Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polarimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Polarimeter + Lidar–Derived Aerosol Particle Number Concentration

In this study, we propose a simple method to derive vertically resolved aerosol particle number concentration (Na) using combined polarimetric and lidar remote sensing observations. This method relies on accurate polarimeter retrievals of the fine-mode column-averaged aerosol particle extinction cross section and accurate lidar measurements of vertically resolved aerosol particle extinction coefficient such as those provided by multiwavelength high spectral resolution lidar. We compare the resulting lidar + polarimeter vertically resolved N(a) product to in situ N(a) data collected by airborne instruments during the NASA aerosol cloud meteorology interactions over the western Atlantic experiment (ACTIVATE). Based on all 35 joint ACTIVATE flights in 2020, we find a total of 32 collocated in situ and remote sensing profiles that occur on 11separate days, which contain a total of 322 cloud-free vertically resolved altitude bins of 150 m resolution. We demonstrate that the lidar + polarimeter N(a) agrees to within 106% for 90% of the 322 vertically resolved points. We also demonstrate similar agreement to within 121% for the polarimeter-derived column-averaged N(a). We find that the range-normalized mean absolute deviation (NMAD) for the polarimeter-derived column-averaged Na is 21%, and the NMAD for the lidar + polarimeter-derived vertically resolved Na is 16%. Taken together, these findings suggest that the error in the polarimeter-only column-averaged N(a) and the lidar + polarimeter vertically resolved N(a) are of similar magnitude and represent a significant improvement upon current remote sensing estimates of N(a).

RSP↗

Optimization of system parameters for a complete multispectral polarimeter

We optimize a general class of complete multispectral polarimeters with respect to signal-to-noise ratio, stability against alignment errors, and the minimization of errors regarding a given set of polarization states. The class of polarimeters that are dealt with consists of at least four polarization optics each with a multispectral detector. A polarization optic is made of an azimuthal oriented wave plate and a polarizing filter. A general, but not unique, analytic solution that minimizes signal-to-noise ratio is introduced for a polarimeter that incorporates four simultaneous measurements with four independent optics. The optics consist of four sufficient wave plates, where at least one is a quarter-wave plate. The solution is stable with respect to the retardance of the quarter-wave plate; therefore, it can be applied to real-world cases where the retardance deviates from {lambda}/4. The solution is a set of seven rotational parameters that depends on the given retardances of the wave plates. It can be applied to a broad range of real world cases. A numerical method for the optimization of arbitrary polarimeters of the type discussed is also presented and applied for two cases. First, the class of polarimeters that were analytically dealt with are further optimized with respect to stability and error performance with respect to linear polarized states. Then a multispectral case for a polarimeter that consists of four optics with real achromatic wave plates is presented. This case was used as the theoretical background for the development of the Airborne Multi-Spectral Sunphoto- and Polarimeter (AMSSP), which is an instrument for the German research aircraft HALO.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty

The Q-weak experiment aims to measure the weak charge of proton with a precision of 4.2%. The proposed precision on weak charge required a 2.5% measurement of the parity violating asymmetry in elastic electron - proton scattering. Polarimetry was the largest experimental contribution to this uncertainty and a new Compton polarimeter was installed in Hall C at Jefferson Lab to make the goal achievable. In this polarimeter the electron beam collides with green laser light in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in lead tungstate crystals. This diamond micro-strip detector is the first such device to be used as a tracking detector in a nuclear and particle physics experiment. The diamond detectors are read out using custom built electronic modules that include a preamplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use field programmable gate array based general purpose logic modules for event selection and histogramming. Extensive Monte Carlo simulations and data acquisition simulations were performed to estimate the systematic uncertainties. Additionally, the Moller and Compton polarimeters were cross calibrated at low electron beam currents using a series of interleaved measurements. In this dissertation, we describe all the subsystems of the Compton polarimeter with emphasis on the electron detector. We focus on the FPGA based data acquisition system built by the author and the data analysis methods implemented by the author. The simulations of the data acquisition and the polarimeter that helped rigorously establish the systematic uncertainties of the polarimeter are also elaborated, resulting in the first sub 1% measurement of low energy (?1 GeV) electron beam polarization with a Compton electron detector. We have demonstrated that diamond based micro-strip detectors can be used for tracking in a high radiation environment and it has enabled us to achieve the desired precision in the measurement of the electron beam polarization which in turn has allowed the most precise determination of the weak charge of the proton.

