Search NASA⌕ Search

SEARCH · Search NASA

Results for “Room Return”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Select Electronic Parts Operation at Extreme Low Temperature

The purpose of the study presented in this paper is to extend the test period of a selected set of electronics parts at cryogenic condition to dwell period of about 24 hours to demonstrate extreme cold operational capability of these components. The parts tested are tantalum polymer, BX and P90 type ceramic capacitors, thick film resistors, analog multiplexers, a digital inverter, and a D-flip-flop. These parts were tested to assist identifying candidate components that can be used for development of a cold capable telemetry board. There are several past investigations that have shown that COTS (commercial-off-the-shelf) capacitors and resistors tested at cryogenic temperatures and frequencies up to 10MHz did not exhibit significant changes in capacitance and resistance values. Also, there are several test results for active parts. These past tests collected measurements during a temperature sweep from room temperature down to cryogenic temperature with very short dwell time at cryogenic temperature, and back to room temperature. This study extends the operational dwell time to at least 24 hours and returning to room temperature operation without significant degradation in performance, thus, demonstrating the potential for longer dwell time in actual operation in these extreme cold temperatures and a method for identifying the cold operability.

Ashtijou, Mohammad↗

Technique for stripping Teflon insulated wire

Cryogenic stripping of Teflon insulated wire leaves no residue and produces no physical damage. After the wire is immersed in liquid nitrogen, bent slightly, and returned to room temperature, the Teflon is removed by fingernails or flat-nosed pliers.

Babb, B. D.↗

The Qualification of Sealability and Creep Relaxation of Additively Manufactured Zytel Gaskets for PEM Fuel Cells

The purpose of this thesis is to study the feasibility of low-cost additive manufacturing of gaskets for proton exchange membrane fuel cells exposed to extreme temperature conditions ranging from -55°C to 100°C. With the growing popularity and decreasing costs of additive manufacturing technologies, specifically Material Extrusion (ME), research is being conducted to determine the feasibility of ME components. Thermally cycled PEMFCs may exhibit accelerated gasket deterioration, therefore, the mechanical stability of material extruded gaskets following a harsh thermal cycle must be assessed. The feasibility of the material extruded gaskets will be proven by manufacturing optimization and mechanical testing. The target material for this study is Zytel by DuPont Chemical. The mechanical stability will be assessed via sealability and creep relaxation testing according to ASTM F37B and ASTM F38B respectively. Because the capabilities to conduct sealability testing at temperature were not available, each specimen was thermally soaked and allowed to return to room temperature prior to testing. As a result of sealability experiments, the 100°C-soaked specimens resulted in lower leak rates with a higher precision when compared to specimens soaked at -55°C and 22°C at across all compressive loads. It was observed from results from creep relaxation testing that there is thermal contraction and expansion occurring at 55°C and 100°C respectively, which can be observed by the resultant graphs. The recoverability of thermally cycled specimens are better than those that just experienced a high temperature hold. After the seven-day thermal cycle, the samples stabilized and maintained their structure.

Lazarin, Robert↗

High-frequency electrical behavior in V 3 O 5 thin films

Vanadium oxides are known for their metal–insulator transition (MIT), with V 3 O 5 being notable for its transition temperature exceeding room temperature. At about 430 K, this material shows a change in crystal symmetry accompanied with one order of magnitude increase in its electrical conductivity and alterations in its optical properties. Although the property changes during the MIT in V 3 O 5 are less pronounced than those observed in VO 2 , its transition temperature is 90 K higher, making it appealing for applications requiring elevated temperatures. In this article, the high-frequency characteristics were determined in a V 3 O 5 two-terminal device in the range from 5 to 35 GHz. The S-parameters showed that the return loss at room temperature was close to −1.5 dB, and the isolation between ports was approximately −50 dB. At temperatures above the metal–insulator transition, the isolation decreased to around −40 dB at 35 GHz. For S11 and S22, similar behavior was observed at room temperature, with a notable change in the S-parameter phase of the device. This behavior suggests that V 3 O 5 may function well as a capacitor because the considerable change in phase could control the flow of electrical signals in devices. This property also may be used for matching purposes, especially considering its response to temperature changes. Additionally, conductivity calculation from S-parameters shows a decrease of approximately two orders of magnitude at 500 K and one order of magnitude at 300 K compared to DC values. These findings highlight V 3 O 5 potential for integration into radio frequency devices that demand consistent performance in high-temperature environments.

