Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rf filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Integration Development and Testing of Rear Transition Monitor for Beam Current Monitoring System

Addressing baseline effects in accelerator environments is crucial for accurate data acquisition and analysis, since baseline effects can obscure signal clarity and impact the reliability of beam current monitoring systems. There are many potential contributors to baseline noise, such as variations in beam dynamics, electromagnetic interference from nearby equipment, or RF interference. Previous applications of noise reduction systems don t sufficiently filter sources of asynchronous noise, so a new algorithm was implemented. A simulation dataset was created to replicate beam conditions and a Red Pitaya FPGA was used to collect data through the streaming application. A Python script was developed to implement noise reduction algorithms and efforts were made to integrate real-time data streaming with the Redis platform and Acnet Front End infrastructure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and fabrication of ion traps for low RF power dissipation

Large surface-electrode ion traps with multiple trapping regions and junctions are a natural approach to scaling trapped ion quantum computers, supporting the connectivity and ion counts necessary for complex quantum algorithms. However, a major hurdle in this scaling is on-chip power dissipation from the applied RF voltage, which increases at a rate between linear and cubic relative to trap size, depending on whether the losses are dielectric or Ohmic. Here, we present two versions of a trap with features designed to reduce both types of RF power dissipation. The first variant contains a raised RF electrode that increases the electrode–ground distance to reduce capacitance. Different DC voltage sources are demonstrated on this trap to show that technical noise before the filter remains the dominant source of voltage noise and therefore motional heating. The second variant additionally includes a method for removing dielectric from beneath the RF electrode to further reduce dielectric losses. These traps were demonstrated at room temperature with 40 Ca + ions. In conclusion, the similar heating rates and heating rate axial frequency dependencies between 2.4 and 3.0 MHz illustrate that this dielectric modification is not detrimental to trap performance.

Sterk, J. D. [Sandia National Laboratories (SNL-NM↗

KIPM Detector Characterization in QUIET

Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators that sense energy depositions in the substrate through a transient shift in their resonant frequency. In this work, I installed new devices in the QUIET cryogenic facility and used a network analyzer to drive them across a range of power levels. At each setting, I measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. Despite the increased noise at low power, the model consistently captured the resonance behavior. I first measured the resonance parameters as a function of RF drive power, then repeated the measurement across a range of temperatures to test whether the device behaved like an MKID. While the notch-filter fits captured the resonance reliably, the observed temperature dependence did not match the expected MKID signature — indicating that these first in-house fabricated chips are not yet functioning as true MKIDs. Overall, this reframes our work as a study of resonance parameter extraction and identification, pointing towards future iterations of device design and fabrication to get the true MKID response.

Savitala, Akash [U. Washington, Seattle (main); Fe↗

Deliberate Motion Analytics Applied to CUAS Sensor Fusion

The Advanced Reactor Safeguards and Security (ARSS) program in the Department of Energy’s Office of Nuclear Energy (DOE-NE) seeks to identify new technology solutions for safeguards and security challenges associated with domestic deployment of advanced nuclear reactors. Research in the ARSS program is investigating alternative physical protection system (PPS) approaches that leverage new detection technologies. This report shows test results from a new form of artificial intelligence (AI) that is called deliberate motion analytics (DMA) when used to spatially and temporally fuse active radar and passive radio frequency (RF) detection that significantly improves detection of uncrewed aircraft systems (UASs). DMA is designed to filter out false positive alarms yet provide highly reliable intrusion detection at nuclear power plants (NPPs) and advanced small modular reactor (ASMR) perimeters. This form of AI is considered to be an enabling technology for security of the future and supports the ARSS investigation of alternative PPSs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Tuning of strong nonlinearity in radio-frequency superconducting-quantum-interference-device meta-atoms

