Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle image velocimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Plug20 Test Report: Particle Image Velocimetry (PIV) Measurements

This report provides turbulent flow statistics made using particle image velocimetry (PIV) for several internally mixed exhaust systems with external plugs (Plug20 designs). The tests were conducted at the NASA Glenn Research Center’s Aero-Acoustic Propulsion Laboratory (AAPL) in May and June 2022. The corresponding acoustic data for the configurations and flows presented in this report can be found in an earlier Technical Memorandum, NASA/TM-20210010291, “Plug20 Test Report.” The Plug20 nozzle family was designed to represent commercial supersonic vehicles in the 2025 to 2035 timeframe with a bypass ratio around 4, having an internal mixer, with and without an external plug to improve nacelle boattail drag and shock. The flow conditions measured represent engine cycles for commercial supersonic aircraft at takeoff, having pressure ratios of 2.0 and heated fan and core streams, measured both with and without a flight stream surrounding the plume. A few unheated flow conditions were also tested to tie results to other baseline test results. The PIV measurements in both streamwise and cross-stream planes are described, along with brief analysis to visually catalog the contents and confirm their validity. In this analysis, the streamwise PIV is found to match benchmark datasets within its experimental error. However, the cross-stream turbulent quantities measured by two systems do not match each other or the streamwise measurements in amplitude—caution is required when using the cross-stream data. Data acquired and included in this report are (1) velocity statistics of the plumes in both a streamwise and several cross-stream planes, and (2) the hot nozzle geometry. Tabular forms of the data and computer-aided design (CAD) files of the hot geometry are presented as supplemental files described in Appendix A (TM-20230006779SUPPL1.zip) and Appendix B (TM-20230006779SUPPL2.zip).

Turbulence↗

Synchrotron X-ray based particle image velocimetry to measure multiphase streamflow and densitometry

Synchrotron-based radiation techniques are increasingly used in the field of flow condition measurements. As a complicated multiphase flow, cavitation has been investigated in a wide variety of industrial fields, to prevent damages on spillways at large dams or intensify the bacteria eradication rate during water treatments. To control the detrimental effects of cavitating flows, the dynamics of and mechanisms affecting cavitation development shall be visualized and identified in real-time. Due to the large reflection and scattering effects of multiphase flow, standard visible-light imaging technologies cannot penetrate vapor bubbles and provide extremely limited information. In this study, the synchrotron source emitted high-flux X-ray pulses are used to capture flow motion and visualize internal structures with sufficiently high spatial and temporal resolutions. The image processing procedures on raw x-ray images are developed using 2D Fourier transform (FT) and wavelet transform (WT) to implement the contrast enhancement and de-noising. Through the edge detection algorithm, tracking either seeded particles or phase interfaces inside the opaque multiphase flow can be achieved to perform the particle image velocimetry. Further, with decomposing particle-only and particle-eliminated subplots from the X-ray phase-contrast image, the time-resolved velocity and void fraction fields are obtained simultaneously, paving a way for further flow condition analysis such as densitometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Holographic particle image velocimetry measurements in a rectangular jet

The development and testing of a holographic technique capable of measuring the three velocity components in selected regions of the flow field are described. Several techniques, including laser Doppler velocimetry, hot wire and particle image velocimetry (PIV) are commonly used to measure a flow field. The advantage of the PIV technique is that it provides instantaneous measurements in a selected plane of the flow field. The aim is to extend the conventional two dimensional PIV technique to simultaneously record several planes by means of the holographic technique. In the holographic technique, parallel laser sheets are used to increase the intensity of the light in specific planes of the flow field. Particles as small as 5 microns can be recorded.