43 PARTICLE ACCELERATORS↗

An absolute recoil-carbon polarimeter for polarized light-ions at the BNL Booster

We describe a recoil-carbon polarimeter for the BNL Booster synchrotron capable of measuring the transverse polarization of both the polarized proton beam and the polarized 3 He ion beam throughout the acceleration cycle. The instrument addresses a critical gap in the BNL polarized beam program: no independent polarization measurement currently exists in the injector chain between the 200 MeV Linac polarimeter and the AGS. The proposed new polarimeter will provide continuous, absolute polarization measurements at the Booster stage, supplying additional anchor points for the polarization transmission through the accelerator chain. The polarimeter 9 is based on elastic pC and 3 He C scattering from a thin internal carbon target, with detection of the recoil 12 C nucleus in a fixed six-station silicon detector ring. A single detector geometry provides continuous kinematic coverage from injection to extraction for both beam species without mechanical adjustment. For pC scattering, the available data and the Bonin parametrization provide a well-established basis for estimating the analyzing power and figure of merit over the Booster energy range; for 3 He C the sole experimental anchor is a measurement at 443 MeV, and the Booster polarimeter itself is identified as the instrument to map the analyzing power across the remainder of the acceleration ramp by a ramp-and-return calibration that anchors the absolute 3 He polarization scale to a few percent. Provision for future deuteron polarimetry is incorporated in the chamber design without modification to the existing geometry. With appropriate detector upgrades, the same recoil-carbon technique can be extended to deuteron beams, for which analyzing power data are already available, and, with future analyzing-power measurements, also to 6 Li and 7 Li beams, making the polarimeter a versatile instrument for the full range of light polarized ion species anticipated at BNL.

43 PARTICLE ACCELERATORS↗

Optical Alignment of the High-Precision UV Spectro-Polarimeter (CLASP2)

Chromospheric LAyer Spectro-Polarimeter (CLASP2) is our next sounding rocket experiment after the success of Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP1). CLASP2 is scheduled to launch in 2019, and aims to achieve high precision measurements of the linear and circular polarizations in the Mg II h & k lines near the 280 nm, whose line cores originate in the upper solar chromosphere. The CLASP2 spectro-polarimeter follows very successful design concept of the CLASP1 instrument with the minimal modification. A new grating was fabricated with the same radius of curvature as the CLASP1 grating, but with a different ruling density. This allows us to essentially reuse the CLASP1 mechanical structures and layout of the optics. However, because the observing wavelength of CLASP2 is twice longer than that of CLASP1, a magnifier optical system was newly added in front of the cameras to double the focal length of CLASP2 in order to maintain the same wavelength resolution as CLASP1 (0.01 nm). Meanwhile, a careful optical alignment of the specto-polarimeter is required to reach the 0.01 nm wavelength resolution. Therefore, we established an efficient alignment procedure for the CLASP2 spectro-polarimeter based on an experience of CLASP1. Here, we explain in detail the methods for achieving the optical alignment of the CLASP2 spectro-polarimeter and discuss our results by comparing with the performance requirements.

chromosphere; polarimetry; sounding rocket↗

An Optimal Estimation Aerosol Retrieval Algorithm for Lidar-only and Combined Lidar Polarimeter Remote Sensors

Global measurements of aerosol vertical profile, composition, concentration, and size distribution are very important due to aerosol impacts on air quality, climate, clouds, and ocean ecosystems. We have developed a lidar-only and combined lidar and polarimeter algorithm to retrieve vertically-resolved profiles of aerosol microphysical properties. The new retrieval system is modular in design. It consists of three modules, a vertically-resolved aerosol profile retrieval module for lidar data, an aerosol and cloud/ocean retrieval module for polarimeter data, and a combined retrieval module for both lidar and polarimeter measurements. In addition to performing optimal estimation retrievals on various data sources, we have designed the system so that it can be used to carry out aerosol retrieval performance trade studies for various lidar and polarimeter configurations. For example, the retrieval system can take inputs from attenuated backscatter lidar at two wavelengths (e.g. CALIPSO like instrument), aerosol backscattering measured at two wavelengths and and aerosol extinction measured at one wavelength (HSRL-1), or aerosol backscattering measured at three wavelengths and aerosol extinction measured at two wavelengths (HSRL-1) (HSRL-2). We have applied the lidar-only algorithm to both simulated data and various field campaign data (DISCOVER-AQ, CHARMS, TCAP, and ORACLES). For polarimeter-only modules, we have done the same for SABOR, TCAP, NAAMES, and ORACLES data. We have applied the combined retrieval algorithm to ORACLES data. The simulated retrieval studies show that the combined lidar+polarimeter retrieval provides much higher information content relative to their individual counterparts for retrieving effective radius, particle concentrations, and absorption properties.

