Magnetic Gearing Versus Conventional Gearing in Actuators for Aerospace Applications

Magnetic geared actuators (MGA) are designed to perform highly reliable, robust and precise motion on satellite platforms or aerospace vehicles. The design allows MGA to be used for various tasks in space applications. In contrast to conventional geared drives, the contact and lubrication free force transmitting elements lead to a considerable lifetime and range extension of drive systems. This paper describes the fundamentals of magnetic wobbling gears (MWG) and the deduced inherent characteristics, and compares conventional and magnetic gearing.

Puchhammer, Gregor↗

Magnetic gear backup

Backup clutch for magnetic gear operates only in case of slippage. Contacting a pin arrangement in the driven gear, the clutch provides extra force for continuing output. It does not interfere with normal, noncontact action.

Shefke, R. A.↗

Design Study of a Coupled Inner-Stator Magnetically Geared Motor for Electric Aircraft Applications

Electric aircraft require high performance and high reliability electric motor drivetrains. A geared electric motor drivetrain will outperform a direct drive motor drivetrain in most applications. Traditional mechanical gearing, however, has mechanical contact-based wear and failure modes that result in added maintenance costs and require an oil lubrication system. Magnetically geared motor drives are a potential technology for electric aircraft applications capable of enabling the benefits of a geared drive without the maintenance, reliability, and lubrication system cost of mechanical gears. In this paper, a topology of magnetically geared motor, an inner stator magnetically geared motor, is explored to estimate its achievable performance for electric aircraft applications. Optimization results on the topology show that it can achieve greater than 15 Nm/kg and 96% efficiency at 100 kW of power.

Thomas Tallerico↗

Design Study of a Coupled Inner-Stator Magnetically Geared Motor for Electric Aircraft Applications

Abstract- Electric aircraft require high performance and high reliability electric motor drivetrains. A geared electric motor drivetrain will outperform a direct drive motor drivetrain in most applications. Traditional mechanical gearing, however, has mechanical contact-based wear and failure modes that result in added maintenance costs and require an oil lubrication system. Magnetically geared motor drives are a potential technology for electric aircraft applications capable of enabling the benefits of a geared drive without the maintenance, reliability, and lubrication system cost of mechanical gears. In this paper, a topology of magnetically geared motor, an inner-stator magnetically geared motor, is explored to estimate its achievable performance for electric aircraft applications. Optimization results on the topology show that it can achieve greater than 15 Nm/kg specific torque and 96% efficiency at 100 kW of power.

Thomas Tallerico↗

Design and Hardware Progress on a Magnetically-Geared Actuator for Extremely Cold Lunar Environments

Introduction: Under the Motors for Dusty and Extremely Cold Environments (MDECE) Project, NASA Glenn Research Center is developing a magnetically-geared actuator for extremely cold space environments to avoid the wiring and significant efficiency penalty associated with heating grease-lubricated actuators as well as the stringent life and loading constraints imposed by dry film lubricated mechanical gears. The heating penalty can be equivalent to up to a 90% efficiency reduction in permanently shadowed regions on the Moon. This poster or presentation will summarize the progress made over the past 6-12 months on designing the fully-functional actuator and building a proof-of-concept actuator and testing it in an ambient environment. Design Progress: A critical design review was successfully completed at the end of June 2023. This presentation will touch on the key highlights from that review in the areas of electro-magnetic design and optimization, bearing optimization, thermal analysis, structural analysis, and mechanical design and manufacturing. The predicted technical performance measures of the actuator will be mentioned. The team is currently finishing some actions from the review and finalizing the drawing package in preparation for hardware procurement. Hardware Progress: Despite some significant delays in receiving fabricated parts and magnetic subassemblies, progress was made in manufacturing and assembling a proof-of-concept version of both the actuator’s magnetically-geared motor (Fig. 1) and the actuator’s cycloidal-type output magnetic gear stage (Fig. 2) [3]. The presentation will mention key lessons learned to date from the fabrication, assembly, and testing of the proof of concept.

Lunar surface↗

Detailed Design of a Magnetically-Geared Actuator for Use in Extremely Cold Lunar Environments

A magnetically-geared actuator is being developed for extremely cold space environments to avoid the wiring and significant efficiency penalty associated with heating grease-lubricated actuators as well as the stringent life and loading constraints imposed by dry film lubricated mechanical gears. This paper describes the detailed design of this actuator, including the impactful requirements, thermal analysis, bearing loads, electromagnetic analysis and the impact of tolerance stack up, and structural analysis.

space mechanisms↗

Detailed Design of a Magnetically-Geared Actuator for use in Extremely Cold Lunar Environments

A magnetically-geared actuator is being developed for extremely cold space environments to avoid the wiring and significant efficiency penalty associated with heating grease-lubricated actuators as well as the stringent life and loading constraints imposed by dry film lubricated mechanical gears. This paper describes the detailed design of this actuator, including the impactful requirements, thermal analysis, bearing loads, electromagnetic analysis and the impact of tolerance stack up, and structural analysis.

