At least 37 records · Page 2

Coordinated voltage control and reactive power regulation between transmission and distribution systems

Systems and methods are described for coordinating volt-var control between sub-transmission and distribution systems. Distributed energy resources of a distribution system are aggregated into virtual power plants from which reactive power can optimally be dispatched to the sub-transmission system. A sub-transmission controller executes a volt-var AC optimal power flow optimisation function to minimize voltage fluctuations that might otherwise occur when coordinating with a distribution system having distributed energy resources. The distribution system can use a sensitivity matrix for regulating voltage at distribution feeders while fulfilling a transmission or sub-transmission system's demand requests.

Samaan, Nader A.↗

System and method for engine control with pressure reactive device to control combustion timing

The present disclosure relates to a system for controlling ignition of an intake charge directed into an internal combustion engine. The system may have a movable component operably associated with at least one of a piston of the engine or a combustion chamber of the engine. The movable component may be tuned to deflect in response to a predetermined pressure being reached in a cylinder in which the piston is housed. The movable component operates to deflect in response to the predetermined pressure being reached in the cylinder as the piston travels toward top dead center during its compression stroke, to change a compression ratio of the engine.

Killingsworth, Nicholas↗

A Deep Learning Modeling Framework to Capture Mixing Patterns in Reactive-Transport Systems

Prediction and control of chemical mixing are vital for many scientific areas such as subsurface reactive transport, climate modeling, combustion, epidemiology, and pharmacology. Due to the complex nature of mixing in heterogeneous and anisotropic media, the mathematical models related to this phenomenon are not analytically tractable. Numerical simulations often provide a viable route to predict chemical mixing accurately. However, contemporary modeling approaches for mixing cannot utilize available spatial-temporal data to improve the accuracy of the future prediction and can be compute-intensive, especially when the spatial domain is large and for long-term temporal predictions. To address this knowledge gap, in this work we will present in this paper a deep learning (DL) modeling framework applied to predict the progress of chemical mixing under fast bimolecular reactions. This framework uses convolutional neural networks (CNN) for capturing spatial patterns and long short-term memory (LSTM) networks for forecasting temporal variations in mixing. By careful design of the framework—placement of non-negative constraint on the weights of the CNN and the selection of activation function, the framework ensures non-negativity of the chemical species at all spatial points and for all times. Our DL-based framework is fast, accurate, and requires minimal data for training. The time needed to obtain a forecast using the model is a fraction (≈ O(-6)) of the time needed to obtain the result using a high-fidelity simulation. To achieve an error of 10% (measured using the infinity norm) for capturing local-scale mixing features such as interfacial mixing, only 24% to 32% of the sequence data for model training is required. To achieve the same level of accuracy for capturing global-scale mixing features, the sequence data required for model training is 64% to 70% of the total spatial-temporal data. Hence, the proposed approach—a fast and accurate way to forecast long-time spatial-temporal mixing patterns in heterogeneous and anisotropic media—will be a valuable tool for modeling reactive-transport in a wide range of applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Fidelity Measurements for Flattop-HEU Benchmark Reevaluation

Flattop was first built in the 1950’s at Los Alamos National Laboratory. Flattop-HEU is composed of a sphere of highly enriched uranium (HEU) surrounded by a thick spherical natural uranium (NU) reflector. The reflector is composed of three parts: a stationary hemisphere and two movable quarter spheres. For fine control of the reactivity of the system, there are three control rods of natural uranium located in voids in the stationary hemisphere. The final components that make Flattop a useful critical assembly are the glory hole and mass adjustment pieces. These pieces can be loaded in various configurations into the glory hole and the core pedestal to control the known worth of the system. The glory hole and mass adjustment pieces are mostly small pieces of HEU with some mass adjustment pieces fabricated from NU. This allows for the irradiation of samples to a specified level. To better document the system, Flattop was evaluated and included in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook. The original benchmark evaluation of Flattop-HEU was written in 1999 based on an experiment completed in the 1960’s. This original evaluation was written to provide a single diameter that defined critical mass; however, as computational capabilities have increased, the focus for benchmark evaluations has shifted to include detailed modelswith all physical dimensions. Thus, as Flattop is a lynchpin in critical experiment work, the benchmark is being reevaluated at current standards. This summary discusses some of the largest known uncertainties from the evaluation and the high-fidelity measurements taken to reduce these uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a FHR

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to include non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR technologies under Strategy 2 of the NRC's near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enhancements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform fluoride-salt-cooled high-temperature reactor (FHR) safety evaluations. The generic plant model is based on publicly-available FHR design information. For plant aspects (e.g., reactor building leak rate and details of the cover-gas system) that are not described in the FHR references, the analysts made assumptions needed to construct a MELCOR full-plant model. The FHR model uses a TRi-structural ISOtropic (TRISO)-particle fuel pebble-bed reactor with a primary system rejecting heat to two coiled tube air heat ex changers. Three passive direct reactor auxiliary cooling systems provide heat removal to supplement or replace the emergency secondary system heat removal during accident conditions. Surrounding the reactor vessel is a low volume reactor cavity that insulates the reactor with fire bricks and thick concrete walls. A refractory reactor liner system provides water cooling to reduce the concrete wall temperatures. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing reactivity control, the primary system decay heat removal and also a piping leak of the line to the coolant drain tank.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

