Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mid-IR lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

36 records · Page 2

Optical, electrical, and EPR studies of polycrystalline Al:Cr:ZnSe gain elements

Transition metal-doped II-VI (TM:II-VI) chalcogenides are well-known laser materials for optically pumped middle-infrared lasers. Cr:ZnSe is a key representative of this class of transition metal doped II-VI gain media and is arguably considered the material of choice for optically pumped middle-infrared lasers. In addition to effective mid-IR lasing under optical excitation, these crystals, being wide-band semiconductors, hold the potential for direct electrical excitation. One way to form n-type conductivity in ZnSe crystals is by annealing them in a melt of Zn-Al alloy. However, this annealing of Cr:ZnSe crystals results in their purification and transfer of chromium to the melt of Zn-Al alloy. In this article, we report on optimizing the doping technique for providing n-type conductivity in Al:Cr:ZnSe crystals while preserving the chromium concentration. Al:Cr:ZnSe samples with resistivities ranging from 10.8 to 992 Ω-cm were fabricated. While the 2 + valence state of Cr is typically dominant in Cr:ZnSe, both Cr 2+ and Cr + were detected in Al:Cr:ZnSe samples. The maximum level of Cr + concentration was measured to be 4 × 10 18 cm -3 .

36 MATERIALS SCIENCE↗

Amplification of 10 μm picosecond pulses in a compact optically pumped multiatmosphere CO 2 laser

Picosecond pulses, generated by a commercial mid-IR optical parametric source (∼0.5 ps, 1-5 μJ), have been regeneratively amplified to an energy of ≤2 mJ in a palm-size high-pressure CO 2 amplifier optically pumped by a Q-switched 2.8 μm Cr:Er:YSGG laser. The characteristics of the amplified pulses have been studied as a function of seed wavelength centered around 10.3 or 10.6 μm, and the pressure in the gain medium. The measured amplified pulse length is ∼5 ps. Numerical modeling suggests that pulses as short as ∼0.5 ps with multi-GW peak power can be generated in a mixture of CO 2 isotopes. Robustness of the output of a compact CO 2 regenerative amplifier to the seed and pump fluctuations measured at 3 Hz and a perfect Gaussian beam profile indicates the potential of such laser technology for producing high-power ultrashort long-wave infrared pulses at high repetition rates.

43 PARTICLE ACCELERATORS↗

Mid-infrared frequency doubling using strip-loaded silicon nitride on epitaxial barium titanate thin film waveguides

Broadband mid-infrared (mid-IR) frequency doubling was demonstrated using nonlinear barium titanate (BTO) thin films. The device has a strip-loaded waveguide structure consisting of top silicon nitride (SiN) strips and an underneath BTO guiding layer. The epitaxial BTO was deposited on a strontium titanate (STO) substrate by pulsed-laser deposition. Through a SiN grating coupler, the pumping mid-IR light at wavelength &#x03BB;<!-- λ --> = 3.30 &#x2212;<!-- - --> 3.45 &#x00B5;<!-- µ --> m was coupled into the nonlinear BTO layer, where the spectrum of the near-infrared (NIR) second-harmonic generation was characterized. The developed BTO waveguides provide a platform for mid-IR nonlinear integrated photonics and on-chip quantum optics.

42 ENGINEERING↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

One-dimensional mapping of femtosecond laser filaments using coherent microwave scattering

Here, this paper reports on the use of coherent microwave scattering (CMS) for spatially resolved electron number density measurements of elongated plasma structures induced at mid-IR femtosecond filamentation in air. The presented studies comprise one-dimensional mapping of laser filaments induced via 3.9 µm, 127.3 fs laser pulses at output energies up to 15 mJ. The axial electron number density was measured to be invariant (about 2 × 10 15 c⁢m −3 ) along the entire filament length and for all tested laser pulse energies 5–15 mJ, and the corresponding laser intensity in the middle portion of the filament was estimated to be nearly constant for 5–15 mJ pulse energies (about 30−40 TW/c⁢m 2 ). These findings support that intensity clamping conditions were achieved in the experiments. The proposed approach enables capabilities that are currently unavailable to perform absolute and longitudinally resolved measurements of electron number density in laser filaments and to precisely characterize conditions associated with self-focusing and intensity clamping.

plasma diagnostic techniques↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mid-Infrared Nonlinear Frequency Conversion Using Monolithic Barium Titanate on Silicon-on-Insulator

