrieval of Kinetic Temperature and Carbon Dioxide

Thermospheric infrared radiance at 4.3 micrometers is susceptible to the influence of solar-geomagnetic disturbances. Ionization processes followed by ion-neutral chemical reactions lead to vibrationally excited NO(+) (i.e., NO(+)(v)) and subsequent 4.3 micrometer emission in the ionospheric E-region. Large enhancements of nighttime 4.3 m emission were observed by the TIMED/SABER instrument during the April 2002 and October-November 2003 solar storms. Global measurements of infrared 4.3 micrometer emission provide an excellent proxy to observe the nighttime E-region response to auroral dosing and to conduct a detailed study of E-region ion-neutral chemistry and energy transfer mechanisms. Furthermore, we find that photoionization processes followed by ion-neutral reactions during quiescent, daytime conditions increase the NO(+) concentration enough to introduce biases in the TIMED/SABER operational processing of kinetic temperature and CO2 data, with the largest effect at summer solstice. In this paper, we discuss solar storm enhancements of 4.3 micrometer emission observed from SABER and assess the impact of NO(+)(v) 4.3 micrometer emission on quiescent, daytime retrievals of Tk/CO2 from the SABER instrument.

Mertens, Christopher J.↗

Mineralogy and Thermal Properties of V-Type Asteroid 956 Elisa: Evidence for Diogenitic Material from the Spitzer IRS (5-35 Micrometers) Spectrum

We present the thermal infrared (5-35 micrometer) spectrum of 956 Elisa as measured by the Spitzer Infrared Spectrograph ("IRS"; Houck,1.R. et .11. [20041. Astrophys, 1. SuppL 154, 18-24) together with new ground-based lightcurve data and near-IR spectra. From the visible lightcurve photometry, we determine a rotation period of 16.494 +/- 0.001 h, identify the rotational phase of the Spitzer observations, and estimate the visible absolute magnitude (Hv) at that rotational phase to be 12.58 +/- 0.04. From radiometric analysis of the thermal flux spectrum, we find that at the time of observation 956 Elisa had a projected radius of 5.3 +/- 0.4 km with a visible albedo pv = 0.142+/- 0.022, significantly lower than that of the prototype V-type asteroid, 4 Vesta. (This corresponds to a radius of 5.2 +/- 0.4 km at lightcurve mean.) Analysis with the standard thermal model (STM) results in a sub-solar temperature of 292.3 +/- 2.8 K and beaming parameter eta = 1.16 +/- 0.05. Thermophysical modeling places a lower limit of 20 J m(exp -2)K(exp -1)s(exp -1/2) on the thermal inertia of the asteroid's surface layer (if the surface is very smooth) but more likely values fall between 30 and 150 J m(exp -2)K(exp -1)s(exp -1/2) depending on the sense of rotation. The emissivity spectrum, calculated by dividing the measured thermal flux spectrum by the modeled thermal continuum, exhibits mineralogically interpretable spectral features within the 9-12 micrometer reststrahlen band, the 15-16.5 micrometer Si-O-Si stretching region, and the 16-25 micrometer reststrahlen region that are consistent with pyroxene of diogenitic composition: extant diogenitic pyroxenes fall within the narrow compositional range W0(sub 2+/-1)En(sub 74+/-2)Fs(sub 24+/-1). Spectral deconvolution of the 9-12 micrometer reststrahlen features indicates that up to approximately 20% olivine may also be present, suggesting an olivine-diogenite-like mineralogy. The mid-IR spectrum is inconsistent with non-cumulate eucrite as the major component on the surface of 956 Elisa, although cumulate eucrite material may be present at abundances lower than that of the diogenite component. Analysis of new near-IR spectra of 956 Elisa with the Modified Gaussian Model (MGM; Sunshine, J,M., Pieters, C.M., Pratt, S.F.[1990]. J. Geophys. Res, 95 (May), 6955-6966) results in two pyroxene compositions: 75% magnesian low-Ca pyroxene and 25% high-Ca pyroxene. High-Ca pyroxene is not evident in the mid-IR data, but may belong to a component that is underrepresented in the mid-IR spectrum either because of its spatial distribution on the asteroid or because of its particle size. High-Ca pyroxenes that occur as exsolution lamellae may also be more evident spectrally in the NIR than in the mid-IR. In any case, we find that the mid-IR spectrum of 956 Elisa is dominated by emission from material of diogenite- like composition, which has very rarely been observed among asteroids.