36 MATERIALS SCIENCE↗

Liquid-Oxygen-Compatible Cement for Gaskets

Fluorelastomer and metal bonded reliably by new procedure. To cure fluoroelastomer cement, metal plate/gasket assembly placed in vacuum bag evacuated to minimum vacuum of 27 inches (69 cm) of mercury. Vacuum maintained throughout heating process and until assembly returns to ambient room temperature. Used to seal gaskets and O-rings or used to splice layers of elastomer to form non-standard sized O-rings. Another possible use is to apply protective, liquid-oxygen-compatible coating to metal parts.

Elmore, N. L.↗

Natural Air Purifier

NASA environmental research has led to a plant-based air filtering system. Dr. B.C. Wolverton, a former NASA engineer who developed a biological filtering system for space life support, served as a consultant to Terra Firma Environmental. The company is marketing the BioFilter, a natural air purifier that combines activated carbon and other filter media with living plants and microorganisms. The filter material traps and holds indoor pollutants; plant roots and microorganisms then convert the pollutants into food for the plant. Most non-flowering house plants will work. After pollutants have been removed, the cleansed air is returned to the room through slits in the planter. Terra Firma is currently developing a filter that will also disinfect the air.

Source record↗

Influence of overhead HVAC and aerosol control strategies on coarse mode particle dispersion and exposure in a full-scale room experiment

Coarse mode respiratory aerosols can carry viral loads over long distances and have very different dynamics than submicron particles, but experimental studies under realistic conditions remain limited. Here, to study the differential impacts on exposure under different mixing conditions, we co-released 7–10 µm particles and carbon dioxide (CO 2 )—which served as an indicator of gas and submicron particle dynamics—in a 158 m 3 room at LBNL's FLEXLAB facility with an overhead heating, ventilation, and air conditioning (HVAC) system. The room was arranged as a distanced meeting then a classroom with eight heated manikins and a researcher. Spatial variability was measured using 16 particle counters and 22–26 CO 2 sensors throughout the space. Conditions included: HVAC off or supply air at 1000-1060 m 3 h -1 at neutral, cooling, or heating temperatures; with and without 20% outdoor air; and added HVAC filtration, portable air cleaners (PACs), or a physical barrier between the speaker and occupants. We found that good mixing via neutral or cooling supply air or use of PACs under heating lowered coarse particle exposure at some locations, but increased exposure for one-quarter to two-thirds of manikins compared to poor mixing under heating. A physical barrier reduced direct transfer of coarse particles during heating, but less during cooling. High spatial variability shows that a single measurement cannot represent occupant exposure. Instantaneous air mixing assumptions overstate the effectiveness of ventilation, HVAC filtration, and upper-room germicidal ultraviolet disinfection for coarse particles, as relatively few particles reach the return grille or upper room under most conditions.

Air mixing↗

Delta/Wind Launch with Isolated Cameras from Continuous Recording

The Wind spacecraft represents one of NASA's contributions to the International Solar Terrestrial Program (ISTP), an international effort to quantify the effects of solar energy on the Earth's magnetic field. Wind will provide continuous measurement of the solar wind, particularly charged particles and magnetic field data. The specific objectives of Wind are to: (1) provide complete plasma, energetic particle, and magnetic field input for magnetospheric and ionospheric studies; (2) determine the magnetospheric output to interplanetary space in the upstream region; (3) investigate basic plasma processes occurring in the near-Earth solar wind; and (4) provide baseline ecliptic plane observations to be used in heliospheric studies. This videotape shows the pre-dawn launch of the Wind spacecraft aboard a Delta 7925 on November 1, 1994. After the countdown and launch, the tape shows the activity in the Telemetry Room at Kennedy Space Center, where people are following the progress of the spacecraft. Following the activity in the telemetry room, there are four different replays of the launch from different locations. After showing the replays of the launch, the video returns to the Telemetry Room when an important stage in the launch and flight is achieved.

