Search NASASearch

SEARCH · Search NASA

Results for “Modulus Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

214 records · Page 2

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Methods and recommendations for large-scale deflagration testing of battery energy storage system enclosures

UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.

Gaudet, Benjamin [UL Solutions] (ORCID:00090006419

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)

Review of Shock, Vibration, and Other Tests for Type IV Hydrogen Composite Pressure Vessels for Rail Use

Requirements specific to hydrogen rail transportation and its unique components are currently not well represented in safety codes and standards. Notably, one of the most important components of the system, the hydrogen storage vessel, may be subject to entirely different shock and vibration conditions compared to hydrogen tanks on road vehicles. This report focuses on how composite hydrogen tanks are tested for performance and how this may relate to these tanks being used on rail systems. The shock and vibration testing procedures that are relevant for hydrogen composite tanks used for rail applications have been identified, as well as some general testing requirements for hydrogen tanks and composite tanks.

42 ENGINEERING

Sierra/SD Verification Test Manual 5.32

Tests from the Sierra Structural Dynamics verification test suite are reviewed. For each of the tests presented in this document the test setup, derivation of the analytic solution, and comparison of the Sierra code results to the analytic solution is provided. This document can be used to confirm that a given code capability is verified or referenced as a compilation of example problems.

Beale, Dagny Marie [Sandia National Laboratories (

Chevron Natural Gas Carbon Capture Technology Testing Project (Final Technical Report)

The objective of this project was to design, construct, commission, and operate an engineering scale post combustion carbon capture system to validate the technical maturity, operability, and scalability of Svante’s VeloxoTherm™ solid sorbent carbon capture technology under representative flue gas conditions. The project was executed at Chevron’s Kern River oil field in the San Joaquin Valley of California and evaluated carbon capture performance using slipstream flue gas from natural gas fired once through steam generators (OTSG), including indicative coal and natural gas combined cycle (NGCC) operating scenarios.

03 NATURAL GAS

Mu2e Production Target Thermal Test Project

The Mu2e experiment requires a production target that is capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Pro- duction Target by testing the Stickman model’s thermal behavior. Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to an- alyze thermal performance and pressure drop within the cold well and wa- ter cooling circuit. These calculations also determined the optimal sizing for key components of the water system. An engineering note was made to document these calculations. CAD models of the water circuit piping, thermocouple mounting bars, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on continued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Flores Luviano, Angel Augusto [Unlisted, US]

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]

Aerosol Can Fireball Tests: Commodity Hazards in the Transportation Environment Phase 1 Report

This report describes a series of tests performed at Sandia’s burn site to better understand the behavior of aerosol commodities and their hazards in the transportation environment. This comes on the tail of a prior study on the use cases and historical hazards associated with aerosol commodities in the shipping environment (Cambridge Systematics Incorporated, CSI, 2020). It is also mindful of the National Fire Protection Agency NFPA30B standard for safe warehousing of aerosol commodities. Warehousing is different from transit because warehousing typically involves active suppression and mitigation measures not practical or relevant to the shipping environment. Transit also typically involves tighter packing and smaller enclosure spaces. The transportation hazard space has not been heavily studied in prior testing specifically aimed towards the ground, rail, and nautical shipping environments.

54 ENVIRONMENTAL SCIENCES

Testing and Validation of Wireless Communication Architecture for Heliostat Fields: SIPS Final Report

This work focuses on the development and testing of a low-cost wireless communication system for heliostat fields, enabling significant capital costs reductions for concentrating solar thermal systems. Outputs of this work include a working demonstration of a multi-node communication system, clear reporting of system performance, and technical documentation of system development and architecture for reproducibility. Through this process, an open-source repository was created for manufacturing hardware at ~$30/heliostat. The system includes software for cybersecurity, achieving sub-second communication latencies and derisking of hardware for eventual scale-up to tens of thousands of heliostats. While the system is not currently off-the-shelf ready, there is now a clearly defined pathway for scaling up and completing the commercial development process.