VanEck, A.↗

Lensless Particle Image Velocimetry

The application of lensless imaging to particle image velocimetry (PIV) is demonstrated. Lensless PIV eliminates the need for imaging lenses to measure flow fields near a surface. Only the camera sensor, a thin mask, and computations are required to image particles in a flow field and to compute the velocity field. The small form factor could enable embedded sensors for near-wall measurements. Flow field measurements are obtained simultaneously for a lensless system and lens-based 2D PIV system, and several different reconstruction techniques are demonstrated. The reconstructed particle images and computed velocity fields compare well for both a uniform and shear flow. The potential for stereo and 3D volumetric PIV with a single camera sensor is demonstrated through different image reconstruction approaches.

Lensless imaging↗

Particle image velocimetry analysis with simultaneous uncertainty quantification using Bayesian neural networks

Particle image velocimetry (PIV) is an effective tool in experimental fluid mechanics for extracting flow fields from images. Recently, convolutional neural networks (CNNs) have been used to perform PIV analysis with accuracy on par with classical methods. Here we extend the use of CNNs to analyze PIV data while providing simultaneous uncertainty quantification on the inferred flow field. The method we apply in this paper is a Bayesian convolutional neural network (BCNN) which learns distributions of the CNN weights through variational Bayes. In order to demonstrate the utility of BCNNs for the PIV task, we compare the performance of three distinct BCNN models with simple architectures. The first network estimates flow velocity from image interrogation regions only. Our second model learns to infer velocity from both the image interrogation regions and interrogation region cross-correlation maps. Finally, our best performing network infers velocities from interrogation region cross-correlation maps only. We find that BCNNs using interrogation region cross-correlation maps as inputs perform better than those using interrogation windows only as inputs and discuss reasons why this may be the case. Additionally, we test the best performing BCNN on a full synthetic test image pair and a real image pair from the 1st International PIV Challenge. We show that ~98% of true particle displacements from the full synthetic image pair can be captured within the BCNN's 95% confidence intervals, and that the BCNN's performance on the real image pair is quantitatively similar to that of algorithms tested in the 1st International PIV Challenge. Finally, we show that BCNNs can be generalized to be used with multi-pass PIV algorithms with a moderate loss in accuracy, which may be overcome by future work on finetuning and training schemes. So to our knowledge, this is the first use of Bayesian neural networks to perform PIV.

47 OTHER INSTRUMENTATION↗

Analysis of Particle Image Velocimetry (PIV) Data for Application to Subsonic Jet Noise Studies

Global velocimetry measurements were taken using Particle Image Velocimetry (PIV) in the subsonic flow exiting a 1 inch circular nozzle in an attempt to better understand the turbulence characteristics of its shear layer region. This report presents the results of the PIV analysis and data reduction portions of the test and details the processing that was done. Custom data analysis and data validation algorithms were developed and applied to a data ensemble consisting of over 750 PIV 70 mm photographs taken in the 0.85 mach flow facility. Results are presented detailing spatial characteristics of the flow including ensemble mean and standard deviation, turbulence intensities and Reynold's stress levels, and 2-point spatial correlations.

Blackshire, James L.↗

Tip-Clearance Vortex Characterized With Three-Dimensional Digital Particle Image Velocimetry