Source record↗

Effects of Acute Exposures to Carbon Dioxide upon Cognitive Functions

Carbon dioxide (CO2) originates from human metabolism and typically remains about 10-fold higher in concentration on the International Space Station (ISS) than at the earth's surface. There have been recurring complaints by crew members of episodes of "mental viscosity" adversely affecting their performance, and there is evidence from the ISS that associates CO2 levels with reports of headaches by crewmembers. Consequently, flight rules have been employed to control CO2 below 3 mm Hg, which is well below the existing Spacecraft Maximum Allowable Concentration (SMAC) of 10 mm Hg for 24-hour exposures, and 5.3 mm Hg for exposures of 7 to 180 days. Headaches, while sometime debilitating themselves, are also symptoms that can provide evidence that physiological defense mechanisms have been breached, and there is evidence that CO2 has effects at levels below the threshold for headaches. This concern appears to be substantiated in reports that CO2 at concentrations below 2 mm Hg substantially reduced some cognitive functions that are associated with the ability to make complex decisions in conditions that are characterized by volatility, uncertainty, complexity, ambiguity, and delayed feedback. These are conditions that could be encountered by crews in off-nominal situations or during the first missions beyond low earth orbit. Therefore, we set out to determine if decision-making under volatile, uncertain, confusing and ambiguous circumstances, where feedback is delayed or absent, is correlated with low levels of CO2 during acute exposures (several hours) in crew-like subjects and to determine if additional cognitive domains are sensitive to concentrations of CO2 at, or below, current ISS levels by using a test battery that is currently available onboard ISS. We enrolled 22 volunteers (8 females, 14 males) between the ages of 30-55 (38.8 +/- 7.0) years whose training and professional experience reflect that of the astronaut corps. Subjects were divided among 4 study groups. Exposures occurred in the 20-foot environmental chamber in Bldg 7 at JSC. Each group was exposed to each of four concentrations of CO2 (600, 1200, 2500, and 5000 ppm), and the exposure order was balanced across the groups which were randomly assigned to 4 possible complete exposure orders. Study participants and investigators were blinded to the exposure order. Each exposure lasted 4 hours and occurred on the same day each week for 4 consecutive weeks. Testing included the Strategic Management Simulation (SMS) methodology and the Cognition battery of psychometric measures that are being utilized aboard the ISS. Subjects participated in a familiarization session one week prior to the start of exposure sessions. Each exposure session followed the schedule noted in Figure 1 below. On the morning of each exposure, subjects completed the Cognition battery in a conference room at indoor ambient CO2 levels. Subjects then entered the exposure chamber and were acclimated to the environment for 15 minutes before completing another round of the Cognition battery. After a 20 minute rest, subject completed the approx.80 minute SMS. Subjects were allowed another 20 minute rest period before completing the final Cognition test battery in the exposure chamber. Subjects then returned to the conference room where they completed one final round of Cognition. Data from both testing methodologies are currently being analyzed and will be presented. Study investigators have not yet been unblinded to the coded exposure concentrations, but preliminary results suggest differences.

Ryder, V. E.↗

Mechanical characteristics of stability-bleed valves for a supersonic inlet

Mechanical characteristics of a set of direct-operated relief valves used in a throat-bypass stability-bleed system designed for the YF-12 aircraft inlet are described. A comparison of data taken before and after the windtunnel tests (at room temperature) showed that both the effective spring rate and the piston friction had decreased during the wind tunnel tests. In neither the effective spring rate nor the piston friction was the magnitude of change great enough to cause significant impairment of overall system effectiveness. No major valve mechanical problems were encountered in any of the tests. During high temperature bench tests, piston frictional drag increased. The friction returned to its initial room temperature value when the stability-bleed valve was disassembled and reassembled. The problem might be solved by using a different material for the piston sleeve bearing and the piston rings.