In this work, efficient nonlinear frequency conversion in the mid-infrared (mid-IR) region was demonstrated by a barium titanate (BTO) on a silicon-on-insulator (SOI) substrate. The BTO thin film was epitaxially grown by pulsed-laser deposition (PLD). The tensorial second order optical nonlinearity and the ferroelectric domain property of the BTO were characterized by the polarimetric mid-IR second harmonic generation (SHG) measurements. Azimuthal-dependent polarized SHG was modeled at different combinations of the nonlinear coefficient $d_{ij}$ and the domain fraction factor $ΔD^Y/ΔD^X$. Strong SHG intensity was experimentally observed over a broad spectrum at λ = 3.1 μm - 3.7 μm. A characteristic linear dependence between the SHG signal and the square of the pumping laser intensity was observed. The monolithic integration between the epitaxial BTO and the Si provides a compact platform for efficient on-chip light generation and quantum photonic technologies.

25 ENERGY STORAGE↗

Octave-spanning mid-infrared femtosecond OPA in a ZnGeP 2 pumped by a 2.4 μm Cr:ZnSe chirped-pulse amplifier

We report on the highly efficient, octave-spanning mid-infrared (mid-IR) optical parametric amplification (OPA) in a ZnGeP 2 (ZGP) crystal, pumped by a 1 kHz, 2.4 μm, 250 fs Cr:ZnSe chirped-pulse amplifier. The full spectral coverage of 3−10 μm with the amplified signal and idler beams is demonstrated. The signal beam in the range of ∼3 − 5 μm is produced by either white light generation (WLG) in YAG or optical parametric generation (OPG) in ZGP using the common 2.4 μm pump laser. We demonstrate the pump to signal and idler combined conversion efficiency of 23% and the pulse energy of up to 130 μJ with ∼2 μJ OPG seeding, while we obtain the efficiency of 10% and the pulse energy of 55 μJ with ∼0.2 μJ WLG seeding. The OPA output energy is limited by the available pump pulse energy (0.55 mJ at ZGP crystal) and therefore further energy scaling is feasible with multi-stage OPA and higher pump pulse energy. The autocorrelation measurements based on random quasi-phase matching show that the signal pulse durations are ∼318 fs and ∼330 fs with WLG and OPG seeding, respectively. In addition, we show the spectrally filtered 30 μJ OPA output at 4.15 μm suitable for seeding a Fe:ZnSe amplifier. Our ultrabroadband femtosecond mid-IR source is attractive for various applications, such as strong-field interactions, dielectric laser electron acceleration, molecular spectroscopy, and medical surgery.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband Fourier-Transform Optical Photothermal Infrared Spectroscopy and Imaging

Infrared (IR) spectroscopy is a powerful method for mapping chemical heterogeneity on the microscale. Synchrotron IR radiation uniquely provides a high brightness and broad bandwidth to further extend the capabilities of IR spectroscopic imaging. However, the diffraction-limited spatial resolution of IR spectroscopy is insufficient for studies requiring submicrometer spatial differentiation. Optical photothermal IR (O-PTIR) microscopy is a powerful, emerging method that overcomes the IR diffraction limit in IR hyperspectral imaging by employing a modulated IR beam and a visible probe laser beam to detect local temperature-induced modulation at the visible diffraction limit. In this work, we extend the spectral range of photothermal infrared measurements by incorporating a synchrotron IR source, demonstrating a combined synchrotron-based O-PTIR modality that enables high spatial resolution far-field chemical imaging spanning the entire mid-IR range. Both optical- and fluorescence-detected photothermal modalities were performed using a step-scan interferometer, demonstrating improved spectral range (541-4000 cm-1) when compared to optical photothermal microscopy with commercial laser sources (800-1800 cm-1 for this particular source) and improved spatial resolution, when compared to synchrotron microspectroscopy measurements. Following these initial validation studies, synchrotron Fourier-transform fluorescence-detected photothermal IR spectroscopy in combination with synchrotron microspectroscopy measurements was used to differentiate cells in mouse brain tissue sections, which requires submicron spatial resolutions beyond those accessible by IR spectroscopy alone.

