Search NASASearch

SEARCH · Search NASA

Results for “Pioneer Space Probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

812 records · Page 2

Galileo Probe Battery System

The conclusions of the Galileo probe battery system are: the battery performance met mission requirements with margin; extensive ground-based and flight tests of batteries prior to probe separation from orbiter provided good prediction of actual entry performance at Jupiter; and the Li-SO2 battery was an important choice for the probe's main power.

Dagarin, B. P.

First N 2 Profile for Venus’ Deep Lower Atmosphere

We present the first N 2 profile for Venus’ deep lower atmosphere (<15 km) and a constrained isotopic composition for cloud N 2 [1]. This work directly addresses unresolved questions for Venus using legacy observations. Prior to this work, there were no reported measurements for N 2 abundances at <15 km and the isotopic composition remained unconstrained [2]. The N 2 parameters are critical to understanding the evolution and thermal properties of the atmosphere [3-7]. Our N 2 results were obtained by re-analysis of data acquired in 1978 by the Pioneer Venus Large Probe Neutral Mass Spectrometer (LNMS) [8]. The archived mass spectra from 64.2 to 0.2 km were treated using the analytical procedures specifically developed for the LNMS [9-11]. Judicious peak fitting permitted disambiguation of (A) N 2 + and CO + at 28 u and (B) 14 N 15 N+, 13 CO + , and C 2 H 5 + at 29 u. Quality controls included comparing the (A) LNMS CO + /CO 2 + ratios to the NIST database and literature and (B) fitted counts for CO + to the expected counts of CO + calculated from C 18 O + and 13 CO + using the LNMS 16 O/ 18 O and 12 C/ 13 C ratios (obtained from CO 2 ). Our results show that N 2 is uniformly mixed across the deep lower atmosphere between ~0.2 and 15 km (2.49 ± 0.10 v%). In contrast, N 2 is non-uniformly mixed across the sub-cloud atmosphere and clouds (~15–59 km), where N 2 abundances increase by ~ 2-fold between ~15 km (2.45 ± 0.32 v%) and ~59-51 km (5.21 ± 0.18 v%). Using the cloud data, we also obtained a constrained 15 N/ 14 N ratio (2.93×10 -3 ± 0.13×10 -3 ) and δ 15 N value (-204 ± 35‰). Thus, the LNMS results [1] suggest that (A) the atmosphere is unstable at <15 km, (B) N 2 is not well-mixed >15 km, and (C) the cloud δ 15 N falls between Earth and the solar wind [12, 13]. Comparisons of the N 2 abundances and isotopic compositions for nitrogen, carbon, and oxygen to other Venus measurements will be discussed.

deep lower atmosphere

Coding Performance of the Probe-Orbiter-Earth Communication Link

The coding performance of the Probe-Orbiter-Earth communication link is analyzed and compared for several cases. It is assumed that the coding system consists of a convolutional code at the Probe, a quantizer and another convolutional code at the Orbiter, and two cascaded Viterbi decoders or a combined decoder on the ground.

D Divsalar

Transit Thermal Control Design for Galileo Entry Probe for Planet Jupiter

A totally passive design was completed for the thermal control of the Galileo entry probe during its transit to the planet Jupiter. The design utilizes radio isotope heater units, multilayer insulation blankets and a thermal radiator in conjunction with a design conductance support structure to achieve both the required storage and critical initial planet atmosphere entry temperatures. The probe transit thermal design was completed and verified based on thermal vacuum testing of a prototype probe thermal test model.

George C. Haverly

Recommended Practice for Use of ExB Probes in Electric Propulsion Testing

An ExB probe is an electric propulsion plume diagnostic that has at its core a Wien filter. Ions entering the instrument experience perpendicular electric and magnetic fields and are filtered based on their velocity. While the ExB probe can be used to estimate the ion velocity distribution function, in the electric propulsion community, it is commonly used to measure species fractions. There are numerous probe designs, implementation and operation procedures, and data analysis approaches described and in use across the community. This paper provides recommendations and descriptions of best practices for design, implementation, and data analysis for the ExB probe, with a particular emphasis on Hall and ion thrusters. This work contributes to the broader community goal to standardize the use of diagnostics in electric propulsion testing.