Neiner, G. H.↗

Mutations in the gravity persistence signal loci in Arabidopsis disrupt the perception and/or signal transduction of gravitropic stimuli

Gravity plays a fundamental role in plant growth and development, yet little is understood about the early events of gravitropism. To identify genes affected in the signal perception and/or transduction phase of the gravity response, a mutant screen was devised using cold treatment to delay the gravity response of inflorescence stems of Arabidopsis. Inflorescence stems of Arabidopsis show no response to gravistimulation at 4 degrees C for up to 3 h. However, when gravistimulated at 4 degrees C and then returned to vertical at room temperature (RT), stems bend in response to the previous, horizontal gravistimulation (H. Fukaki, H. Fujisawa, M. Tasaka [1996] Plant Physiology 110: 933-943). This indicates that gravity perception, but not the gravitropic response, occurs at 4 degrees C. Recessive mutations were identified at three loci using this cold effect on gravitropism to screen for gravity persistence signal (gps) mutants. All three mutants had an altered response after gravistimulation at 4 degrees C, yet had phenotypically normal responses to stimulations at RT. gps1-1 did not bend in response to the 4 degrees C gravity stimulus upon return to RT. gps2-1 responded to the 4 degrees C stimulus but bent in the opposite direction. gps3-1 over-responded after return to RT, continuing to bend to an angle greater than wild-type plants. At 4 degrees C, starch-containing statoliths sedimented normally in both wild-type and the gps mutants, but auxin transport was abolished at 4 degrees C. These results are consistent with GPS loci affecting an aspect of the gravity signal perception/transduction pathway that occurs after statolith sedimentation, but before auxin transport.

NASA Discipline Plant Biology↗

High-temperature, high-pressure optical cells

For measuring the thermal diffusivity of HgCdTe melts by the laser-pulse method, an infrared transparent cell with flat windows of sufficient strength to withstand the high-vapor pressure of mercury had to be developed. Since mercury telluride expands on freezing, certain difficulties arose in returning the cell to room temperature without cracking it. T08 commercial fused silica is used in the construction of the cell, and the cells are transparent for wavelengths from about 3.5 microns in the infrared to 260 nm in the ultraviolet. The construction procedure for the required cells has been laborious. However, the obtained cell has routinely withstood internal pressures in excess of 60 atm at 900 C. Attention is given to the design of the windows, aspects of cell construction, and questions of loading.

Holland, L. R.↗

Preserving and Curating the Moon: Adventures in Lunar Core Processing

The lunar crust is the most easily accessible part of the Moon to both remote sensing and sample analyses and provides an archive of information about planetary formation, crustal evolution, and contains a wealth of information about the origin of the Earth-Moon system [e.g., 1-5]. The Apollo mission returned 382 kg of rocks, soil and core samples. Studies of these lunar samples are crucial for our understanding of the Moon’s formation and geological evolution, and for the past 50 years these returned samples have provided the foundation for lunar science [5]. The returned samples are stored and cared for in the lunar curation facility at NASA’s Johnson Space Center. This facility is comprised of a large suite of clean rooms, sample vaults for pristine and return samples, thin section labs, core and saw rooms, storage and working areas, and ancillary labs all designed to minimize contamination from the environment and other samples. Some of the returned samples were intentionally set aside and left unopened. Recently, the Apollo Next Generation Sample Analysis (ANGSA) initiative was designed to examine these pristine samples so the next generation of lunar scientists can further our insight into the Moon’s history. Here, we present the meticulous process that involves preparing for, and ultimately opening, one of the unopened core samples: Apollo 17 drive tube 73002,0,which was collected on the Moon from a landslide deposit near Lara Crater by astronauts Gene Cernan and Jack Schmitt. In order to open, examine, and curate 73002,0withminimalpotential contamination, great care had to be taken prior to opening its container. Beginning18 months before extrusion of the sample, all core processing equipment was pulled out of storage, identified, sorted, cleaned, and purged with nitrogen gas. However, limited institutional memory has made this step challenging as most of the former core processors from the Apollo area have retired or passed away. Twelvemonths prior to extrusion, table-top rehearsals were initiated to identify equipment and learn how it fits together and operates. Five months before extruding the real core, preparations further evolved to include the extrusion and dissection of a lunar core simulant. In addition, a mock-up glovebox was designed and built to allow for a more realistic practice environment. One month prior to extrusion, the actual core cabinet was prepared for use, which included fitting it with lights, a webcam, and power. The tool and equipment cleaning procedure was also modified to include increased cleanliness and sterility requirements. While still sealed, the core was CT scanned at the University of Texas at Austin to maximize its scientific return. Days before the extrusion, witness plates and foil were deployed inside the core cabinet to monitor potential particle and organic contamination within the cabinet. On Nov. 5th, 2019, core sample 73002,0 was successfully opened and extruded(Fig.1). Dissection of 73002,0 began immediately afterwards and is still under way. Processing this sample will help us prepare for future sampling missions and core extrusions and will enable new scientific discoveries about the Moon.

