Search NASA⌕ Search

SEARCH · Search NASA

Results for “PWM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

FPGA implementation of high-frequency multiple PWM for variable voltage variable frequency controller

In this paper, we present the FPGA implementation of the multiple pulse width modulation (MPWM) signal generation with repetition of data segments, applied to the variable frequency variable voltage systems and specially at to the photovoltaic water pumping system, in order to generate a signal command very easily between 10 Hz to 60 Hz with a small frequency and reduce the cost of the control system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal Stress Reduction in Power Switching Devices Using Distributed Loss PWM Concept for Current Source Inverters

A new modulation scheme is proposed for current source inverters (CSIs) that reduces the variation and peak junction temperature in the CSIs' power devices. The distributed loss pulse-width modulation (DLM) concept is introduced and applied to traditional space vector modulation methods to develop modified modulation schemes that reduce the thermal stress on power devices. The device junction temperatures resulting from conventional and DLM schemes are compared. Simulation and experimental results confirm that the proposed DLM concept reduces thermal stress on the devices while maintaining the same high output current waveform quality compared to traditional CSI modulation schemes. The CSI power device lifetime (i.e., the number of cycles to failure) are estimated using the simulation and experimental results. The proposed DLM significantly increases the device lifetime (by 5 to 6 times) by reducing the junction temperature variation compared to the conventional modulations.

42 ENGINEERING↗

Optimal Variable Switching Frequency Scheme to Reduce Loss of Single-Phase Grid-Connected Inverter With Unipolar and Bipolar PWM

Reducing the power loss of a converter without increasing its volume or cost in hardware has always been a much sought-after but challenging goal. This article proposes a comprehensive variable switching frequency (VSF) scheme to improve the overall system efficiency while still meeting a given total harmonic distortion (THD) requirement without any hardware changes, achieved only by changes to the controller. In this article, it is analyzed that for the H-bridge inverter, the inductor copper loss and the switch conduction loss are independent of the switching frequency (SF), while the device switching loss and the inductor core loss are functions of the SF. This article aims at weighting the combined switching loss and inductor core loss for both the unipolar and bipolar modulation techniques, with the constraint on the output THD, which, for fixed passive components, is a function of inductor ripple current that in turn depends on the SF. An optimal VSF scheme is devised through rigorous mathematical analysis of the output ripple component and the SF-dependent losses. In each switching cycle, the inductor ripple current is predicted with the circuit parameters, such as duty cycle, switching period, inductance, and dc voltage, and by implementing the VSF scheme, the current ripple is optimally varied such as to satisfy the THD requirement while reducing the SF-dependent losses. A generalized method to design VSF schemes for any topology and specifications is also presented, which would help future users in designing the VSF controller. A 1-kW H-bridge inverter using SiC MOSFETs and powdered iron/ferrite core has been built to validate the theoretical analysis. Both constant SF (CSF) scheme (200 kHz) and optimal VSF scheme with simple controller modification have been implemented in the experimental prototype using DSP TMS320f28335. Compared with the CSF scheme, the optimal VSF scheme shows a significant improvement in the system efficiency at rated power from 94.7%...

conduction loss↗

On Zero Steady-State Error Voltage Control of Single-Phase PWM Inverters With Different Load Types

This paper comprehensively investigates and compares different multiloop linear control schemes for single-phase pulsewidth modulation inverters, both in stationary and synchronous (d-q) frames, by focusing on their steady-state error under different loading conditions. Specifically, it is shown how proportional plus resonant (P + R) control and load current feedback (LCF) control can, respectively, improve the steady-state and transient performance of the inverter, leading to the proposal of a PID + R + LCF control scheme. Furthermore, the LCF control and capacitive current feedback control schemes are shown to be subject to stability issues under second and higher order filter loads. Additionally, the equivalence between the stationary frame and d-q frame controllers is discussed depending on the orthogonal term generation method, and a d-q frame voltage control strategy is proposed eliminating the need for the generation of this orthogonal component. This is achieved while retaining all the advantages of operating in the synchronous d-q frame, i.e., zero steady-state error and ease of implementation. All theoretical findings are validated experimentally using a 1.5 kW laboratory prototype.

42 ENGINEERING↗

A Six-Phase Space Vector PWM Technique for Wide Bandgap Device-Based Three-Level Inverters

This article presents a space vector pulsewidth modulation (SVPWM) technique for wide bandgap (WBG) device-based three-level (3L) six-phase inverters. Implementation of the SVPWM techniques for any six-phase inverter is complex for its high number of possible voltage vectors. Different six-phase load configurations are also possible depending on the angle between two consecutive phases and neutral point connections. The implementation techniques change depending on the load configuration. Moreover, a common neutral point for all six phases leads to circulating currents. Capacitor voltage balancing is also needed for 3L inverters. Capacitor voltage balancing and addressing the circulating current problem further increases the implementation complexity. In this article, a generalized SVPWM technique is proposed for the six-phase 3L inverters that is implementable using two three-phase 3L SVPWM blocks. The SVPWM technique also ensures dc bus capacitor voltage balancing and minimizes circulating current. Here, the SVPWM technique is experimentally verified using a GaN-based 3L six-phase active neutral point clamped (ANPC) inverter prototype, and the results are presented in this article.