ExB probe

Probing and Tuning Spatiotemporal pH Evolution in Aqueous Zinc Ion Batteries

Aqueous zinc-ion batteries (AZIBs) offer a combination of safety and low cost, but they suffer from dynamic pH fluctuations that drive parasitic reactions and capacity fading. In this review, we report the current mechanistic understanding of the dynamic pH evolution across the electrolyte-electrode interface and its role in triggering interphase instability. We summarize advanced strategies to regulate pH, including electrolyte engineering, electrode surface modification, and interphase construction. We further discuss current methods for probing pH dynamics and outline potential future approaches for gaining deeper mechanistic and design insights.

Zheng, Xueli [SLAC]

Performance Results of a Digital Test Signal Generator

Performance results of a digital test signal-generator hardware-demonstration unit are reported. Capabilities available include baseband and intermediate frequency (IF) spectrum generation, for which test results are provided. Repeatability in the setting of a given signal-to-noise ratio (SNR) when a baseband or an IF spectrum is being generated ranges from 0.01 dB at high SNR's or high data rates to 0.3 dB at low data rates or low SNR's. Baseband symbol SNR and carrier SNR (P c /N o ) accuracies of 0.1 dB were verified with the built-in statistics circuitry. At low SNR's that accuracy remains to be fully verified. These results were confirmed with measurements from a demodulator synchronizer assembly for the baseband spectrum generation, and with a digital receiver (Pioneer 10 receiver) for the IF spectrum generation.

B O Gutierrez-Luaces

Probing the fatigue enhancement in a thermally aged cast duplex stainless steel by in situ neutron diffraction

After long-term thermal aging at 400 °C for 3000 h and 10,000 h, a cast duplex stainless steel exhibits promoted fatigue performance, including enhanced three-stage cyclic hardening and prolonged fatigue life. Utilizing in situ neutron diffraction, the phase-specific stresses are resolved, and their evolutions over entire fatigue cycling reveal the underlying mechanisms of the fatigue enhancement. It is found that the ferrite phase bears a much higher stress than the austenite matrix under both as-received and aged conditions. The enhanced cyclic hardening in Stage I is attributed to the strengthening of both phases due to thermal aging, while the enhancement in Stage III results from the martensitic transformation induced strengthening. The fatigue life is prolonged thanks to the cyclic hardening and the delay of martensitic transformation in the austenite phase after thermal aging.

Yu, Dunji [ORNL] (ORCID:0000000189467851)

Methodology of Atomic Force Microscopy Visualization of Electrode–Electrolyte Interfaces

Electrochemical atomic force microscopy (EC-AFM) provides unprecedented insights into the microstructure of electrode–electrolyte interfaces during electrochemical reactions. However, performing EC-AFM measurements has many challenges, for example, drift, contamination, and probe degradation. We present solutions to these experimental issues through electrochemical cell design and carefully chosen experimental parameters. The possibility that the probes can react with the interface during scanning, generating false-positive electrochemical dynamics, is discussed as an example of the challenge of high-fidelity EC-AFM measurement. Here, we demonstrate this effect in highly ordered pyrolytic graphite and show that we could use electrochemical control of the AFM probe to enable high-fidelity in situ AFM visualization of solid–liquid interfaces during electrochemical reactions.

Electrochemical cells

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U

Multi-modal dynamic radiography using short-pulse laser-generated probe beams

Radiography is an important tool for the interrogation of dynamic experiments in the fields of dynamic properties of materials, and in condensed matter, high explosive, and high-energy-density physics. Multi-modal radiography advances the hypothesis that combining the information delivered by multiple radiographic modalities can lead to more constrained (improved) “reconstruction” of the scene than can be obtained from a single probe. We identify four modalities: multi-probe, time sequence, multi-view, and multi-messenger. Multi-probe radiography is a promising candidate for a next-generation dynamic radiographic facility. High-energy X-rays are the most frequently used probe for dynamic radiography, although recent developments show the utility of proton (pRad), electron (eRad), and neutron probe beams. Because each probing species interacts with material in the radiographic scene through quantitatively different mechanisms, each returns independent information about the scene, which can add extra constraints to the reconstruction process. How to conduct detailed, quantitative “co-analysis” of multiple data streams remains an area of active research. Multi-beam, short-pulse, laser-generated probes offer sufficient dose, an appropriate spectrum, and appropriate spatio-temporal resolution to produce high-quality dynamic radiographs. This paper reports on technology development to advance the state of the art of multi-modal/multi-probe radiography and the pursuit of both deterministic and inferential (AI/ML assisted) co-analysis methodologies to produce more constrained reconstructions from multi-modal data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Probing room temperature indirect and minimum direct band gaps of h-BN

