Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radioxenon detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying the Potential of Argon Detection Capabilities for Nuclear Explosion Monitoring

Abstract Current noble gas detection systems for nuclear explosion monitoring are based on the detection of four radioxenon isotopes—Xe-131m, -133, -133m and -135. The data provided by radioxenon detection could be enhanced by other radionuclide signatures such as Ar-37. Activation of Ca-40 in rock by neutrons produces Ar-37, and monitoring for this additional nuclide could help distinguish detections of nuclear explosions from background sources, such as medical isotope production. This work studies the capabilities of a hypothetical argon detection network. A 10 kt explosion was modeled using MCNP and SCALE to determine the inventory of Ar-37 created in a representative granite rock layer, assuming either 0.1, 1 or 10% of the total inventory was released. The Ar-37 inventory was combined with atmospheric transport data from HYSPLIT compiled in a previous study, along with the detection limits of standard Ar-37 detection systems, to determine how many hypothetical monitoring stations would detect Ar-37 from an explosion. This method was repeated for 365 HYSPLIT data sets to create a year’s worth of hypothetical explosions, releases, and detections. The study quantified the average number of detections per release, the number of stations detecting Ar-37, and the possibility of detecting Ar-37 in coincidence with xenon.

37Ar↗

A prototype detection system for atmospheric monitoring of xenon radioisotopes

The design of a radioxenon detection system utilizing a CdZeTe crystal and a plastic scintillator coupled to an array of SiPMs to conduct beta-gamma coincidence detection for atmospheric radioxenon monitoring, as well as the measurement of 135 Xe and 133/133m Xe, have been detailed previously. This paper presents recent measurements of 133/133m Xe and 131m Xe and the observation of conversion electrons in their coincidence spectra, as well as a 48-hour background measurement to calculate the Minimum Detectable Concentration (MDC) of radioxenon isotopes in the system. The identification of Regions of Interest (ROIs) in the coincidence spectra yielded from the radioxenon measurements, and the subsequent calculation of the MDCs of the system for 135 Xe, 133/133m Xe, and 131m Xe, are also discussed. Calculated MDCs show that the detection system preforms respectably when compared to other state of the art radioxenon detection systems and achieved an MDC of less than 1 mBq/m 3 for 131m Xe, 133 Xe, and 133m Xe, in accordance with limits set by the Comprehensive Nuclear-Test-Ban Treaty (CTBTO). Lastly, the system also provides the advantage of room temperature operation, compactness, low noise operation and having simple readout electronics.

36 MATERIALS SCIENCE↗

The 2014 Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty revisited: The case for data fusion

The International Monitoring System of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) uses a global network of radionuclide monitoring stations to detect evidence of a nuclear explosion. The two radionuclide technologies employed—particulate and noble gas (radioxenon) detection—have applications for data fusion to improve detection of a nuclear explosion. Using the hypothetical 0.5 kT nuclear explosive test scenario of the CTBTO 2014 Integrated Field Exercise, the intrinsic relationship between particulate and noble gas signatures has been examined. Here this study shows that, depending upon the time of the radioxenon release, the particulate progeny can produce the more detectable signature. Thus, as both particulate and noble gas signatures are inherently coupled, the authors recommend that the sample categorization schemes should be linked.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Neural Network Based State of Health Diagnostics for an Automated Radioxenon Sampler/Analyzer

Artificial neural networks (ANNs) are used to determine the state-of-health (SOH) of the Automated Radioxenon Analyzer/Sampler (ARSA). ARSA is a gas collection and analysis system used for non-proliferation monitoring in detecting radioxenon released during nuclear tests. SOH diagnostics are important for automated, unmanned sensing systems so that remote detection and identification of problems can be made without onsite staff. Both recurrent and feed-forward ANNs are presented. The recurrent ANN is trained to predict sensor values based on current valve states, which control air flow, so that with only valve states the normal SOH sensor values can be predicted. Deviation between modeled value and actual is an indication of a potential problem. The feed-forward ANN acts as a nonlinear version of principal components analysis (PCA) and is trained to replicate the normal SOH sensor values. Because of ARSA’s complexity, this nonlinear PCA is better able to capture the relationships among the sensors than standard linear PCA and is applicable to both sensor validation and recognizing off-normal operating conditions. Both models provide valuable information to detect impending malfunctions before they occur to avoid unscheduled shutdown. Finally, the ability of ANN methods to predict the system state is presented.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Real-time Stack Monitoring at the BaTek Medical Isotope Production Facility

Radioxenon emissions from radiopharmaceutical production are a major source of background concentrations affecting the radioxenon detection systems of the International Monitoring System (IMS). Collection of real-time emissions data from production facilities makes it possible to screen out some medical isotope signatures from the IMS radioxenon data sets. This paper describes an effort to obtain and analyze real-time stack emissions data with the design, construction and installation of a small stack monitoring system developed by a joint CTBTO-IDC, BATAN, and PNNL team at the BaTek medical isotope production facility near Jakarta, Indonesia.

