Search NASASearch

SEARCH · Search NASA

Results for “RESOLVING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Near-infrared spectroscopy of planetary nebulae: How strong is the H2 emission?

In an effort to understand the systematics of the H2 emission from planetary nebulae, a program of near-infared spectroscopy using the University of Texas infrared reticon spectrometer was started. This instrument has a 1x32 element InSb photodiode array as a detector. All of the observations reported were made on the McDonald Observatory 2.7 m telescope, with spectra resolving power lambda/delta lambda = 600. The spectral coverage allows the measurement strengths of Brackett gamma He I 2.113 microns, HE II 2.189 microns and the v = 1=0 S(1) line of H2 at 2.122 microns. One of the most important advantages of this instrument is that we are able to resolve H2 from the adjacent He I line. Most previous observations of planetaries have been made at spectral resolving powers of about 100, which blend these lines. The contribution of the He I line has generally been dismissed as being unimportant, but we show that this may not be valid. Our higher resolving power also improves the line-to-continuum contrast; in some cases, the continuum is the limiting factor in detecting faint lines.

Dinerstein, H. L.

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)

Micro-spec: an Integrated Direct-detection Spectrometer for Far-infrared Space Telescopes

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements.Micro-Spec (μ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 (micrometers) wavelength range which will enable a wide range of flight missions that would otherwise be challenging due tothe large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 sq cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for micro-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance.Two point designs with resolving power of 260 and 520 and an RMS phase error less than approximately 0.004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

Far-infrared

Experiment for Cryogenic Large-Aperture Intensity Mapping: Instrument Design

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne tele-33scope designed to survey star formation in windows from the present to z=3.5. During this time, the rate of star34formation dropped dramatically, while dark matter continued to cluster. EXCLAIM maps the redshifted emission35of singly-ionized carbon lines and carbon monoxide using intensity mapping, which permits a blind and complete36survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity37using a cryogenic telescope coupled to six integrated spectrometers employing kinetic inductance detectors covering38420540GHz with spectral resolving power R=512and angular resolution⇡40. The spectral resolving power and39cryogenic telescope allow the survey to access dark windows in the spectrum of emission from the upper atmosphere.40EXCLAIM will survey305 deg2in the Sloan Digital Sky Survey Stripe 82 field from a conventional balloon flight41in 2023. EXCLAIM will also map several galactic fields to study carbon monoxide and neutral carbon emission as42tracers of molecular gas. Here, we summarize the design phase of the mission.

Eric R Switzer

Spectra of cosmic X-ray sources

X-ray measurements provide the most direct probes of astrophysical environments with temperatures exceeding one million K. Progress in experimental research utilizing dispersive techniques (e.g., Bragg and grating spectroscopy) is considerably slower than that in areas utilizing photometric techniques, because of the relative inefficiency of the former for the weak X-ray signals from celestial sources. As a result, the term "spectroscopy" as applied to X-ray astronomy has traditionally satisfied a much less restrictive definition (in terms of resolving power) than it has in other wavebands. Until quite recently, resolving powers of order unity were perfectly respectable, and still provide (in most cases) the most useful spectroscopic data. In the broadest sense, X-ray photometric measurements are spectroscopic, insofar as they represent samples of the overall electromagnetic continua of celestial objects.

Holt, S. S.

A faint object spectrometer for the infrared

A cryogenic astronomical spectrometer for the NASA Infrared Telescope Facility is described. This spectrometer will employ an array of at least 20 detectors and provide a resolving power of 100 to 1500 at 1-5 microns. The resolving power will be adjustable by changing gratings.

Tokunaga, A. T.

Oxygen Isotopic Composition of Refractory Inclusions from the Miller Range (MIL) 090019 Carbonaceous Chondrite

