Search NASASearch

SEARCH · Search NASA

Results for “SIGNAL MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Aerosol Radiative Effects: Expected Variations in Optical Depth Spectra and Climate Forcing, with Implications for Closure Experiment Strategies

We examine measurement strategies for reducing uncertainties in aerosol direct radiative forcing by focused experiments that combine surface, air, and space measurements. Particularly emphasized are closure experiments, which test the degree of agreement among different measurements and calculations of aerosol properties and radiative effects. By combining results from previous measurements of large-scale smokes, volcanic aerosols, and anthropogenic aerosols with models of aerosol evolution, we estimate the spatial and temporal variability in optical depth spectra to be expected in the Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX, planned for summer 1996 off the Eastern U.S. seaboard). In particular, we examine the expected changes in the wavelength dependence of optical depth as particles evolve through nucleation, growth by condensation and coagulation, and removal via sedimentation. We then calculate the expected radiative climate forcing (i.e. change in net radiative flux) for typical expected aerosols and measurement conditions (e.g. solar elevations, surface albedos, radiometer altitudes). These calculations use new expressions for flux and albedo changes, which account not only for aerosol absorption, but also for instantaneous solar elevation angles and the dependence of surface albedo on solar elevation. These factors, which are usually ignored or averaged in calculations of global aerosol effects, can have a strong influence on fluxes measured in closure experiments, and hence must be accounted for in calculations if closure is to be convincingly tested. We compare the expected measurement signal to measurement uncertainties expected for various techniques in various conditions. Thereby we derive recommendations for measurement strategies that combine surface, airborne, and spaceborne measurements.

Russell, Philip B.

A study to identify research issues in the area of electromagnetic measurements and signal handling of remotely sensed data

Research issues in the area of electromagnetic measurements and signal handling of remotely sensed data are identified. The following seven issues are discussed; platform/sensor system position and velocity, platform/sensor attitudes and attitude rates, optics and antennas, detectors and associated electronics, sensor calibration, signal handling, and system design.

Source record

Measuring Antenna Signal Delays

Signal delays in large dish antennas measured by method based on commercial frequency-modulated instrument. Measurements accurate within 3 ns on primary path lengths of 60 ns or more. Major benefit of method is user distinguishes between delay along the primary signal path and delays along multiple-reflection signal paths (multipaths), so multipath errors minimized or made insignificant in calibration of antenna delays.

T Y Otoshi

Airborne RF Measurement System (ARMS) and Analysis of Representative Flight RF Environment

Environmental radio frequency (RF) data over a broad band of frequencies (30 MHz to 1000 MHz) were obtained to evaluate the electromagnetic environment in airspace around several airports. An RF signal measurement system was designed utilizing a spectrum analyzer connected to the NASA Lancair Columbia 300 aircraft's VHF/UHF navigation antenna. This paper presents an overview of the RF measurement system and provides analysis of sample RF signal measurement data. This aircraft installation package and measurement system can be quickly returned to service if needed by future projects requiring measurement of an RF signal environment or exploration of suspected interference situations.

Koppen, Sandra V.

Assessment, Validation, and Refinement of the Atmospheric Correction Algorithm for the Ocean Color Sensors

The primary focus of this proposed research is for the atmospheric correction algorithm evaluation and development and satellite sensor calibration and characterization. It is well known that the atmospheric correction, which removes more than 90% of sensor-measured signals contributed from atmosphere in the visible, is the key procedure in the ocean color remote sensing (Gordon and Wang, 1994). The accuracy and effectiveness of the atmospheric correction directly affect the remotely retrieved ocean bio-optical products. On the other hand, for ocean color remote sensing, in order to obtain the required accuracy in the derived water-leaving signals from satellite measurements, an on-orbit vicarious calibration of the whole system, i.e., sensor and algorithms, is necessary. In addition, it is important to address issues of (i) cross-calibration of two or more sensors and (ii) in-orbit vicarious calibration of the sensor-atmosphere system. The goal of these researches is to develop methods for meaningful comparison and possible merging of data products from multiple ocean color missions. In the past year, much efforts have been on (a) understanding and correcting the artifacts appeared in the SeaWiFS-derived ocean and atmospheric produces; (b) developing an efficient method in generating the SeaWiFS aerosol lookup tables, (c) evaluating the effects of calibration error in the near-infrared (NIR) band to the atmospheric correction of the ocean color remote sensors, (d) comparing the aerosol correction algorithm using the singlescattering epsilon (the current SeaWiFS algorithm) vs. the multiple-scattering epsilon method, and (e) continuing on activities for the International Ocean-Color Coordinating Group (IOCCG) atmospheric correction working group. In this report, I will briefly present and discuss these and some other research activities.