14 SOLAR ENERGY

SAVY-4000 Finite-Element Drop Test Analysis

PFE Auxiliary Systems conducted drop testing on SAVY-4000 containers to evaluate structural response under 12-foot drop conditions. In support of that effort, a finite-element modeling capability was developed to simulate drop response across multiple container sizes and impact orientations. The purpose of this work was to provide a consistent analysis framework that could support interpretation of testing, compare response trends across multiple configurations, and generate quantities of interest for later comparison with experimental data. More broadly, the analysis and testing were intended to assess whether the containers continued to perform their primary function after a 12-foot drop, namely maintaining structural integrity and containment of the contents. The modeling approach combined an implicit preload analysis with an explicit drop simulation so that each drop event began from a mechanically realistic assembled condition, including compression of the silicone O-ring. Separate models were developed for 2-quart, 5-quart, 12-quart, and 10-gallon containers. The results were evaluated in terms of strain-gauge response, collar-lid gap behavior, and accumulated plastic strain. In addition, parametric studies were performed on the 2-quart container to assess sensitivity to O-ring stiffness, friction, canister thickness, geometry tolerance, and mesh density. The simulations showed that predicted drop responses depended strongly on both container size and drop orientation. Gap metrics identified cases in which the predicted collar-lid opening exceeded the nominal O-ring cross-section threshold, while plastic strain metrics identified localized regions of elevated permanent deformation. Parametric studies showed that the predicted response was especially sensitive to the assumed O-ring stiffness and contact friction, while the geometry tolerance study produced smaller changes in the cases examined. The main value of this work was that it established a repeatable modeling and simulation workflow to support drop-test implementation, evaluate effects of future configuration changes, and understand modeling assumptions that most influenced predicted response. At the current stage, the results were viewed as preliminary model predictions rather than validated predictions. The next step would be to compare drop-test data to the model so that predictive values of the workflow could be refined and used with greater confidence to assess whether the containers maintained structural integrity and containment of the contents after a 12-foot drop.

42 ENGINEERING

Gear Test Assembly - Experimental Testing and Analysis of Gears and Bearings - FY2026

The Gear Test Assembly (GTA) is an experimental test apparatus built and installed in the Mechanisms and Engineering Test Loop (METL) at Argonne National Laboratory (ANL). While designed to accommodate a variety of components intended for use in advanced compact in-vessel transfer machine, the focus of GTA been the testing of large radial spur gears. The performance of the components used in GTA motivates the choices made in the design, components, and material choices for the forthcoming METL test articles; the Gripper Test Assembly (GrTA), and the Bearing Test Assembly (BTA). To date, GTA has completed nine experimental testing campaigns and achieved over 21 million revolutions under prototypic sodium fast reactor loads and operating conditions. This report provides an overview and results for the two most recent experiments Campaign #8 and Campaign #9. `Campaign #8 was the first campaign to make use of a set of nickel alloy radial spur gears, made from Hastelloy C-22HS, and combined with heat-treated tapered roller bearings. The bearings and torque profile used allowed Campaign #8 to be directly compared with Campaign #1 where Inconel 718 gears were used instead. Campaign #8 attained 1,058,880 shaft revolutions within 23% of the 1,314,855 revolutions achieved in Campaign #1. These results demonstrate that the heat-treated tapered roller bearings show consistent increased lifetimes, approximately three times longer than for non heat-treated taper rollers, and that the particular material of the gear does not play a substantial role in performance. Similar to Campaign #7 where bearing failure resulted in fragmentation and transport of bearing material into the gear teeth led to tooth damage in the Inconel gears, a similar process led to the damage of the Hastelloy gears. Subsequent NDE analysis showed that the damage was only limited to the tooth surface and does not extend into the gear interiors. Based on the NDE reports, the Hastelloy gears can be reconditioned and put back into service for future campaigns as was done for the Inconel gears. Reconditioned Inconel 718 gears damaged in Campaign #7 were returned to service in Campaign #9 and paired with non heat-treated tapered roller bearings. In Campaign #9 a novel set of operating conditions were implemented whereby the gears and bearings were cycled between hot, submerged refueling conditions where fuel handling operations occurred and cold, dry, and inert conditions where the sodium was drained and the vessel was allowed to cool simulating long, ex-vessel storage of the fuel handling machine. A total of eight of these operating cycles were achieved before a bearing failure occurred after the accumulation of 475,692 shaft revolutions were achieved. During Campaign #9, one of the drive motors was damaged and over the course of a 240 day standby period, the entire GTA drive system was upgraded from a 480VAC system to a 240VAC system that provided the opportunity to consolidate wall-space in the METL facility and provide more space for additional test articles being installed in the coming year. The over 475,000 shaft revolutions achieved in Campaign #9 eclipses the previous record for lifetime of non heat-treated tapered roller bearings held by Campaign #3 of 392,000 shaft revolutions. Further analysis and future campaigns hope to shed light on the cause of this approximately 17% increase in lifetime.

42 ENGINEERING

From zonal to nodal capacity expansion planning: Spatial aggregation impacts on a realistic test-case

Solving power system capacity expansion planning (CEP) problems at realistic spatial resolutions is computationally challenging. Thus, a common practice is to solve CEP over zonal models with low spatial resolution rather than over full-scale nodal power networks. Due to improvements in solving large-scale stochastic mixed integer programs, these computational limitations are becoming less relevant, and the assumption that zonal models are realistic and useful approximations of nodal CEP is worth revisiting. Here, this work is the first to conduct a systematic computational study on the assumption that spatial aggregation can reasonably be used for ISO-scale CEP. By considering a realistic, large-scale test network based on the state of California with over 8000 buses, we find that well-designed small spatial aggregations can yield good approximations but that coarser zonal models may result in large distortions of investment decisions, e.g., capacity under-investment of up to 41% for the lowest resolution model considered.

24 POWER TRANSMISSION AND DISTRIBUTION