C H Krysher↗

Ion-Conducting Thermoresponsive Films Based on Polymer-Grafted Cellulose Nanocrystals

Mechanically robust, thermo-responsive, ion-conducting nanocomposite films are prepared from poly(2-phenylethyl methacrylate) grafted cellulose nanocrystals (MxG-CNC-g-PPMA). One-component nanocomposite films of the polymer grafted nanoparticle (PGN) MxG-CNC-g-PPMA are imbibed with 30 wt% imidazolium-based ionic liquid, to produce flexible ion-conducting films. These films with 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (MxG-CNC-g-PPMA/[H]) not only displays remarkable improvements in toughness (>25 times) and tensile strength (>70 times) relative to the corresponding nanocomposites consisting of the ionic liquid imbibed in the two component CNC/PPMA nanocomposite, but also shows higher ionic conductivity than the corresponding neat PPMA with the same wt.% of ionic liquid. Notably, the one-component film containing 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (MxG-CNC-g-PPMA/[E]) exhibits temperature responsive ionic conduction. The ionic conductivity decreases at around 60°C as a consequence of the lower critical solution temperature (LCST) phase transition of the grafted polymer in the ionic liquid, which leads to phase separation. Moreover, holding the MxG-CNC-g-PPMA/[E] film at room temperature for 24 hours returns the film to its original homogenous state. These materials exhibit properties relevant to thermal cutoff safety devices (e.g., thermal fuse) where a reduction in conductivity above a critical temperature is needed.

36 MATERIALS SCIENCE↗

Plasma current collection of Z-93 thermal control paint as measured in the Lewis Research Center's plasma interaction facility

A sample of Z-93 thermal control paint was exposed to a simulated space environment in a plasma chamber. The sample was biased through a series of voltages ranging from -100 volts to +300 volts and electron and ion currents were measured. Currents were found to be in the micro-ampere range indicating that the material remains a reasonably good insulator under plasma conditions. As a second step, the sample was left in the chamber for six days and retested. Collected currents were reduced by from two to five times from the previous values indicating a substantial loss of conductivity. As a final test, the sample was removed, exposed to room conditions for two days, and returned to the chamber. Current measurements showed that the sample had partially recovered the lost conductivity. In addition to presenting these results, this report documents all of the experimental data as well as the statistical analyses performed.

Hillard, G. Barry↗

Lessons Learned From the Construction of a Portable Cleanroom for NASA OSIRIS-REx Mission Deintegration

NASA Johnson Space Center (JSC) Infrastructure and Astromaterials Acquisition & Curation Office completed construction and commissioning of the OSIRIS-REx (OREx) Deintegration portable cleanroom at the Utah Test and Training Range (UTTR). The new portable cleanroom was designed to receive the OREx sample return capsule from the landing point on the range to an ISO7 environment. Scientists used the portable clean-room to deintegrate the sample canister from the sample return capsule. Once separated, the sample canister was put in a container under nitrogen purge for transportation to B31 at the Johnson Space Center for astromaterial sample extraction, preliminary analysis, and long-term curation. The portable cleanroom was built by a subcontractor at their facility and then deconstructed to be transported to the remote location at UTTR. Since construction was completed in a remote location all tools and materials had to be transported from contractor site in Dallas, TX. The cleanroom was constructed within an existing facility, which provided conditioned air, electric power, and protection from the elements. Careful coordination was required between the host facility, cleanroom contractor, mission scientists, and JSC facilities and curation personnel. An existing anteroom at JSC was transported to UTTR and added to the portable cleanroom after there was concern about contamination without one for personnel entry/exit. The scientific study of organics is critical for the mission, so a stringent contamination control plan was implemented for low organics. Given these mission requirements the cleanroom construction materials were carefully selected to not hinder the scientific search for amino acids and the study of organics in the samples. The same cleanroom contractor that built the long-term astromaterial curation cleanroom back at JSC Houston, TX was selected to build the portable cleanroom and instructed to use the same materials. The cleanroom had double doors to open and allow the sample return capsule to fit into the cleanroom on its stand and be transferred to a clean stand already in the cleanroom. The portable cleanroom successfully completed its mission and the sample canister was safely deintegrated and transported to JSC under nitrogen purge.

