Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLUTONIUM ISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Disposition of Newly Generated Transuranic Waste at ORNL - 20107

ORNL operates the High Flux Isotope Reactor, which provides a high neutron source for production of isotopes for medical, industrial, and nuclear research programs and is the US DoE's center for production, storage, and distribution for TRU isotopes (plutonium through californium). Operation of these facilities results in the generation of CH-TRU and RH-TRU waste for disposal at the WIPP. This paper describes the program ORNL is implementing in collaboration with the Carlsbad Field Office National TRU Program Difficult Waste Team to disposition newly generated TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis Report for Hydrolyzed UF 6 Samples

Under the auspices of the US Department of Energy/National Nuclear Security Agency’s Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory was tasked with analyzing two UF6 filled hoke tubes for uranium isotopic composition. This report documents the results of the measurements performed by the MSIS group’s International Organization for Standardization/International Electrotechnical Commission 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry, and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ORNL Report for Hydrolyzed UF 6 Samples 439451, 438792, 439144, 439616, and 439617

Under the auspices of the US Department of Energy/National Nuclear Security Agency’s Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory was tasked with analyzing five UF 6 filled P-10 tubes for uranium isotopic composition. This report documents the results of the measurements performed by the MSIS group’s International Organization for Standardization/International Electrotechnical Commission 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry, and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Small-scale production of bespoke accelerated aging plutonium alloy

Here, this study demonstrates the 100 g scale manufacture of a plutonium alloy that ages at an accelerated rate. The resulting alloy ages six times faster than typical weapons-grade plutonium due to the addition of 238 Pu. As a major innovation, the process involved using a partial direct oxide reduction technique. This method was achieved by developing a new, complex geometry stirrer using additive manufacturing to reduce the 238Pu oxide and efficiently incorporate it into weapons-grade plutonium metal. The material was then purified by molten salt extraction and electrorefining before being alloyed with gallium. The alloy was then cold-rolled and annealed in a homogenization heat treatment. The resulting disk was characterized by metallography and differential scanning calorimetry, and the impurity content was determined using analytical chemistry techniques. The results show that a homogeneous delta phase plutonium alloy was achieved with expected microstructure and minimal impurities. This study was also successful in changing the plutonium isotopic composition by incorporating additional 238 Pu to accelerate the effects of radiation damage. This enables researchers to study long-term aging phenomena in a reduced time frame, thus avoiding the need for large-scale material production and circumventing the limitations of using naturally aged, archived plutonium.

Aging theory↗

ORNL Report of Analysis for the Verification of NRMP CRM U030A

In support of the Certified Reference Material (CRM) program managed by the Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory (ORNL) was asked to prepare a set of CRM U030A units for use as standards for isotopic analysis using multicollector thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) instruments. This report documents the results of the verification measurements performed on three randomly selected units by the MSIS group’s ISO/IEC 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry [1], and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan [2].

Mathew, Kattathu [Oak Ridge National Laboratory (O↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Rapid Sequential Separation Method for Determination of Actinides and TENORM in Fracking Wastes - 20223

With recent advances in unconventional drilling technology in the US and around the world, the risks of environmental contamination and exposure due to technologically enhanced naturally occurring radioactive materials (TENORM) from fracking wastes have also surfaced. Although the Permian Basin (southeastern New Mexico, western Texas) has long been a modest producer of oil, the advent of fracking technology a decade ago turned it into hot property for producers. A 2018 assessment of undiscovered, technically recoverable continuous oil and gas resources by the U.S. Geological Survey estimates an average 46.3 billion barrels of oil and 281 trillion cubic feet of gas. This is likely to increase the use of unconventional drilling and TENORM generation. TENORM concentrations in oil and gas exploration and production waste can be several hundred to several thousand times higher than background TENORM concentrations. Both the thorium and uranium decay chains contribute to airborne radionuclides arising from the radon gas escaping the ground and subsequently decaying as airborne particulates. Additionally, radon decay products {sup 210}Pb and {sup 210}Po can build up in scale on the internal surfaces of oil and gas handling pipes and in sludge in refineries, becoming potential inhalation and ingestion hazards for workers. Furthermore, southeastern NM is also home to world's only licensed and operating transuranic nuclear waste repository, the DoE's Waste Isolation Pilot Plant (WIPP). Plutonium isotopes ({sup 239+240}Pu) and {sup 241}Am, are expected to account for more than 99% of the total radioactivity scheduled for disposal in the WIPP repository. Thus, an improved understanding of the environmental fate and transport of TENORM, liberated by unconventional drilling, is essential to assess how best to protect individuals and the environment. In this context, accurate measurement of TENORM and actinides in environmental and biological samples is essential. In this presentation, a new sequential method for the separation and pre-concentration of actinides (Pu, Am, Np) and TENORM (Po, U and Th) derived from oil and gas exploration is proposed. The TEVA method involves a rapid co-precipitation step to remove matrix interferences from the samples, followed by plutonium oxidation state adjustment to Pu (IV) and an incubation period of ∼ 1 hour at 50-60 deg. C to allow the resultant Po (II) to oxidize into Po(IV). The polonium, neptunium, thorium and plutonium are then separated on a TEVA column, while americium and uranium are separated on a TRU column. After separation, the alpha counting source was prepared by micro-precipitation with copper sulfide (CuS) for polonium and neodymium fluoride (NdF{sub 3}) for actinides. The efficiency and reliability of the procedures were tested by analyzing filter, drinking water and frack sand samples. The method is simple, robust and can be performed quickly with excellent removal of interferences, high chemical recovery and very good alpha peak resolution. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Application of a Density Law via Python for Aqueous Plutonium Nitrate