Strong nonlinearity of a self-resonant radio-frequency (rf) superconducting-quantum-interference-device (SQUID) meta-atom is explored via intermodulation (IM) measurements. Previous work in zero dc magnetic flux showed a sharp onset of IM response as the frequency sweeps through the resonance. A second onset at higher frequency was also observed, creating a prominent gap in the IM response. By extending those measurements to nonzero dc flux, different dynamics are revealed, including dc flux tunability of the aforementioned gaps and enhanced IM response near geometric resonance of the rf SQUID. These features observed experimentally are understood and analyzed theoretically through a combination of a steady-state analytical modeling and a full numerical treatment of the rf SQUID dynamics. The latter in addition predicts the presence of chaos in narrow parameter regimes. Here, the understanding of intermodulation in rf SQUID metamaterials is important for producing low-noise amplification of microwave signals and tunable filters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of Polarization-Dependent Changes in Higher-Order Mode Responses as a Function of Transverse Beam Position in Tesla-Type Cavities at FAST

Higher-order modes (HOMs) in superconducting rf cavities present problems for an electron bunch traversing the cavity in the form of long-range wakefields from previous bunches. These may dilute the emittance of the macropulse average, especially with low emittance beams at facilities such as the European X-ray Free-electron Laser (XFEL) and the upgraded Linac Coherent Light Source (LCLS-II). Here we present observations of HOMs driven by the beam at the Fermilab Accelerator Science and Technology (FAST) facility. The FAST facility features two independent TESLA-type cavities (CC1 and CC2) after a photocathode rf gun followed by an 8-cavity cryomodule. The HOM signals were acquired from cavities using bandpass filters of 1.75 ± 0.15 GHz, 2.5 ± 0.2 GHz, and 3.25 ± 0.2 GHz and recorded using an 8-GHz, 20 GSa/s oscilloscope. The frequency resolution obtained is sufficient to separate polarization components of many of the HOMs. These HOM signals were captured from CC1 and cavities 1 and 8 of the cryomodule for various initial trajectories through the cavities, and we observe correlations between trajectory, HOM signals, and which polarization component of a mode is affected.

Thurman-Keup, Randy Michael↗

Modeling the CEBAF Injector at 200 kV: Investigating K-Long Beam Conditions with and without Wien Filter

The upcoming K-Long experiment [1] ain Hall D at Jefferson Lab presents unique beam requirements, featuring a significantly low bunch repetition rate and an unusually high bunch charge. This experiment, which utilizes the CEBAF accelerator in conjunction with the GlueX experimental setup, aims to study strange hadron spectroscopy by measuring the differential cross section and polarizations of produced hyperons such as Λ, Σ, Ξ, and Ω. By directing an intense K-Long beam towards the LD2/LH2 target, new and valuable data can be obtained. To optimize the CEBAF injector specifically for this experiment, we employed Multi-Objective Genetic Optimization (MGO) using General Particle Tracer (GPT) simulations. Through this approach, we determined the optimal magnetic elements and radiofrequency (RF) settings required to achieve a K-Long bunch charge of 0.64 pC at an energy of 200 kV. We conducted simulations with both the Wien Filter turned on and off to examine its impact on the beam. Furthermore, we investigated the transmission efficiency and beam characteristics of electron beams with varying charge per bunch through the injector, considering the simultaneous operation of all four CEBAF Halls. The results of our study offer valuable insights and guidance for optimizing the CEBAF injector not only for the Jefferson Lab K-Long experiment but also for other experiments that entail similar beam conditions.

Pokharel, Sunil↗

Design and Prototyping of the 162.5 MHz PIP-II RF Reference-Line Station

The Proton Improvement Plan II (PIP-II) Reference Line distributes phase-stable radio-frequency signals so accelerating cavities transfer energy to the proton beam at the correct point in each RF cycle. The full system contains 162.5, 325, and 650 MHz sections; this project focuses on the 162.5 MHz station. Commercial filters, amplifiers, splitters, mixers, and hardware were assembled into a compact, serviceable heat-plate layout and tested to verify performance metrics at 162.5 MHz.

