Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Real-Time Interactive 4D-STEM Phase-Contrast Imaging From Electron Event Representation Data: Less computation with the right representation

The arrival of direct electron detectors (DED) with high frame-rates in the field of scanning transmission electron microscopy has enabled many experimental techniques that require collection of a full diffraction pattern at each scan position, a field which is subsumed under the name four dimensional-scanning transmission electron microscopy (4D-STEM). DED frame rates approaching 100 kHz require data transmission rates and data storage capabilities that exceed commonly available computing infrastructure. Current commercial DEDs allow the user to make compromises in pixel bit depth, detector binning or windowing to reduce the per-frame file size and allow higher frame rates. This change in detector specifications requires decisions to be made before data acquisition that may reduce or lose information that could have been advantageous during data analysis. The 4D Camera, a DED with 87 kHz frame-rate developed at Lawrence Berkeley National Laboratory, reduces the raw data to a linear-index encoded electron event representation (EER). Here we show with experimental data from the 4D Camera that linear-index encoded EER and its direct use in 4D-STEM phase contrast imaging methods enables real-time, interactive phase-contrast from large-area 4D-STEM datasets. Furthermore, we detail the computational complexity advantages of the EER and the necessary computational steps to achieve real-time interactive ptychography and center-of-mass differential phase contrast using commonly available hardware accelerators.

4D-STEM↗

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Pockels cell enabled heterodyne phase contrast imaging diagnostic for detection of ion cyclotron emission

This work describes a novel optical heterodyne detection scheme that significantly extends the frequency response of the phase contrast imaging method to detect electron density fluctuations in tens of megahertz frequency range. The system employs a variable frequency electro-optic modulator to allow operation at any frequency in the range 10–40 MHz without the need to realign the system. The frequency coverage of the system makes it suitable to measure the radial structure of the electron density component of ion cyclotron emission on devices having confining magnetic field of a few tesla, thus extending the purely temporal measurements provided so far by magnetic probes.

47 OTHER INSTRUMENTATION↗

Investigation of near-field jet stability of a single-hole injector based on fast X-ray phase contrast imaging and image feature matching

Fuel spray is very effective in controlling the combustion process to improve engine performance and reduce emissions. Understanding the spray unstability during the injection process is of importance to improve the control of spray characteristics and engine operation. In this study, near-field biodiesel jets were recorded using fast X-ray phase contrast imaging and the flow features inside the jet were extracted using Speeded Up Robust Features (SURF) method. Here, the image similarity by feature matching was successfully used to represent the near-field jet stability. Based on the jet stability, an injection process can be divided into five stages: an unstable stage at needle opening, a partially stable transition stage at needle opening, a stable stage, a stable transition stage at needle closing and an unstable stage at needle closing. The ranges of needle lift for five stages were also determined. The jet unstability is highly related to the cavitation formation and gas purging process during needle opening. The variation of stable jet feature is dependent on the needle lift at needle closing. Higher needle lift for the similar jet feature at needle opening indicates a hydraulic delay compared to needle closing. Finally, the possible reasons of jet feature formation and feature detection used on the multi-hole injector are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Analyzer-based X-ray phase contrast imaging using the forward-diffracted o-beam in a few-millimetre-thick Bragg-case asymmetrically cut crystal

An analyzer-based X-ray phase contrast imaging experiment employing the forward-diffracted o-beam in a few-millimetre-thick Bragg-case asymmetrically cut analyzer crystal has been implemented and tested in a geometry similar to that used in conventional radiography. The high angular stability requirements were overcome using specially designed crystals and a closed-loop feedback intensity system, monitoring the intensity of the diffracted h-beam. Analyzer-based images (ABis) taken at different angular positions on the forward-diffracted o-beam rocking curve show different contrasts, as expected. However, the ABis did not show sharp borders. This was closely investigated by X-ray topography and Δ d / d mapping and was attributed to the stresses caused by the analyzer crystal's own weight in the bulk. Further investigation of the crystal design using finite element analysis coupled with dynamical theory of X-ray diffraction is envisaged.