space mechanisms↗

Development and Manufacture of A Proof-of-Concept Magnetically-Geared Actuator for Use in Extremely Cold Lunar Environments

A magnetically-geared actuator is being developed for extremely cold space environments to avoid the wiring and significant efficiency penalty associated with heating grease-lubricated actuators as well as the stringent life and loading constraints imposed by dry film lubricated mechanical gears. This paper describes the lessons learned while designing, manufacturing, and assembling a proof-of-concept prototype similar to the preliminary design of the actuator.

lunar surface↗

Development and Manufacture of A Proof-of-Concept Magnetically-Geared Actuator for Use in Extremely Cold Lunar Environments

A magnetically-geared actuator is being developed for extremely cold space environments to avoid the wiring and significant efficiency penalty associated with heating grease-lubricated actuators as well as the stringent life and loading constraints imposed by dry film lubricated mechanical gears. This paper describes the lessons learned while designing, manufacturing, and assembling a proof-of-concept prototype similar to the preliminary design of the actuator.

lunar surface↗

Dynamic Testing of a High-Specific-Torque Concentric Magnetic Gear

This paper presents initial measurements of the efficiency of NASA's 2nd magnetic gear prototype. A detailed discussion of the test rig's design and capabilities was presented, along with a thorough uncertainty analysis. The reported uncertainties are 95% confidence intervals that include the effects of temperature and parasitic loads. The prototype's response was measured at output speeds between 124 rpm and 744 rpm for a controlled output torque of 10 Nm (8% of the prototype's maximum torque). After correcting for tare losses, the prototype's efficiency was found to decrease from 90.0% to 83.0% as speed increased. If the efficiency is extrapolated to a typical operating condition (85% of maximum torque) using the good assumption that energy loss is approximately independent of the transmitted torque, the expected efficiency would be 99.0% to 98.4%, which exceeds the state of the art for these speeds.

magnetic gears↗

Dynamic Testing of a High-Specific-Torque Concentric Magnetic Gear

This presentation presents measurements of the efficiency of NASA's 2nd magnetic gear prototype. A detailed discussion of the test rig used to make these measurements was presented, including a thorough uncertainty analysis. The reported uncertainties are 95% confidence intervals that include the effects of temperature and parasitic loads. The prototype's response was measured at output speeds between 124 rpm and 744 rpm for a controlled output torque of 10 Nm (8% of the prototype's maximum torque). After correcting for tare losses, the prototype's efficiency was found to decrease from 90.0% to 83.0% as speed increased. If the efficiency is extrapolated to a typical operating condition (85% of maximum torque) using the good assumption that energy loss is approximately independent of the transmitted torque,the expected efficiency would be 99.0% to 98.4%, which exceeds the state of the art for these speeds.

Scheidler, Justin↗

High Speed Testing of a High Efficiency Concentric Magnetic Gear

This presentation presents measurements of the efficiency of NASA's 2nd magnetic gear prototype. A detailed discussion of the test rig used to make these measurements was presented, including a thorough uncertainty analysis. The reported uncertainties are 95% confidence intervals that include the effects of temperature and parasitic loads. The prototype's response was measured at output speeds between 124 rpm and 744 rpm for a controlled output torque of 10 Nm (8% of the prototype's maximum torque). After correcting for tare losses, the prototype's efficiency was found to decrease from 90.0% to 83.0% as speed increased. If the efficiency is extrapolated to a typical operating condition (85% of maximum torque) using the good assumption that energy loss is approximately independent of the transmitted torque,the expected efficiency would be 99.0% to 98.4%, which exceeds the state of the art for these speeds.

Scheidler, Justin↗

Automated parking garage system model

A one-twenty-fifth scale model of the key components of an automated parking garage system is described. The design of the model required transferring a vehicle from an entry level, vertically (+Z, -Z), to a storage location at any one of four storage positions (+X, -X, +Y, +Y, -Y) on the storage levels. There are three primary subsystems: (1) a screw jack to provide the vertical motion of the elevator, (2) a cam-driven track-switching device to provide X to Y motion, and (3) a transfer cart to provide horizontal travel and a small amount to vertical motion for transfer to the storage location. Motive power is provided by dc permanent magnet gear motors, one each for the elevator and track switching device and two for the transfer cart drive system (one driving the cart horizontally and the other providing the vertical transfer). The control system, through the use of a microprocessor, provides complete automation through a feedback system which utilizes sensing devices.