A predictive density tool has been developed in Python to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer Method and an empirical method were implemented into the tool, allowing for plutonium nitrate density calculations. Additionally, the Python tool can generate atom densities for a MCNP6.2 material card using the density from the selected method and directly the densities into a prepared MCNP6 input text file. The material card and density are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, plutonium isotope weight percentages and impurity concentrations. The Python tool has been validated and verified against the International Handbook of Evaluated Criticality Safety Benchmark Experiments to predict densities within a root mean square error of 1.0% for the Pitzer method and 1.8% for the empirical method. These errors in density were shown to lead to a ±0.5% error in MCNP6.2 calculated k effective for the Pitzer method and a ±1.7% error for the Empirical method. Simultaneous work is also being done at the University of New Mexico and Los Alamos National Laboratory to create a similar tool for plutonium chloride solutions, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also lead the way towards a better understanding of solution systems and potential relaxation in the conservatism of the current aqueous plutonium processing limits.

97 MATHEMATICS AND COMPUTING↗

A Python Tool for Aqueous Plutonium Nitrate Density Law Input Preprocessing in MCNP6

Here, this work develops a predictive density tool in Python, named Plutonium Nitrate Solutions (PuNS), to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer method and an empirical method were implemented into the PuNS tool to generate atom densities for use in MCNP6 material cards. These material cards are directly prepared into an MCNP6 input text file and are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, and plutonium isotope weight percentages. The PuNS tool is validated and verified against the International Criticality Safety Benchmark Evaluation Project Handbook experiments and is observed to predict densities within a root mean square error of 0.89% for the Pitzer method and 1.82% for the empirical method. These errors in density lead to up to 1569 pcm difference in MCNP6 calculated k eff for the Pitzer method and up to a 1751 pcm difference for the empirical method when compared to experimental benchmarks. Simultaneous work is also being performed at Los Alamos National Laboratory and the University of New Mexico to create a similar tool for plutonium chloride solutions, named Plutonium Chloride Solution, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also facilitate an improved understanding of solution systems and a potential relaxation in the conservatism of current aqueous plutonium processing criticality safety limits.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Data and Cross Section Testing Using ENDF/B-VIII.0

With the release of the Evaluated Nuclear Data File (ENDF)/B-VIII.0 library, nuclear criticality safety practitioners and engineers have access to the latest cross section sets available for their analyses. However, these cross sections must be rigorously tested and validated to ensure that the nuclear data are responsive to the needs of the individuals responsible for developing, implementing, and maintaining computational tools for criticality safety applications. Thus, the ENDF/B-VIII.0 library is tested and validated with a large collection of experiments that were vetted by the International Criticality Safety Benchmark Evaluation Project and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. A selection of benchmark experiments for use within the criticality safety community were prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Nuclear Energy and Fuel Cycle Division at Oak Ridge National Laboratory. The performance of the ENDF/B-VIII.0 library is assessed by using VALID models of benchmark experiments with the beta 12 version of SCALE 6.3 KENO V.a and KENO-VI Monte Carlo codes. The performance is compared with the results obtained from with the ENDF/B-VII.1 library. This report considers multigroup (MG) and continuous energy (CE) formats of the ENDF/B-VIII.0 and -VII.1 libraries. The benchmark experiments within VALID that validate the ENDF/B-VIII.0 library cover 15 broad system categories by using a range of fissile materials, uranium enrichments, plutonium isotopic vectors, and mixed uranium/plutonium systems. These forms are represented as metals, solutions, or various arrays of rods or plates that cover a variety of neutron energy spectra: thermal, fast, mixed, and intermediate. Over 600 cases were considered for use with the KENO V.a and KENO-VI codes with the ENDF/B-VIII.0 library. The results of the Monte Carlo comparison of ENDF/B-VIII.0 to ENDF/B-VII.1 with both KENO V.a and KENO-VI indicate that there is a less than 0.53% Δk difference between the bias of calculated k eff from the expected values. The CE ENDF/B-VIII.0 library results in smaller magnitude biases than the ENDF/B-VII.1 data for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-SOL-THERM, PU-SOL-THERM, and U233-MET-FAST systems, while the MG results yielded smaller magnitude biases for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-COMP-THERM, LEU-SOL THERM, MIX-COMP-FAST, and U233-MET-FAST systems. Most notable are the adjustments to the plutonium and 233 U cross section data, which has resulted in noticeably lower biases in the ENDF/B VIII.0 results for the mixed, plutonium, and 233 U systems. Results of the sensitivity data file comparison generated from TSUNAMI-3D for selected VALID cases for the ENDF/B-VIII.0 library indicate a very high level of agreement with correlation coefficients of the effect of nuclear data uncertainty on k eff (the c k integral parameter) all above 0.99. This indicates that cases with the ENDF/B-VIII.0 library would see very similar responses to any nuclear data errors or change as those with the ENDF/B-VII.1 library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dose reconstruction for plutonium-239 intakes at the Rocky Flats Plant