Subedi, Harsheet [Unlisted, US]↗

Edge treatment for spurious mode suppression in thin-film lithium niobate resonators

Abstract Thin-film lithium niobate is an attractive material for RF acoustic devices because of its high electromechanical coupling. However, due to the large coupling and the high anisotropy, thin-film lithium niobate resonators are prone to accidental resonances called spurious modes. These modes compromise the frequency response of the resonators, limiting their use in filter and oscillator applications. In this work, we present a novel method of spurious mode suppression through a special edge treatment etch process. Two thin-film lithium niobate resonators were fabricated, one with smooth sidewalls and one with the edge treatment. It was found that the edge-treated resonators show a weaker spurious mode response. This is potentially a new way to mitigate spurious resonances, a major issue in lithium niobate Lamb wave devices.

36 MATERIALS SCIENCE↗

Instabilities driven by the fundamental crabbing mode

The Electron Ion Collider (EIC) requires crab cavities to correct for crossing angle effects. These cavities produce a time varying horizontal kick that makes the collision head on in the center of mass frame of the bunches. This results in a luminosity that is very close to the the luminosity obtained without a crossing angle. Producing the kick requires a transverse RF field. This field requires a superconducting resonator and reasonable power levels require loaded quality factors of order a million. This results is a very large transverse impedance for the crabbing mode. The horizontal beta function is large and this, coupled with the large transverse impedance of the resonator can lead to strong instabilities. In the first section of the paper a simple model is used to describe the situation without feedback. There are large ranges of tune leading to strong instabilities in both the electron and hadron storage rings of the EIC. These estimates are confirmed with simulations. In the second section, RF feedback is used to reduce the apparent impedance of the crabbing mode. Simulating the actual feedback would require both a significant rewrite of the tracking code and a significant reduction in computational speed. Instead, the apparent impedance is fitted using one pole filters, which allows use of the existing simulation code. In the third section a transverse damping system is outlined.

43 PARTICLE ACCELERATORS↗

Optical encoder devices and systems

Devices, systems and methods for encoding information using optical components are described. An example photonic filtered sampler includes a spectral shaper configured to receive an optical pulse train, a dispersive element positioned to receive an output of the spectral shaper and to expand spectral contents thereof in time, and a modulator configured to receive an output of the dispersive element and a radio frequency (RF) signal, and to produce a modulated output optical signal in accordance with the RF signal. In this configuration, one or more characteristics of the modulated output optical signal is determined based on a spectral shape provided by the spectral shaper and dispersive properties of the dispersive element.

Buckley, Brandon Walter↗

Jefferson Laboratory C100 Superconducting Radio-Frequency Cavity Fault Data, 2020

The dataset was created to train machine learning models for the task of identifying the (1) cavity and (2) fault type from C100-type cryomodules at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), thereby replacing the time-consuming efforts of a subject matter expert. Superconducting radio-frequency (SRF) cavity trips represent a significant source of accelerator downtime. Real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type would give control room operators valuable feedback for corrective action planning. The anticipated benefit is increased beam-on-target time for users and provides performance metrics that can be used to improve future cavity designs. A series of 17 RF signals are recorded for each of the 8 cavities in a C100 cryomodule every time a cavity trips. These time-series signals are written to file using a specially designed data acquisition system. The dataset represents fault events recorded during Continuous Electron Beam Accelerator Facility (CEBAF) beam operations between January 18, 2019 and March 9, 2020. The following filtering steps were applied to collected data; (1) only 4 of the 17 signals per cavity are retained (GMES, GASK, CRFP, DETA2) (2) only events with data from each of the eight cavities in the cryomodule are kept, (3) only events that were sampled at 5 kHz were kept, (4) events from cryomodule 0L04 were neglected, (5) events occurring between February 4, 3PM and February 5, 12PM were neglected. As a result of preprocessing, the dataset is comprised of 2,375 unique events. The full dataset is comprised of three files: features.csv, cavity_labels.csv, fault_labels.csv. Each instance in faults.csv includes a timestamp (“date_time”), a label for the cryomodule which experienced the trip (“zone_label”), and 192 features (“feature_1”, “feature_2”... “feature_192”). The features correspond to 6 autoregressive features for each of 4 signals per cavity for each of the 8 cavities (6 × 4 signals/cavity × 8 cavities/cryomodule = 192). To deal with the large variation of signal amplitudes, time-series standardization via the z-score (standard score) function was applied prior to computing the features. For each instance, there is an associated label for the (1) cavity which faulted first (cavity_labels.csv) and (2) the type of fault that caused the trip (fault_labels.csv). The cavity identification can take values of [0, 1, 2, 3, 4, 5, 6, 7, 8] and the fault type can take values of [‘Microphonics’, ‘Quench_100ms’, ‘Controls_Fault’, ‘E_Quench’, ‘Quench_3ms’, ‘Single_Cav_Turn_Off’ , ‘Heat_Riser_Choke’, ‘Multi_Cav_Turn_Off’].