Xu Liu↗

Pre-Launch Calibration and Validation of the Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) Instrument

The Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) is a new imaging polarimeter instrument capable of sampling a single Earth target from up to 120 viewing angles, in four spectral channels, and in three linear polarization states across a 114° field of view (FOV). AirHARP is telecentric in the image space and simultaneously images three linear polarization states with no moving parts. These two aspects of the design allow for a simple and efficient quantitative calibration. Using coefficients derived at the center of the lens and the detector flatfields, we can calibrate the entire AirHARP sensor in a variety of laboratory, field, and space environments. We show that this telecentric calibration technique yields a 1σ absolute uncertainty of 0.25 % in degree of linear polarization (DOLP) in the laboratory for all channels and for pixels around the optical axis. To validate across the FOV, we compare our multi-angle reflectance and polarization data with the Research Scanning Polarimeter (RSP) over targets sampled during the NASA Aerosol Characterization from Polarimeter and Lidar (ACEPOL) campaign. We use the error-normalized difference technique to estimate how well the instruments compare relative to their error models. We find that AirHARP and the RSP reasonably agree for reflectance and DOLP within 2 standard deviations of their mutual uncertainty at 550, 670, and 870 nm and over a limited set of ocean and desert scenes. This calibration technique makes the Hyper-Angular Rainbow Polarimeter (HARP) design attractive for new spaceborne climate missions: HARP CubeSat (2020–2022), HARP2 (2024–) on the NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE), and beyond.

Airborne Hyper-Angular Rainbow Polarimeter↗

A low-voltage retarding-field Mott polarimeter for photocathode characterization

Nuclear physics experiments at Thomas Jefferson National Accelerator Facility's CEBAF rely on high polarization electron beams. We describe a recently commissioned system for prequalifying and studying photocathodes for CEBAF with a load-locked, low-voltage polarized electron source coupled to a compact retarding-field Mott polarimeter. The polarimeter uses simplified electrode structures and operates from 5 to 30 kV. The effective Sherman function for this device has been calibrated by comparison with the CEBAF 5 MeV Mott polarimeter. For elastic scattering from a thick gold target at 20 keV, the effective Sherman function is 0.201(5). Its maximum efficiency at 20 keV, defined as the detected count rate divided by the incident particle current, is 5.4(2)×10 -4 , yielding a figure-of-merit, or analyzing power squared times efficiency, of 1.0(1)×10 -5 . The operating parameters of this new polarimeter design are compared to previously published data for other compact Mott polarimeters of the retarding-field type.

43 PARTICLE ACCELERATORS↗

High-bandwidth polarimeter for a high density, accelerated spheromak

A three-beam heterodyne polarimeter has been built to diagnose the PI-1 plasma injector at General Fusion, Inc. The polarimeter measures plasma density and Faraday rotation, which can provide estimates of magnetic field magnitude and direction. Two important calibration steps are required for the polarimeter to produce reasonable Faraday rotation signals. Beam polarization ellipticity must be measured to ensure there is a linear Faraday rotation response. In addition, the two beams travelling through the plasma must be collinear to reduce error due to differences in plasma density. Once calibrated, the Faraday rotation signals are in much better agreement with other diagnostics. For a null signal, the Faraday rotation measurement noise floor is 0.1° at 0.5 MHz bandwidth. Comparing preliminary spheromak Faraday rotation measurements to a model, the maximum error is about 0.3° at 0.5 MHz bandwidth, which is primarily due to electrical noise during the injector's capacitor discharge and limitations of the model. At a bandwidth of 0.5 MHz, the polarimeter has an axial resolution between 6 cm and 30 cm depending on the speed of the spheromak, which varies between 30 km/s and 150 km/s. The spheromak length ranges from 0.75 m to 2 m. Additional polarimeter chords will be added in future upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESIGN AND MEASUREMENT OF THE STOKES POLARIMETER FOR THE COSMO K-CORONAGRAPH

We present the Stokes polarimeter for the new Coronal Solar Magnetism Observatory K-coronagraph. The polarimeter can be used in two modes. In observation mode, it is sensitive to linear polarization only and operates as a ''Stokes definition'' polarimeter. In the ideal case, such a modulator isolates a particular Stokes parameter in each modulation state. For calibrations, the polarimeter can diagnose the full Stokes vector. We present here the design process of the polarimeter, analyze its tolerances with a Monte Carlo method, develop a way to align the individual elements, and measure and evaluate its performance in both modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lifetime Estimation of a Time Projection Chamber X-ray Polarimeter