Wang, Menghua

Brain signaling and behavioral responses induced by exposure to (56)Fe-particle radiation

Previous experiments have demonstrated that exposure to 56Fe-particle irradiation (1.5 Gy, 1 GeV) produced aging-like accelerations in neuronal and behavioral deficits. Astronauts on long-term space flights will be exposed to similar heavy-particle radiations that might have similar deleterious effects on neuronal signaling and cognitive behavior. Therefore, the present study evaluated whether radiation-induced spatial learning and memory behavioral deficits are associated with region-specific brain signaling deficits by measuring signaling molecules previously found to be essential for behavior [pre-synaptic vesicle proteins, synaptobrevin and synaptophysin, and protein kinases, calcium-dependent PRKCs (also known as PKCs) and PRKA (PRKA RIIbeta)]. The results demonstrated a significant radiation-induced increase in reference memory errors. The increases in reference memory errors were significantly negatively correlated with striatal synaptobrevin and frontal cortical synaptophysin expression. Both synaptophysin and synaptobrevin are synaptic vesicle proteins that are important in cognition. Striatal PRKA, a memory signaling molecule, was also significantly negatively correlated with reference memory errors. Overall, our findings suggest that radiation-induced pre-synaptic facilitation may contribute to some previously reported radiation-induced decrease in striatal dopamine release and for the disruption of the central dopaminergic system integrity and dopamine-mediated behavior.

NASA Discipline Radiation Health

Noise Source for Calibrating a Microwave Polarimeter

A correlated-noise source has been developed for use in calibrating an airborne or spaceborne Earth-observing correlation microwave polarimeter that operates in a in a pass band that includes a nominal frequency of 10.7 GHz. Deviations from ideal behavior of the hardware of correlation polarimeters are such as to decorrelate the signals measured by such an instrument. A correlated-noise source provides known input signals, measurements of which can be processed to estimate and correct for the decorrelation effect.

Piepmeier, Jeffrey R.

Airborne RF Measurement System and Analysis of Representative Flight RF Environment

Environmental radio frequency (RF) data over a broad band of frequencies were needed to evaluate the airspace around several airports. An RF signal measurement system was designed using a spectrum analyzer connected to an aircraft VHF/UHF navigation antenna installed on a small aircraft. This paper presents an overview of the RF measurement system and provides analysis of a sample of RF signal measurement data over a frequency range of 30 MHz to 1000 MHz.

Koppen, Sandra V.

Using Doppler Shifts of GPS Signals To Measure Angular Speed

A method has been proposed for extracting information on the rate of rotation of an aircraft, spacecraft, or other body from differential Doppler shifts of Global Positioning System (GPS) signals received by antennas mounted on the body. In principle, the method should be capable of yielding low-noise estimates of rates of rotation. The method could eliminate the need for gyroscopes to measure rates of rotation. The method is based on the fact that for a given signal of frequency ft transmitted by a given GPS satellite, the differential Doppler shift is attributable to the difference between those components of the instantaneous translational velocities of the antennas that lie along the line of sight from the antennas to the GPS satellite.

Campbell, Charles E., Jr.

ICESAT GLAS Altimetry Measurements: Received Signal Dynamic Range and Saturation Correction

NASAs Ice, Cloud, and land Elevation Satellite (ICESat), which operated between 2003 and 2009, made the first satellite-based global lidar measurement of earths ice sheet elevations, sea-ice thickness, and vegetation canopy structure. The primary instrument on ICESat was the Geoscience Laser Altimeter System (GLAS), which measured the distance from the spacecraft to the earth's surface via the roundtrip travel time of individual laser pulses. GLAS utilized pulsed lasers and a direct detection receiver consisting of a silicon avalanche photodiode and a waveform digitizer. Early in the mission, the peak power of the received signal from snow and ice surfaces was found to span a wider dynamic range than anticipated, often exceeding the linear dynamic range of the GLAS 1064-nm detector assembly. The resulting saturation of the receiver distorted the recorded signal and resulted in range biases as large as approximately 50 cm for ice- and snow-covered surfaces. We developed a correction for this saturation range bias based on laboratory tests using a spare flight detector, and refined the correction by comparing GLAS elevation estimates with those derived from Global Positioning System surveys over the calibration site at the salar de Uyuni, Bolivia. Applying the saturation correction largely eliminated the range bias due to receiver saturation for affected ICESat measurements over Uyuni and significantly reduced the discrepancies at orbit crossovers located on flat regions of the Antarctic ice sheet.

Sun, Xiaoli

Alaska SAR processor implementation of E-ERS-1

The synthetic aperture radar (SAR) data processing algorithm used by the Alaska SAR Facility (ASF) for the European Space Agency's first Remote-Sensing Satellite (E-ERS-1) SAR data are examined. Preprocessing highlights two features: signal measurement, which includes signal-to-noise ratio, replica measurement, and noise measurement; and Doppler measurement, which includes clutter lock and autofocus. The custom pipeline architecture performs the main processing with controls at the input interface, range correlator, corner-turn memory, azimuth correlator, and multi-look memory. The control software employs a flexible control scheme. The Committee on Earth Observation Satellites (CEOS) format encapsulates the ASF products. System performance for SAR image processing of E-ERS-1 data is reviewed.

