Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Restoration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimal Electric Grid Black Start Restoration Subject to Intentional Threats

Efficient restoration of the electric grid from significant disruptions – both natural and manmade – that lead to the grid entering a failed state is essential to maintaining resilience under a wide range of threats. Restoration follows a set of black start plans, allowing operators to select among these plans to meet the constraints imposed on the system by the disruption. Restoration objectives aim to restore power to a maximum number of customers in the shortest time. Current state-of-the-art for restoration modeling breaks the problem into multiple parts, assuming a known network state and full observability and control by grid operators. These assumptions are not guaranteed under some threats. This paper focuses on a novel integration of modeling and analysis capabilities to aid operators during restoration activities. A power flow-informed restoration framework, comprised of a restoration mixed-integer program informed by power flow models to identify restoration alternatives, interacts with a dynamic representation of the grid through a cognitive model of operator decision-making, to identify and prove an optimal restoration path. Application of this integrated approach is illustrated on exemplar systems. Validation of the restoration is performed for one of these exemplars using commercial solvers, and comparison is made between the steps and time involved in the commercial solver, and that required by the restoration optimization in and of itself, and by the operator model in acting on the restoration optimization output. Publications and proposals developed under this work, along with a path forward for additional expansion of the work, and summary of what was achieved, are also documented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Community Resilience Through Rapid Restoration Leveraging Distributed Energy Resources (DERs) and Low-Cost Sensors

Equitable and automated bottoms-up power restoration following an extreme event will be demonstrated at a site in Puerto Rico. To do so, the team will develop enhanced grid situational awareness techniques integrating behind-the-meter (BTM) distributed energy resources (DER) discovery, impedance sweeping based outage boundary detection, and feasible restoration path identification algorithms. Resilience metric will be developed and incorporated along with situational awareness information in a distributed Model Predictive Control (MPC)-based restoration optimization algorithm to control and mobilize grid assets. These algorithms will be validated through power hardware-in-the-loop experiments and ultimately, a site demonstration to show that outage recovery time and total recovered load could be improved by >20% over the baseline.

24 POWER TRANSMISSION AND DISTRIBUTION↗

De-Energized Line Testing Interface (DELTI) Report

To guarantee the safety of power system operations, it is crucial to understand a de-energized power line’s status before restoring power. It is hypothesized that the Grid Resonance Probe (GRP) and De-Energized Line Testing Interface (DELTI) can be utilized to identify a faulted distribution line. Therefore, the project team is targeting development of a methodology to identify faulted distribution lines by using the DELTI system. In this R&D task, two field tests on Plum Island have been conducted, including DELTI tests with multiple configurations and fault scenarios. This report provides the analysis results of distribution line fault identification from the two field tests. In the remainder of this report, Section 1 is the introduction of the DELTI system, Section 2 provides the analyses of the two field tests in June and October of 2021, respectively, Section 3 discusses the existing line fault detection devices on market and how they compare to DELTI and Section 4 includes the lessons learned and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Orbiter Interface Unit and Early Communication System

This report describes the Orbiter Interface Unit (OIU) and the Early Communication System (ECOMM), which are systems of electronic hardware and software that serve as the primary communication links for the International Space Station (ISS). When a space shuttle is at or near the ISS during assembly and resupply missions, the OIU sends groundor crew-initiated commands from the space shuttle to the ISS and relays telemetry from the ISS to the space shuttle s payload data systems. The shuttle then forwards the telemetry to the ground. In the absence of a space shuttle, the ECOMM handles communications between the ISS and Johnson Space Center via the Tracking and Data Relay Satellite System (TDRSS). Innovative features described in the report include (1) a "smart data-buffering algorithm that helps to preserve synchronization (and thereby minimize loss) of telemetric data between the OIU and the space-shuttle payload data interleaver; (2) an ECOMM antenna-autotracking algorithm that selects whichever of two phased-array antennas gives the best TDRSS signal and electronically steers that antenna to track the TDRSS source; and (3) an ECOMM radiation-latchup controller, which detects an abrupt increase in current indicative of radiation-induced latchup and temporarily turns off power to clear the latchup, restoring power after the charge dissipates.