Collins, E. R., Jr.↗

Advancing Dust Tolerant Mechanisms for a Sustained Exploration of the Moon

Introduction: “I think dust is probably one of our greatest inhibitors to a nominal operation on the Moon. I think we can overcome other physio-logical or physical or mechanical problems except dust.”– Gene Cernan, Apollo 17 Technical Debrief The Apollo missions revealed the impact of lu-nar dust on mechanisms. Lunar dust particles are jagged and electrostatically charged, giving them the ability to bind or damage mechanisms and alter thermal properties. Reports documented clogged equipment and jammed mechanisms in every mission, regardless of surface duration, as well as clogged mechanisms in the Extravehicular Mobility Suit (EMS), including zippers, wrist and hose locks, faceplates, and sunshades [1-2]. Several astronauts remarked they could not have sustained surface activity much longer because clogged joints would have frozen up completely [2]. Effective dust mitigation strategies are need-ed to support longer duration stays on the lunar surface [3-4]. State of the Art: Technology for mechanisms able to operate in dusty enviroments is advancing rapidly due to the needs of both Mars rovers and the Artemis program. Vacuum-tight connectors are essential for spacesuits and habitats, and their performance can be dependent on cleaning technologies, which have proven difficult on the lunar surface. Several TRL 3-5 technologies are undergoing tests with the expectation to reach TRL 6 within 1-2 years. Some mechanisms will be infused and tested on the VIPER (Volatiles Inves-tigating Polar Exploration Rover) mission planned for mid-2020s. NASA Funded Efforts: NASA has recognized the need for dust tolerant mechanisms, and has partnered with industry to advance the state-of-the-art. At NASA GRC, KSC, and JSC, the Dust Tolerant Mechanisms Project is working to devel-op advanced actuator seals for rotary joints and rotary bearing technologies for long-term sus-tained operation in lunar dust environments. An-other NASA project at NASA GRC, partnered with GSFC, JPL, and KSC is Motors for Dusty & Ex-treme Cold Environments (MDECE). MDECE is developing an unheated magnetically-geared mo-tor that can operate continuously for a long dura-tion at an ambient temperature of -243 ºC (33 K). NASA GRC has the capability to characterize the effects of dust on seals, mechanisms, and other mating surfaces and components under lunar conditions [5]. Through the SBIR/STTR program, NASA has funded several companies to advance dust toler-ant mechanisms via the Dust Tolerant Mecha-nisms sub-topic with applications in surface mobil-ity, spacesuits, connectors, joints, and more. LSIC and Community Efforts: The Lunar Surface Innovation Consortium (LSIC) Dust Miti-gation focus group has fostered collaborations across NASA, industry, and academia to develop solutions that minimizes the impact of lunar dust on robotic and human systems. Community ef-forts have included topical meetings on dust tol-erant mechanisms, featured technology presenta-tions, and feedback to NASA on potential gaps and needs. Testing: In 2021, NASA released NASA-STD-1008 [6]. This NASA Technical Standard estab-lishes minimum requirements and provides guid-ance for testing systems and hardware to be ex-posed to dust in planetary environments. The standard has specific sections dedicated to Mechanisms Testing (e.g. bearings, gears) as well as Seals and Mating Surfaces Testing (e.g. hatches, docking systems). Gaps and Needs: NASA is tracking dust tol-erant mechanisms as a gap in a cross-directorate analysis of capability areas needed to enable fu-ture human space-flight architectures. Two high-priority gap areas include additional facilities for testing mechanisms in lunar-surface conditions, and a better understanding of vulnerabilities to the smallest, nanometer-scale dust particles. Conclusion: Understanding and mitigating lu-nar dust is critical to successful, sustained opera-tions on the lunar surface – whether autonomous or otherwise. This presentation will discuss both the state-of-the-art and open needs in lunar dust tolerant mechanisms, technology impacts, mitiga-tion approaches, testing, LSIC community efforts, and more. References: [1] Gaier, J. R. (2020). The Im-pact of Dust on Lunar Surface Equipment During Apollo. Lunar Dust 2020. [2] GRC, & Gaier, J. R. (2005). The Effects of Lunar Dust on EVA Sys-tems During the Apollo Missions. [3] Johansen, M. R. (2020). An Update on NASA’s Lunar Dust Mitigation Strategy. Lunar Dust 2020. [4] ASI, CSA, ESA, JAXA, & NASA. (2016). Dust Mitiga-tion Gap Assessment Report. [5] Jimenez, N. et al (2022), LPSC Abstract 2572. [6] NASA-STD-1008, 2021.

J I Nunez↗

Water Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design, fabricate, and test a preflight prototype pump for use in the Extravehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump will accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting noncondensable gas without becoming "air locked." The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the preflight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES will simulate the vacuum environment in which the flight pump will operate. Testing will verify that the pump meets design requirements for range of flow rates, pressure rise, power consumption, working fluid temperature, operating time, and restart capability. Pump testing is currently scheduled for March, 2009, after which the pump will be delivered to NASA for further testing.

Schuller, Michael↗

Custom Unit Pump Design and Testing for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the pre-flight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion , and restart capability under both ambient and vacuum conditions. The pump operated between 40 and 240 lbm/hr flowrate, 35 to 100 F pump temperature range, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test. The test results contained a number of anomalies, specifically power increases and a few flow stoppages, that prompted TEES and Honeywell to disassemble and inspect the pump. Inspection indicated contamination in the pump and fit issues may have played roles in the observed anomalies. Testing following reassembly indicated that the performance of the pump 1) matched both the predicted performance values, 2) the performance values measured prior to disassembly, and 3) was free of the anomalies noted in the pre-disassembly testing.

Schuller, Michael↗