Lim, Lucy F.↗

Photometry of 433 Eros from 0.65 to 2.2 micrometers

Lightcurves of 433 Eros are reported for 11 bandpasses ranging from 0.65 to 2.2 micrometer in wavelength. The relative spectral reflectance was not seen to vary during our observations. Eros has a reflectance at 1.6 micrometers of about 1.5 and at 2.2 micrometers of about 1.7, where the spectral reflectance is scaled to unity at 0.56 micrometers. This spectral reflectance is suggestive of a mixture of silicates and material with high infrared reflectance, perhaps a metallic phase such as meteoritic 'iron'.

Veeder, G. J.↗

Jupiter's spectrum between 12 and 24 micrometers

Spectroscopic measurements of the thermal radiation from Jupiter between 12 and 24 micrometers (420 to 840 reciprocal centimeters) with a resolution of 4 reciprocal centimeters are used to infer the Jovian temperature structure in the pressure region from 0.1 to 0.4 atmosphere. The brightness-temperature spectrum is in good agreement with previous ground-based measurements between 11 and 13 micrometers and with airborne measurements between 18 and 25 micrometers. However, the integrated flux calculated for a filter window and viewing angle equivalent to those of the 20-micrometer channel of Pioneer 10 is 20 per cent below that measured by the Pioneer infrared radiometer. The Q branch of the nu-5 fundamental band of acetylene at 730 reciprocal centimeters appears in emission and leads to a mixing-ratio estimate of 10 to the -6th (plus or minus 0.5) power.

Aumann, H. H.↗

Some 5-13 micrometer airborne observations of Comet Wilson 1986l: Preliminary results

Comet Wilson was observed from the Kuiper Airborne Observatory approximately 23.6 and 25.7 Apr. 1987, UT (approx. 3 to 5 days after perihelion) using the NASA-Ames Faint Object Grating Spectrometer. Spectrophotometric data were observed with a 21 inch aperture between 5 and 13 micrometer and with a spectral resolution of 50 to 100. Spectra of the inner coma and nucleus reveal a fairly smooth continuum with little evidence of silicate emission. The 5 to 8 micrometer color temperature of the comet was 300 + or - 15 K, approx. 15 percent higher than the equilibrium blackbody temperature. All three spectra of the nucleus show a new emission feature at approx. 12.25 micrometer approx. two channels (.22 micrometer) wide. Visual and photographic observations made during the time of these observations showed a broad faint, possible two component tail. No outburst activity was observed.

Lynch, David K.↗

Spectroscopy of Mars from 2.04 to 2.44 micrometers during the 1993 opposition: absolute calibration and atmospheric vs mineralogic origin of narrow absorption features

We present moderate-resolution (lambda/delta lambda = 300 to 370) reflectance spectra of Mars from 2.04 to 2.44 micrometers that were obtained at UKIRT during the 1993 opposition. Seven narrow absorption features were detected and found to have a Mars origin. By comparison with solar and Mars atmospheric spectra, five of these features were attributed all or in part to Mars atmospheric CO2 or CO(2.052 +/- 0.003, 2.114 +/- 0.002, 2.150 +/- 0.003, 2.331 +/- 0.001, and 2.357 +/- 0.002 micrometers). Two of the bands (2.331 +/- 0.001 and 2.357 +/- 0.002 micrometers) appear to have widths and depths that are consistent with additional, nonatmospheric absorptions, although a solar contribution cannot be entirely ruled out. Two other weak bands centered at 2.278 +/- 0.002 and 2.296 +/- 0.002 micrometers may be at least partially mineralogic in origin. The data provide no conclusive identification of the mineralogy responsible for these absorption features. However, examination of terrestrial spectral libraries and previous moderate spectral resolution mineral studies indicates that the most likely origin of these features is either (bi)carbonate or (bi)sulfate anions in framework silicates or (Fe, Mg)-OH bonds in sheet silicates. If the bands are caused by phyllosilicate minerals, then an explanation must be found for the extremely narrow widths of the cation-OH features in the Mars spectra as compared to terrestrial minerals.