Purpose: The Rocky Flats (RF) Plant was a weapons manufacturing facility that operated from the early 1950s to 1989. Its primary missions were the production of plutonium (Pu) pits for thermonuclear weapons and the processing of retired weapons for Pu recovery. The purpose of this study was to estimate radiation doses to a cohort of 4499 RF workers from an intake of 239 Pu, the primary plutonium isotope handled at the site. Materials and methods: The latest biokinetic models of the International Commission on Radiological Protection, or site-specific variations of those models, were used to estimate 239 Pu intakes for each worker based on model fits to bioassay data often coupled with lung measurements. Results: Urinary excretion and lung retention data for most 239 Pu intakes could be fit reasonably well by a mixture of Pu dioxide and moderately soluble material. For some workers, better fits were obtained by application of other absorption types including Type S, 239 Pu nitrate, or pure 239 Pu dioxide, or by assuming intake via a wound. The lungs typically received the highest tissue doses, with fifty-year committed equivalent doses in the range of 0.5–1 Sv for 275 workers, 1–5 Sv for 115 workers, and greater than 5 Sv for 12 workers. Conclusions: RF was a unique site regarding a large number of lung measurements available for determining the appropriate absorption types for inhaled material. Further, this provided higher confidence in reconstructed 239 Pu doses than is generally gained from urinary data alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study of Pile-Up Effects in Decay Energy Spectroscopy

Pile-up is an unavoidable complication for cryogenic detectors with relatively large heat capacities and slow rise time, such as systems for decay energy spectroscopy employing large Au absorbers. We have simulated the spectral response of such slow cryogenic detectors using Monte-Carlo algorithms to investigate the effects of pile-up on absolute and relative activity measurements. We focus on the impact of non-distinguishable pile-up that occurs when the rising edges of two waveforms originating from different events overlap in time and are interpreted as a single event. This effect can not be readily identified and corrected in experimental data. We investigated two representative cases of absolute decay counting and plutonium isotopic analysis and find that pile-up can distort the reconstruction of both the absolute and relative activities. This Monte-Carlo methodology quantifies of pile-up effects and provides a systematic methodology for calculating corrective factors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multipole responses in fissioning nuclei and their uncertainties

Electromagnetic multipole responses are key inputs to model the structure, decay, and reactions of atomic nuclei. With the introduction of the finite amplitude method (FAM), large-scale calculations of the nuclear linear response in heavy deformed nuclei have become possible. This work provides a detailed study of multipole responses in actinide nuclei with Skyrme energy density functionals. We quantify both systematic and statistical uncertainties induced by the functional parametrization in FAM calculations. We also extend the FAM formalism to perform blocking calculations with the equal filling approximation for odd-mass and odd-odd nuclei, and analyze the impact of blocking configurations on the response. In conclusion, by examining the entire plutonium isotopic chain from the proton to the neutron drip line, we find a large variability of the response with the neutron number and study how it correlates with the deformation of the nuclear ground state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Additional Analysis of the 2H-Evaporator Wall Scale Sample HTF-17-57

Savannah River National Laboratory previously analyzed scale samples from both the wall and cone sections of the 242-16H Evaporator prior to chemical cleaning. The samples were analyzed for uranium and plutonium isotopes required for a Nuclear Criticality Safety Assessment of the scale removal process. The analysis of the scale samples found the material to contain crystalline nitrated cancrinite and clarkeite and significant amounts of mercury. Savannah River Remediation subsequently requested additional analyses on the samples. Inspection of the sample bottles revealed that no sample remained of the cone scale (HTF-17-56) while approximately 4 g of the wall scale sample (HTF-17-57) remained. The wall sample was subsequently ground with a mortar and pestle, at which time it was discovered that the sample contained a significant amount of liquid, metallic mercury. The portion of the sample that was not mercury was approximately 3 g. This portion of the sample was analyzed to determine the concentrations of selected radionuclides. The following radionuclide concentrations were measured: <9.6E+02 dpm/g H-3, 2.9E+02 dpm/g C-14, 5.6E+03 dpm/g Tc-99, and 1.6E+02 dpm/g I-129. Blank samples were also analyzed to evaluate sample contamination from the Shielded Cells environment. All blank sample results were below detectable limits. Due to the limited sample size and the anticipated low levels of the target radionuclides, no replicate sample analysis was conducted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updated Reference VTR Core for CD-1

