Non-Nuclear Test Facility Development to Support Verification and Validation Needs

This study focuses on developing a non-nuclear test facility to help meet the verification and validation (V&V) requirements of a water-cooled small modular reactor (SMR) system. The scaling analysis necessary for reactor system experimentation and assessment model V&V considers various reactor system accident scenarios such as main steam line break (MSLB), steam generator tube rupture (SGTR), and containment condensation and heat transfer. The goal is to identify key physics based phenomena of interest (POI), specific figures of merit (FOMs), and the state of knowledge (SOK) by employing phenomena identification and ranking table (PIRT) studies. Important physics phenomena such as heat transfer, fluid dynamics, structural integrity, and material selection must be addressed when scaling a thermal-hydraulics system. Alongside these considerations, modifications to the facility may be needed to align the scaled system with the available footprint (height and space) of the facility. These modifications may include infrastructure upgrades, changes to the piping layout, implementation of safety measures, and installation of new instrumentation and control systems. The test facility aims to provide a scaled-down version of prototypic facilities for comprehensive V&V activities by overcoming these challenges and making the necessary modifications. This approach minimizes scaling distortion, simulates prototypic plant conditions, and accurately models accident event progressions. Thus, the facility will be capable of adequately modeling a scaled SMR system to support the design, development and licensing needs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fuel rod thermo-mechanic analysis of Kuosheng NPP in MSIVC transient with RELAP5 MOD3.3/Fraptran/Python code in SNAP interface

Kuosheng NPP (Nuclear Power Plant) is located on the northern coast of Taiwan. Its nuclear steam supply system (NSSS) is a type of boiling water reactor (BWR/6) designed and built by General Electric on a twin unit concept. Each unit includes two loops of recirculation piping and four main steam lines, with the thermal rated power of 2894 MWt. Unit 1 started SPU (Stretch Power Uprate) from Cycle 24 and Unit 2 started SPU from Cycle 23. The operating power is 104.7% of the OLTP (Original Licensed Thermal Power), which is 3030 MWt now. In order to estimate the safety of Kuosheng NPP, the methodology of Kuosheng NPP SPU safety analysis model was developed. This methodology is shown in Fig. 1. There are three main steps considered in this methodology. The first step is the development of the Kuosheng NPP SPU RELAP5 model. The next step is the main steam line isolation valve closure (MSIVC) analysis of Kuosheng NPP SPU RELAP5 model in order to confirm the maximum pressure of vessel below the acceptance limit of 9.58 MPa. The final step is the fuel rods integrity analysis of FRAPTRAN under the above conditions. From FRAPTRAN analysis results, we find that the peak value of cladding hoop strain is smaller than 0.01, the acceptance limit; furthermore, the fuel enthalpy values are smaller than 150 cal/g. These two results indicate that the fuel rods are still in safe condition after turbine trip accident. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of PHADEC method for the decontamination of radioactive steam piping components

The dismantling of nuclear plants is a complex activity that originates often a large quantity of radioactive contaminated residue. In this paper the attention was focused on the PHADEC (Phosphoric Acid Decontamination) plant adopted for the clearance of Caorso NPP (in Italy) metallic systems and components contaminated by Co{sup 60} (produced by the neutron capture in the iron materials), like the main steam lines, moisture separator of the turbine buildings, etc.. The PHADEC plant consists in a chemical off line treatment: the crud, deposited along the steam piping during life plant as an example, is removed by means of acid attacks in ponds coupled to a high pressure water washing. Due to the fact that the removed contaminated layers, essentially, iron oxides of various chemical composition, depend on components geometry, type of contamination and time of treatment in the PHADEC plant, it becomes of meaningful importance to suggest a procedure capable to improve the control of the PHADEC process parameters. This study aimed thus at the prediction and optimization of the mentioned treatment time in order to improve the efficiency of the plant itself and to achieve, in turn, the minimization of produced wastes. To the purpose an experimental campaign was carried out by analysing several samples, i.e. taken along the main steam piping line. Smear tests as well as metallographic analyses were carried out in order to determine respectively the radioactivity distribution and the crud composition on the inner surface of the components. Moreover the radioactivity in the crud thickness was measured. These values allowed finally to correlate the residence time in the acid attack ponds to the level of the achieved decontamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation Results of a Thermal Power Dispatch System from a Generic Pressurized Water Reactor in Normal and Abnormal Operating Conditions

