Search NASA⌕ Search

SEARCH · Search NASA

Results for “Residual Gas Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Developing Mass Spectrometry for Water Quantitation and Volatiles Analysis from In-Situ Regolith

With a revived focus to create a sustainable hu-man presence on the moon, and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential [1]. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable in-dependent operation of missions while reducing the dependence on the complex supply chain created between the Earth, the moon and Mars. One of the most critical resources that has been identified for ISRU on the lunar surface is water [2]. Water is a versatile resource that can be used in various space operations, such as ra-diation shielding and conversion to oxygen (O2) for propellant [3,4]. One of the most water rich resources is thought to be within the regolith lo-cated in the permanently shadowed regions (PSR) of the Moon; several upcoming missions, such as PRIME-1 and VIPER, are already sched-uled to confirm this hypothesis [5,6]. However, there are currently no missions planned to quanti-fy the abudance of water at these regions. The quantity of water contained in the ice will inform and help the development of future ISRU plants and operation. Water and other volatile gases can be detect-ed upon controlled heating of icy lunar regolith for an accurate quantification of water. This method is similar to thermogravimetric analysis, which was used to analyze Apollo lunar regolith sam-ples. However, losses via sublimation/evaporation or contamination may have occurred with the samples due to the transit and exposure to the terrestrial environment. Furthermore, water would not be expected for these samples since they were not collected from a PSR. Thus, for more accurate results, icy lunar regolith should be ana-lyzed in situ to provide the most representative composition of both water and other volatile gas-es. The Light Water Analysis and Volatile Extract (LightWAVE) project aims to address this knowledge gap. A system has been developed to collect, heat and analyze evolved gases from lu-nar regolith on the lunar surface. The gases will be analyzed by a modified commercial off the shelf (COTS) residual gas analyzer (RGA) quad-rupole mass spectrometer. Evolved gases from heated regolith samples can be identified by the observed mass-to-charge (m/z) ratios, and the peak intensities correlate to the abundances of the observed gases for quantitation. Therefore, our group is developing a calibration methodology utilizing a COTS RGA to quantitate water from in-situ regolith samples on the lunar surface. The partial pressure of water and ideal gas law will be used to quantify the total water evolved from a regolith sample. Here we present our methodol-ogy for the design and calibration for water quan-titation using a COTS RGA.

Nilab Azim↗

Polycrystalline silicon on tungsten substrates

Thin films of electron-beam-vaporized silicon were deposited on fine-grained tungsten substrates under a pressure of about 1 x 10 to the -10th torr. Mass spectra from a quadrupole residual-gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. During separate silicon depositions, the atomically clean substrates were maintained at various temperatures between 400 and 780 C, and deposition rates were between 20 and 630 A min. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry before and after cleaning, deposition, and annealing. Auger depth profiling, X-ray analysis, and SEM in the topographic and channeling modes were utilized to characterize the samples with respect to silicon-metal interface, interdiffusion, silicide formation, and grain size of silicon. The onset of silicide formation was found to occur at approximately 625 C. Above this temperature tungsten silicides were formed at a rate faster than the silicon deposition. Fine-grain silicon films were obtained at lower temperatures.

Bevolo, A. J.↗

Efficient solar cells by space processing

Thin films of electron beam evaporated silicon were deposited on molybdenum, tantalum, tungsten and molybdenum disilicide under ultrahigh vacuum conditions. Mass spectra from a quadrapole residual gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry. The presence of phosphorus in the silicon was responsible for attaining elevated temperatures with silicide formations. Heteroepitaxial silicon growth was sensitive to the presence of oxygen during deposition, the rate and length of deposition as well as the substrate orientation.

Schmidt, F. A.↗

Discourse for slide presentation: An overview of chemical detection systems

A brief overview of some of the analytical techniques currently used in monitoring and analyzing permanent gases and selected volatile organic compound in air are presented. Some of the analytical considerations in developing a specific method are discussed. Four broad groups of hardware are discussed: compound class specific personal monitors, gas chromatographic systems, infrared spectroscopic systems, and mass spectrometric residual gas analyzer systems. Three types of detectors are also discussed: catalytic sensor based systems, photoionization detectors, and wet or dry chemical reagent systems. Under gas chromatograph based systems five detector systems used in combination with a GC are covered: thermal conductivity detectors, photoionization detectors, Fourier transform infrared spectrophotometric systems, quadrapole mass spectrometric systems, and a relatively recent development, a surface acoustic wave vapor detector.