The Gravity and Extreme Magnetism Small Explorer (GEMS) X-ray polarimeter Instrument (XPI) was designed to measure the polarization of 23 sources over the course of its 9 month mission. The XPI design consists of two telescopes each with a polarimeter assembly at the focus of a grazing incidence mirror. To make sensitive polarization measurements the GEMS Polarimeter Assembly (PA) employed a gas detection system based on a Time Projection Chamber (TPC) technique. Gas detectors are inherently at risk of degraded performance arising from contamination from outgassing of internal detector components or due to loss of gas. This paper describes the design and the materials used to build a prototype of the flight polarimeter with the required GEMS lifetime. We report the results from outgassing measurements of the polarimeter subassemblies and assemblies, enclosure seal tests, life tests, and performance tests that demonstrate that the GEMS lifetime is achievable. Finally we report performance measurements and the lifetime enhancement from the use of a getter.

Dimethyl ether↗

Compact LWIR Polarimeter for Cirrus Ice Properties

A miniaturized long-wave InfraRed (LWIR) spectro-polarimeter is being developed as a prototype for the Compact Submm-Wave and LWIR Polarimeters (SWIRP) project. The polarimeter in development is a compact (20x20x40 cm) conical-scan instrument to measure the polarimetric radiation from ice cloud scattering at mm-submm (220 and 680 GHz) and IR (8.6, 11, and 12 m) bands. The LWIR polarimeter will provide a series of polarization measurements across the 8.5 - 12.5 micron band, measuring the full set of linear Stokes parameters (I, Q, U) as a function of wavelength. The spectro-polarimeter uses a combination of birefringent crystals, a Wollaston prism, a diraction grating, and an uncooled microbolometer array to measure both the degree and angle of linear polarization across the spectral bandwidth by modulating the polarization ux in wavelength with a high order retarder.

LWIR↗

Progress of the NASA ACE Mission Polarimeter Working Group Instrument Inter-Comparison

The NASA Aerosol-Cloud-Ecosystem (ACE) mission is a National Research Council Decadal Survey recommended mission that will contain an imaging polarimeter for remote sensing of aerosols and clouds. A variety of airborne polarimeter prototypes exist, so the ACE Polarimeter Working Group (ACEPWG) was formed to share information between groups and collectively work for improved measurement techniques, uncertainty characterization, and algorithm development. The initial focus has been on observations made during the Polarimeter Definition Experiment (PODEX), conducted in early 2013 in Southern California. Three ACE mission supported polarimeters were deployed on the high altitude ER-2 aircraft as it flew over a variety of targets. Two of those instruments to date have successfully produced Level 1 (geolocated radiance and polarization) data. Initial matched scene inter-comparisons found little radiometric, but significant polarimetric, bias. After improvement to geolocation in one instrument, and calibration in the other, polarimetric comparisons have improved significantly. We will describe these results, remaining unresolved issues, and future plans.

Polarimeter↗

Evaluating Combined Lidar and Polarimeter Measurements of Cloud Top Parameters (Extinction, Scattering Cross Sections, and Droplet Number Density, Liquid Water Content)

We present a new method to derive profiles of extinction from a lidar which is then combined with polarimeter measurements to derive cloud droplet number density (CDNC) in the tops of warm clouds. The method employs polarization-sensitive elastic backscatter lidar measurements to estimate attenuation of the lidar signal within the cloud and polarimeter estimates of cloud droplet size distributions. The measurements used for this demonstration are from NASA Langley Research Center’s High Spectral Resolution Lidar – Generation 2 (HSRL-2) and NASA GISS’s Research Scanning Polarimeter (RSP). The measurements were acquired on NASA’s ACTIVATE mission, during which the instruments were deployed in a down-looking mode from a high-altitude aircraft, which flew in coordination with a low-flying aircraft acquiring coincident in situ measurements of cloud droplet size and number. The high vertical (1.25 m) and horizontal (~50 m) sampling resolution of the HSRL-2 data enabled retrievals of single-scattering extinction profiles to within ~2.5 optical depths of cloud top. Another key feature of the method was the well-calibrated measurement of backscatter at cloud top due to using the HSRL technique. The RSP retrievals of cloud droplet effective radius and variance were accomplished using the “cloud-bow” technique. Overall, the technique provides extinction profile estimates for the top 2.5 optical depths of water clouds that can be used to estimate the cloud droplet number density in various types of warm clouds. The mean extinction values at cloud top (0-1 optical depth) are compared against cloud drop size and number concentration acquired from wing-mounted probes (e.g., DMT Cloud Droplet Probe - CDP, SPEC Fast Cloud Droplet Probe FCDP, and SPEC 2D Stereo Probe - 2DS) that were deployed on the low-flying aircraft. Comparisons between the effective radius and variance from the polarimeter, lidar ratio (extinction to backscatter) from the lidar and polarimeter, and LWC are also presented. All measurements were acquired over the Western North Atlantic over 3 years from 2020 to 2022.