Razumtcev, Aleksandr↗

Soft x-ray high-harmonic generation in an anti-resonant hollow core fiber driven by a 3 μ m ultrafast laser

High-harmonic upconversion driven by a mid-infrared femtosecond laser can generate coherent soft x-ray beams in a tabletop-scale setup. Here, we report on a compact ytterbium-pumped optical parametric chirped pulse amplifier (OPCPA) laser system seeded by an all-fiber front-end and employing periodically poled lithium niobate (PPLN) nonlinear media operated near the pulse fluence limits of current commercially available PPLN crystals. The OPCPA delivers 3 µm wavelength pulses with 775 µJ energy at 1 kHz repetition rate, with transform-limited 120 fs pulse duration, diffraction-limited beam quality, and ultrahigh 0.33% rms energy stability over >18 h. Using this laser, we generate soft x-ray high harmonics (HHG) in argon gas by focusing into a low-loss, high-pressure gas-filled anti-resonant hollow core fiber (ARHCF), generating coherent light at photon energies up to the argon L-edge (250 eV) and carbon K-edge (284 eV), with high beam quality and ∼1% rms energy stability. This work demonstrates soft x-ray HHG in a high-efficiency guided-wave phase matched geometry, overcoming the high losses inherent to mid-IR propagation in unstructured waveguides, or the short interaction lengths of gas cells or jets. The ARHCF can operate in the long term without damage and with the repetition rate, stability, and robustness required for demanding applications in spectromicroscopy and imaging. Finally, we discuss routes for further optimizing the soft x-ray HHG flux by driving He at higher laser intensities using either the signal (1.5 μm) or idler wavelengths (3 μm).

Femtosecond lasers↗

Hot-pressed ceramic Fe:ZnSe gain-switched laser

We report the first room temperature gain-switched Fe:ZnSe hot-pressed ceramic laser pumped by 2.94 µm radiation of mechanically Q-switched Er:YAG laser. The maximum output energy at 4.2 µm was 41 mJ at 3 Hz repetition rate and 120 ns pulse duration. The measured slope efficiency was 25% with respect to the absorbed energy. This technique could be attractive for the future development of high-energy short-pulse solid-state mid-IR systems.

36 MATERIALS SCIENCE↗

Sequential infiltration of two-photon polymerized 3D photonic crystals for mid-IR spectroscopic applications

Photonic crystals (PhCs) are spatially organized structures with lattice parameters equivalent to the operational wavelength of light. PhCs have been subject to extensive research efforts in the last two decades and are known for controlling light propagation with applications in sensing and time-delayed communication due to the slow-light phenomenon. Despite their exceptional properties, PhCs are difficult to fabricate using planar micromachining techniques due to their periodic structures. Techniques like two-photon stereolithography have been discussed for PhC fabrication in the literature, but the inherent disadvantage of poor refractive index (RI) contrast results in limited application. In this work, we present sequential infiltration synthesis performed on two-photon stereolithographically printed 3D PhCs for infiltration with zinc oxide to increase the RI of 3D PhCs. Further, finite element analysis was performed over a range of RI contrast values to study the change in photonic bandgap (PBG) with RI contrast. The transmission spectra were recorded on 3D PhCs before and after infiltration to demonstrate the change experimentally. An increase in the PBG width and absorbance is seen postinfiltration due to enhanced RI. This work presents the first, to our knowledge, sequentially infiltrated enhanced 3D PhC fabricated with two-photon stereolithography.

3D printing↗

Exploring the effects of molecular beam epitaxy growth characteristics on the temperature performance of state-of-the-art terahertz quantum cascade lasers

This study conducts a comparative analysis, using non-equilibrium Green’s functions (NEGF), of two state-of-the-art two-well (TW) Terahertz Quantum Cascade Lasers (THz QCLs) supporting clean 3-level systems. The devices have nearly identical parameters and the NEGF calculations with an abrupt-interface roughness height of 0.12 nm predict a maximum operating temperature (T max ) of ~ 250 K for both devices. However, experimentally, one device reaches a T max of ~ 250 K and the other a T max of only ~ 134 K. Both devices were fabricated and measured under identical conditions in the same laboratory, with high quality processes as verified by reference devices. The main difference between the two devices is that they were grown in different MBE reactors. Our NEGF-based analysis considered all parameters related to MBE growth, including the maximum estimated variation in aluminum content, growth rate, doping density, background doping, and abrupt-interface roughness height. From our NEGF calculations it is evident that the sole parameter to which a drastic drop in T max could be attributed is the abrupt-interface roughness height. We can also learn from the simulations that both devices exhibit high-quality interfaces, with one having an abrupt-interface roughness height of approximately an atomic layer and the other approximately a monolayer. However, these small differences in interface sharpness are the cause of the large performance discrepancy. This underscores the sensitivity of device performance to interface roughness and emphasizes its strategic role in achieving higher operating temperatures for THz QCLs. We suggest Atom Probe Tomography (APT) as a path to analyze and measure the (graded)-interfaces roughness (IFR) parameters for THz QCLs, and subsequently as a design tool for higher performance THz QCLs, as was done for mid-IR QCLs. Our study not only addresses challenges faced by other groups in reproducing the record T max of ~ 250 K and ~ 261 K but also proposes a systematic pathway for further improving the temperature performance of THz QCLs beyond the state-of-the-art.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Coupling to rotational manifolds to improve gas-phase pump–probe spectroscopic models