Abstract Hexagonal boron nitride (h-BN) has attracted considerable interest as an ultrawide bandgap (UWBG) semiconductor. Experimental studies focused on the detailed near band-edge structure of h-BN at room temperature are still lacking. We report a direct experimental measurement of the near band-edge structure performed on h-BN quasi-bulk wafers via photocurrent excitation spectroscopy (PES). PES resolved the band-to-band transitions near M- and K-points in the Brillion zone (BZ), from which the room temperature indirect band gap of E g M K ∼6.02 eV, minimum direct bandgap at M-point of E g M = 6.36 eV and next lowest direct energy bandgap at K-point of E g K = 6.56 eV , have been simultaneously determined for the first time experimentally. The measured energy differences between K- and M-points in the conduction band minimum (CBM) and valence band maximum (VBM) are Δ E C M K = 0.54 eV and Δ E V M K = 0.34 eV, respectively, in good agreement with the calculation results. Significantly differing from its III-nitride wurtzite counterparts, in which only electrons and holes in the conduction and valence band extremes at the Γ-point are predominantly involved in the optical and transport processes, the results highlighted that charge carriers associated with both M- and K-valleys control to the optical excitation, recombination and charge transport processes in h-BN.

Physics

The Cassini/Huygens Doppler Wind Experiment: Results from the Titan Descent

The primary objective of the Doppler Wind Experiment (DWE), one of the six scientific investigations comprising the payload of the ESA Huygens Probe, is a determination of the wind velocity in Titan's atmosphere. Measurements of the Doppler shift of the S-band (2040 MHz) carrier signal to the Cassini Orbiter and to Earth were recorded during the Probe descent in order to deduce wind-induced motion of the Probe to an accuracy better than 1 m s-1. An experiment with the same scientific goal was performed with the Galileo Probe at Jupiter. Analogous to the Galileo experience, it was anticipated that the frequency of the Huygens radio signal could be measured on Earth to obtain an additional component of the horizontal winds. Specific secondary science objectives of DWE include measurements of: (a) Doppler fluctuations to determine the turbulence spectrum and possible wave activity in the Titan atmosphere; (b) Doppler and signal level modulation to monitor Probe descent dynamics (e.g., spinrate/spinphase, parachute swing); (c) Probe coordinates and orientation during descent and after impact on Titan.

M K Bird

Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst

Probing Operando Electrochemical Strain Generation in α-NaFeO 2 Composite Cathodes during Cycling of Na-Ion Batteries

The transition metal oxide (TMO) cathodes in Na-ion batteries suffer from low-capacity retention. Chemo-mechanical instabilities lead to the deterioration of the electrochemical performance of TMO cathodes in Li-ion batteries. However, there is not much known about the chemo-mechanical instabilities in the TMO cathodes for Na-ion batteries. Understanding the governing forces behind the interplay between the electrochemical performance and mechanical stability in TMO cathodes is critical for the development of Na-ion batteries. Here, we synchronize the digital image correlation (DIC) technique with electrochemical analysis to capture the real-time deformation behavior of the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage is 3.6 V, the cathode experiences reversible deformations (except for the first cycle). There is negative strain (shrinkage) generation during Na extraction and positive strain (expansion) generation during the subsequent Na insertion. A detailed analysis of the potential-dependent strain rate evolution points out complicated phase transformations and nonequilibrium conditions in the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage was increased to 4.2 V, there was a rapid capacity loss and large plastic deformations in the α-NaFeO 2 cathodes. We provide an in-depth discussion about the possible mechanisms behind the chemo-mechanical instabilities in the α-NaFeO 2 . In conclusion, the correlation is critical to develop material-based strategies to mitigate instability mechanisms in TMO cathodes for Na-ion batteries.

Wable, Minal [University of Maryland Baltimore Cou