Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Precision measurement of the $Ξ^0_b$ baryon lifetime

A sample of 𝑝⁢𝑝 collision data, corresponding to an integrated luminosity of 5.4 fb −1 and collected by the LHCb experiment during LHC Run 2, is used to measure the ratio of the lifetime of the $Ξ^0_b$ baryon to that of the $Λ^0_b$ baryon, 𝑟 𝜏 $≡$ $𝜏_{Ξ^0_b}$$/𝜏_{Λ^0_b}$. The value 𝑟$^{\textrm{Run 2}}_𝜏$ =1.004 ± 0.009 ± 0.006 is obtained, where the first uncertainty is statistical and the second systematic. This value is averaged with the corresponding value from Run 1 to obtain 𝑟 𝜏 =1.004 ± 0.008 ± 0.005. Multiplying by the known value of the $Λ^0_b$ lifetime yields $𝜏_{Ξ^0_b}$ = 1.475 ± 0.012 ± 0.008 ± 0.009 ps, where the last uncertainty is due to the limited knowledge of the $Λ^0_b$ lifetime. This measurement improves the precision of the current world average of the $Ξ^0_b$ lifetime by about a factor of two, and is in good agreement with the most recent theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A precision measurement of the X-ray polarization of the Crab Nebula without pulsar contamination

The linear X-ray polarization of the Crab Nebula has been precisely measured at 2.6 keV and 5.2 keV with the OSO 8 graphite crystal polarimeters. The 1.4 ms time resolution of these instruments permitted the removal of any contribution to the polarization from the pulsar. The nebular polarization is 19.2% plus or minus 1.0% at a position angle of 156.4 plus or minus 1.4 deg at 2.6 keV. At 5.2 keV the corresponding results are 19.5% plus or minus 2.8% at 152.6 plus or minus 4.0 deg.

Weisskopf, M. C.↗

Precise Measurement for Manufacturing

A metrology instrument known as PhaseCam supports a wide range of applications, from testing large optics to controlling factory production processes. This dynamic interferometer system enables precise measurement of three-dimensional surfaces in the manufacturing industry, delivering speed and high-resolution accuracy in even the most challenging environments.Compact and reliable, PhaseCam enables users to make interferometric measurements right on the factory floor. The system can be configured for many different applications, including mirror phasing, vacuum/cryogenic testing, motion/modal analysis, and flow visualization.

Source record↗

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Inference of Hybrid Star Properties from Future High-precision Measurements of Their Radii

Future high-precision X-ray and gravitational-wave observations of neutron stars (NSs) are expected to constrain NS radii with uncertainties as small as σ ≃ 0.1 km. Such unprecedented precision offers a unique opportunity to extract new information about the nature and equation of state (EOS) of supradense matter in NS cores. Using mock radius data with uncertainties ranging from σ = 1.0 to 0.1 km, together with a flexible meta-model NS EOS that allows for a first-order hadron–quark phase transition, we perform a Bayesian statistical analysis to assess the impact of radius measurements on EOS constraints. We find that high-precision radius measurements, particularly for massive NSs, significantly tighten constraints on the hadron–quark transition density ρ t , the quark matter mass fraction in NS cores, and several parameters characterizing the EOS of supranuclear hadronic matter, although the degree of improvement depends on the assumed prior range of ρ t . In contrast, even with the highest precision considered, NS radii—including those of massive stars—remain largely insensitive to the stiffness of quark matter, independent of the measurement accuracy or the prior range adopted for ρ t .

Neutron stars↗

Progress on Passive Sensor for Ultra-Precise Measurement of C02

We will present results from a novel instrument employing a Fabry-Perot interferometer to measure column carbon dioxide with great precision. These measurements are very important for improving our understanding of the global warming phenomenon. The instrument technique can be extended to a number of other important trace gases in the atmosphere.