A preliminary reference core design was previously developed for the Versatile Test Reactor. The main features are that it is a 300 MW th sodium-cooled fast reactor using ternary metallic fuel U-20Pu-10Zr and able to achieve peak fast fluxes (E n > 0.1 MeV) in excess of 4.0x10 15 n/cm 2 -s. The plutonium in the fuel was assumed to be “reactor grade”, with a fissile quality of about 72% (i.e., 239 Pu and 241 Pu comprise 72% of the plutonium isotopes), and the uranium was assumed to be low-enriched uranium with 5% 235 U. This preliminary core design has been used through the CD-0 phase of the VTR project. Progression of the work after CD-0 led to revising, updating and refining the reference VTR core design, based on considerations from the various VTR teams: fuel, experiment, safety, and plant design teams. The objective of this report is to summarize the various changes made and details added to the model, to provide a description of the updated reference VTR core design and of its performance characteristics. This includes the traditional reactor physics characteristics, fuel cycle details, reactivity coefficients, temperature distributions, control rod worths and shutdown requirements. All of these define the updated “reference VTR core” intended to be used through CD-1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE 6.2.4 Validation: Nuclear Criticality Safety

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook). More than 600 cases from this handbook have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the SCALE 6.2.4 code system is assessed using the VALID models of benchmark experiments. A range of nuclear cross section libraries based on Evaluated Nuclear Data File (ENDF)/B-VII.1 in both multigroup (MG) and continuous energy (CE) formats is considered. The critical experiments available to validate the KENO V.a code cover 15 broad categories of systems. These systems use a range of fissile materials, including a range of uranium enrichments, various plutonium isotopic vectors, and some mixed uranium/plutonium oxides. The physical forms of the fissile material also vary and are represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover fast, intermediate, mixed, and thermal spectra. Over 550 of the total cases use the KENO V.a code for the four nuclear data libraries considered in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ORNL Contributions to the ENDF/B-VIII.1 Library [Slides]

For uranium and plutonium isotopes, evaluation work is converging to a stable configuration with an overall satisfactory benchmark performance (more information on the validation tests after CSEWG). Strontium evaluation was included in the repository library and successfully tested by processing codes relative to an alternative quantification of the external function. Cerium covariance matrices were updated to address review comments on the magnitude of the uncertainty. For future uncertainty quantification, theoretical observables should be properly decoupled from current measured guidelines. Tests to correctly include LP (from resonance parameters) fitted to measured energy-averaged data are in progress. Current ENDF files contains experimental LP data.

07 ISOTOPE AND RADIATION SOURCES↗

$\overline{TKE}$ Parameterization and $\bar{v}$ Uncertainty Analysis for CGMF

Previous work was performed on tuning CGMF parameters for 235 U, 238 U, and Plutonium isotopes. Now work is being done to tune minor uranium isotopes. However, uranium isotopes like 232 U and 236 U have almost no experimental data. We are applying cross-isotope models to extrapolate and tune CGMF on isotopes that lack experimental data. There exist several internal CGMF physics quantities that affect the output of CGMF—multi-chance fission probability, excitation energy sharing, spin-cutoff factor, spin scaling, and fragment total kinetic energy to name a few. The mean fragment total kinetic energy, $\overline{TKE}$, is particularly interesting because of its strong anti-correlation with $\bar{v}$. We are most interested in the mean fragment total kinetic energy before neutron emissions. $\overline{TKE}$ is assumed to be pre-neutron emission unless otherwise stated. Currently in CGMF, the $\overline{TKE}$ model for 233,234,235,238 U are tuned independently to reproduce ν for the associated isotopes. In this report, we will tune a cross-isotope $\overline{TKE}$ model to experimental $\overline{TKE}$ data for 232,233,234,235,236,238 U. Because of the unreliable and sparse nature of $\overline{TKE}$ experimental data, future work will use more reliable experimental $\bar{v}$ data to infer the $\overline{TKE}$ model (and likely other internal CGMF parameters) for uranium isotopes. Such work has been performed previously using a sensitivity analysis and Kalman filter methods.

07 ISOTOPE AND RADIATION SOURCES↗