Peters, Randy Alan↗

Solid Hydrogen Particles and Flow Rates Analyzed for Atomic Fuels

The experiments were conducted at Glenn's Small Multipurpose Research Facility (SMIRF, ref. 5). The experimental setup was placed in the facility's vacuum tank to prevent heat leaks and subsequent boiloff of the liquid helium. Supporting systems maintained the temperature and pressure of the liquid helium bath where the solid particles were created. Solid hydrogen particle formation was tested from February 23 to April 2, 2001. Millimeter-sized solid-hydrogen particles were formed in a Dewar of liquid helium as a prelude to creating atomic fuels and propellants for aerospace vehicles. Atomic fuels or propellants are created when atomic boron, carbon, or hydrogen is stored in solid hydrogen particles. The current testing characterized the solid hydrogen particles without the atomic species, as a first step to creating a feed system for the atomic fuels and propellants. This testing did not create atomic species, but only sought to understand the solid hydrogen particle formation and behavior in the liquid helium. In these tests, video images of the solid particle formation were recorded, and the total mass flow rate of the hydrogen was measured. The mass of hydrogen that went into the gaseous phase was also recorded using a commercially available residual gas analyzer. The temperatures, pressures, and flow rates of the liquids and gases in the test apparatus were recorded as well. Testing conducted in 1999 recorded particles as small as 2 to 5 mm in diameter. The current testing extended the testing conditions to a very cold Dewar ullage gas of about 20 to 90 K above the 4 K liquid helium. With the very cold Dewar gas, the hydrogen freezing process took on new dimensions, in some cases creating particles so small that they seemed to be microscopic, appearing as infinitesimally small scintillations on the videotaped images.

Palaszewski, Bryan A.↗

A Comparison of Quartz Crystal Microbalance Measurements with Mass Spectrometer Determinations

An experimental program was undertaken in which mass accretion rates, as determined by a liquid nitrogen cooled quartz crystal microbalance, were compared with the mass flux rates, as determined by both a cycloidal type and a quadrupole type residual gas analyzer for five simple materials. The data indicate a high degree of correlation between these instruments insofar as the shape of the curves. There are large variations however among the absolute values.

Kruger, R.↗

A modified quadrupole mass spectrometer with custom RF link rods driver for remote operation

A commercial quadrupole residual gas analyzer system has been upgraded for operation at extended cable lengths. Operation inside a vacuum chamber for the standard quadrupole nude head is limited to approximately 2 m from its externally located rf/dc generator because of the detuning of the rf oscillator circuits by the coaxial cable reactance. The advance of long distance remote operation inside a vacuum chamber for distances of 45 and 60 m was made possible without altering the quadrupole's rf/dc generator circuit by employing an rf link to drive the quadrupole rods. Applications of the system have been accomplished for in situ space simulation thermal/vacuum testing of sophisticated payloads.

Tashbar, P. W.↗

A remote operation quadrupole mass spectrometer using a custom radio-frequency link approach

A commercial quadrupole mass spectrometer (residual gas analyzer, RGA) system has been modified to operate at large separations of its electronics console and sensing head. The methods implemented have made practical applications, as well as operation, of such a system possible for the first time. This advance was stimulated by a need for placing sensors at remote (45 or 60 m) chamber locations for space simulation testing of orbital flight spacecraft. Emphasis is placed on instrument functional requirements and describing the hardware changes and adjustment techniques necessary to assure operation at the extended cable lengths.