Amid economic pressures in the U.S. electricity market, nuclear utilities are exploring new revenue streams, including hydrogen production. A generic pressurized water reactor simulator was modified to incorporate a novel design for a TPD system coupled to a hydrogen production plant. Standard malfunctions were included in the simulation design, including steam line breaks at various system locations and flow interruptions in the hydrogen plant due to multiple faults, reflecting anticipated operational challenges. It is imperative that the TPD system operation has a minimal effect on the reactor power, primary coolant system, and turbine system operation and performance. Due to the specific design and application of this TPD system, with the proposed turbine control system changes, the overall impact on the existing plant systems is low. Normal TPD operating scenarios resulted in minor effects on the existing plant systems: reactor power changes by at most 0.2%, and gross generator output changes by 20.5 MWe from 100 MWt of TPD. The most severe malfunction analyzed in this work is a full TPD steam line break downstream of the extraction location, which results in an increase in reactor power of about 0.5%. The gross generator output decreases by 36 MWe, a total decrease of 60 MWe from the full power steady state (FPSS) condition. These results indicate that an industrial hydrogen production plant could be coupled thermally to a nuclear power plant with limited effects on the existing system operation and safety.

08 HYDROGEN↗

A simulation of I 2 S-LWR selected transients

The Integral Inherently Safe (I 2 S-LWR) reactor was designed to improve the safety performance of PWR types reactors, and several design basis accidents were eliminated using innovative approaches to the I 2 S-LWR plant layout. However, some accidents such as station blackout (SBO), main steam line break (MSLB) type accident – the secondary hot leg break (SHLB) – were deemed statistically relevant, and the work performed here was to simulate these events using the system thermal–hydraulics code RELAP5 coupled to the 3D spatial kinetics code PARCS. The safety response of the reactor to a station blackout is predicted to be acceptable at both beginning of cycle (BOC) and end of cycle EOC core conditions with either the UO 2 or U 3 Si 2 fuel options considered here. In the analysis of the SHLB performed here, an unprotected (no SCRAM) condition was assumed to highlight the I 2 S-LWR capabilities. Results indicate that with the UO 2 core, the fuel temperatures rise notably, but no fuel melting was predicted and departure from nucleate boiling ratio (DNBR) limits were not exceeded. Similarly, the U 3 Si 2 fuel performed well, but with lower fuel temperatures and decreased DNBR. Following the break of the steam line in the I 2 S-LWR, shutdown is achieved after about two minutes via negative reactivity from loss of primary flow. In all cases considered, the I 2 S-LWR appears to accomplish the goals of increased safety performance. Further design improvements and other fuel options may marginally improve on the observed safety performance. Additionally, higher fidelity analysis with the next generation subchannel, Computational Fluid Dynamics (CFD), or full core transport may be useful in refining the prediction of the peak fuel and cladding temperatures, as well limiting DNBR during the accidents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NPP Simulators for Coupled Thermal and Electric Power Dispatch

