Interplanetary shocks seen by Ames plasma probe on Pioneer 6 and 7

Interplanetary shocks and discontinuities observed by the Ames Research Center plasma probe on Pioneer 6 and 7 are analyzed with Goddard Space Flight Center magnetometer data. Several shock normals are used for the MHD model of a shock where the mixed data shock normals, which use plasma and magnetic-field data, give the best agreement with the theoretical requirements. The requirements are the satisfaction of the Rankine-Hugoniot conservation equations across the shock where angles (predicted theoretically from the conservation equations) between certain combinations of plasma and magnetic-field data vectors in the shock normals are explicitly checked. The results for the August 29, 1966, shock are compared with previous results.

Abraham-Shrauner, B.

Laboratory plasma probe studies

Diagnostic experiments performed in a collisionless plasma using CO2 as the working gas are described. In particular, simultaneous measurements that have been performed by means of Langmuir- and RF-probes are presented. A resonance occurring above the parallel resonance in the frequency characteristic of a two electrode system is interpreted as being due to the resonant excitation of electroacoustic waves.

Heikkila, W. J.

Report of the Plasma Physics and Environmental Perturbation Laboratory (PPEPL) working groups. Volume 1: Plasma probes, wakes, and sheaths working group

It is shown in this report that comprehensive in-situ study of all aspects of the entire zone disturbance caused by a body in a flowing plasma resulted in a large number if requirements on the shuttle-PPEPL facility. A large amount of necessary in-situ observation can be obtained by adopting appropriate modes of performing the experiments. Requirements are indicated for worthwhile studies, of some aspects of the problems, which can be carried out effectively while imposing relatively few constraints on the early missions. Considerations for the desired growth and improvement of the PPEPL to facilitate more complete studies in later missions are also discussed. For Vol. 2, see N74-28170; for Vol# 3, see N74-28171.

Source record

Satellite probes plasma processes in earth orbit

The mission of the DOD/NASA Combined Release and Radiation Effects Satellite (CRRES) is to deepen understanding of the earth's near-space environment, including the radiation belts and the ionosphere; this will help spacecraft designers protect against radiation-belt particles that affect onboard electronics, solar panel arrays, and crewmembers. Attention is presently given to CRRES's study of ionospheric plasma processes through releases of Ba, Ca, Sr, and Li at altitudes of 400-36,000 km.

Christensen, Andrew B.

Comparison of plasma probes in the lower ionosphere

The instrumentation and the observations performed by four identically instrumented sounding rockets, designed to investigate the mesosphere and lower thermosphere, are reported. The four sounding rockets were launched from the Brazilian equatorial range Alcantara in August 1994. The instruments were capable of determining ion and electron densities. The results of data processing showed discrepancies hitherto unnoticed by other experiments.

Friedrich, M.

A microwave probe for plasma plumes.

Swinging-arm microwave probe to measure electron density and collision frequency profiles transverse to plasma jet plumes

MICROWAVE PLASMA PROBE

Measuring ionospheric electron density using the plasma frequency probe

During the past decade, the plasma frequency probe (PFP) has evolved into an accurate, proven method of measuring electron density in the ionosphere above about 90 km. The instrument uses an electrically short antenna mounted on a sounding rocket that is immersed in the plasma and notes the frequency where the antenna impedance is large and nonreactive. This frequency is closely related to the plasma frequency, which is a direct function of free electron concentration. The probe uses phase-locked loop technology to follow a changing electron density. Several sections of the plasma frequency probe circuitry are unique, especially the voltage-controlled oscillator that uses both an electronically tuned capacitor and inductor to give the wide tuning range needed for electron density measurements. The results from two recent sounding rocket flights (Thunderstorm II and CRIT II) under vastly different plasma conditions demonstrate the capabilities of the PFP and show the importance of in situ electron density measurements of understanding plasma processes.

Jensen, Mark D.

The impedance characteristic of a spherical probe in an isotropic plasma.

Experimental investigation of the impedance characteristic of a spherical plasma probe for a quantitative assessment of theoretical work, and of hydrodynamic or fluid theory in particular. A stable, low-temperature (about 500K) plasma was produced in nitrogen by a cold-cathode discharge, with a plasma frequency of the order of 15 MHz and with an electron collision frequency in the range from one to ten million per sec. Hydrodynamic probe theory was tested against the experimental results for the specific cases corresponding to the probe at floating potential and at space potential. Good agreement was obtained for both the real and imaginary parts. The real part of the impedance shows a peak near the plasma frequency, a small shift being explicable in terms of realistic sheath profiles. Electron density can thus be deduced rather accurately, and electron temperature approximately, on the basis of hydrodynamic theory. Accurate values of the electron-neutral collision frequency were also obtained for plasmas where the collision frequency was larger than 0.4 times the radian plasma frequency. At lower pressures the presence of collisionless or Landau damping was clearly established, and the more accurate kinetic theory is necessary to explain the experimental results.

Tarstrup, J.