Cobbs, Ronald M.↗

Synergistic Use of Nighttime Satellite Data, Electric Utility Infrastructure, and Ambient Population to Improve Power Outage Detections in Urban Areas

Natural and anthropogenic hazards are frequently responsible for disaster events, leading to damaged physical infrastructure, which can result in loss of electrical power for affected locations. Remotely-sensed, nighttime satellite imagery from the Suomi National Polar-orbiting Partnership (Suomi-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) can monitor power outages in disaster-affected areas through the identification of missing city lights. When combined with locally-relevant geospatial information, these observations can be used to estimate power outages, defined as geographic locations requiring manual intervention to restore power. In this study, we produced a power outage product based on Suomi-NPP VIIRS DNB observations to estimate power outages following Hurricane Sandy in 2012. This product, combined with known power outage data and ambient population estimates, was then used to predict power outages in a layered, feedforward neural network model. We believe this is the first attempt to synergistically combine such data sources to quantitatively estimate power outages. The VIIRS DNB power outage product was able to identify initial loss of light following Hurricane Sandy, as well as the gradual restoration of electrical power. The neural network model predicted power outages with reasonable spatial accuracy, achieving Pearson coefficients (r) between 0.48 and 0.58 across all folds. Our results show promise for producing a continental United States (CONUS)- or global-scale power outage monitoring network using satellite imagery and locally-relevant geospatial data.

da/night band↗

Linear phase demodulator including a phase locked loop with auxiliary feedback loop

A phase modulated wave that may have no carrier power is demodulated by a phase locked loop including a phase detector for deriving an A.C. data output signal having a magnitude and a phase indicative of the phase of the modulated wave. A feedback loop responsive to the data output signal restores power to the carrier frequency component to the loop. In one embodiment, the feedback loop includes a phase modulator responsive to the phase modulated wave and the data output signal. In a second embodiment, carrier frequency power is restored by differentiating the data output signal and supplying the differentiated signal to an input of a voltage controlled oscillator included in the phase locked loop.

Rippy, R. R.↗

Surge protection with automatic reset

Circuit turns power off automatically when surge occurs and restores power when voltage returns to normal. Transmitters and other equipment are protected in electrically noisy environments; however, if three transient overvoltages (or continuous overvoltage) are sensed within 3.2 seconds, circuit turns power supply off permanently since serious failure may have occurred.

Chan, R. B.↗

Blockchain for Fault-Tolerant Grid Operations Version 2.0

This report explores the potential of distributed ledger technology (DLT) as a transformative tool to enhance fault-tolerant operations in electrical distribution systems. Leveraging DLT's core attributes, including an immutable decentralized ledger, distributed consensus mechanisms, and state replication capabilities, this study focuses on three critical use cases. A central aspect of this research centers on the utilization of a consensus-driven ledger, providing actors within the system, such as distributed resources, with access to a reliable data repository. This empowers these actors to collaborate effectively and make informed decisions, all securely recorded on the blockchain. The first use case concentrates on data configuration, utilizing mathematical criteria---particularly, the chi-squared test for gross error detection---to identify trustworthy sensors for advanced decision-making. Building upon this foundation of trust, the second use case, topology identification, accurately determines circuit breaker states, unveiling the distribution network's topology. Ultimately, the third use case leverages this trust to execute switching actions, reconfiguring feeders and restoring power to disconnected customers after fault events. The concept of trust serves as a cornerstone in this approach, marking a departure from traditional fault location, isolation, and service restoration (FLISR) methods. Additionally, the blockchain-based architecture introduces decentralization, empowering disconnected areas to make autonomous decisions, even when communication with a central control center is disrupted. The primary contributions of this report are twofold: (1) a novel approach for evaluating distribution system voltage areas while preserving data ownership and (2) the implementation of interactions between distribution network areas using the actor model. Unlike the previous sequential approach for evaluating the area connection voltages, which required a radial network topology, this study's area model reduction enables a more versatile approach. The area model reduction addresses issues of prolonged data waiting times and multiple points of failure within the previous approach. Notably, the presented evaluation for the reduced network model area connection reveals a significant increase in the differences in voltage magnitudes. Simulation and evaluation of area agents across four distinct cases elucidate the area-level interaction behavior during a fault event. Simulations demonstrate that the proposed distributed FLISR (DFLISR) approach can successfully restore service to an affected area. Varying message delays and message loss probabilities in each simulation case underscore their impacts on restoration times, ranging from 3 min and 32 s to 6 min and 19 s. In contrast, power is not restored in an area in one of our simulation cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SPATIOTEMPORAL TRACKING OF WIDE AREA POWER OUTAGE FROM NIGHT-TIME LIGHT IMAGERY

Monitoring progress of power restoration following extreme events is essential for situational awareness about spatio-temporal distribution of populations without power and to help with response efforts. Because of the proprietary nature of restoration data, and the difficulty in obtaining power outage data from utility companies in near real-time (e.g., during hurricane Maria (2017)), this project used satellite derived nighttime lights data from Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) to (i) monitor wide area power outage and (ii) estimate impacted customers over time to assist with restoration. A discussion of the methodology and its implementation during hurricanes Maria (2017) and Eta (2020) is presented in this paper. Future work will focus on calibrating estimated customers based on light intensity and density distribution, and generation of restoration profiles for emergency response.