Tashbar, P. W.↗

Requirements for long-life operation of inert gas hollow cathodes: Preliminary report

An experimental investigation was initiated to establish conditioning procedures for reliable hollow cathode operation via the characterization of critical parameters in a representative cathode test facility. From vacuum pumpdown rates, it was found that approximately 1.5 hours were required to achieve pressure levels within 5 percent of the lowest attainable pressure for this facility, depending on the purge conditions. The facility atmosphere was determined by a residual gas analyzer to be composed of primarily air and water vapor. The effects of vacuum pumping and inert gas purging were evaluated. A maximum effective leakage rate of 2.0 x 10(exp -3)sccm was observed and its probable causes were examined. An extended test of a 0.64 cm diameter Mo-Re hollow cathode was successfully completed. This test ran for 504 hours at an emission current of 23.0 amperes and a xenon flow rate of 6.1 sccm. Discharge voltage rose continuously from 15 to 21 volts over the course of the test. The temperature of the cathode body during the test was relatively stable at 1160 C. Post-test examination revealed ion-bombardment texturing of the orifice plate to be the only detectable sign of wear on the hollow cathode.

Verhey, Timothy R.↗

Requirements for long-life operation of inert gas hollow cathodes - Preliminary results

An experimental investigation was initiated to establish conditioning procedures for reliable hollow cathode operation via the characterization of critical parameters in a representative cathode test facility. From vacuum pumpdown rates, it was found that approximately 1.5 hours were required to achieve pressure levels within 5 percent of the lowest attainable pressure for this facility, depending on the purge conditions. The facility atmosphere was determined by a residual gas analyzer to be composed of primarily air and water vapor. The effects of vacuum pumping and inert gas purging were evaluated. A maximum effective leakage rate of 2.0 x 10 (exp -3) sccm was observed and its probable causes were examined. An extended test of a 0.64 cm diameter Mo-Re hollow cathode was successfully completed. This test ran for 504 hours at an emission current of 23.0 amperes and a xenon flow rate of 6.1 sccm. Discharge voltage rose continuously from 15 to 21 volts over the course of the test. The temperature of the cathode body during the test was relatively stable at 1160 C. Post-test examination revealed ion-bombardment texturing of the orifice plate to be the only detectable sign of wear on the hollow cathode.

Verhey, Timothy R.↗

The JPL Molecular Contamination Investigation Facility

The Molecular Contamination Investigation Facility (MCIF) is discussed in terms of its use for improving the far-UV performance of a camera and its broader applications. The MCIF incorporates two independent vacuum systems with sample isolation chambers and regulated heat exchangers as well as three quartz-crystal microbalances (QCMs) and a residual gas analyzer. One cryogenic QCM is heat sunk into an LN2 heat exchanger, while the others are thermoelectrically controlled and are heat sunk into a regulated heat exchanger. Outgas accumulation can be measured at three surface temperatures between -180 and 80 C simultaneously, and results are presented for the testing of 34 samples in a large-chambered system and 22 samples in a system with a smaller chamber. The MCIF results provide a database for fabrication processes, material selection, maximum bakeout temperatures, and the development of an ultraclean bakeout chamber.

Taylor, Daniel M.↗

Arcjet system integration development

Compatibility between an arcjet propulsion system and a communications satellite was verified by testing a Government-furnished, 1.4 kW hydrazine arcjet system with the FLTSATCOM qualification model satellite in a 9.1-meter (30-foot) diameter thermal-vacuum test chamber. Background pressure was maintained at 10(exp -5) torr during arcjet operation by cryopumping the thruster exhaust with an array of 5 K liquid helium cooled panels. Power for the arcjet system was obtained from the FLTSATCOM battery simulator. Spacecraft telemetry was monitored during each thruster firing period. No changes in telemetry data attributable to arcjet operation were detected in any of the tests. Electromagnetic compatibility data obtained included radiated emission measurements, conducted emission measurements, and cable coupling measurements. Significant noise was observed at lower frequencies. Above 500 MHz, radiated emissions were generally within limits, indicating that communication links at S-band and higher frequencies will not be affected. Other test data taken with a diagnostic array of calorimeters, radiometers, witness plates, and a residual gas analyzer evidenced compatible operation, and added to the data base for arcjet system integration. Two test series were conducted. The first series only included the arcjet and diagnostic array operating at approximately 0.1 torr background pressure. The second series added the qualification model spacecraft, a solar panel, and the helium cryopanels. Tests were conducted at 0.1 torr and 10(exp-5) torr. The arcjet thruster was canted 20 degrees relative to the solar panel axis, typical of the configuration used for stationkeeping thrusters on geosynchronous communications satellites.