An optical measurement technique known as Three-Dimensional Digital Particle Image Velocimetry (3-D DPIV) was used to characterize the tip clearance flow in NASA Glenn Research Center's low-speed axial compressor. 3-D DPIV is a technique in which a stereoscopic imaging system consisting of two cross-correlation cameras is used to record particles entrained in a flow as a laser light sheet is pulsed at two instances in time. Although 3-D DPIV has been used elsewhere, this is the first time it has been used to measure compressor tip clearance flows. In-house modifications of the DPIV system include the use of effective seeding technology and a novel system to perform a priori calibrations at all five measurement planes, greatly reducing facility run time. Computational fluid dynamics predictions, which are used to guide design changes toward improving the efficiency and operating range of turbomachinery, can be verified and improved by comparison with 3-D DPIV measurements of the actual tip clearance flow. This measurement campaign dealt with the characterization of the tip clearance vortex in the first stage of a four-stage axial compressor. The tip clearance vortex is formed in compressors operating with a clearance gap between the moving rotor blade tips and the stationary casing when a leakage flow, forced from the pressure side of the blade over the blade tip, forms a vortical structure on the suction side of the blade. 3-D DPIV is ideally suited to measure the clearance vortex for two reasons: (1) this technique captures the entire blade passage flow at one instant in time, so that wandering of the vortex during the measurement does not smear out velocity gradients in the flow field, and (2) the spanwise component of velocity changes sign across the vortex core, providing a more accurate measurement of the vortex location than was available with previous two-dimensional measurement approaches. These two attributes of the data will enable computational fluid dynamics researchers to validate their predictions to a level of accuracy not previously attainable. In an effort to understand the effects of this flow phenomenon on the operation of the low speed axial compressor, data were acquired at two mass flow coefficients: 0.395 (design operating point) and 0.35 (operating point just above stall). In order to identify the spatial extent, location, and magnitude of the tip clearance vortex for each mass flow condition, data were acquired at five equally spaced spanwise locations, from 90- to 100-percent span. The data presented shows a cross section of the tip clearance vortex at 94-percent span and a mass flow coefficient of 0.395, where the color contours represent the radial velocity component. The blue (flow towards the hub) and red (flow towards the casing) regions illustrate the extent of the tip clearance vortex. The interface between the blue and red regions delineates the location of the vortex core.

John, W. Trevor↗

Particle Image Velocimetry and Total Temperature Characterization of Arc-Heated Mach 4.5 Free Jet

Particle image velocimetry (PIV) measurements were conducted in the Arc-Heated Combustion Tunnel (ACT-II) on a high-enthalpy Mach 4.5 nozzle flow. The primary motivation for the current work is to establish the feasibility of PIV as a high-quality flow diagnostic technique in hypersonic arc-heated flows and produce a high-resolution hypersonic nozzle flow characterization, including nozzle free jet shear layer velocity profiles. Due to the uncertain nature of the gas composition in the flowfield of interest, PIV measurements of a supersonic wedge flow were used to couple the flow velocities to the oblique shock relations. This enabled a PIV-derived total temperature calculation that does not require a priori assumptions of the exact gas composition. A PIV expansion module was developed for this study, and proper seed sizing and material were selected for the present flow. An analysis of the seed particle response from the PIV measurements provided an initial validation of the seed performance while revealing potential issues with consistent seed sizing. These measurements and derived conditions represent a means of acquiring high-resolution velocimetry and temperature datasets that consider uncertainties in the experimental generation of hypersonic high-enthalpy flows.

Engineering↗

Analysis of Particle Image Velocimetry (PIV) Data for Acoustic Velocity Measurements

Acoustic velocity measurements were taken using Particle Image Velocimetry (PIV) in a Normal Incidence Tube configuration at various frequency, phase, and amplitude levels. This report presents the results of the PIV analysis and data reduction portions of the test and details the processing that was done. Estimates of lower measurement sensitivity levels were determined based on PIV image quality, correlation, and noise level parameters used in the test. Comparison of measurements with linear acoustic theory are presented. The onset of nonlinear, harmonic frequency acoustic levels were also studied for various decibel and frequency levels ranging from 90 to 132 dB and 500 to 3000 Hz, respectively.

Blackshire, James L.↗

Microvascular Branching as a Determinant of Blood Flow by Intravital Particle Imaging Velocimetry

The effects of microvascular branching on blood flow were investigated in vivo by microscopic particle imaging velocimetry (micro-PIV). We use micro-PIV to measure blood flow by tracking red blood cells (RBC) as the moving particles. Velocity flow fields, including flow pulsatility, were analyzed for the first four branching orders of capillaries, postcapillary venules and small veins of the microvascular network within the developing avian yolksac at embryonic day 5 (E5). Increasing volumetric flowrates were obtained from parabolic laminar flow profiles as a function of increasing vessel diameter and branching order. Maximum flow velocities increased approximately twenty-fold as the function of increasing vessel diameter and branching order compared to flow velocities of 100 - 150 micron/sec in the capillaries. Results from our study will be useful for the increased understanding of blood flow within anastomotic, heterogeneous microvascular networks.