Heaps, William S.↗

Precise Measurement of the Neutron Magnetic Form Factor Using Super-BigBite Spectrometer at Jefferson Lab

The GMn experiment (E12-09-019) was conducted at Jefferson Laboratory from late 2021 into early 2022. The goal was to make high-precision measurement of the neutron’s magnetic form factor (GMn) at multiple kinematic points, including Q2 = 3.5, 4.5, 6.5, 8.5, 10, 12, 13.5, 16, and 18 (GeV/c)2. Limited data exist for GMn in the region up to about Q2 = 10 (GeV/c)2, with existing data having large systematic uncertainty. In this experiment, the ratio method was employed to reduce systematic uncertainty by measuring the ratio of neutron and proton yields. The experiment took place at Jefferson Laboratory in Hall A, where the BigBite spectrometer was used to detect the scattered electrons, while the HCal in the SuperBigbite spectrometer was used to detect both neutrons and protons. The protons were deflected slightly upwards with the use of a large-aperture dipole magnet named BigBen, allowing for enhanced particle identification. Extraction of GMn requires taking the ratio of proton and neutron yields. Analysis efforts are still currently underway to refine corrections to the data, including detector efficiencies, radiative corrections, neutron and proton mass identification, and charge exchange.

Lashley-Colthirst, Nathaniel↗

Precise Measurement of the e + e − → D s + D s − Cross Section at Center-of-Mass Energies from Threshold to 4.95 GeV

Using the e + e − collision data collected with the BESIII detector operating at the BEPCII collider, at center-of-mass energies from the threshold to 4.95 GeV, we present precise measurements of the cross section for the process e + e − → D s + D s − using a single-tag method. The resulting cross section line shape exhibits several new structures, thereby offering an input for a future coupled-channel analysis and model tests, which are critical to understand vector charmonium-like states with masses between 4 and 5 GeV. Published by the American Physical Society 2024

Ablikim, M.↗

Precision Measurement of Black Hole Binary Dynamics: Analyzing the LISA Data Stream

One of the richest potential sources of insight into fundamental physics that LISA will be capable of observing is the inspiral of supermassive black hole binaries (BHBs). However, the data analysis challenge presented by the LISA data stream is quite unlike the situation for present day gravitational wave detectors. In order to make the precision measurements necessary to achieve LISA's science goals, the BHB signal must be distinguished from a data stream that not only contains instrumental noise, but potentially thousands of other signals as well, so that the "background" we wish to separate out to focus on the BHB signal is likely to be highly nonstationary and nongaussian, as well as being of scientific interest in its own right. In addition, whereas the theoretical templates that we calculate in order to ultimately estimate the parameters can afford to be somewhat inaccurate and still be effective for present day and near future detectors, this is not the case for LISA, and extremely high fidelity of the theoretical templates for high signal-to-noise signals will be required to prevent theoretical errors from dominating the parameter estimates. NVe, will describe efforts in the community of LISA data analysts to address the challenges regarding the specific issue of BHB signals. These efforts include using a Markov Chain Monte Carlo approach with the freedom to model the BHB and the other signals present in the data stream simultaneously, rather than trying to remove other signals and risk biasing the remaining data. The Mock LISA Data Challenge is a community of LISA scientists who generate rounds of simulated LISA noise with increasingly difficult signal content, and invite the LISA data analysis community to exercise their methods, or develop new methods, in an attempt to extract the parameters for the signals embedded in the mock data. In addition to practical approaches such ,is this to assess the level of parameter accuracy, one can apply the Fisher matrix formalism to assess both the statistical errors from noise and the theoretical errors

McWilliams, Sean T.↗

Development of a Fabry-Perot Interferometer for Ultra-Precise Measurements of Column CO2

A passive Fabry-Perot based instrument is described for detecting column CO2 through absorption measurements at 1.58 microns . In this design, solar flux reaches the instrument platform and is directed through two channels. In the first channel, transmittance fi5nges from a Fabry-Perot interferometer are aligned with CO2 absorption lines so that absorption due to CO2 is primarily detected. The second channel encompasses the same frequency region as the first, but is comparatively more sensitive to changes in the solar flux than absorption due to CO2. The ratio of these channels is sensitive to changes in the total CO2 column, but not to changes in solar flux. This inexpensive instrument will offer high precision measurements (error 4%) in a compact package. Design of this instrument and preliminary ground-based measurements of column CO2 are presented here as well as strategies for deployment on aircraft and satellite platforms.