Mars↗

2.4 Micrometer Cutoff Wavelength AlGaAsSb/InGaAsSb Phototransistors

We report the first AlGaAsSb/InGaAsSb phototransistors with a cutoff wavelength (50% of peak responsivity) of 2.4 micrometers operating in a broad range of temperatures. These devices are also the first AlGaAsSb/InGaAsSb heterojunction phototransistors (HPT) grown by molecular beam epitaxy (MBE). This work is a continuation of a preceding study, which was carried out using LPE (liquid phase epitaxy)-grown AlGaAsSb/InGaAsSb/GaSb heterostructures. Although the LPE-related work resulted in the fabrication of an HPT with excellent parameters [1-4], the room temperature cutoff wavelength of these devices (approximately 2.15 micrometers) was determined by fundamental limitations implied by the close-to-equilibrium growth from Al-In-Ga-As-Sb melts. As the MBE technique is free from the above limitations, AlGaAsSb/InGaAsSb/GaSb heterostructures for HPT with a narrower bandgap of the InGaAsSb base and collector - and hence sensitivity at longer wavelengths (lambda) - were grown in this work. Moreover, MBE - compared to LPE - provides better control over doping levels, composition and width of the AlGaAsSb and InGaAsSb layers, compositional and doping profiles, especially with regard to abrupt heterojunctions. The new MBE-grown HPT exhibited both high responsivity R (up to 2334 A/W for lambda=2.05 micrometers at -20 deg C.) and specific detectivity D* (up to 2.1 x 10(exp 11) cmHz(exp 1/2)/W for lambda=2.05 micrometers at -20 deg C).

Sulima, O. V.↗

High-Resolution IR Absorption Spectroscopy of Polycyclic Aromatic Hydrocarbons in the 3-micrometers Region: Role of Periphery

In this work we report on high-resolution IR absorption studies that provide a detailed view on how the peripheral structure of irregular polycyclic aromatic hydrocarbons (PAHs) affects the shape and position of their 3-micrometers absorption band. To this purpose we present mass-selected, high-resolution absorption spectra of cold and isolated phenanthrene, pyrene, benz[a]antracene, chrysene, triphenylene, and perylene molecules in the 2950-3150 per cm range. The experimental spectra are compared with standard harmonic calculations, and anharmonic calculations using a modified version of the SPECTRO program that incorporates a Fermi resonance treatment utilizing intensity redistribution. We show that the 3-micrometers region is dominated by the effects of anharmonicity, resulting in many more bands than would have been expected in a purely harmonic approximation. Importantly, we find that anharmonic spectra as calculated by SPECTRO are in good agreement with the experimental spectra. Together with previously reported high-resolution spectra of linear acenes, the present spectra provide us with an extensive dataset of spectra of PAHs with a varying number of aromatic rings, with geometries that range from open to highly-condensed structures, and featuring CH groups in all possible edge configurations. We discuss the astrophysical implications of the comparison of these spectra on the interpretation of the appearance of the aromatic infrared 3-micrometers band, and on features such as the two-component emission character of this band and the 3-micrometers emission plateau.

techniques: spectroscopic↗

Micrometer: Micromechanics transformer for predicting full field mechanical responses of heterogeneous materials

Predicting mechanical responses of heterogeneous materials across scales remains a significant challenge. Traditional computational methods often struggle with complex and multiscale nature of these materials, limiting their effectiveness in real-world applications. Here, in this paper, we introduce Micrometer, a vision transformer based deep learning model designed to predict full field mechanical responses of heterogeneous materials, bridging the gap between computer vision and solid mechanics problems. We show that Micrometer, trained on a large-scale high-resolution dataset of 2D fiber-reinforced composites, can achieve state-of-the-art performance in predicting microscale strain fields across a wide range of material properties and loading conditions. Our model demonstrates accuracy and computational efficiency in applications such as computational homogenization and multiscale modeling, reducing computational time by up to two orders of magnitude compared to conventional numerical solvers while maintaining less than 1 % errors in predicting macroscale stress fields. Furthermore, we showcase Micrometer’s adaptability through transfer learning experiments on new materials with limited data, highlighting its potential to tackle diverse scenarios in computational solid mechanics. These results represent a significant step towards AI-driven innovation in materials science, addressing the limitations of traditional numerical methods and paving the way for more efficient simulations of heterogeneous materials across various industrial applications.

Composite materials↗

Traveling digital counters for micrometers

Five digit micrometer readings are made directly and quickly with no loss of precision. It is virtually impossible for micrometer to be misread. Digitized micrometer can also be used for reptitive measurements.