The physical picture of gas-phase optical transitions is normally presented as an isolated two-level system balanced by upward and downward processes. Isolated models assume a phenomenological treatment of collisional dephasing but do not strictly account for collisional population exchange with the rotational baths. While this assumption is valid under low-intensity conditions, where excitation is rate-limiting, isolated models can deviate from Beer’s Law at sufficient pressures and monochromatic intensities when both collisional broadening and power broadening are comparable to (or greater than) lifetime broadening, which are not uncommon conditions for cavity enhanced spectroscopies in the mid-IR spectral range. Although this problem has been addressed by rate-equation models for linear absorption measurements, a general treatment for multi-level quantum mechanical models suitable for non-linear absorption measurements (two-photon/two-color/pump–probe) is lacking. Isolated models require physical parameter inputs that disagree with expected values by at least an order of magnitude. These non-physical models undermine the ability to predict non-linear signal strengths under untested conditions and thereby limit the potential to optimize the sensitivity of non-linear spectroscopies and to expand their analytical applications (e.g., new analytes and/or buffer gases, changes in cavity free-spectral-range, changes in intracavity powers or wavelengths, and accurate investigation of physical phenomena). In this study, we derive bath-coupled models for gaseous pump–probe spectroscopy by application of the quantum Lindblad equation and detailed balance. Bath-coupled models are shown to fit data consistently across variations in intensity and agree with all physically expected values.

Cavity ring-down spectroscopy↗

Ultra-short pulse generation from mid-IR to THz range using plasma wakes and relativistic ionization fronts

In this work, we discuss numerical and experimental results on frequency downshifting and upshifting of a 10 μ m infrared (IR) laser to cover the entire wavelength (frequency) range from λ = 1 to 150 μ m ( ν = 300–2 THz) using two different plasma techniques. The first plasma technique utilizes frequency downshifting of the drive laser pulse in a nonlinear plasma wake. Based on this technique, we have proposed and demonstrated that in a tailored plasma structure, multi-millijoule energy, single-cycle, long-wavelength IR (3–20 μ m) pulses can be generated by using an 810 nm Ti:sapphire drive laser. Here, we extend this idea to the THz frequency regime. We show that sub-joule, terawatts, single-cycle terahertz (2–12 THz or 150–25 μ m) pulses can be generated by replacing the drive laser with a picosecond 10 μ m CO 2 laser and a different shaped plasma structure. The second plasma technique employs frequency upshifting by colliding a CO 2 laser with a rather sharp relativistic ionization front created by ionization of a gas in less than half cycle (17 fs) of the CO 2 laser. Even though the electrons in the ionization front carry no energy, the frequency of the CO 2 laser can be upshifted due to the relativistic Doppler effect as the CO 2 laser pulse enters the front. The wavelength can be tuned from 1 to 10 μ m by simply changing the electron density of the front. While the upshifted light with 5 < λ ( μ m ) < 10 propagates in the forward direction, that with 1 < λ ( μ m ) < 5 is back-reflected. These two plasma techniques seem extremely promising for covering the entire molecular fingerprint region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mid-infrared vertical cavity laser

Disclosed is an optically pumped vertical cavity laser structure operating in the mid-infrared region, which has demonstrated room-temperature continuous wave operation. This structure uses a periodic gain active region with type I quantum wells comprised of InGaAsSb, and barrier/cladding regions which provide strong hole confinement and substantial pump absorption. A preferred embodiment includes at least one wafer bonded GaAs-based mirror. Several preferred embodiments also include means for wavelength tuning of mid-IR VCLs as disclosed, including a MEMS-tuning element. This document also includes systems for optical spectroscopy using the VCL as disclosed, including systems for detection concentrations of industrial and environmentally important gases.

42 ENGINEERING↗

Mid-infrared vertical cavity laser

Disclosed is an optically pumped vertical cavity laser structure operating in the mid-infrared region, which has demonstrated room-temperature continuous wave operation. This structure uses a periodic gain active region with type I quantum wells comprised of InGaAsSb, and barrier/cladding regions which provide strong hole confinement and substantial pump absorption. A preferred embodiment includes at least one wafer bonded GaAs-based mirror. Several preferred embodiments also include means for wavelength tuning of mid-IR VCLs as disclosed, including a MEMS-tuning element. This document also includes systems for optical spectroscopy using the VCL as disclosed, including systems for detection concentrations of industrial and environmentally important gases.

Jayaraman, Vijaysekhar↗