Wilson, Emily L.↗

Development of Metallic Magnetic Calorimeters for High Precision Measurements of Calorimetric Re-187 and Ho-163 Spectra

The measurement of calorimetric spectra following atomic weak decays, beta (b) and electron capture (EC), of nuclides having a very low Q-value, can provide an impressively high sensitivity to a non-vanishing neutrino mass. The achievable sensitivity in this kind of experiments is directly connected to the performance of the used detectors. In particular an energy resolution of a few eV and a pulse formation time well below 1 microsecond are required. Low temperature Metallic Magnetic Calorimeters (MMCs) for soft X-rays have already shown an energy resolution of 2.0 eV FWHM and a pulse rise-time of about 90 ns for fully micro-fabricated detectors. We present the use of MMCs for high precision measurements of calorimetric spectra following the beta-decay of Re-187 and the EC of Ho-163. We show results obtained with detectors optimized for Re-187 and for Ho-163 experiments respectively. While the detectors equipped with superconducting Re absorbers have not yet reached the aimed performance, a first detector prototype with a Au absorber having implanted Ho-163 ions already shows excellent results. An energy resolution of 12 eV FWHM and a rise time of 90 ns were measured.

Ranitzsch, P. C.-O.↗

High precision measurements of α 𝑠 at the future EIC

Here, we present a projection study for the first moments of the inclusive spin structure function ∫𝑔 1 ⁡(𝑥,𝑄 2 )𝑑𝑥 for the proton and neutron from simulated doubly-polarized $\overrightarrow{e}$ $⁢\overrightarrow{p}$ and $\overrightarrow{e}$ − $\overrightarrow{^{3}He}$ collision data expected from the Electron Ion Collider. For detection and extraction of the neutron spin asymmetries from $\overrightarrow{e}$ − $\overrightarrow{^{3}He}$ collisions, we used the double-tagging method which significantly reduces the uncertainty over the traditional inclusive method. Using the Bjorken Sum Rule, the projected results allow us to determine that the QCD coupling at the 𝑍-pole 𝛼 𝑠 ⁡(𝑀$^2_{Z^0}$) can be measured with a relative precision of 1.3%. This underscores the significance of the EIC for achieving precision determinations of 𝛼 𝑠 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision measurement of the B0 meson lifetime using B0→J/ψK∗0 decays with the ATLAS detector

A measurement of the B0$$B^{0}$$ meson lifetime using B0→J/ψK∗0$$ B^{0} \rightarrow J/\psi K^{*0} $$ decays in data from 13 TeV$$\text {TeV}$$ proton–proton collisions with an integrated luminosity of 140fb-1$$ 140~\mathrm {fb^{-1}} $$ recorded by the ATLAS detector at the LHC is presented. The measured effective lifetime is τ=1.5053±0.0012(stat.)±0.0035(syst.)ps.$$ \tau = 1.5053\pm 0.0012~\mathrm {(stat.)} \pm 0.0035~\mathrm {(syst.)~ps}. $$The average decay width extracted from the effective lifetime, using parameters from external sources, is Γd=0.6639±0.0005(stat.)±0.0016(syst.)±0.0038(ext.)ps-1,$$\begin{aligned} \Gamma _d = 0.6639\pm 0.0005~\mathrm {(stat.)} \pm 0.0016~\mathrm {(syst.)}\\ \pm 0.0038~\text {(ext.)} \text {~ps}^{-1}, \end{aligned}$$where the uncertainties are statistical, systematic and from external sources. The earlier ATLAS measurement of Γs$$\Gamma _s$$ in the Bs0→J/ψϕ$$B^{0}_{s} \rightarrow J/\psi \phi $$ decay was used to derive a value for the ratio of the average decay widths Γd$$\Gamma _d$$ and Γs$$\Gamma _s$$ for B0$$B^{0} $$ and Bs0$$B^{0}_{s} $$ mesons respectively, of ΓdΓs=0.9905±0.0022(stat.)±0.0036(syst.)±0.0057(ext.).$$ \frac{\Gamma _d }{\Gamma _s } = 0.9905\pm 0.0022~\text {(stat.)} \pm 0.0036~\text {(syst.)} \pm 0.0057~\text {(ext.)}. $$The measured lifetime, average decay width and decay width ratio are in agreement with theoretical predictions and with measurements by other experiments. This measurement provides the most precise result of the effective lifetime of the B0$$B^{0}$$ meson to date.