Introduction: Primitive meteorites contain Calcium-Aluminum-rich Inclusions (CAIs)that preserve the records of the earliest times in the Solar System. CAIs record O isotopic variations with time and/or location from solar (16O-rich) to planetary (16O-poor) compositions [e.g., 1, 2].However, CAIs were also affected by parent body processing to varying degrees. The goal of this work was to identify the processes that resulted in the fine-scale spatial variations in oxygen isotopic compositions within the most ancient Solar System solids. We report oxygen isotopic composition of CAIs from MIL 090019 CO3.1 carbonaceous chondrite. MIL 090019 contains a high abundance of CAIs showing mineralogical as well as textural variations [3]. Methods: We analyzed 10 CAIs with different mineralogical assemblages, classified as corundum-bearing, grossite-bearing, hibonite-bearing, melilite-bearing, anorthite-bearing inclusions and amoeboid olivine aggregates(AOA’s). The mineralogical and petrological characterization of CAIs was performed using the JOEL Hyperprobe 8530 electron microprobe at NASA JSC. Oxygen isotopic imaging of the CAIs was done using the Cameca NanoSIMS 50L ion microprobe at NASA JSC. We followed the analytical protocol described in [4]. O-isotopic maps of the CAI were acquired by rastering a ~3 pA primary Cs+beam at 16 keVover an area of 20 ×20μm2over a period of ~7 hours. Negative secondary ions of 16O−, 17O−, 18O−, 28Si−, 24Mg16O−, 27Al16O−, and 40Ca16O−were simultaneously acquired using electron multiplier detectors at a mass resolving power sufficient to resolve the 16OH−interference from the 17O−peak, where the contribution of 16OH−was <0.1%.An electron flood gun was used to mitigate sample charging during the analyses. We used San Carlos olivine and Madagascar hibonite as isotopic standards to correct for the instrumental mass fractionation. The O-isotopic ratios were corrected for the quasi simultaneous arrival (QSA) effect and the detector dead time. All reported errors are 1 sigma. Results: The MIL 090019 carbonaceous chondrite hosts refractory inclusions varying in their mineralogies and textures[2, 3]. We found the oxygen isotopic compositions of mineral phases in MIL 090019 CAIs show large variations with Δ17O values varying from -27 to 0‰. A corundum-bearing inclusion records isotopic variations with corundum, melilite, perovskite, and anorthite showing Δ17Ovalues of -20 ±2.5, -10.2 ± 6.5, -10.7 ± 1.3,and -1.2 ± 3.2‰ respectively. A grossite-hibonite-bearing inclusion also records O-isotopic heterogeneity, where grossite, hibonite, Mg-rich spinel, and melilite show -3.7 ± 2.7, -22.9 ± 2.5, -21.4 ± 2.6, and -17.3 ± 2.8‰ respectively, whereas perovskite grains record a heterogenous isotopic composition ranging from -22.6 to -13.9‰. A hibonite-bearing inclusion shows average Δ17Ο values of -17.6 ± 5.3 ‰ and -15.1 ± 4.8 ‰ for hibonite and spinel respectively. The two perovskite grains also show relatively 16O-poor composition (Δ17Ο = -11.8 ± 6.4 ‰ and -8.6 ± 5.2 ‰). Anorthite has ~0.1 wt% Na2O and ~0.52 wt% FeO and a Δ17Ο value of -7.2 ± 5.0 ‰, whereas diopside records a Δ17Ο value of -3.5 ± 5.0 ‰. A hibonite-spinel-rich inclusion contains spinel and hibonite that are16O-rich (Δ17Οvalues -21.3 ± 2.8‰ and -19.4 ± 3.0‰, respectively). Melilite shows heterogenous oxygen isotopic composition, with an inner 16O-rich region and an outer 16O-poor region separated by a sharp boundary, with a bulk Δ17Ο= -16.2 ± 2.1‰, whereas two perovskite grains are relatively 16O-poor (Δ17Ο= -13.2 ± 3.7‰ and -7.1 ± 3.4‰).A spinel-rich inclusion contains perovskite grains with Δ17Οranging from -27.0 to -22.8 ‰and spinel with average Δ17Οvalue of -21.4 ± 2.8 ‰. In a melilite and spinel-rich CAI, perovskite, spinel, diopside, melilite, and Al-Ti-rich pyroxene record Δ17Ο values of-26.9 ± 4.6‰, -22.4 ± 4.3‰,-23.4 ± 4.9, -19.3 ± 3.4, and -19.0 ± 4.3 ‰ respectively. Olivine and spinel components of 2 AOA’s record a 16O-rich composition with Δ17O~-23‰. Discussion: The coexistence of 16O-rich and 16O-poor minerals within CAIs has been attributed to differing degrees of O isotopic exchange, reflecting a wide range of O diffusion rates[5]. However, the O isotopic heterogeneity observed in these CAIs cannot be explained by oxygen diffusion in nebular or parent body settings alone. The isotopic imaging of CAIs from the MIL 090019 meteorite shows variations in the O isotopic composition recorded in their mineral components, suggesting that these CAIs record the oxygen isotopic heterogeneity in the nebular gas from which they condensed. The coexistence of 16O-rich and 16O-poor mineral components in the CAI-forming region suggests that the gas in this region was not well-mixed and consisted of distinct 16O-rich and 16O-poor gaseous reservoirs.

