Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pixel array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Design and engineering challenges of a multi-energy hard x-ray camera for long-pulse profile measurements at WEST tokamak

The WEST tokamak has recently been prepared for long pulse operation with a water-cooled full first wall. Heating is provided by radiofrequency systems, including Lower Hybrid Current Drive (LHCD). The Princeton Plasma Physics Laboratory has developed a multi-energy hard x-ray camera for profile measurements at WEST. The camera is based on a new generation of 2D pixel array detectors that allow the energy threshold to be independently set for each pixel. The diagnostic will provide spatial, temporal and energy resolved measurements of the hard x-ray emission from the full plasma cross-section, investigating several physical quantities such as the electron temperature from continuum emission, the fast electron tail density produced by radiofrequency current drive and runaway electrons, as well as characteristic tungsten x-rays due to beam-target emission at the edge. Overall, this work describes the engineering challenges that the WEST long pulse scenario poses for this diagnostic and how the design addresses and solves them. Vacuum, thermal stress and heat transfer calculations are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a 2-mm thick, 16x16 Cadmium-Zinc-Telluride Pixel Array

The detector under study is a 2-mm-thick, 16x16 Cadmium-Zinc-Telluride pixel array with a pixel pitch of 300 microns and inter-pixel gap of 50 microns. This detector is a precursor to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation. In addition, we discuss electric field modeling for this specific detector geometry and the role this mapping will play in terms of charge sharing and charge loss in the detector.

Gaskin, Jessica↗

Linear fitting of multi-threshold counting data

The present disclosure provides a system and method for efficiently mining multi-threshold measurements acquired using photon counting pixel-array detectors for spectral imaging and diffraction analyses. Images of X-ray intensity as a function of X-ray energy were recorded on a 6 megapixel X-ray photon counting array detector through linear fitting of the measured counts recorded as a function of counting threshold. An analytical model is disclosed for describing the probability density of detected voltage, utilizing fractional photon counting to account for edge/corner effects from voltage plumes that spread across multiple pixels. Three-parameter fits to the model were independently performed for each pixel in the array for X-ray scattering images acquired for 13.5 keV and 15.0 keV X-ray energies. From the established pixel responses, multi-threshold composite images produced from the sum of 13.5 keV and 15.0 keV data can be analytically separated to recover the monochromatic images through simple linear fitting.

47 OTHER INSTRUMENTATION↗

Quantifying Dynamic Signal Spread in Real-Time High-Energy X-ray Diffraction

Abstract Measured intensity in high-energy monochromatic X-ray diffraction (HEXD) experiments provides information regarding the microstructure of the crystalline material under study. The location of intensity on an areal detector is determined by the lattice spacing and orientation of crystals so that changes in the heterogeneity of these quantities are reflected in the spreading of diffraction peaks over time. High temporal resolution of such dynamics can now be experimentally observed using technologies such as the mixed-mode pixel array detector (MM-PAD) which facilitates in situ dynamic HEXD experiments to study plasticity and its underlying mechanisms. In this paper, we define and demonstrate a feature computed directly from such diffraction time series data quantifying signal spread in a manner that is correlated with plastic deformation of the sample. A distinguishing characteristic of the analysis is the capability to describe the evolution from the distinct diffraction peaks of an undeformed alloy sample through to the non-uniform Debye–Scherrer rings developed upon significant plastic deformation. We build on our previous work modeling data using an overcomplete dictionary by treating temporal measurements jointly to improve signal spread recovery. We demonstrate our approach in simulations and on experimental HEXD measurements captured using the MM-PAD. Our method for characterizing the temporal evolution of signal spread is shown to provide an informative means of data analysis that adds to the capabilities of existing methods. Our work draws on ideas from convolutional sparse coding and requires solving a coupled convex optimization problem based on the alternating direction method of multipliers.

Engineering↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Grains and Strains from Cepstral Analysis of 4D-STEM Nano-Diffraction Datasets

We report the availability of fast, high dynamic range pixel array detectors makes scanning convergent beam electron diffraction (CBED) a powerful tool for rapid, spatially resolved characterization of lattice structure over a wide range of length scales. However, to extract useful structural information from the large 4-dimensional datasets, especially for complex, 3D specimens, we must confront challenges with CBED intensity variations due to crystal mistilts and multiple scattering as well as challenges with precisely localizing diffracted disk centers.

36 MATERIALS SCIENCE↗

Mechanistic Insights into Superlattice Transformation at a Single Nanocrystal Level Using Nanobeam Electron Diffraction

Understanding the mechanism and ultimately directing nanocrystal (NC) superlattice assembly and attachment have important implications on future advances in this emerging field. Here, we use 4D-STEM to investigate a monolayer of PbS NCs at various stages of the transformation from a hexatic assembly to a nonconnected square-like superlattice over large fields of view. Maps of nanobeam electron diffraction patterns acquired with an electron microscope pixel array detector (EMPAD) offer unprecedented detail into the 3D crystallographic alignment of the polyhedral NCs. Our analysis reveals that superlattice transformation is dominated by translation of prealigned NCs strongly coupled along the <11n>AL direction and occurs stochastically and gradually throughout single grains. We validate the generality of the proposed mechanism by examining the structure of analogous PbSe NC assemblies using conventional transmission electron microscopy and selected area electron diffraction. Here, the experimental results presented here provide new mechanistic insights into NC self-assembly and oriented attachment.

