A Distributed Power System Control Architecture for Improved Distribution System Resiliency
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Electric power grids are being stressed by integration of intermittent renewable resources and significant adoption of distributed energy resources. The complexity of the grid is growing rapidly as we attempt to support technical, business, and societal goals for which power grids were not originally designed. Today, we largely take stability of the grid for granted. Stability could significantly degrade or collapse because of new dynamics introduced to the grid, and because the emerging extreme complexity makes traditional control analysis intractable, so that grid behavior is more unpredictable than in the past. This paper describes emerging issues in grid control and provides reasons why the present path of grid control evolution is problematic and presents an ultra-large scale framework for grid control that can solve today’s problems and those expected over the next 30 years. Failure to address these issues in the short term will result in rapidly escalating system deployment and maintenance costs, potential stranded assets related to replacement of the “ad hoc” systems, along with substantial operational risks that are unacceptable under current utility and regulatory practices.
The model of the system assumes a constant power source and loads (experiments) whose power demands exceed the supply. Experiments are described by their name, power consumption, time for a complete run, present status and the state of the load. The power consumption of each load is set at a constant level but can be dynamically modified by the operator. The status specifies if the experiment is running, paused, completed or failed. The state compensates for the lack of actual feedback sensor data, by signifying the stability of the load. Experiments are scheduled to keep as many running as possible with the current system limitations. A graphics oriented user interface is embedded into the rule-based system to enable an operator to easily experiment with the system.
Explore the source record for details and available documents.
Here, this paper develops a risk-aware controller for grid-forming inverters (GFMs) to minimize large frequency oscillations in GFM inverter-dominated power systems. To tackle the high variability from loads/renewables, we incorporate a mean-variance risk constraint into the classical linear quadratic regulator (LQR) formulation for this problem. The risk constraint aims to bound the time-averaged cost of state variability and thus can improve the worst-case performance for large disturbances. The resulting risk-constrained LQR problem is solved through the dual reformulation to a minimax problem, by using a reinforcement learning (RL) method termed as stochastic gradient-descent with max-oracle (SGDmax). In particular, the zero-order policy gradient (ZOPG) approach is used to simplify the gradient estimation using simulated system trajectories. Numerical tests conducted on the IEEE 68-bus system have validated the convergence of our proposed SGDmax for GFM model and corroborate the effectiveness of the risk constraint in improving the worst-case performance while reducing the variability of the overall control cost.
The NASA LeRC in Cleveland, Ohio has completed the development and integration of a Power Management and Distribution (PMAD) DC Testbed. This testbed is a reduced scale representation of the end to end, sources to loads, Space Station Freedom Electrical Power System (SSF EPS). This unique facility is being used to demonstrate DC power generation and distribution, power management and control, and system operation techniques considered to be prime candidates for the Space Station Freedom. A key capability of the testbed is its ability to be configured to address system level issues in support of critical SSF program design milestones. Electrical power system control and operation issues like source control, source regulation, system fault protection, end-to-end system stability, health monitoring, resource allocation, and resource management are being evaluated in the testbed. The SSF EPS control functional allocation between on-board computers and ground based systems is evolving. Initially, ground based systems will perform the bulk of power system control and operation. The EPS control system is required to continuously monitor and determine the current state of the power system. The DC Testbed Control System consists of standard controllers arranged in a hierarchical and distributed architecture. These controllers provide all the monitoring and control functions for the DC Testbed Electrical Power System. Higher level controllers include the Power Management Controller, Load Management Controller, Operator Interface System, and a network of computer systems that perform some of the SSF Ground based Control Center Operation. The lower level controllers include Main Bus Switch Controllers and Photovoltaic Controllers. Power system status information is periodically provided to the higher level controllers to perform system control and operation. The data acquisition function of the control system is distributed among the various levels of the hierarchy. Data requirements are dictated by the control system algorithms being implemented at each level. A functional description of the various levels of the testbed control system architecture, the data acquisition function, and the status of its implementationis presented.
A detailed computer simulation was used to illustrate the steady-state and dynamic operating characteristics of a 20-kHz resonant spacecraft power system. The simulated system consists of a parallel-connected set of DC-inductor resonant inverters (drivers), a 440-V cable, a node transformer, a 220-V cable, and a transformer-rectifier-filter (TRF) AC-to-DC receiver load. Also included in the system are a 1-kW 0.8-pf RL load and a double-LC filter connected at the receiving end of the 20-kHz AC system. The detailed computer simulation was used to illustrate the normal steady-state operating characteristics and the dynamic system performance following, for example, TRF startup. It is shown that without any filtering the given system exhibits harmonic resonances due to an interaction between the switching of the source and/or load converters and the AC system. However, the double-LC filter at the receiving-end of the AC system and harmonic traps connected in series with each of the drivers significantly reduce the harmonic distortion of the 20-kHz bus voltage. Significant additional improvement in the waveform quality can be achieved by including a double-LC filter with each driver.
Explore the source record for details and available documents.
On July 10, 2003, the NASA Glenn Research Center flywheel team experimentally demonstrated a two-flywheel-module system that simultaneously provided attitude control in a single axis and regulated power. The test was conducted using the D1 flywheel module and the high-speed shaft (HSS) in the High Energy Flywheel Facility (HEFF). Both of these flywheel modules consist of a magnetically levitated rotor with an integral motor/generator, a vacuum housing, and mechanical touchdown bearings. Energy is stored kinetically in the rotor. The motor/generator allows energy to be added to or withdrawn from the rotor, and magnetic bearings and a vacuum enclosure are used to minimize losses.
Renewables are key enablers for the realization of a sustainable energy supply but grid operators and energy utilities have to mange their intermittent behavior and limited storage capabilities by ensuring the security of supply and power quality. Advanced control approaches, automation concepts, and communication technologies have the potential to address these challenges by providing new intelligent solutions and products. However, the validation of certain aspects of such smart grid systems, especially advanced control and automation concepts is still a challenge. The main aim of this work therefore is to introduce a hardware-in-the-loop co-simulation-based validation framework which allows the simulation of large-scale power networks and control solutions together with real-world components. The application of this concept to a selected voltage control example shows its applicability.
Abstract not provided.
Not provided.
Explore the source record for details and available documents.
Abstract not provided
The surface tension driven convection experiment (STDCE) is a Space Transportation System flight experiment manifested to fly aboard the USML-1 Spacelab mission. A CO2 laser is used to heat a spot on the surface of silicone oil contained inside a test chamber. Several CO2 laser control systems were evaluated and the selected system will be interfaced with the balance of the experimental hardware to constitute a working engineering model. Descriptions and a discussion of these various design approaches are presented.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.