Parsons-Wingerter, Patricia↗

Methodology for the Elimination of Reflection and System Vibration Effects in Particle Image Velocimetry Data Processing

A methodology to eliminate model reflection and system vibration effects from post processed particle image velocimetry data is presented. Reflection and vibration lead to loss of data, and biased velocity calculations in PIV processing. A series of algorithms were developed to alleviate these problems. Reflections emanating from the model surface caused by the laser light sheet are removed from the PIV images by subtracting an image in which only the reflections are visible from all of the images within a data acquisition set. The result is a set of PIV images where only the seeded particles are apparent. Fiduciary marks painted on the surface of the test model were used as reference points in the images. By locating the centroids of these marks it was possible to shift all of the images to a common reference frame. This image alignment procedure as well as the subtraction of model reflection are performed in a first algorithm. Once the images have been shifted, they are compared with a background image that was recorded under no flow conditions. The second and third algorithms find the coordinates of fiduciary marks in the acquisition set images and the background image and calculate the displacement between these images. The final algorithm shifts all of the images so that fiduciary mark centroids lie in the same location as the background image centroids. This methodology effectively eliminated the effects of vibration so that unbiased data could be used for PIV processing. The PIV data used for this work was generated at the NASA Langley Research Center Quiet Flow Facility. The experiment entailed flow visualization near the flap side edge region of an airfoil model. Commercial PIV software was used for data acquisition and processing. In this paper, the experiment and the PIV acquisition of the data are described. The methodology used to develop the algorithms for reflection and system vibration removal is stated, and the implementation, testing and validation of these algorithms are presented.

Bremmer, David M.↗

Digital Particle Image Velocimetry (DPIV) Used for Space-Time Correlations in Nozzle Flow

An optical measurement technique known as Digital Particle Image Velocimetry (DPIV) was used previously to characterize the first- and second-order statistical properties of both cold and hot jet flows from externally mixed nozzles in NASA Glenn Research Center's Nozzle Acoustic Test Rig. In this technique, an electronic camera records particles entrained in a flow as a laser light sheet is pulsed at two instances in time. Correlation processing of the recorded particle image pairs yields the two-component velocity field across the imaged plane of the flow. The information acquired using DPIV is being used to improve our understanding of the decay of turbulence in jet flows-a critical element for understanding the acoustic properties of the flow. Recently, two independent DPIV systems were installed in Glenn's Small Hot Jet Acoustic Rig, enabling multiplane correlations in time and space. The data were collected over a range of different Mach numbers and temperature ratios. DPIV system 1 was fixed to a large traverse rig, and DPIV system 2 was mounted on a small traverse system mounted on the large traverse frame. The light sheets from the two DPIV systems were aligned to lie in the same axial plane, with DPIV system 2 being independently traversed downstream along the flow direction. For each measurement condition, the DPIV systems were started at a fully overlapping orientation. A polarization separation technique was used to avoid cross-talk between the two systems. Then, the DPIV systems fields were shifted axially apart, in successively increasing steps. The downstream DPIV system 2 was triggered at a short time delay after the upstream DPIV system 1, where the time delay was proportional to the convective flow velocity in the shear layer of the jet flow and the axial separation of the two DPIV systems. The acquired data were processed to obtain the instantaneous velocity vector maps over a range of time delays and spatial separations. The velocity fields from the different DPIV systems were then cross-correlated to determine the degree of correlation remaining in the flow as the downstream convection distance was increased. The new data provide Lagrangian measurements of the convective turbulent structures in the shear layer of an exhaust nozzle. These measurements, obtained in both cold and hot flows, will be used to validate and correct models for space-time velocity correlations-long a missing key to predicting jet noise.