Honnicke, Marcelo Goncalves (ORCID:000000033276432↗

Multiscale dynamic experiments on fiber-reinforced composites with damage assessment using high-speed synchrotron X-ray phase-contrast imaging

We report fiber-reinforced composites (FRCs) have been widely used as protection materials to replace heavier metals. However, predictive capabilities for the impact-induced failure of FRCs have not been well-developed. In this work, we introduced an integrated technique to visualize the dynamic failure of FRCs, with the modified Kolsky bar loading and the high-speed synchrotron X-ray phase-contrast imaging (PCI). We summarize our experimental studies across the FRCs’ structural levels by using this integrated technique, including single-fiber tensile experiments, fiber/matrix debonding experiments, and single-edge notched bending experiments on composite laminates. It is revealed that the high-speed synchrotron X-ray PCI technique possesses sufficient spatial resolution to identify the failure behavior of a single fiber in the 10-μm scale level, as well as temporal resolution to identify the time sequence of internal dynamic damage evolution. The technique can penetrate through the opaque composite sample and provide real-time visualization of small-scale damaging mechanisms such as the embedded fiber’s sliding in the matrix and the fiber’s transverse debonding with the matrix. At an expanding scale, the technique can identify the crack initiation and track the cracking behavior inside a single ply or between different plies of a composite laminate. High-speed visualization inside the material by this integrated technique provides critical deformation and failure information to develop physical understanding of the damage inside composites under impact.

47 OTHER INSTRUMENTATION↗

High-speed synchrotron X-ray phase-contrast imaging for evaluating microscale damage mechanisms and tracking cracking behaviors inside cross-ply GFRCs

In this study, we integrated the high-speed synchrotron X-ray phase-contrast imaging (PCI) with a modified Kolsky compression bar loading platform to visualize the dynamic failure processes of cross-ply glass fiber reinforced composites (GFRCs). Four S-2 glass/SC-15 composite specimens were prepared, having similar thicknesses but different stacking sequences, namely as [0 12 /90 12 ], [90 12 /0 12 ], [0 8 /90 8 /0 8 ], and [90 8 /0 8 /90 8 ]. Three-dimensional synchrotron X-ray computed tomography and scanning electron microscopy (SEM) were employed to examine the microstructures and quantify the fiber volume fractions. Each specimen was notched and subjected to a dynamic three-point flexural loading. The onset of cracking close to the notch tip, crack propagation in 0° or 90° plies and their interface, crack opening, and ultimately failure of the specimen were captured by high-speed synchrotron X-ray PCI. Additional dynamic experiments were performed to determine the average time when the stress wave propagated through the specimen and correlate the X-ray images with the specimen's force-deflection response. Finally, the surface morphology of each specimen after the dynamic loading was imaged by SEM. Comparison between real-time X-ray images and post-fracture SEM images demonstrated the capability of the X-ray method to record damage evolution inside composites. Furthermore, the high spatial and temporal resolutions of the X-ray setup and edge enhancement by PCI enabled the identification of microscale damage features within 1 μs. Two damaging processes were identified, crack growth was quantified, and fracture toughness of the composites was evaluated. The method is deemed useful to reveal microscale damage mechanisms and track cracking behaviors inside cross-ply GFRCs under dynamic loading in real time.