Haley, C. T.↗

High sensitivity infrared 10.6 micrometer heterodyne receiver development

The results are presented for a study on the design of an infrared 10.6-micrometer quantum-noise-limited optical receiver subsystem. Performance measurements of the HgCdTe photomixer preamplifier combination were carried out for photomixer temperatures up to 152 K and a photomixer frequency response of up to 420 MHz was obtained. Results of temperature and bias cycling of HgCdTe photomixers are reported. Design considerations for an operational 10.6 micrometer heterodyne receiver are presented. These consist of design data on required laser LO illumination, heat load levels for photomixer cooler, photomixer uniformity and the effects of photomixer impedance match on receiver sensitivity. Analysis and measurements of 10.6 micrometer heterodyne detection in an extrinsic photoconductive (p-type) HgCdTe photomixer are also presented.

Source record↗

Io - An intense brightening near 5 micrometers

Spectrophotometric observations of the Jovian satellite Io on February 20 and 21, 1978, (Universal Time) were made from 1.2 to 5.4 micrometers. Io's brightness at 4.7 to 5.4 micrometers was found to be three to five times greater at an orbital phase angle of 68 deg than at orbital phase angles of 23 deg (5.5 hours before the brightening) and 240 deg (20 hours after the brightening). Since the 5-micrometer albedo of Io is near unity under ordinary conditions, the observed transient phenomenon must have been the result of an emission mechanism. Although several such mechanisms were examined, the actual choice is not clear.

Witteborn, F. C.↗

Micrometer for Measuring Trepanned Grooves

Special micrometer measures diameter of circular groove on face of large part, while part is mounted in lathe chuck. Tool has curved frame so it can reach around obstruction on centerline of part. At one end of frame is blade/ micrometer spindle for reaching into groove to be measured; this type of spindle does not rotate when micrometer thimble is turned in taking measurement. Other end of frame has sliding foot with blade.

Bird, S. K.↗

The relationship of the lunar regolith less than 10 micrometer fraction and agglutinates. I - A model for agglutinate formation and some indirect supportive evidence

The first part of a study of the 'less than 10 micrometer' soil fraction and agglutinates is concerned with the chemical systematics of the considered fraction of lunar soils, taking into account a model for agglutinate formation based on the fusion of the finest fraction (FFF). Attention is given to some evidence which supports the FFF model. The evidence is based on some indirect approaches to an estimation of the composition of the fused soil component. It is found that the 'less than 10 micrometer' soil fraction from all Apollo sites except Apollo 16 (which can be explained) is more feldspathic and enriched in incompatible elements (e.g., K and Th) than the bulk soil. It is concluded that these systematics result from simple comminution in which feldspar breaks down to finer sizes than pyroxene and olivine and the fine-grained incompatible-element-enriched mesostasis concentrates in the 'less than 10 micrometer' soil fraction.

Papike, J. J.↗

Preliminary analysis of recent 2.2-4.2 micrometers telescopic observations of Elysium, Mars: Implications for crystallinity and hydration state of surface materials

Comparisons of the telescopic reflectance spectrum of a Martian bright region, in the 2.2 to 4.2 micrometers region, with recent laboratory studies of materials in this same wavelength range are consistent with: terrestrial materials which are dehydrated relative to the terrestrial environment, and terrestrial materials which exhibit spectral behavior indicative of some degree of sample crystallinity which is greater than that of amorphous palagonites. This second conclusion is in agreement with recent suggestions concerning the Martian bright regions. However, additional laboratory research is required in order to constrain: the degree of crystallinity required to result in the 2.8 to 2.9 micrometers spectral behavior seen in the terrestrial samples, and the limit of crystalline material which can be accommodated in a mixture with measured telescopic data of Mars (0.3 to 4.2 micrometers).

Roush, T. L.↗

Comparison of the 3.36 micrometer feature to the ISM

It has been noted that the 3.36 micrometer emission feature is not the same as that of any ISM band at 3.4 micrometer. This is documented herein. There is no convincing analog to the cometary 3.36 micrometer emission feature seen in the Interstellar Matter band. This fact suggests that if the carbonaceous material in comets came from the ISM, it was either further processed in the solar nebula or has a different appearance because of the different excitation environment of the sun and ISM.

Tokunaga, Alan T.↗