P Mane

High resolution infrared spectroscopy: Some new approaches and applications to planetary atmospheres

The principles of spectral line formation and of techniques for retrieval of atmospheric temperature and constituent profiles are discussed. Applications to the atmospheres of Earth, Mars, Venus, and Jupiter are illustrated by results obtained with Fourier transform and infrared heterodyne spectrometers at resolving powers (lambda/delta hyperon lambda of approximately 10,000 and approximately 10 to the seventh power), respectively, showing the high complementarity of spectroscopy at these two widely different resolving powers. The principles of heterodyne spectroscopy are presented and its applications to atmospheric probing and to laboratory spectroscopy are discussed. Direct absorption spectroscopy with tuneable semiconductor lasers is discussed in terms of precision frequency-and line strength-measurements, showing substantial advances in laboratory infrared spectroscopy.

Mumma, M. J.

Spectroscopic equipment for the Space Telescope

The Space Telescope will provide views of the Universe of remarkable clarity. Central to its capabilities is an f/24 Ritchey-Chretien telescope with 40,000 sq cm unobscured collecting area, which will provide point-source images less than 0.1 sec in radius at wavelengths below 633 nm. It will operate over the range 110 nm to 1 mm. The initial flight instrumentation includes two spectrographs, the Faint Object Spectrograph (F.O.S.) and the High-Resolution Spectrograph (H.R.S.). The F.O.S. is sensitive from 115 to 800 nm. It will provide data at resolving powers 1000-100 on extremely faint sources. The H.R.S. operates at the wavelengths 107-320 nm. It will achieve high photometric accuracy at resolving powers 100,000, in the echelle mode, or 10,000-1000 in first order, on brighter targets. The two cameras on board the Space Telescope will provide ancillary spectroscopic capabilities.

Leckrone, D. S.

AIRES: An Airborne Infra-Red Echelle Spectrometer for SOFIA

SOFIA will enable astronomical observations with unprecedented angular resolution at infrared wavelengths obscured from the ground. To help open this new chapter in the exploration of the infrared universe, we are building AIRES, an Airborne Infra-Red Echelle Spectrometer. AIRES will be operated as a first generation, general purpose facility instrument by USRA, NASA's prime contractor for SOFIA. AIRES is a long slit spectrograph operating from 17 - 210 microns. In high resolution mode the spectral resolving power is approx. 10(exp 6) microns/A or approx. 10(exp 4) at 100 microns. Unfortunately, since the conference, a low resolution mode with resolving power about 100 times lower has been deleted due to budgetary constraints. AIRES includes a slit viewing camera which operates in broad bands at 18 and 25 microns.

Dotson, Jessie J.

A diffuse soft X-ray spectrometer

A design for a diffuse X-ray spectrometer utilizing Bragg reflection is described. The geometry has a very high throughput for a given physical size and allows simultaneous observation at all wavelengths within its range. Spectral resolving power is about 35 to 50. A similar unit equipped with thallium acid pthallate crystals will cover the 11 - 24 A-range with about half this throughput and twice the resolving power.

Mccammon, D.

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783

Infrared Space Observatory Observations of Far-Infrared Rotational Emission Lines of Water Vapor Toward the Supergiant Star VY Canis Majoris

We report the detection of numerous far-infrared emission lines of water vapor toward the supergiant star VY Canis Majoris. A 29.5-45 micron grating scan of VY CMa, obtained using the Short-Wavelength Spectrometer (SWS) of the Infrared Space Observatory at a spectral resolving power lambda/delat.lambda of approximately 2000, reveals at least 41 spectral features due to water vapor that together radiate a total luminosity of approximately 25 solar luminosity . In addition to pure rotational transitions within the ground vibrational state, these features include rotational transitions within the (010) excited vibrational state. The spectrum also shows the (sup 2)product(sub 1/2) (J = 5/2) left arrow (sup 2)product(sub 3/2) (J = 3/2) OH feature near 34.6 micron in absorption. Additional SWS observations of VY CMa were carried out in the instrument's Fabry-Perot mode for three water transitions: the 7(sub 25)-6(sub 16) line at 29.8367 micron, the 4(sub 41)-3(sub 12) line at 31.7721 micron, and the 4(sub 32)-3(sub 03) line at 40.6909 micron. The higher spectral resolving power lambda/delta.lambda of approximately 30,000 thereby obtained permits the line profiles to be resolved spectrally for the first time and reveals the "P Cygni" profiles that are characteristic of emission from an outflowing envelope.

Neufeld, David A.

Thermal infrared observations of Mars (7.5-12.8 microns) during the 1990 opposition

Thirteen spectra of Mars, in the 7.5 to 12.8 micron wavelength were obtained on 7 Dec. 1990 from the Infrared Telescope Facility (IRTF). For these observations, a grating with an ultimate resolving power of 120 to 250 was used and wavelengths were calibrated for each grating setting by comparison with the absorption spectrum of polystyrene measured prior to each set of observations. By sampling the Nyquist limit at the shortest wavelengths, an effective resolving power of about 120 over the entire wavelength range was achieved. A total of four grating settings were required to cover the entire wavelength region. A typical observing sequence consisted of: (1) positioning the grating in one of the intervals; (2) calibrating the wavelength of positions; and (3) obtaining spectra for a number of spots on Mars. Several observations of the nearby stellar standard star, alpha Tauri, were also acquired throughout the night. Each Mars spectrum represents an average of 4 to 6 measurements of the individual Mars spots. As a result of this observing sequence, the viewing geometry for a given location or spot on Mars does not change, but the actual location of the spot on Mars's surface varies somewhat between the different grating settings. Other aspects of the study are presented.