42 ENGINEERING↗

Equation-of-state measured via x-ray phase contrast imaging for Epon 828/DEA epoxy

Epoxies are a broad class of polymer materials often used as adhesive, structural or binding materials. Epon 828 is an epoxy resin that can be polymerized with a variety of curing agents with the choice of curing agent potentially having an effect on the resulting epoxy polymer’s material properties. In this study, the dynamic behavior of Epon 828 epoxy resin cured with diethanolamine (DEA) is investigated through a series of tamped Richtmyer-Meshkov instability (RMI) experiments measured with x-ray phase-contrast imaging. The measured shock and particle velocities are combined with data in the literature to calibrate Mie-Grüneisen equations-of-state (EOS) for portions and combinations of the collective dataset. The calibrated Mie-Grüneisen EOS are validated against particle velocity profiles extracted from published literature using the Eulerian hydrocode CTH. Here, the Mie-Grüneisen EOS fit to only the tamped RMI experimental data presented here most closely follows the particle velocity profile in the published literature.

36 MATERIALS SCIENCE↗

High-speed x-ray phase contrast imaging and digital image correlation analysis of microscale shock response of an additively manufactured energetic material simulant

The performance of energetic materials subjected to dynamic loading significantly depends on their micro- and meso-scale structural morphology. The geometric versatility offered by additive manufacturing opens new pathways to tailor the performance of these materials. Additively manufactured energetic materials (AMEMs) have a wide range of structural characteristics with a hierarchy of length scales and process-inherent heterogeneities, which are hitherto difficult to precisely control. It is important to understand how these features affect AMEMs’ response under dynamic/shock loading. Therefore, temporally and spatially resolved measurements of both macroscopic behavior and micro- and meso-level processes influencing macroscopic behavior are required. In this paper, we analyze the shock compression response of an AMEM simulant loaded under several impact conditions and orientations. Furthermore, x-ray phase contrast imaging (PCI) is used to track features across the observed shock front and determine the linear shock velocity vs particle velocity equation of state, as well as to quantify the interior deformation fields via digital image correlation (DIC) analyses. Photon Doppler velocimetry is simultaneously used to measure the particle velocities of the specimens, which are consistent with those obtained from x-ray PCI. The DIC analyses provide an assessment of the average strain fields inside the material, showing that the average axial strain depends on the loading intensity and reaches as high as 0.23 for impact velocities up to 1.5 km/s. The overall results demonstrate the utility of x-ray PCI for probing “in-material” equation of state and interior strains associated with dynamic shock compression behavior of the AMEM simulant.

3D printing↗

Phase contrast imaging measurements and numerical simulations of turbulent density fluctuations in gas-fuelled ECRH discharges in Wendelstein 7-X

The fundamental nature of turbulent density fluctuations in standard Wendelstein 7-X (W7-X) stellarator discharges is investigated experimentally via phase contrast imaging (PCI) in combination with gyrokinetic simulations with the code GENE. We find that density fluctuations are ion-temperature-gradient-driven and radially localised in the outer half of the plasma. It is shown that the line-integrated PCI measurements cover the right range of wavenumbers and a favourable toroidal and poloidal location to capture some of the strongest density fluctuations in W7-X. Due to the radial localisation of fluctuations, measured wavenumber–frequency spectra exhibit a dominant phase velocity, which can be related to the E × B rotation velocity at the radial position of a well in the neoclassical radial electric field. The match is robust against variations of heating power and line-integrated density, which is partly due to the localisation of fluctuations and partly due to effects of the radial gradient in the E × B velocity profile on the wavenumber–frequency spectrum. The latter effect is studied with a newly built synthetic PCI diagnostic and global gyrokinetic simulations with GENE-3D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transient Deformation in Additively Manufactured 316L Stainless Steel Lattices Characterized with in-situ X-ray Phase Contrast Imaging: The Complete Dataset for Three Geometrical Lattices

Metallic lattice structures are being considered for shock mitigation applications due to their superior mechanical properties, energy absorption capability and lightweight characteristics inherent of the additive manufacturing process. In this study, shock compression experiments coupled to x-ray phase contrast imaging (PCI) were conducted on 316L stainless steel lattices. Meso-scale simulations incorporating the as-built lattice structure characterized by computed tomography were used to simulate PCI radiographs in CTH for direct comparison to experimental data. The methodology presented here offers robust validation for constitutive properties to further our understanding of lattice compaction at application-relevant strain rates.