CTBTO↗

Absolute Efficiency Calibration of a Beta-Gamma Detector

Abstract- Identification and quantification of nuclear events such as the Fukushima reactor failure and nuclear explosions rely heavily on the accurate measurement of radioxenon releases. One radioxenon detection method depends on detecting beta-gamma coincident events paired with a stable xenon measurement to determine the concentration of a plume. Like all measurements, the beta-gamma method relies on knowing the detection efficiency for each isotope measured. Several methods are commonly used to characterize the detection efficiency for a beta-gamma detector. The most common method is using a NIST certified sealed source to determine the efficiency. A second method determines the detection efficiencies relative to an already characterized detector. Finally, a potentially more accurate method is to use the expected sample to perform an absolute efficiency calibration; in the case of a beta-gamma detector, this relies on radioxenon gas samples. The complication of the first method is it focuses only on the gamma detectors and does not offer a solution for determining the beta efficiency. The second method listed is not similarly constrained, however it relies on another detector to have a well-known efficiency calibration. The final method using actual radioxenon samples to make an absolute efficiency determination is the most desirable, but until recently it was not possible to produce all four isotopically pure radioxenon. The production, by University of Texas (UT), of isotopically pure radioxenon has allowed the beta-gamma detectors to be calibrated using the absolute efficiency method. The first four radioxenon isotope calibration will be discussed is this paper.

absolute efficiency calibration beta-gamma↗

First Four-Isotope Calibration of a Beta-Gamma Quad Detector

Beta-gamma coincidence detectors used for radioxenon detection are non-standard detector types, but still require energy and efficiency calibration. There are several methods that are commonly used to perform a detector calibration. ? NIST certified sealed source ? Relative measurement to compare to a calibrated detector ? Absolute efficiency calibration based on radioxenon gas samples. The method using actual radioxenon samples to make an absolute efficiency determination is the most desirable, but until recently it was not possible to produce all four isotopically pure radioxenon. The first four radioxenon isotope calibration is outlined here.

Cooper, Matthew W.↗

Activation of enriched environmental xenon by 14-MeV neutrons

The international monitoring system exists to verify compliance with the terms of the comprehensive test ban treaty. About 10% of the member stations will be capable of detecting radioxenon, which can be produced in nuclear detonations or through civilian processes. We have studied the activation of radioxenon by the prompt, intense spectrum of 14-MeV neutrons produced at the National Ignition Facility. While 14-MeV neutrons are not currently a significant contributor to the production of radioxenon, we find that radioxenon produced through activation of environmental xenon by 14-MeV neutrons would be distinguishable from activation by nuclear tests.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Conceptual Silicon Beta Cell Design

Silicon detectors have the potential to significantly improve the sensitivity limits for radioxenon detection. While silicon has beneficial attributes like improved energy resolution and memory effect, the sensitivity improvements will not occur without a properly designed beta cell that utilizes silicon detectors. This report details the key parameters that have been incorporated into the design of a silicon beta cell. Parameters that have the potential to change as a prototype silicon beta cell is developed and during the future commercialization process are also discussed. The design of the silicon beta cell has focused primarily on simulations and analytical models to optimize the mechanical properties. Additionally, a team of experts provided guidance and potential alternatives for the silicon detectors and electronics fabrication. A conceptual design for a silicon beta cell was completed, with an emphasis on the modularity of the system. The modularity allows for any potential changes that may be of interest during the prototyping phase or future spiral development to be implemented with minimal impact on the complete system. The impact of the silicon based beta cell is discussed in the conclusions, along with potential next steps. Mechanical design drawings for the beta cell could be used to manufacture a prototype beta cell and are available in an appendix document.

36 MATERIALS SCIENCE↗

Efficient, Portable Radioxenon Collection for Nuclear Test Monitoring

Detection of radioxenon in the atmosphere is considered the most specific method to determine whether a nuclear test has occurred. It is therefore an important component of the Comprehensive Test Ban Treaty (CTBT) verification regime. Radioxenon collection is primarily performed by means of a network of remote monitoring stations at fixed locations around the world. This arrangement is effective but often limited in terms of the response time and sensitivity, two factors that could be improved if radioxenon collection devices were portable. By employing recent advancements in porous materials and adsorption technologies, it is possible to overcome some of the limitations of current radioxenon collection systems. This work established the initial modeling and scoping study towards developing an efficient and portable radioxenon collection system for nuclear test monitoring.

36 MATERIALS SCIENCE↗

Incorporating civilian radioxenon background estimates in anomaly detection

A nuclear explosion screening exercise in 2023 (Maurer et al., 2023) found challenges with discerning anomalous radioxenon activity concentrations relative to elevated background concentrations. Research has continued into methods to detect anomalous radioxenon concentrations by comparing samples to estimates of atmospheric radioxenon background concentrations caused by releases at nuclear reactors or medical isotope production facilities. A new approach estimates the sample concentrations using time-varying radioxenon release rates obtained using optimization techniques that constrain the facility release rates to plausible amounts based on historical data or facility knowledge. The purpose of the optimization is to determine whether any combination of plausible release rates from emitting facilities can explain a series of radioxenon measurements at one or more sampling stations. A case study uses radioxenon data collected at three locations in western Europe for a month in 2021 and considers releases from 77 locations. Fewer samples are identified as being anomalous using a simplistic flagging rule than from an application of the current International Monitoring System (IMS) activity concentration-level rule.