Wernet, Mark P.↗

Particle Image Velocimetry Measurements of a Two/Three-dimensional Separating/Reattaching Boundary Layer Downstream of an Axisymmetric Backward-facing Step

Planar Particle Image Velocimetry measurements were obtained in the separating/reattaching flow region downstream of an axisymmetric backward-facing step. Data were acquired for a two-dimensional (2D) separating boundary layer at five different Reynolds numbers based on step height (Re(sub h)), spanning 5900-33000, and for a three-dimensional (3D) separating boundary layer at Re(sub h) = 5980 and 8081. Reynolds number effects were investigated in the 2D cases using mean-velocity field, streamwise and wall-normal turbulent velocity, and Reynolds stress statistics. Results show that both the reattachment length (x(sub r)) and the secondary separation point are Reynolds number dependent. The reattachment length increased with rising Re(sub h) while the secondary recirculation region decreased in size. These and other Re(sub h) effects were interpreted in terms of changes in the separating boundary layer thickness and wall-shear stress. On the other hand, in the 3D case, it was found that the imposed cross-flow component was relatively weak in comparison to the streamwise component. As a result, the primary influences of three dimensionality only affected the near-separation region rather than the entire separation bubble.

Hudy, Laura M.↗

A survey of particle image velocimetry applications in Langley aerospace facilities

This paper describes several applications of the global velocity measurement technique known as particle image velocimetry to three different facilities at Langley Research Center. These three applications represent global velocity measurements in distinctly different flows, namely a reacting hydrogen - air flame, a low Reynolds number boundary layer, and hypersonic flow over a wedge. In addition, these applications illustrate the power of the instrument to obtain data such as vorticity and Reynolds stress. Finally, the ability to obtain particle dynamics data in supersonic/hypersonic flows similar to that which can be obtained with point measurement techniques is demonstrated.

Humphreys, W. M.↗

Stereo Particle Image Velocimetry Measurements of Transition Downstream of a Backward-Facing Step in a Swept-Wing Boundary Layer

Stereo particle image velocimetry measurements were performed downstream of a backward-facing step in a stationary-cross flow dominated flow. The PIV measurements exhibit excellent quantitative and qualitative agreement with the previously acquired hotwire data. Instantaneous PIV snapshots reveal new information about the nature and cause of the \spikes" that occurred prior to breakdown in both the hotwire and PIV data. The PIV snapshots show that the events occur simultaneously across multiple stationary cross flow wavelengths, indicating that this is not simply a local event, but is likely caused by the 2D Tollmien-Schlichting instability that is introduced by the step. While the TS instability is a 2D instability, it is also modulated in the spanwise direction due to interactions with the stationary cross flow, as are the other unsteady disturbances present. Because of this modulation, the "spike" events cause an instantaneous increase of the spanwise modulation of the streamwise and spanwise velocity initially caused by the stationary cross flow. Breakdown appears to be caused by this instantaneous modulation, possibly due to a high-frequency secondary instability similar to a traveling-cross flow breakdown scenario. These results further illuminate the respective roles of the stationary cross flow and unsteady disturbances in transition downstream of a backward-facing step.

Eppink, Jenna L.↗

Stereo Particle Image Velocimetry Measurements of Transition Downstream of a Forward-Facing Step in a Swept-Wing Boundary Layer

Stereo particle image velocimetry measurements were performed downstream of a forward-facing step in a stationary-crossflow dominated flow. Three different step heights were studied with the same leading-edge roughness configuration to determine the effect of the step on the evolution of the stationary-crossflow. Above the critical step height, which is approximately 68% of the boundary-layer thickness at the step, the step caused a significant increase in the growth of the stationary crossflow. For the largest step height studied (68%), premature transition occurred shortly downstream of the step. The stationary crossflow amplitude only reached approximately 7% of U(sub e) in this case, which suggests that transition does not occur via the high-frequency secondary instabilities typically associated with stationary crossflow transition. The next largest step of 60% delta still caused a significant impact on the growth of the stationary crossflow downstream of the step, but the amplitude eventually returned to that of the baseline case, and the transition front remained the same. The smallest step height (56%) only caused a small increase in the stationary crossflow amplitude and no change in the transition front. A final case was studied in which the roughness on the leading edge of the model was enhanced for the lowest step height case to determine the impact of the stationary crossflow amplitude on transition. The stationary crossflow amplitude was increased by approximately four times, which resulted in premature transition for this step height. However, some notable differences were observed in the behavior of the stationary crossflow mode, which indicate that the interaction mechanism which results in the increased growth of the stationary crossflow downstream of the step may be different in this case compared to the larger step heights.