Kar, Bandana↗

ENLIGHTEN: Electrical Network Line Inspection Guided by High-Speed Technology & Electromagnetic Navigation

Natural disasters are a major cause of power outages, primarily due to their damage to power line infrastructure. As a result, the current state of power maintenance, with a heavy reliance on manual labor, is in trouble. Its lack of speed and autonomy must be addressed to ensure power security for households and institutions worldwide. This innovative approach explores how High-Speed Unmanned Aerial Vehicle (HSUAV) technology can inspect power line infrastructure rapidly in response to natural disaster scenarios. The HSUAV technology will be accompanied by enhanced sensory equipment including light detection and ranging (LiDAR), thermal imaging, and electromagnetic field (EMF) navigation. It would also be supplemented by innovative forms of machine learning models and recharging systems to efficiently detect anomalies in power line infrastructure. The proposed system, ENLIGHTEN, can help restore power in affected communities after a devastating natural disaster, greatly improving relief efforts. In the future, ENLIGHTEN can be expanded beyond the United States and shared worldwide, effectively mitigating the consequences on a larger scale.

UAV systems, Power line management, Natural disast↗

Prevention of Dual-Mode Excitation in 9-Cell Cavities for LCLSII-HE

Dual-Mode Excitation, also referred to as mode-mixing, is a superposition of two fundamental pi modes in an SRF cavity. In 9-cell TESLA cavities used for the LCLSII-HE project, the two modes that are commonly excited are the pi mode (1300.2 MHz), and the 7/9 pi mode (1297.8 MHz). During vertical cavity qualification testing, only the pi mode is driven by the RF system. However, at high gradients, emitted power at the frequency of the 7/9 pi mode grows despite the RF system only powering the pi mode. When this happens, the RF power measurement system is unable to differentiate between the superimposed modes, and any data taken is invalid. The previous method of dealing with mode-mixing was to turn off power to the cavity, let both modes decay fully, then restore power. Because of the time-sensitive nature of this testing, this leads to underestimates of Q0 or any radiant field emission present in the cavity. The novel RF control solution prevents the 7/9 pi mode from being excited while not interfering with measurements of the fundamental pi mode. A second RF control system is connected to the cavity which drives the 7/9 pi mode. The loop phase for driving the 7/9 pi mode in self excited loop mode is determined then shifted by 180 degrees, thus providing a negative feedback to the undesired mode. Because this off-resonance power can be very small, on the order of milliwatts, it does not interfere with the high-power measurements of the fundamental pi mode. At Jefferson Lab, we are now able to test a cavity for the LCLSII-HE project with no problems from mode-mixing, which allows for CW processing of high-gradient multipacting and field emission.

Owen, Peter↗

High safety and cycling stability of ultrahigh energy lithium ion batteries

High-nickel layered oxide Li-ion batteries (LIBs) dominate the electric vehicle market, but their potentially poor safety and thermal stability remain a public concern. Here, we show that an ultrahigh-energy LIB (292 Wh kg –1 ) becomes intrinsically safer when a small amount of triallyl phosphate (TAP) is added to standard electrolytes. TAP passivates the electrode-electrolyte interfaces and limits the maximum cell temperature during nail penetration to 55°C versus complete cell destruction (>950°C) without TAP. The downside of this reliable safety solution is higher interfacial impedance and hence lower battery power; however, thermal modulation for battery operation around 60°C can restore power completely. When cycled at 60°C, the cell stabilized with TAP achieved 2,413 cycles at 76% capacity retention. Such an unconventional combination of interface-passivating electrolyte additive with cell thermal modulation renders the most energy-dense LIBs even safer than LiFePO 4 chemistry, while enjoying high power and cycling stability concurrently.

25 ENERGY STORAGE↗

Novel Fault Location Method for Power Systems Based on Attention Mechanism and Double Structure GRU Neural Network

Fault location is one of the most essential techniques to maintain the stable operation of power systems. A fast and accurate fault location allows operators to restore power grids faster and avoid economic losses. Conventional methods rely on expert knowledge to extract the necessary features (e.g. DWT, DFT). For large systems, more coupling effects of transmission lines require more complex feature engineering, and incomplete features can easily introduce large errors. To overcome this, a deep learning approach without manual feature extraction is introduced to the fault location model under big data application. Towards this end, in the proposed method, the attention mechanism, the Bi-GRU and a dual structure network are applied to analyze the current data from different perspectives. Complete information for the fault features is extracted for the fault location. Based on a time series model and benefit from the ability to internally acquire the information architecture of faulty line, the established model is adaptive to the power grids with very complex topologies. Simulation results indicate that the proposed double-structure model reduces the maximum error and is less affected by noise. In comparison with different structures and different models, the proposed method shows better performance in IEEE 39-bus system.