lidar↗

Focusing crystal polarimeter designed for X-ray polarimetry - Construction and performance

A method for the construction of a graphite crystal polarimeter designed for measuring linear polarization of X-ray continuum sources is described. The dependence of reflected intensity upon the polarization direction of the incident beam at Bragg angles of 45 deg is used to measure the polarization. The particular instrument described was designed for a satellite X-ray polarimeter. By using a focusing parabolic surface instead of a nonfocusing flat crystal, the signal-to-background ratio is improved by a factor of 30 as compared to a flat crystal polarimeter of the same effective area. The focusing properties of the reflector were tested both optically and with X-rays. The performance of the instrument as a polarimeter was tested with a continuum X-ray source of small polarization, which was independently measured by a single flat crystal polarimeter. The agreement between the two measurements is excellent, indicating that the instrument can measure polarizations as low as 0.3%.

Toraskar, J. R.↗

Canadian Led X-ray Polarimeter Mission CXP

We propose a Canadian-led X-ray Polarimetry Mission (CXP), to include a scattering X-ray Polarimeter and sensitive All-Sky X-ray Monitor (ASXM). Polarimetry would provide a new observational window on black holes, neutron stars, accretion disks and jets, and the ASXM would offer sensitive monitoring of the volatile X-ray sky. The envisioned polarimeter consists of a hollow scattering beryllium cone surrounded by an annular proportional counter, in a simple and elegant design that is reliable and low-risk. It would be sensitive in the 6-30 keV band to approx. 3% polarization in approx. 30 Galactic sources and 2 AGN in a baseline 1-yr mission, and have sensitivity greater than 10 times that of the previous X-ray polarimeter flown (NASA's OSO-8, 1975-78) for most sources. This X-ray polarimeter would tackle questions like, Do black holes spin?, How do pulsars pulse?, What is the geometry of the magnetic field in accreting neutron stars? Where and how are jets produced in microquasars and AGN?, What are the geometries of many of the most famous accretion-disk systems in the sky? This will be done using a novel and until-now unexploited technique that will greatly broaden the available observational phase space of compact objects by adding to timing and spectroscopy observations of polarization fraction and position angle as a function of energy. The All-Sky X-ray Monitor would scan for transients, both as potential targets for the polarimeter but also as a service to the worldwide astronomical community. The entire CXP mission could be flown for $40- 60M CDN, according to estimates by ComDev International, and could be built entirely in Canada. It would fall well within the CSA's SmallSat envelope and would empower the growing and dynamic Canadian High-Energy Astrophysics community with world leadership in a potentially high impact niche area.

Kaspi, V.↗

A Burst Chasing X-ray Polarimeter

Tihs is a viewgraph presentation of a discussion of the X-ray Polarimeter. Gamma-ray bursts are one of the most powerful explosions in the universe and have been detected out to distances of almost 13 billion light years. The exact origin of these energetic explosions is still unknown but the resulting huge release of energy is thought to create a highly relativistic jet of material and a power-law distribution of electrons. There are several theories describing the origin of the prompt GRB emission that currently cannot be distinguished. Measurements of the linear polarization would provide unique and important constraints on the mechanisms thought to drive these powerful explosions. We present the design of a sensitive, and extremely versatile gamma-ray burst polarimeter. The instrument is a photoelectric polarimeter based on a time-projection chamber. The photoelectric time-projection technique combines high sensitivity with broad band-pass and is potentially the most powerful method between 2 and 100 keV where the photoelectric effect is the dominant interaction process We present measurements of polarized and unpolarized X-rays obtained with a prototype detector and describe the two mission concepts, the Gamma-Ray Burst Polarimeter (GRBP) for thc U S Naval Academy satellite MidSTAR-2, and thc Low Energy Polarimeter (LEP) onboard POET, a broadband polarimetry concept for a small explorer mission.

Hill, Joanne↗

Performance of the PRAXyS X-Ray Polarimeter

The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.

PRAXyS↗