36 MATERIALS SCIENCE↗

Quantitative x ray phase contrast imaging of oblique shock wave–interface interactions

Oblique shock wave–interface interactions of gases and liquids have been extensively studied in shock tubes using optical methods to measure equation-of-state (EOS) parameters. However, this is difficult with solids due to their opaqueness to visible light. X ray phase contrast imaging (XPCI) has the penetrative strength to probe solids while still being sensitive to mass density and enhancing the visibility of material boundaries. We investigate the accuracy and repeatability of measuring the mean value of the average mass density (areal density divided by thickness) over region S (B S ) and flow deflection angle (θ) from XPCI images of a sample. To that end, a Hough transform-based method for measuring θ is developed. To measure B S , the XPCI image intensity probability density function (PDF) is modeled accounting for the spatial distribution of x ray energy, scintillator response, and pulse-to-pulse variation in the x ray intensity. In addition, a Monte Carlo-based algorithm for computing the B S PDF is developed. Both methods are validated on an impact-generated oblique shock wave interacting at a solid polymer-to-polymer interface. Furthermore this is accomplished through a comparison to hydrodynamic simulations using well-established EOS. Under the modeling framework for the XPCI image intensity, B S is computed with an accuracy of < 0.1% and precision of 3%–5%, while θ has an uncertainty of 0.2°, respectively. This shows that the XPCI-based model that is developed here could be an invaluable tool for high-fidelity testing of hydrodynamic models in shock polar configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct observation on supersonic microprojectile penetration of carbon fiber composites with ultrafast synchrotron X-ray phase contrast imaging

High-speed penetration into carbon fiber composites is of fundamental importance to materials science and impact engineering, but research along this line suffers considerably from the lack of direct experimental observations. Here we investigate such penetration dynamics of a unidirectional carbon fiber reinforced epoxy (UCFRE) composite, with a combination of in situ, ultrafast, synchrotron phase contrast imaging and finite element (FE) analysis. The experiments yield the first direct observation on projectile trajectories and fiber-scale deformation and damage in the UCFRE composites during supersonic microprojectile penetration, for different fiber orientations (0 degrees - 90 degrees from the impact direction) and projectile velocities (600 - 850 m.s -1 ), at unprecedented temporal (~ 100 ps) and spatial (5 μm) resolutions. The maximum penetration depth decreases with increasing fiber orientation angles, as a result of anisotropic damage evolution in the composite sample. Strain localizations are prone to develop along a direction perpendicular to the fiber orientation, while the damage or cavity region, along the fiber direction. FE modeling with a three-dimensional Hashin criterion yields consistent projectile trajectory and cavity morphology with the experimental results. Finally, with increasing fiber orientation angles, damage analyses show a transition in the damage mode from fiber compression to matrix compression damage, in line with the increasing maximum penetration depth.

36 MATERIALS SCIENCE↗

X-Ray Radiography and Phase-Contrast Imaging of the Engine Combustion Network Spray B Sprays and Injection

X-ray measurements of diesel sprays from two of the Engine Combustion Network (ECN) Spray B injectors are described. Measurements in these three-hole nozzles complement both visible light measurements of these sprays and previous x-ray measurements of the axial single-hole ECN Spray A injectors. Both axial and lateral motions of the injector needle valve were measured with x-ray phase contrast imaging. Additionally, the liquid mass distribution in room temperature sprays at elevated ambient pressure was determined with x-ray radiography. Measurements of both needle valve motion and spray distribution were performed at both the standard Spray A/B conditions and with selected variations of injection pressure, ambient density, and injection timing. The needle valve motion for the Spray B injectors is quite similar to that of the Spray A injectors, though little lateral motion is seen in either Spray B injector. Compared to the sprays from the Spray A injectors, the sprays from Spray B penetrate more slowly in the near-nozzle region, demonstrate a broader, more uniform distribution in the transverse direction, and are significantly more variable with respect to time. These differences demonstrate the importance of studies with multi-hole nozzles to provide insight into applied diesel combustion.