Roush, T. L.

Grism Performance for Mid-IR (5-40 microns) Spectroscopy

Grisms provide a straightforward method to transform an imager into a spectrometer with little change to the original imaging optics. This paper addresses the performance of a suite of grisms as part of an Astrobiology Science and Instrument Development (ASTID) Program to implement a moderate resolution spectroscopic capability to the mid/far-IR facility instrument FORCAST for the Stratospheric Observatory For Infrared Astronomy (SOFIA) [see accompanying abstract by Adams et al.]. A moderate resolution mid-IR spectrometer on SOFIA will offer advantages not available to either ground or space-based instruments after the Spitzer Space Telescope ceases operation in approx. 2007. SOFIA will begin operations in 2007 and will have an operational lifetime of approx. 20 years. From aircraft altitudes, it will be possible to cover a range of wavelengths, particularly in the critical 5-9 micron band, where detection of astrobiologically interesting molecules have key spectral signatures, that are not accessible from the ground. This grism suite consists of six grisms: four monolithic Si grisms [see accompanying abstract by Mar et al.] and two KRS-5 grisms. These devices will allow long slit low-resolution and short slit, cross-dispersed high-resolution spectroscopic modes selectable by simply moving the camera filter wheels. This configuration will enable observing programs to gather images and spectra in a single SOFIA flight. The four silicon grisms, whose performance is highlighted in this paper, will operate in the following wavelength ranges: 5-8, 17-28, and 28-37 microns. In the 5-8 micron range, R=1200 is achievable for a 2 arcsecond slit using the grism as a cross-disperser. For the 17-28 and 28-37 micron ranges, the resolving powers are R approx. 130, 250 when used in low orders with a slit of 3 arcseconds. The silicon grisms demonstrate a new family of dispersive elements with good optical performance for spectroscopy from 1.2-8 micron and beyond 18 microns. Furthermore, the FORCAST grism modes are close in wavelength coverage and resolving power to the Spitzer Infrared Spectrograph (IRS), so that among other possible observations, SOFIA can now enable follow-up studies of the brighter objects that Spitzer has observed and enable studies of sources that were too bright for observation with Spitzer.

Ennico, K. A.

Khayyam; Progress and Prospects of Coupling a Spatial Heterodyne Spectrometer (SHS) to a Cassegrain Telescope for Optical Interferometry

In the temporal study of faint, extended sources at high resolving power, Spatial Heterodyne Spectrometer (SHS) can offer significant advantages about conventional dispersive grating spectrometers. We describe here a four-year continuous progress in Mt. Hamilton, Lick Observatory, toward development of a prototype reflective Spacial Heterodyne Spectrometer, Khayyam, instrument-telescope configuration to combine all of the capabilities necessary to obtain high resolving power visible band spectra of diffuse targets from small aperture on-axis telescopes where significant observing time can be obtained. We will discuss the design considerations going into this new system, installation, testing of the interferometer-telescope combination, the technical challenges and procedures moving forward.

extended targets

Resolution of annealing experiments for the study of nonequilibrium states

The two techniques for conducting annealing experiments for the purpose of determining the distribution of atoms of a solid among non equilibrium states are considered. Related definitions for resolving power for annealing with steadily rising temperature and for annealing at a series of fixed temperatures are given. The necessary separation of activation energies for the resolution of two different non equilibrium states is found to be greater in the case of a steadily rising temperature, but of the order of 10 percent of the activation energy for both techniques. The resolving power in the case of a steadily rising temperature is independent of the rate of temperature rise.

SOLIDS

High-resolution spectra and photoabsorption coefficients for carbon monoxide absorption bands between 94.0 nm and 100.4 nm

Photoabsorption coefficients have been measured for the CO in interstellar clouds at a resolving power more than 20 times greater than previously obtainable. In order to facilitate comparisons, these data have been integrated over the same wavelength ranges as used in Letzelter et al. (1987). It is found that most of the results obtained for bands between 94.0 and 100.4 nm are larger than those of Letzelter; the discrepancy may be attributable to the difference between the resolving powers of the spectrometers used, because the saturation effects associated with low resolution can underestimate absorption coefficient values.

Yoshino, K.