Aad, G↗

Prospects for Precision Measurement of CO2 Column from Space

In order to address the problem of sources and sinks of CO2 measurements are needed on a global scale. Clearly a satellite is a promising approach to meeting this requirement. Unfortunately, most methods for making a CO2 measurement from space involve the whole column. Since sources and sinks at the surface represent a small perturbation to the total column one is faced with the need to measure the column with a precision better than 1%. No species has ever been measured from space at this level. We have developed over the last 3 years a small instrument based upon a Fabry-Perot interferometer that is very sensitive to atmospheric CO2 and has a high signal to noise ratio. We have tested this instrument in a ground based configuration and from aircraft platforms simulating operation from a satellite. We will present results from these tests and discuss ways that this promising new instrument could be used to improve our understanding of the global carbon budget.

Heaps, William S.↗

Highly charged ion approach to measure nuclear charge radii of Fr, Ra, and Rn isotopes for precision measurements

Conventional electron scattering and muonic atom spectroscopy techniques are challenging to apply to heavy ions unless the element has at least one stable or extremely long-lived isotope. To overcome this limitation, a recently introduced method for determining nuclear charge radii relies on extreme-ultraviolet (EUV) spectroscopy of the D 1 line in highly charged Na-like ions. In this work, we present an experimental approach to measure the nuclear charge radii of isotopes of radioactive elements such as Fr, Ra, and Rn using this method at TRIUMF’s Ion Trap for Atomic and Nuclear Science (TITAN) instrument, located at the ISAC radioactive beam facility. We also explore the potential of using Na-like D 2 lines in the soft x-ray region for future measurements.

Electron beam ion trap↗

Progress on Passive Sensor for Ultra-Precise Measurement of Carbon Dioxide from Space

Global measurements of atmospheric carbon dioxides (CO2) are needed to resolve significant discrepancies that exist in our understanding of the global carbon budget and, therefore, man's role in global climate change. The science measurement requirements for CO2 are extremely demanding (precision c .3%) No atmospheric chemical species has ever been measured from space with this precision. We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere. Preliminary design studies indicate that the method will be able to achieve the sensitivity and signal-to-noise required to measure column CO2 at the target specification. We are presently engaged in the construction of a prototype instrument for deployment on an aircraft to test the instrument performance and our ability to retrieve the data in the real atmosphere. In the first 6 months we have assembled a laboratory bench system to begin testing the optical and electronic components. We are also undertaking some measurements of signal and noise levels for actual sunlight reflecting from the ground. We shall present results from some of these ground based studies and discuss their implications for a space based system.

Heaps, William S.↗

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessing the Impact of Measurement Precision on Metabolite Identification Probability in Multidimensional Mass Spectrometry-Based, Reference-Free Metabolomics

Identification of compounds with minimal ambiguity remains a central challenge in mass spectrometry-based metabolomics. Conventional compound identification relies on comparing analytical signatures (e.g., mass-to-charge ratio, collision cross section, tandem mass spectra) against reference data obtained from measurements of authentic chemical standards. The breadth of annotatable compounds using this approach is necessarily limited by availability of authentic standards, analytical throughput, and resolving power of the separations that underly the measurements. The maturation of computational methods, both theory-driven and artificial intelligence/machine learning-based, for prediction of various molecular properties relevant to multidimensional mass spectrometry measurements has opened the door to a new “reference-free” paradigm of compound annotation. Through augmenting existing reference data for molecular properties with computational predictions, the universe of identifiable chemical species can be expanded significantly beyond its current limits. An unexplored aspect of this novel approach is understanding how to gauge confidence in resulting annotations, especially as the compound search space is expanded. Intuitively, the confidence of a compound annotation is related to the inherent discriminatory power of the molecular properties used for identification, as well as the precision with which the properties are measured or predicted. In this work, we characterize this relationship between measurement precision and identification probability in a systematic and quantitative fashion for a defined region of chemical space that includes organic small molecule metabolites. Importantly, this work establishes a framework for conducting metabolite identification probability analysis that enables others to quantify this relationship for their own compounds and properties of interest.

Metabolite Identification↗