Environmental sciences↗

Noble Gas Surface Flux Simulations And Atmospheric Transport

Signatures from underground nuclear explosions or UNEs are strongly influenced by the containment regime surrounding them. The degree of gas leakage from the detonation cavity to the surface obviously affects the magnitude of surface fluxes of radioxenon that might be detected during the course of a Comprehensive Test Ban Treaty On-Site Inspection. In turn, the magnitude of surface fluxes will influence the downwind detectability of the radioxenon atmospheric signature from the event. Less obvious is the influence that leakage rates have on the evolution of radioxenon isotopes in the cavity or the downwind radioisotopic measurements that might be made. The objective of this letter report is to summarize our attempt to better understand how containment conditions affect both the detection and interpretation of radioxenon signatures obtained from sampling at the ground surface near an event as well as at greater distances in the atmosphere. In the discussion that follows, we make no attempt to consider other sources of radioactive noble gases such as natural backgrounds or atmospheric contamination and, for simplicity, only focus on detonation-produced radioxenon gases. Summarizing our simulations, they show that the decay of radioxenon isotopes (e.g., Xe-133, Xe-131m, Xe-133m and Xe-135) and their migration to the surface following a UNE means that the possibility of detecting these gases exists within a window of opportunity. In some cases, seeps or venting of detonation gases may allow significant quantities to reach the surface and be released into the atmosphere immediately following a UNE. In other release scenarios – the ones we consider here – hours to days may be required for gases to reach the surface at detectable levels. These release models are most likely more characteristic of “fully contained” events that lack prompt venting, but which still leak gas slowly across the surface for periods of months.

58 GEOSCIENCES↗

135 Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring

Measurement of elevated concentrations of xenon radioisotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for verifying whether or not a detected explosion is nuclear in nature. These isotopes are among the few with enough mobility and with half-lives long enough to make their detection at long distances realistic. Existing radioxenon detection systems used by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) suffer from problems such as complexity, need for high maintenance and memory effect. To study the response of CdZnTe (CZT) detectors to xenon radioisotopes and investigate whether it is capable of mitigating the afore-mentioned issues with the current radioxenon detection systems, a prototype detector utilizing two coplanar CZT detectors was built and tested at Oregon State University. The detection system measures xenon radioisotopes through beta-gamma coincidence technique by detecting coincidence events be-tween the two detectors. Here in this paper, we introduce the detector design and report our measurement results with radioactive lab sources and 135 Xe produced in the OSU TRIGA reactor. Minimum Detectable Concentration (MDC) for 135 Xe was calculated to be 1.47 ± 0.05 mBq/m 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

Study of Shadowing in Beta-Gamma Coincidence Plots for Radioxenon

This document describes a study of the cause of shadowing observed in certain beta-gamma plots produced with beta-gamma coincidence detectors for detection of radioxenon. Beta-gamma detectors must possess adequate resolution to allow for the metastable isotopes 131m Xe and 133m Xe to be distinguished from each other and from 133 Xe. One effect that can minimize the ability to distinguish the metastables from 133 Xe is the shadowing effect, in which a band of high-energy signal is present in addition to the primary signal. A study was performed to determine the cause of the shadowing, and how to minimize the effect of the shadowing on an individual beta cell. Through this study, it is determined that the shadowing results from a difference in light transmission between the dome and end-cap portions of the beta cell. Consequently, it is not possible to remove the shadowing during the beta cell manufacturing process. The shadowing must be minimized by preferentially matching the light output from the end-cap and dome portion prior to the manufacturing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection in subsurface air of radioxenon released from medical isotope production

Abstract Under the Comprehensive Nuclear-Test-Ban Treaty, an On-Site Inspection (OSI) may be conducted to clarify whether a nuclear explosion has been carried out in violation of Article I of the Treaty. A major component of an OSI is the measurement of subsurface gases in order to detect radioactive noble gases that are produced in a nuclear explosion, particularly radioxenon and radioargon. In order to better understand potential backgrounds of these gases, a sampling campaign was performed near Canadian Nuclear Laboratories in the Ottawa River Valley, a major source of environmental radioxenon. First of their kind measurements of atmospheric radioxenon imprinted into the shallow subsurface from an atmospheric pressure driven force were made using current OSI techniques to measure both atmospheric and subsurface gas samples which were analyzed for radioxenon. These measurements indicate that under specific sampling conditions, on the order of one percent of the atmospheric radioxenon concentration may be measured via subsurface sampling.

07 ISOTOPE AND RADIATION SOURCES↗