Eppink, Jenna L.↗

Symmetric Phase-Only Filtering in Particle-Image Velocimetry

Symmetrical phase-only filtering (SPOF) can be exploited to obtain substantial improvements in the results of data processing in particle-image velocimetry (PIV). In comparison with traditional PIV data processing, SPOF PIV data processing yields narrower and larger amplitude correlation peaks, thereby providing more-accurate velocity estimates. The higher signal-to-noise ratios associated with the higher amplitude correlation peaks afford greater robustness and reliability of processing. SPOF also affords superior performance in the presence of surface flare light and/or background light. SPOF algorithms can readily be incorporated into pre-existing algorithms used to process digitized image data in PIV, without significantly increasing processing times. A summary of PIV and traditional PIV data processing is prerequisite to a meaningful description of SPOF PIV processing. In PIV, a pulsed laser is used to illuminate a substantially planar region of a flowing fluid in which particles are entrained. An electronic camera records digital images of the particles at two instants of time. The components of velocity of the fluid in the illuminated plane can be obtained by determining the displacements of particles between the two illumination pulses. The objective in PIV data processing is to compute the particle displacements from the digital image data. In traditional PIV data processing, to which the present innovation applies, the two images are divided into a grid of subregions and the displacements determined from cross-correlations between the corresponding sub-regions in the first and second images. The cross-correlation process begins with the calculation of the Fourier transforms (or fast Fourier transforms) of the subregion portions of the images. The Fourier transforms from the corresponding subregions are multiplied, and this product is inverse Fourier transformed, yielding the cross-correlation intensity distribution. The average displacement of the particles across a subregion results in a displacement of the correlation peak from the center of the correlation plane. The velocity is then computed from the displacement of the correlation peak and the time between the recording of the two images. The process as described thus far is performed for all the subregions. The resulting set of velocities in grid cells amounts to a velocity vector map of the flow field recorded on the image plane. In traditional PIV processing, surface flare light and bright background light give rise to a large, broad correlation peak, at the center of the correlation plane, that can overwhelm the true particle- displacement correlation peak. This has made it necessary to resort to tedious image-masking and background-subtraction procedures to recover the relatively small amplitude particle-displacement correlation peak. SPOF is a variant of phase-only filtering (POF), which, in turn, is a variant of matched spatial filtering (MSF). In MSF, one projects a first image (denoted the input image) onto a second image (denoted the filter) as part of a computation to determine how much and what part of the filter is present in the input image. MSF is equivalent to cross-correlation. In POF, the frequency-domain content of the MSF filter is modified to produce a unitamplitude (phase-only) object. POF is implemented by normalizing the Fourier transform of the filter by its magnitude. The advantage of POFs is that they yield correlation peaks that are sharper and have higher signal-to-noise ratios than those obtained through traditional MSF. In the SPOF, these benefits of POF can be extended to PIV data processing. The SPOF yields even better performance than the POF approach, which is uniquely applicable to PIV type image data. In SPOF as now applied to PIV data processing, a subregion of the first image is treated as the input image and the corresponding subregion of the second image is treated as the filter. The Fourier transforms from both the firs and second- image subregions are normalized by the square roots of their respective magnitudes. This scheme yields optimal performance because the amounts of normalization applied to the spatial-frequency contents of the input and filter scenes are just enough to enhance their high-spatial-frequency contents while reducing their spurious low-spatial-frequency content. As a result, in SPOF PIV processing, particle-displacement correlation peaks can readily be detected above spurious background peaks, without need for masking or background subtraction.

Wemet, Mark P.↗