42 ENGINEERING↗

On the Use of Satellite Nightlights for Power Outages Prediction

Hurricanes are a dominant disaster in the Caribbean, always causing serious power outages throughout the islands. Hurricane Maria was a prime example, causing unimaginable destruction of the power infrastructure of Puerto Rico (PR). Consequently, one month after the hurricane landfall, approximately 80% of the population was still without power. After an event of such massive destruction, the electric power restoration process progresses very slowly. This timeline can be improved using power outage (PO) forecast models that help identify the vulnerable places before the hurricane landfall. Generally, these models are trained with historical power outages records, associated data on weather conditions, and additional information about the natural and built environments. However, PO records are often difficult to acquire, and, in many instances, the power utility companies may not record them. This study utilizes a satellite-based Visible Infrared Imaging Radiometer Suite (VIIRS) night light data product as a surrogate for the power delivery to predict hurricane-induced PO in areas having limited to nonexistent historical data records. The processed satellite data is then used along with geographic variables, and simulated weather data to formulate machine learning-based algorithms to predict PO for future hurricane events. These models are applied and validated in the context of the PR catastrophic storm, Hurricane Maria.

54 ENVIRONMENTAL SCIENCES↗

Kickstart Your Federal Microgrid Resiliency Project: Financing Opportunities and Best Practices

Recent high-impact events such as hurricanes and wildfires have resulted in the loss of utility grid power to federal sites, highlighting the need for energy system resilience. To sustain critical functions, site loads may need to operate during an electric grid outage or at least have power restored quickly after the event. A microgrid can provide reliable backup power to critical loads when electric utility power is interrupted, and may also provide value during normal operations.

DER↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration: Preprint

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Financing Microgrids in the Federal Sector

Recent high-impact events such as hurricanes and wildfires highlight the need for energy system resilience. One potential impact of these events is the loss of utility grid power to federal sites, negatively affecting the ability to carry out their missions. Depending on the need to sustain critical functions, it may be important to continue operations during an outage of the electric grid, or at least have power restored quickly after the event. One approach to addressing this need is through a microgrid. Microgrids can provide a more reliable solution than the traditional approach of using a backup generator at individual buildings. A microgrid can enhance a site’s electrical power system during normal operations, as well as provide reliable backup power to critical loads when electric utility power is interrupted. Many times, certain components of a microgrid (and potentially the entire system) can be justified economically and paid for out of energy savings or avoided costs. In cases where savings can cover the project costs, one of several privately financed procurement mechanisms may be used to implement the project. Procurement options available to all federal agencies include utility energy services contracts (UESC), energy savings performance contracts (ESPC), and utility services contracts (USC); other mechanisms such as a power purchase agreement (PPA), enhanced use lease (EUL), and utility privatization (UP) may also be useful to agencies that have the authority to use them. Implementing a microgrid in a comprehensive effort that also includes energy efficiency can provide an important savings component, while reducing power requirements for critical loads, thus reducing the cost of the microgrid and associated distributed energy resources (DER). However, it can be difficult to achieve enough savings and avoided costs to cover the entire microgrid system, so leveraging these avoided costs in combination with appropriated funds may be necessary to implement the full project. When a site is deciding if a microgrid is the best solution, activities early in the process include identifying critical loads and existing DERs, conversations with the local electric utility, and implementation options that work best for the agency and site. This paper explores procurement options and agreements that may be useful to federal agencies interested in implementing microgrids at their sites. Microgrid complexities, implementation considerations, and suggestions to get started are also discussed. This information will be most useful to agencies when they are exploring electric energy system resilience options and/or considering different procurement options to meet their needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Financing Microgrids in the Federal Sector

Recent high-impact events such as hurricanes and wildfires highlight the need for energy system resilience. One potential impact of these events is the loss of utility grid power to federal sites, negatively affecting the ability to carry out their missions. Depending on the need to sustain critical functions, it may be important to continue operations during an outage of the electric grid, or at least have power restored quickly after the event. One approach to addressing this need is through a microgrid. Microgrids can provide a more reliable solution than the traditional approach of using a backup generator at individual buildings. A microgrid can enhance a site’s electrical power system during normal operations, as well as provide reliable backup power to critical loads when electric utility power is interrupted. Many times, certain components of a microgrid (and potentially the entire system) can be justified economically and paid for out of energy savings or avoided costs. In cases where savings can cover the project costs, one of several privately financed procurement mechanisms may be used to implement the project. However, it can be difficult to achieve enough savings and avoided costs to cover the entire microgrid system, so leveraging these avoided costs in combination with appropriated funds may be necessary to implement the full project. This paper explores procurement options and agreements that may be useful to federal agencies interested in implementing microgrids at their sites. Microgrid complexities, implementation considerations, and suggestions to get started are also discussed. This information will be most useful to agencies when they are exploring electric energy system resilience options and/or considering different procurement options to meet their needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