The Light Water Reactor Sustainability (LWRS) program within the United States Department of Energy supports extending the operation of the U.S. commercial nuclear power plant (NPP) fleet. Within the LWRS program, the Flexible Plant Operation and Generation (FPOG) Pathway works to diversify the revenue streams of light water reactors (LWRs) by opening opportunities for the co-generation of non-electric products in addition to supplying electrical power to the grid. Recent events have added greater motivation to these efforts. For example, the recent Inflation Reduction Act (IRA) passed by the U.S. federal government offers substantial tax incentives for producing clean hydrogen, the technology readiness level of dispatchable and high-efficiency hydrogen production has dramatically increased in a short time, and societal response to world climate change is driving a transition away from fossil fuels. Producing hydrogen with maximum efficiency using nuclear power requires dispatching both electrical and thermal power from the nuclear plant to the hydrogen plant, so testing concepts of operations for combined electrical and thermal power dispatch (TPD) from an NNP to a hydrogen plant is of interest. This report documents achievement of the Light Water Reactor Sustainability (LWRS) program milestone “Install and demonstrate a vendor-developed simulator on the Human Systems Simulation Laboratory (HSS) for dispatch of LWR electrical power to a close-coupled electrolysis plant” with a due date of Dec. 22, 2022. Several factors provide motivation for this effort. Coupling the power generation deck of a nuclear power plant to a hydrogen production facility introduces new possibilities for operational transients that must be addressed. In particular, the performance of the integrated system during startup and shutdown of the hydrogen production facility, as well as offnormal conditions, need to be evaluated to ensure there are no adverse effects on the operation of the existing NPP. The concept of operations involving the NPP, the hydrogen plant, and the electric power grid must be tested using NPP simulators and operating procedures that have been modified for TPD operations. These tests must also include dynamic simulations of the coupled tertiary thermal and electric loads as well as coordinated activities with NPP operators, tertiary load operators and grid power coordinators. The report summarizes progress in developing and testing full-scope NPP simulators at the HSSL, including a generic BWR simulator from GSE Systems, Inc. and generic PWR simulator from Westinghouse. In the case of the TPD-GBWR Simulator from GSE Systems, Inc., a BWR is thermally coupled to a high temperature electrolysis (HTE) plant that produces hydrogen and oxygen from de-ionized water. The hydrogen plant is not explicitly simulated but only included as a transient heat sink. A thermal power dispatch (TPD) system transfers heat between the steam systems at the BWR and the hydrogen plant. Operational results from two versions of the modified simulator are presented. The first version uses synthetic oil as a heat transfer fluid in a closed delivery heat loop (DHL) that generates steam at the hydrogen plant. The second version uses steam as the heat transfer fluid in a delivery steam line (DSL) to provide steam to the hydrogen plant. For both versions, the estimated thermal power delivery distance is approximately one kilometer. The amount of thermal power dispatched in the simulators is 15% of the total reactor thermal power such that the simulators provide a tool to study the feasibility of coupling a BWR to industrial processes that benefit from a combination electrical and thermal power dispatch. Ongoing work within a CRADA is also developing a full-scope PWR simulator provided by Westinghouse for both thermal and electric power coupling. This simulator is based on a PWR plant with two three-loop Westinghouse reactors. Westinghouse PWRs are sufficiently similar that a simulator of a three-loop reactor is an appropriate representation for two-loop and four-loop PWR reactors. The three-loop simulator will initially be modified for close-coupling to a 100 MW HTE hydrogen production plant that will require approximately 25 MW of thermal power while operating at its maximum rated capacity. The simulator testing will include full coupling to dynamic simulations of a hydrogen production plant and a representative bulk electric grid. The simulator provided by Westinghouse is similar to the GPWR simulator that INL has already obtained from GSE Systems but has a few important added benefits. First, the Westinghouse simulator is based on digital controls and has additional screens that can be called up to show parameter trends to assist operators in decision-making. The Westinghouse simulator also has upgrades to the controls and hardware representations, such as valve actuators, that make it more realistic and flexible in terms of accurately sim

99 GENERAL AND MISCELLANEOUS↗

Numerical investigation of the AP1000 response following loss-of-coolant accident using PCTRAN and CFD to support R&D of SMRs

Small Modular Reactors (SMRs) present a promising solution for the future of sustainable energy, offering advantages such as reduced waste generation, advanced passive safety features, and potential cost efficiencies. Ongoing research focuses on the design and development of SMRs, addressing challenges through numerical simulations and experimental test data. Given that many next-generation reactors are first-of-a-kind (FOK), current operational reactors serve as valuable benchmarks for understanding various thermal-hydraulic phenomena during postulated design basis accidents (DBAs), including loss-of-coolant accidents (LOCA), main steam line breaks (MSLB), and steam generator tube ruptures (SGTR). This study employs the AP1000 model Personal Computer Transient Analyzer (PCTRAN) to simulate reactor responses to small-break LOCA scenarios, specifically analyzing break sizes of 2 and 10 inches. Additionally, ANSYS FLUENT software is utilized to assess containment responses to large-break LOCAs, focusing on the quantification of decay heat removal via natural convection. Verification of the PCTRAN results is achieved using Westinghouse data, with CFD results corroborating the findings. The outcomes demonstrate strong agreement with Westinghouse data, confirming the accuracy of the simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Core Status of Fukushima Daiichi Nuclear Power Plant

There were some events and phenomena that occurred which have been deemed specific to the Fukushima Daiichi NPP. The primary issues were as follows: - Direct steam leakage from the reactor pressure vessels (RPVs) to the dry-wells through the gaskets of the safety relief valves and/or due to creep damage of the main steam line, and damage of the in-core monitor guide tubes due to buckling. - Direct corium leakage from the RPVs to the pedestal floors through the melt portions of the in-core monitor housings. - Alternative water injection by the fire trucks with large amount of leakages through the branch lines. - Partial load operation of the Reactor Core Isolation Cooling system and the High Pressure Coolant Injection system. - Gas leakage from the primary containment vessels to the reactor buildings due to over pressure than the design maximum value. - Thermal stratification in the suppression pool resulting in incomplete steam condensation in the pool. The accident progressions were analyzed with the newly developed physical models for the above issues. And also considering the qualitatively estimated core status based on the plant parameters measured after the accident, the current core status was assessed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CASL COBRA-TF improvements for PWR DNB analysis