43 PARTICLE ACCELERATORS↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Bouger's Law Shell Ionospheric Transfer Function

Ionospheric transfer function (ITF) algorithms determine the effects of the ionosphere on an electromagnetic (EM) radio-frequency (RF) signal as it propagates through. In this report, the Bouger’s law shell model is outlined. This ITF is very similar to the Snell’s Law Shell ITF; however, in this formulation, plasma parameters in the ionosphere are allowed to change radially. This algorithm is expressed in the frequency domain. In this way, it is applied as linear time invariant (LTI) filter function. Signals in this report are assumed to have only a single component (i.e. x, y or z in a rectangular coordinate system). Multi-component signals can be treated simply by applying the specific ITF to each component separately.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact Coaxial HOM Damper for SRF Cavities

SRF technology enable particle accelerators operate with greater average beam currents and higher duty cycles. In these regimes parasitic excitation of the cavity HOM spectrum become the limiting factor due to extra RF losses and instabilities appearing in the beam. We discuss the limitations of HOMs for large accelerator projects as the Fermilab MI upgrade and the proposed future circular and linear colliders EIC and ILC. A new compact HOM damper concept is suggested providing required HOM suppression. The idea is based on an oversized coaxial line with radial sections, which is directly connected to the axial region of the SRF cavity. Such radially sectioned coaxial works as a filter for the operating mode, while being transparent for the HOMs. Implementations of this design for the accelerator and crab cavities developed for the MI and EIC machines, respectively, are discussed.

Lunin, A. [Fermilab]↗

Robust PCA-Deep Belief Network Surrogate Model for Distribution System Topology Identification with DERs

With the expansion of distribution networks and increased penetration of distributed energy resources (DERs), it is becoming increasingly important to obtain accurate distribution network topology in real-time. In this paper, a robust principal component analysis coupled deep belief network (PCA-DBN) surrogate model is proposed for distribution system topology identification. It integrates the benefits of robust feature extraction from PCA to deal with data quality issues and filter out noise, and the strength of DBN in capturing the nonlinear relationship between voltage amplitudes and the binary states of switchable connections. This also significantly reduces the DBN training complexity without loss of accuracy. It is shown that the widely used standard deviation of voltage drop and the voltage covariance matrix features yield less accuracy as compared to that of the voltage amplitudes in presence of high penetration of DERs and ZIP loads. Comparison results with other alternatives, such as the random forest (RF), multi-output regression (MOR) and the traditional DBN methods demonstrate that the proposed method can achieve a much higher topology identification accuracy while maintaining robustness to missing data and measurement noise under various penetration levels of DERs.

deep belief network↗

Full-Array Noise Performance of Deployment-Grade SuperSpec mm-Wave On-Chip Spectrometers

SuperSpec is an on-chip filter bank spectrometer designed for wideband moderate-resolution spectroscopy at millimeter wavelengths, employing TiN kinetic inductance detectors. SuperSpec technology will enable large-format spectroscopic integral field units suitable for high-redshift line intensity mapping and multi-object spectrographs. In previous results, we have demonstrated noise performance in individual detectors suitable for photon noise-limited ground-based observations at excellent mm-wave sites. Here, we present the noise performance of a full R similar to 275 spectrometer measured using deployment-ready RF hardware and software. We report typical noise equivalent powers through the full device of similar to 3x10 -16 W Hz -1/2 at expected sky loadings, which are photon noise dominated. Based on these results, we plan to deploy a six-spectrometer demonstration instrument to the Large Millimeter Telescope in early 2020.

47 OTHER INSTRUMENTATION↗