TEX-HEU: Integral Experiments with Highly Enriched Uranium and Polyethylene (IER-297 CED-3b Report)

This report documents the experimental critical configurations and measurements for IER-297, Thermal/Epithermal eXperiments (TEX) using highly enriched uranium (HEU) fuel, moderated and reflected by polyethylene. These experiments establish the baseline TEX-HEU configurations spanning thermal, intermediate, and fast fission energy regimes. The experiment campaign was completed in FY2020 at the National Critical Experiments Research Center at the Nevada National Security Site. The campaign produced six documented critical configurations (0”, ¹/₈” A, ¹/₈” B, ¹/₄”, ¹/₂”, and 1¹/₂”) and one reproducibility measurement (¹/₈” R). Table 1 summarizes these seven experiments along with their period and calculated reactivity, in order of execution. The Comet General Purpose Critical Assembly Machine was used to conduct the TEX-HEU experiments. The HEU fuel consists of U(93+) plates, collectively known as the “Jemima” plates. Each experiment consisted of an alternating stack of these HEU plates with or without polyethylene moderator plates. By varying the thicknesses of the polyethylene plates, the neutron spectrum of the experiment could be fine-tuned to a specific fission energy regime. The experiments were reflected by 1” of polyethylene consisting of a bottom and top plate and outer reflector rings to surround the HEU and polyethylene plates. The fine reactivity control of the system was provided by the thickness of the top reflector plate, which could be varied in increments of ¹/₃₂”.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational design of microarchitected porous electrodes for redox flow batteries

Porous electrodes are used as the core reactive component across electrochemical technologies. In flowing systems, controlling the fluid distribution, species transport, and reactive environment is critical to attaining high performance. However, conventional electrode materials like felts and papers provide few opportunities for precise engineering of the electrode and its microstructure. To address these limitations, architected electrodes composed of unit cells with spatially varying geometry determined via computational optimization are proposed. Resolved simulation is employed to develop a homogenized description of the constituent unit cells. These effective properties serve as inputs to a continuum model for the electrode when used in the negative half-cell of a vanadium redox flow battery. Porosity distributions minimizing power loss are then determined via computational design optimization to generate architected porosity electrodes. The architected electrodes are compared to bulk, uniform porosity electrodes and found to lead to increased power efficiency across operating flow rates and currents. The design methodology is further used to generate a scaled-up electrode with comparable power efficiency to the bench-scale systems. Finally, the variable porosity architecture and computational design methodology presented here thus offers a novel pathway for automatically generating spatially engineered electrode structures with improved power performance.

25 ENERGY STORAGE↗

Nontraditional Catalyst Supports in Surface Organometallic Chemistry

The field of Surface Organometallic Chemistry (SOMC) aims to blend the positive attributes of homogeneous and heterogeneous catalysis. Significant insight into heterogeneous systems has been gained over the years through the synthesis, characterization, and application of well-defined surface organometallic catalysts, predominantly supported on silica and alumina. Considerable research efforts have focused on the application of homogeneous methods to the synthesis and characterization of these systems. Homogeneous catalysis has thrived on its ability to electronically and sterically tune ligands to yield desired reactivity and selectivity. Efforts in SOMC, however, have only recently turned to harnessing the stereoelectronic diversity of potential inorganic support materials beyond silica and alumina in order to exert similar control on the reactivity of the organometallic active site. The support material is intrinsically linked to electronic structure and reactivity of heterogeneous organometallic systems in the same way that ligands exert control over homogeneous catalyst systems. The ability to tune the reactivity of heterogeneous catalysts by changing the support is of great value, and it is anticipated that this will represent an area of significant growth in the field. In this Perspective, the use and future of nontraditional catalyst supports, such as sulfated metal oxides, modified silicas, and redox active supports are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

grid-following inverter↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This presentation discusses the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

droop control↗

Review of Power System Support Functions for Inverter-Based Distributed Energy Resources - Standards, Control Algorithms, and Trends

Penetration of renewable energy in power systems has been increasing in the past decades in response to increased global electricity demand and concerns for the environment. Distributed energy resources (DERs) based on renewables have experienced rapid growth thanks to the incentive programs and broad-based participation. With the growing prevalence of DERs, the risk of grid instability and vulnerability increases due to the intermittent nature of renewable energy. At the same time, the voltage and frequency deviation problems emerge more often when the reverse power flow occurs under supply-demand imbalance in distributed power systems. Standards and grid codes have been issued for DER inverters to interconnect with the distribution grid. The updated standard and grid codes expect DERs to provide a variety of power system support functions in order to incorporate higher DER penetration and to maximize DER value to the grid. This paper provides an overview of the power system support functions from renewable DER inverters, which are categorized as: voltage regulation by active/reactive power control, frequency regulation by active power control, voltage ride-through, and frequency ride-through. The benefits and drawbacks of each algorithm are presented and compared with its predecessor, manifesting the logic in the evolution of the algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