COBRA-TF (CTF) is a thermal hydraulic (T/H) subchannel code using either three-dimensional (3D) Cartesian or subchannel coordinate formulations for two-phase fluid flow and heat transfer solutions. CTF has been improved under the Consortium for Advanced Simulation of Light Water Reactors (CASL) program for Pressurized Water Reactor (PWR) applications, including software optimization, new closure models, pre- and post-processing and parallelization for modeling full reactor core T/H responses under normal operating and accident conditions. As a result of collaboration among CASL partners including the Westinghouse Electric Company, the Oak Ridge National Laboratory (ORNL), and the Sandia National Laboratories, additional modeling improvements were made to CTF specifically for PWR Departure from Nucleate Boiling (DNB) analysis, including a code option to evaluate fuel thermal margin in terms of DNB Ratio (DNBR) and an axial shape factor to account for effect of non-uniform axial power distribution on DNB. Multiple DNB correlations are now linked with CTF for different applications, including the Westinghouse proprietary WRB-1 correlation for fuel designs containing mixing vane grid spacers. The improved CTF code with the WRB-1 correlation (CTF/WRB-1) was validated using the DNB data from the PWR Subchannel Bundle Tests (PSBT). In addition to the comparison with the test data, the CTF/WRB-1 DNBR results and the associated local fluid conditions were compared to the results of the Westinghouse T/H design code, VIPRE-W, which is an enhanced version of the VIPRE-01 code originally developed by the Electric Power Research Institute (EPRI). The comparisons showed that CTF/WRB-1 DNBR predictions are in good agreement with the VIPRE-W results within the applicable range of the DNB correlation. A model sensitivity study was performed to confirm that the CTF void drift model had an insignificant effect on DNBR under the steam line break (SLB) low pressure condition. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantification of functional impact classification on the current U.S. nuclear fleet

Currently, nuclear power generates only a small fraction of the world's electricity, though it does have the potential to meet the needs of the world as long as its production can compete with the alternative energy base load producers. In U.S the commercial nuclear fleet comprises of Light Water Reactors (LWRs), consisting of Pressurized Water Reactors (PWRs) and Boiling Water Reactors (BWRs). Many plants experience multiple events each year, which lead to reactor trips or scrams. This subsequently leads to plants being off the grid, which is not an economically favorable situation in the current energy markets. This study helps identify functional impact (FI) event categories for both PWR's and BWR's. Understanding that not all events and their causes can be anticipated, current industry best practices implement lessons learned to provide challenges and issues identification. In turn these are studied to achieve improved operational practices, and design modifications. This leads to overall enhanced resiliency. FI groups are the categories of initiating events (IE). IEs are unplanned events that occur while a nuclear plant is in critical operation, and requires that the plant be shut down to achieve a stable state. When a risk cannot be eliminated, IEs are identified and studied to reduce the risk and contribute to the identification of mitigations, safer designs and operational practices. Breaking IE events into groups' results in the classification of FI groups. A FI group is a risk-significant event category that could impact the ability of a NPP to remove decay heat from the reactor. Inability to remove decay heat from the reactor has the potential to lead to core damage. For an event to be considered a FI, it must be associated with a manual or automatic reactor trip, irrespective of the order of events. In addition, the plant must be at or above the point of adding heat and the event must happen before or shortly after a reactor trip. One or more FIs may be identified in any individual reactor trip sequence. The relationship between FI sequence, and/or frequency per a plant event is outside the scope of this paper. For example, the loss of offsite power (LOOP) can occur from eternal events (i.e. weather, human, wildlife etc.). This results in an event that requires a transfer of power to an emergency source, such as a generator, which produces a reactor trip and then a closure of main steam isolation valves (MSIVS). The FI applicable to this reactor trip sequence would be LOOP and closure of at least one MSIV in each main steam line. The results presented herein are focused on the analysis and evaluation of FI event categories. Only FI categories that can be found in IE studies, Initialing Events Spreadsheet and are recorded in a historical review of Licensee Event Reports (LERs) from 1988 through 2013. The results of this analysis can support plant decisions, design, procedures, and identify weakness.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Risk-Informed Analysis of Accidents at Reactor Facilities with VVER