Cuddy, David

Flight evaluation of a pneumatic system for unsteady pressure measurements using conventional sensors

A flight experiment was conducted to evaluate a pressure measurement system which uses pneumatic tubing and remotely located electronically scanned pressure transducer modules for in-flight unsteady aerodynamic studies. A parametric study of tubing length and diameter on the attenuation and lag of the measured signals was conducted. The hardware was found to operate satisfactorily at rates of up to 500 samples/sec per port in flight. The signal attenuation and lag due to tubing were shown to increase with tubing length, decrease with tubing diameter, and increase with altitude over the ranges tested. Measurable signal levels were obtained for even the longest tubing length tested, 4 ft, at frequencies up to 100 Hz. This instrumentation system approach provides a practical means of conducting detailed unsteady pressure surveys in flight.

Curry, Robert E.

Qualitative Event-Based Fault Isolation under Uncertain Observations

For many systems, automatic fault diagnosis is critical to ensuring safe and efficient operation. Fault isolation is performed by analyzing measured signals from the system, and reasoning over the system behavior to determine which faults have occurred, based on models of predicted faulty behavior. For dynamic systems, reasoning may be performed using qualitative analysis of the differences between measured signals and their predicted values, in which observations take the form of qualitative symbols. Such an approach is quick to isolate faults, but depends critically on correct generation of the qualitative symbols from the signals. In this paper, we develop an approach to qualitative event-based fault isolation for dynamic systems that is robust to incorrect qualitative observations. Observations are treated as uncertain, where multiple interpretations of an observation, each with its own probability, are considered. By interpreting observed symbols in a probabilistic manner, the approach degrades gracefully as the number of incorrectly-generated symbols increases. The approach is demonstrated on an electrical power system testbed, and experiments using real data obtained from the hardware demonstrate the improved fault isolation performance in the presence of incorrect symbol generation.

Daigle, Matthew

Carbon Nanotube Gas Sensor Using Neural Networks

The need to identify the presence and quantify the concentrations of gases and vapors is ubiquitous in NASA missions and societal applications. Sensors for air quality monitoring in crew cabins and ISS have been actively under development (Ref. 1). In particular, measuring the concentration of CO2 and NH3 is important because high concentrations of these gases pose a risk to ISS crew health. Detection of fuel and oxidant leaks in crew vehicles is critical for ensuring mission safety. Accurate gas and vapor concentrations can be measured, but this typically requires bulky and expensive instrumentation. Recently, inexpensive sensors with low power demands have been fabricated for use on the International Space Station (ISS). Carbon Nanotube (CNT) based chemical sensors are one type of these sensors. CNT sensors meet the requirements for low cost and ease of fabrication for deployment on the ISS. However, converting the measured signal from the sensors to human readable indicators of atmospheric air quality and safety is challenging. This is because it is difficult to develop an analytical model that maps the CNT sensor output signal to gas concentration. Training a neural network on CNT sensor data to predict gas concentration is more effective than developing an analytic approach to calculate the concentration from the same data set. With this in mind a neural network was created to tackle this challenge of converting the measured signal into CO2 and NH3 concentration values.

Norman, Thaddeus J.

Interplay between Ultrafast Electronic and Librational Dynamics in Liquid Nitrobenzene Probed with Two-Color Four-Wave Mixing

Here, we present an experimental and theoretical study of the interplay between ultrafast electron dynamics and librational dynamics in liquid nitrobenzene. A femtosecond ultraviolet pulse and two femtosecond near-infrared pulses interact with nitrobenzene molecules, generating a four-wave mixing nonlinear signal measured in the Optical Kerr Effect geometry. The signal is measured to be nonzero only at negative time delays, corresponding to the near-infrared pulses arriving before the ultraviolet pulse. We perform time-dependent Quantum Master Equation calculations with classical libration to simulate the experiment. The simulations support the conclusion that the near-infrared pulses launch librational motion while creating electronic coherences resulting in a libration-modulated electronic nonlinear response. The analysis of the phase-matched four-wave mixing signals suggests a nonparametric process leaving the molecules in an excited electronic state, providing new insight into ultrafast nonlinear optical interactions in liquids and advancing toward probing ultrafast electronic coherences in complex molecular liquids.

Shivaram, Niranjan [Lawrence Berkeley National Lab

Structural alignment sensor

Comparative Michelson interferometers are discussed as well as the operating range potential of a structural alignment sensor (SAS) which requires only one laser mode. Schematics are presented for the distance measurement logic, the basic SAS system, the SAS optical layout, the coarse measurement signal processor, and the measured range resolution.

Davis, L.

Digital resolver for helicopter model blade motion analysis

The paper reports the development and initial testing of a digital resolver to replace existing analog signal processing instrumentation. Radiometers, mounted directly on one of the fully articulated blades, are electrically connected through a slip ring to analog signal processing circuitry. The measured signals are periodic with azimuth angle and are resolved into harmonic components, with 0 deg over the tail. The periodic nature of the helicopter blade motion restricts the frequency content of each flapping and yaw signal to the fundamental and harmonics of the rotor rotational frequency. A minicomputer is employed to collect these data and then plot them graphically in real time. With this and other information generated by the instrumentation, a helicopter test pilot can then adjust the helicopter model's controls to achieve the desired aerodynamic test conditions.

Daniels, T. S.