36 MATERIALS SCIENCE↗

Measuring femtometer lattice displacements driven by free carrier diffusion in a polycrystalline semiconductor using time-resolved x-ray scattering

We show that time-resolved x-ray scattering can be applied to polycrystalline materials for the measurement of carrier diffusion. A polycrystalline indium antimonide sample is prepared by high-intensity ultrafast laser surface melting and re-solidification under vacuum to create randomly oriented grains with an average size of 13 nm. Two static diffraction rings are simultaneously observed on a gated pixel array detector. Their centroids move following lower-intensity laser excitation, and utilizing an in-situ angular calibration, the transient lattice spacing is determined with femtometer accuracy, thereby allowing the measurement of charge carrier dynamics. Compared to bulk calculations, we find that carrier diffusion slows by more than one order of magnitude. This result provides evidence for the formation of potential energy barriers at the grain boundaries and demonstrates the capability of time-resolved x-ray scattering to probe nanoscale charge transport in materials other than near-perfect crystals.

36 MATERIALS SCIENCE↗

Intermittent plasticity in individual grains: A study using high energy x-ray diffraction

Abstract Long-standing evidence suggests that plasticity in metals may proceed in an intermittent fashion. While the documentation of intermittency in plastically deforming materials has been achieved in several experimental settings, efforts to draw connections from dislocation motion and structure development to stress relaxation have been limited, especially in the bulk of deforming polycrystals. This work uses high energy x-ray diffraction measurements to build these links by characterizing plastic deformation events inside individual deforming grains in both the titanium alloy, Ti-7Al, and the magnesium alloy, AZ31. This analysis is performed by combining macroscopic stress relaxation data, complete grain stress states found using far-field high energy diffraction microscopy, and rapid x-ray diffraction spot measurements made using a Mixed-Mode Pixel Array Detector. Changes in the dislocation content within the deforming grains are monitored using the evolution of the full 3-D shapes of the diffraction spot intensity distributions in reciprocal space. The results for the Ti-7Al alloy show the presence of large stress fluctuations in contrast to AZ31, which shows a lesser degree of intermittent plastic flow.

36 MATERIALS SCIENCE↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗

Focusing a round coherent beam by spatial filtering the horizontal source

This paper illustrates the use of spatial filtering with a horizontal slit near the source to enlarge the horizontal coherence in an experimental station and produce a diffraction-limited round focus at an insertion device beamline for X-ray photon correlation spectroscopy experiments. Simple expressions are provided to guide the optical layout, and wave propagation simulations confirm their applicability. The two-dimensional focusing performance of Be compound refractive lenses to produce a round diffraction-limited focus at 11 keV capable of generating a high-contrast speckle pattern of an aerogel sample is demonstrated. The coherent scattering patterns have comparable speckle sizes in both horizontal and vertical directions. The focal spot sizes are consistent with hybrid ray-tracing calculations. Producing a two-dimensional focus on the sample can be helpful to resolve speckle patterns with modern pixel array detectors with high visibility. This scheme has now been in use since 2019 for the 8-ID beamline at the Advanced Photon Source, sharing the undulator beam with two separate beamlines, 8-ID-E and 8-ID-I at 7.35 keV, with increased partially coherent flux, reduced horizontal spot sizes on samples, and good speckle contrast.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of fast and efficient lossless compression algorithms for macromolecular crystallography experiments

Structural biology experiments benefit significantly from state-of-the-art synchrotron data collection. One can acquire macromolecular crystallography (MX) diffraction data on large-area photon-counting pixel-array detectors at framing rates exceeding 1000 frames per second, using 200 Gbps network connectivity, or higher when available. In extreme cases this represents a raw data throughput of about 25 GB s −1 , which is nearly impossible to deliver at reasonable cost without compression. Our field has used lossless compression for decades to make such data collection manageable. Many MX beamlines are now fitted with DECTRIS Eiger detectors, all of which are delivered with optimized compression algorithms by default, and they perform well with current framing rates and typical diffraction data. However, better lossless compression algorithms have been developed and are now available to the research community. Here one of the latest and most promising lossless compression algorithms is investigated on a variety of diffraction data like those routinely acquired at state-of-the-art MX beamlines.

36 MATERIALS SCIENCE↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

Method for producing a hybridization of detector array and integrated circuit for readout

A process is explained for fabricating a detector array in a layer of semiconductor material on one substrate and an integrated readout circuit in a layer of semiconductor material on a separate substrate in order to select semiconductor material for optimum performance of each structure, such as GaAs for the detector array and Si for the integrated readout circuit. The detector array layer is lifted off its substrate, laminated on the metallized surface on the integrated surface, etched with reticulating channels to the surface of the integrated circuit, and provided with interconnections between the detector array pixels and the integrated readout circuit through the channels. The adhesive material for the lamination is selected to be chemically stable to provide electrical and thermal insulation and to provide stress release between the two structures fabricated in semiconductor materials that may have different coefficients of thermal expansion.

Fossum, Eric R.↗