astromaterials curation↗

Portable Cleanroom for NASA OSIRIS-REx Mission Deintegration

NASA Johnson Space Center (JSC) Infrastructure and Astromaterials Acquisition & Curation Office completed construction and commissioning of the OSIRIS-REx (OREx) Deintegration portable cleanroom at the Utah Test and Training Range (UTTR). The new portable cleanroom was designed to receive the OREx sample return capsule from the landing point on the range to an ISO7 environment. Scientists used the portable clean-room to deintegrate the sample canister from the sample return capsule. Once separated, the sample canister was put in a container under nitrogen purge for transportation to B31 at the Johnson Space Center for astromaterial sample extraction, preliminary analysis, and long-term curation. The portable cleanroom was built by a subcontractor at their facility and then deconstructed to be transported to the remote location at UTTR. Since construction was completed in a remote location all tools and materials had to be transported from contractor site in Dallas, TX. The cleanroom was constructed within an existing facility, which provided conditioned air, electric power, and protection from the elements. Careful coordination was required between the host facility, cleanroom contractor, mission scientists, and JSC facilities and curation personnel. An existing anteroom at JSC was transported to UTTR and added to the portable cleanroom after there was concern about contamination without one for personnel entry/exit. The scientific study of organics is critical for the mission, so a stringent contamination control plan was implemented for low organics. Given these mission requirements the cleanroom construction materials were carefully selected to not hinder the scientific search for amino acids and the study of organics in the samples. The same cleanroom contractor that built the long-term astromaterial curation cleanroom back at JSC Houston, TX was selected to build the portable cleanroom and instructed to use the same materials. The cleanroom had double doors to open and allow the sample return capsule to fit into the cleanroom on its stand and be transferred to a clean stand already in the cleanroom. The portable cleanroom successfully completed its mission and the sample canister was safely deintegrated and transported to JSC under nitrogen purge.

astromaterials curation↗

Computational Fluid Dynamics Simulations to Assess Spatial Variability and Optimal Ventilation Scenarios for Biological Laboratory Exposures

A significant amount of uncertainty exists regarding potential human exposure to laboratory biomaterials and organisms in Biosafety Level 2 (BSL-2) research laboratories. Computational fluid dynamics (CFD) modeling is proposed as a way to better understand potential impacts of different combinations of biomaterials, laboratory manipulations, and exposure routes on risks to laboratory workers. Here, in this study, we use CFD models to simulate airborne concentrations of contaminants in an actual BSL-2 laboratory under different configurations. Results show that ventilation configuration, sampling location, and contaminant source location can significantly impact airborne concentrations and exposures. Depending on the source location and airflow patterns, the transient and time-integrated concentrations varied by several orders of magnitude. Contaminant plumes from sources located near a return vent (or exhaust like a fume hood or ventilated biosafety cabinet) are likely to be more contained than sources that are further from the exhaust. Having a direct flow between the source and the exhaust (through-flow condition) may reduce potential exposures to individuals outside the air flow path. Designing a BSL-2 room with ventilation and airflow patterns that maximize through-flow conditions to the return/exhaust vents and minimize dispersion and mixing throughout the room is, therefore, recommended. CFD simulations can also be used to assist in characterizing the impacts of supply and return vent locations, room layout, and source locations on spatial and temporal contaminant concentrations. In addition, proper placement of particle sensors can also be informed by CFD simulations to provide additional characterization and monitoring of potential exposures in BSL-2 facilities.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