42 ENGINEERING↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

Voltage control utilizing multiple PWM patterns

A power-delivery system may comprise a load device and a direct-current converter configured to deliver current to the load device when the direct-current converter is in an on state. The power-deliver system may comprise a voltage-measurement system configured to measure, at a beginning of each measurement cycle in a cyclic measurement pattern, a voltage at the load device. The power-deliver system may comprise a power controller configure to receive, at the beginning of each measurement cycle, the measurement of the voltage, and to perform, at the beginning of a control cycle in a cyclic control pattern, a voltage-control decision in response to a change in the measurement of the voltage being below a voltage-change threshold. The voltage-control decision may comprise whether to switch the state of the first direct-current converter. The cyclic control pattern may operate at a first frequency, and the measurement pattern may operate at a second frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage control utilizing multiple PWM patterns

A power-delivery system may comprise a load device and a direct-current converter configured to deliver current to the load device when the direct-current converter is in an on state. The power-deliver system may comprise a voltage-measurement system configured to measure, at a beginning of each measurement cycle in a cyclic measurement pattern, a voltage at the load device. The power-deliver system may comprise a power controller configure to receive, at the beginning of each measurement cycle, the measurement of the voltage, and to perform, at the beginning of a control cycle in a cyclic control pattern, a voltage-control decision in response to a change in the measurement of the voltage being below a voltage-change threshold. The voltage-control decision may comprise whether to switch the state of the first direct-current converter. The cyclic control pattern may operate at a first frequency, and the measurement pattern may operate at a second frequency.

Ferencz, Andrew↗

An Ultra-Fast Inrush-Current-Free Startup Method for Grid-tie Inverter without Voltage Sensors

This paper proposes an ultra-fast inrush-currentfree startup method for grid-tie inverters without voltage sensors and phase-locked loop (PLL). Traditionally, the grid-tie inverter needs the voltage measured from points of common couplings (PCC) to generate the phase angle via PLL for inverter pulsewidth- modulation (PWM) signals. The startup procedure is slow and inrush current occurs if the initial PWM does not match the unknown grid voltage well. This paper proposes a startup method that only uses measured inverter ac currents to generate the initial PWM by controlling the current to zero. The generated PWM pattern can be used to reproduce the real grid voltage regardless of the grid impedance. The zero-crossing points of the grid voltage are detected and then used for grid synchronization. The proposed startup procedure only needs a few cycles (16.67 ms/cycle) to reliably synchronize the inverter to the grid without any inrush current. Simulation and experimental results are presented to verify the effectiveness of this control strategy.

He, Yuchen↗

Dithering Digital Ripple Correlation Control for Photovoltaic Maximum Power Point Tracking

This study demonstrates a new method for rapid and precise maximum power point tracking in photovoltaic (PV) applications using dithered PWM control. Constraints imposed by efficiency, cost, and component size limit the available PWM resolution of a power converter, and may in turn limit the MPP tracking efficiency of the PV system. In these scenarios, PWM dithering can be used to improve average PWM resolution. In this study, we present a control technique that uses ripple correlation control (RCC) on the dithering ripple, thereby achieving simultaneous fast tracking speed and high tracking accuracy. Moreover, the proposed method solves some of the practical challenges that have to date limited the effectiveness of RCC in solar PV applications. We present a theoretical derivation of the principles behind dithering digital ripple correlation control, as well as experimental results that show excellent tracking speed and accuracy with basic hardware requirements.

Barth, C↗

System and method for determining stator winding resistance in an AC motor using motor drives

A system and method for determining the stator winding resistance of AC motors is provided. The system includes an AC motor drive having an input connectable to an AC source and an output connectable to an input terminal of an AC motor, a pulse width modulation (PWM) converter having switches therein to control current flow and terminal voltages in the AC motor, and a control system connected to the PWM converter. The control system generates a command signal to cause the PWM converter to control an output of the AC motor drive corresponding to an input to the AC motor, selectively generates a modified command signal to cause the PWM converter to inject a DC signal into the output of the AC motor drive, and determines a stator winding resistance of the AC motor based on the DC signal of at least one of the voltage and current.

42 ENGINEERING↗

Harmonic Analysis of Common-mode Reduction Modulation for Three-level Inverter

This paper presents harmonic analysis of common-mode reduction (CMR) modulation for three-level voltage source inverters. The analytical model to calculate the harmonics of CMR modulation with arbitrary PWM sequence is developed. The impact of alternative PWM sequences of CMR modulation on harmonics is investigated. New three-state and four-state PWM sequences of CMR are proposed which spread the energy centered in the carrier frequency in the conventional CMR, and thus reduce the voltage peaks in frequency domain. Experiments are conducted on a three-level neutral point clamped inverter. Experiment results verify the developed analytical model and harmonic analysis.

Chen, Ruirui↗