42 ENGINEERING↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Phase Contrast Imaging of the Impact of Multiple HMX Particles in a Polymeric Matrix

The initiation of high explosives (HEs) under shock loading lacks a comprehensive understanding: particularly at the particle scale. One common explanation is the hot spot theory, which suggests that energy in the material resulting from the impact event is localized in a small area causing an increase in temperature that can lead to ignition. This study focuses on the response of HMX particles (a common HE) within a polymer matrix (Sylgard-184 (R)), a simplified example of a polymer-bound explosive (PBX). These PBXs consist of multiple HMX particles in a single polymer-bound sample. A light gas gun was used to load the samples at impact velocities above 400 m/s. The impact events were visualized using X-ray phase-contrast imaging (PCI) allowing real-time observation of the impact event. The experiment used two different types of samples (multi-particle and two crystals) and found evidence of cracking and debonding in both sample types. Additionally, it was found that the multiple particle samples showed similar evidence of damage at lower velocities than that of single particle samples. This is an expected result as the multiple particles add additional interfaces for stress concentration and frictional heating.

42 ENGINEERING↗

Single-shot in-line x-ray phase-contrast imaging of void-shockwave interactions in fusion energy materials

Recent breakthroughs in nuclear fusion, specifically the report of reactions exceeding scientific breakeven at the National Ignition Facility (NIF), highlight the potential of inertial fusion energy (IFE) as a sustainable and virtually limitless energy source. However, further progress in IFE requires characterization of defects in ablator materials and how they affect fuel capsule compression. Voids within the ablator can degrade energy yield, but their impact on the density distribution has primarily been studied through simulations, with limited high-resolution experimental validation. To address this, we used the x-ray free-electron laser (XFEL) at the matter in extreme conditions (MECs) instrument at the Linac coherent light source (LCLS) to capture 2D x-ray phase-contrast (XPC) images of a void-bearing sample with a composition similar to inertial confinement fusion (ICF) ablators. By driving a compressive shockwave through the sample using MEC's long-pulse laser system, we analyzed how voids influence shockwave propagation and density distribution during compression. To quantify this impact, we extracted phase information using two phase retrieval algorithms. First, we applied the contrast transfer function (CTF) method, paired with Tikhonov regularization and a fast optimization approach to generate an initial phase estimate. We then refined the result using a projected gradient descent (PGD) method that works directly with the sample's refractive index. Comparing these results with radiation adaptive grid Eulerian (xRAGE) radiation hydrodynamic simulations enables identification of model validation needs or improvements. By calculating phase maps in situ, it becomes possible to reconstruct areal density maps, improving understanding of laser-capsule interactions and advancing IFE research.

Hodge, D. S. [Colorado State Univ., Fort Collins, ↗

Spectral gratings-based phase-contrast imaging for materials characterization

Spectral X-ray detectors provide a direct observation of the energy spectrum of a transmitted X-ray beam, both for typical and phase-contrast gratings-based systems. The sensitivity of a gratings-based X-ray system to small-angle deflections from a given particle size is dependent on X-ray energy. Therefore, spectral (energy-sensitive) detectors could be sensitive to particle size, even with a broad spectrum from a commercial X-ray generator. Furthermore, these detectors allow direct observation of how the X-ray spectrum is changing as the beam is passing through an object and gratings, and how this affects grating visibilities used to determine the presence of small-angle deflections. This is a particular issue for higher-energy systems where artifacts from beam hardening are common. We present results exploring the particle-size dependent signatures that are available from a spectral gratings-based phase-contrast X-ray imaging system, and the feasibility of observing them with lab-based, broad-spectrum X-ray generators.

Gilbert, Andrew J.↗