An accident with ‘rupture of steam line’ as the initial event was studied for a reactor facility with VVER-1000. A computational analysis was performed of different flow scenarios of an accident with singular and multiple failures of the safety systems. The realization probability and the consequences were evaluated for each accident sequence. The consequences of the accidents are ranked and the most instructive combinations of failures of systems and blockings are determined from the standpoint of risk. The presented method is based on multivariate calculations and an integrated combination of deterministic and probabilistic approaches to safety validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Olkiluoto 1 and 2 - Plant efficiency improvement and lifetime extension-project (PELE) implemented during outages 2010 and 2011

Teollisuuden Voima Oyj (TVO) is a non-listed public company founded in 1969 to produce electricity for its stakeholders. TVO is the operator of the Olkiluoto nuclear power plant. TVO follows the principle of continuous improvement in the operation and maintenance of the Olkiluoto plant units. The PELE project (Plant Efficiency Improvement and Lifetime Extension), mainly completed during the annual outages in 2010 and 2011, and forms one part of the systematic development of Olkiluoto units. TVO maintains a long-term development program that aims at systematically modernizing the plant unit systems and equipment based on the latest technology. According to the program, the Olkiluoto 1 and Olkiluoto 2 plant units are constantly renovated with the intention of keeping them safe and reliable, The aim of the modernization projects is to improve the safety, reliability, and performance of the plant units. PELE project at Olkiluoto 1 was done in 2010 and at Olkiluoto 2 in 2011. The outage length of Olkiluoto 1 was 26 d 12 h 4 min and Olkiluoto 2 outage length was 28 d 23 h 46 min. (Normal service-outage is about 14 days including refueling and refueling-outage length is about seven days. See figure 1) The PELE project consisted of several single projects collected into one for coordinated project management. Some of the main projects were as follows: - Low pressure turbines: rotor, stator vane, casing and turbine instrumentation replacement. - Replacement of Condenser Cooling Water (later called seawater pumps) pumps - Replacement of inner isolation valves on the main steam lines. - Generator and the generator cooling system replacement. - Low voltage switchgear replacement. This project will continue during future outages. PELE was a success. 100 TVO employees and 1500 subcontractor employees participated in the project. The execution of the PELE projects went extremely well during the outages. The replacement of the low pressure turbines and seawater pumps improved the efficiency of the plant units, and a power increase of nearly 20 MW was achieved at both plant units. PELE wonderfully manifests one of the strategic goals of our company; developing the competence of our in-house personnel by working in projects. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Flow Accelerated Erosion-Corrosion (FAC) considerations for secondary side piping in the AP1000{sup R} nuclear power plant design

The issue of Flow Accelerated Erosion-Corrosion (FAC) in power plant piping is a known phenomenon that has resulted in material replacements and plant accidents in operating power plants. Therefore, it is important for FAC resistance to be considered in the design of new nuclear power plants. This paper describes the design considerations related to FAC that were used to develop a safe and robust AP1000{sup R} plant secondary side piping design. The primary FAC influencing factors include: - Fluid Temperature - Pipe Geometry/layout - Fluid Chemistry - Fluid Velocity - Pipe Material Composition - Moisture Content (in steam lines) Due to the unknowns related to the relative impact of the influencing factors and the complexities of the interactions between these factors, it is difficult to accurately predict the expected wear rate in a given piping segment in a new plant. This paper provides: - a description of FAC and the factors that influence the FAC degradation rate, - an assessment of the level of FAC resistance of AP1000{sup R} secondary side system piping, - an explanation of options to increase FAC resistance and associated benefits/cost, - discussion of development of a tool for predicting FAC degradation rate in new nuclear power plants. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characteristics of Axial Power Shape and Flow Field at Low Flow Condition

The representative event which experiences the low flow condition is SLB (Steam Line Break) event. During the SLB event with LOOP (Loss of Offsite Power), the reactor core is tripped and all RCPs (Reactor Coolant Pump) are stopped. The biggest worth control rod also stuck out. As a result, the flow rate and pressure in reactor core decrease and the peaking factor is relatively high compared to a nominal operating condition. In this paper, we study the tendency of the core axial power distribution and flow field with respect to the core average power at the SLB accident condition. Generally, the condition has been analyzed using the neutronics code with one dimensional flow result of the assemblies. However, if the core average power increases, the coolant density in the hot channel decreases and mass flux increases. The assumption that the mass flux is constant at the one dimensional analysis is incorrect. Hence, it is needed to couple the neutronics code and the subchannel analysis code in order to give feedback to neutronics code with the 3-D flow information. In this study, we coupled the nuclear design code and the subchannel analysis code and showed the characteristics of the axial power distribution and the flow field at the low flow condition. Since there is no experimental data at the condition, the characteristics of the power distribution and flow field were analyzed to understand the physical phenomena. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

QUANTIFICATION OF FUNCTIONAL IMPACT CLASSIFICATION ON THE CURRENT US NUCLEAR FLEET

Many plants experience multiple failure events each year, and while none of these events result in core damage further consideration for nuclear power plant (NPP) type and its role in an event needs to be considered. Specifically herein initiating events (IE) are considered these are unplanned events that occur while a nuclear plant is in critical operation, and requires that the plant be shut down to achieve a stable state. Breaking IE failure events into groups results in the classification of functional impact (FI) groups. A FI group is a risk-significant event category that could impact the ability of a NPP to remove decay heat from the reactor. For an event to be considered a FI, it must be associated with a manual or automatic reactor trip, irrespective of the order of events. In addition, the plant must be at or above the point of adding heat and the event must happen before or shortly after a reactor trip. One or more FIs may be identified in any individual reactor trip sequence. An example of a FIs is the loss of offsite power (LOOP) from a bird interaction with the power lines. This results in a failure to transfer power to an emergency source, such as a generator, producing a turbine and reactor trip and then a closure of main steam isolation valves (MSIVS). The FI applicable to this reactor trip sequence would be loss of offsite power and closure of at least one MSIV in each main steam line. The results presented are focused on the analysis and evaluation of FI event categories that can be found in IE studies [1], [2] and the Initialing Events Spreadsheet [3] and is a historical review of Licensee.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Feedwater temperature control methods and systems

A system for controlling the power level of a natural circulation boiling water nuclear reactor (NCBWR) is disclosed. The system, in accordance with an example embodiment of the present invention, may include a controller configured to control a power output level of the NCBWR by controlling a heating subsystem to adjust a temperature of feedwater flowing into an annulus of the NCBWR. The heating subsystem may include a steam diversion line configured to receive steam generated by a core of the NCBWR and a steam bypass valve configured to receive commands from the controller to control a flow of the steam in the steam diversion line, wherein the steam received by the steam diversion line has not passed through a turbine. Additional embodiments of the invention may include a feedwater bypass valve for controlling an amount of flow of the feedwater through a heater bypass line to the annulus.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Towards a Consolidated Approach for the Assessment of Evaluation Models of Nuclear Power Reactors

The STARS project at the Paul Scherrer Institut (PSI) has adopted the TRACE thermal-hydraulic (T-H) code for best-estimate system transient simulations of the Swiss Light Water Reactors (LWRs). For analyses involving interactions between system and core, a coupling of TRACE with the SIMULATE-3K (S3K) LWR core simulator has also been developed. In this configuration, the TRACE code and associated nuclear power reactor simulation models play a central role to achieve a comprehensive safety analysis capability. Thus, efforts have now been undertaken to consolidate the validation strategy by implementing a more rigorous and structured assessment approach for TRACE applications involving either only system T-H evaluations or requiring interfaces to e.g. detailed core or fuel behavior models. The first part of this paper presents the preliminary concepts of this validation strategy. The principle is to systematically track the evolution of a given set of predicted physical Quantities of Interest (QoIs) over a multidimensional parametric space where each of the dimensions represent the evolution of specific analysis aspects, including e.g. code version, transient specific simulation methodology and model "nodalisation". If properly set up, such environment should provide code developers and code users with persistent (less affected by user effect) and quantified information (sensitivity of QoIs) on the applicability of a simulation scheme (codes, input models, methodology) for steady state and transient analysis of full LWR systems. Through this, for each given transient/accident, critical paths of the validation process can be identified that could then translate into defining reference schemes to be applied for downstream predictive simulations. In order to illustrate this approach, the second part of this paper presents a first application of this validation strategy to an inadvertent blowdown event that occurred in a Swiss BWR/6. The transient was initiated by the spurious actuation of the Automatic Depressurization System (ADS). The validation approach progresses through a number of dimensions here: First, the same BWR system simulation model is assessed for different versions of the TRACE code, up to the most recent one. The second dimension is the "nodalisation" dimension, where changes to the input model are assessed. The third dimension is the "methodology" dimension. In this case imposed power and an updated TRACE core model are investigated. For each step in each validation dimension, a common set of QoIs are investigated. For the steady-state results, these include fuel temperatures distributions. For the transient part of the present study, the evaluated QoIs include the system pressure evolution and water carry-over into the steam line.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