Search NASA⌕ Search

SEARCH · Search NASA

Results for “SUBCOOLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Preliminary Thermal-Hydraulic Analysis of the UTA–2 Subcritical Linear Accelerator–Driven System

The National Nuclear Security Administration’s mission includes establishing a reliable supply of 99 Mo without highly enriched uranium. Oak Ridge National Laboratory (ORNL) supports this objective through collaborative research and development with industrial partners. Niowave Inc., a current partner, is currently designing a subcritical linear accelerator-driven system (ADS) and preparing for the US Nuclear Regulatory Commission’s licensing process. Niowave’s system has the potential to efficiently supply medical radioisotopes. The technology includes a superconducting electron accelerator and a pile of both natural and low-enriched uranium (LEU) targets. The process fissions uranium and many valuable isotopes can then be extracted from the targets. Niowave is currently iterating through conceptual and detailed design processes for several system sizes. This report discusses UTA–2, which is at the demonstration stage. UTA–2 will validate numerical modeling results with experimental measurements before progressing to the detailed design of UTA–3, the commercial-sized ADS. The thermal-hydraulic behavior of the UTA–2 core design was numerically investigated using STAR-CCM+, as described in this report. STAR-CCM+, a state-of-the-art computational fluid dynamics (CFD) software that was commercially developed by Siemens, has an extensive user base and a set of validation studies. It is also compliant with the American Society of Mechanical Engineers’ Nuclear Quality Assurance 1 standard. Three cases are investigated in this report. Case 1 quantified the temperature field within the UTA–2 assembly and water tank using only conduction as the method of thermal energy transport. This simplified approach was overly conservative and yielded wetted cladding temperatures above the coolant saturation temperature. In this case, the maximum temperature of the wetted cladding surface of the highest power rod exceeded the saturation temperature of water by 63.8°C. Because of the overly conservative approach taken in Case 1 and its negative subcooled margin, buoyancy-driven natural circulation flow physics were implemented in Case 2. Adding coolant motion significantly distributed the thermal energy of the system through convective heat transfer. This relatively small amount of convective heat transfer significantly reduced system temperatures and increased the subcooled margin from –63.8 to 61.3°C. This margin confirmed that no boiling was expected during normal operation of UTA–2 at 230 W. Case 3 had no additional physics models but considered an overpower event during which the power of each LEU and natural uranium rod was at its respective peak values. This resulted in a study with the total assembly power equal to 176% of the nominal power of 230 W considered in Cases 1 and 2. The resulting natural circulation flows were slightly enhanced. The subcooled margin decreased slightly to 46.3°C, which is still a significant margin to local boiling of the water within the tank. This margin confirmed that no boiling was expected during an abnormal operation of UTA–2 at 406 W.

07 ISOTOPE AND RADIATION SOURCES↗

Recent progresses on thermal–hydraulics evaluations of accident tolerant fuel cladding materials

Thermal–hydraulics (T-H) experiments have been on the progress to evaluate boiling heat transfer characteristics of accident tolerant fuel (ATF) candidates for further supporting the core-loading of these advanced ATF concepts in light water reactors (LWRs). Here this study covers recent experimental studies of ATF claddings and summarizes some significant results. Recent T-H experimental results of ATF cladding candidates demonstrated that the material thermal–physical properties have pronounced effects on critical heat flux (CHF). Such effects have not been well resolved in the current physics-governing models. These effects of cladding materials on CHF could be potentially rationalized by the material-conjugated boiling heat transfer, where the material-dominated heat conduction competes with the flow boiling-dominated heat convection. As progressively increasing the mass flux and/or liquid subcooling, CHF differences between different materials gradually decrease, which is in agreement with the recent T-H experimental results of ATF claddings. This is because the dominance of heat convection over heat conduction is primarily improved by liquid subcooling and/or mass flow rate. It is noteworthy that surface oxidization of claddings may have unknown impacts on T-H performances because the formation of oxide layers on cladding surfaces introduces variations of material thermal–physical properties and then changes the surface morphological features, which results in some difficulties in evaluating the thermal safety margins of ATF claddings.

36 MATERIALS SCIENCE↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Experimental study for critical heat flux in 2x2 rod bundles at high pressure conditions

Critical heat flux (CHF) phenomena has been a topic of study for over fifty years yet remains a serious concern across industries and especially in water-cooled nuclear reactor design. CHF data in the high-pressure range is limited, and the effects of bundle geometry and non-uniform heat flux profile are challenging to quantify. In this study, CHF experiments were performed in upward flowing water in a 2 × 2 rod bundle with a cosine profile heat flux. Data were collected between 16.5 and 18 MPa at two mass flux conditions with three inlet subcooling conditions. Under these conditions, average CHF was shown to decrease with increasing pressure. However, pressure had less of an effect than decreasing the inlet subcooling or the mass flux, both of which reduce the CHF value considerably. Of interest, correlations that have been developed for lower pressure continued to predict CHF occurrences with moderate accuracy outside their ranges of validity. Nearly all predicted values were within 20% of experimental values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-phase flow measurements and observations in a cooling panel of the reactor cavity cooling system

The analysis of the flow behavior within a cooling panel of a scaled water-cooled reactor cavity cooling system has been performed supported by high-resolution measurements of the void fraction at the risers’ outlet. The results have shown a stable, symmetric distribution of the flow through the risers during subcooled boiling conditions, characterized by small, slow bubbles with average void fraction lower than 0.3 for all risers. As the temperature increased to saturation, flow distribution appeared strongly asymmetrical and unstable, with peaks of void fraction as high as 0.9. Large, faster bubbles were observed during these peaks, immediately followed by flow of subcooled liquid water. Flow stagnation and inversion has also been observed. The high resolution void fraction results, complemented by the measurements of the coolant flow rate and temperatures, not only have further described the behavior of the system under hypothetical accident conditions, but represent a unique set of data to support the validation of system-level codes, and more advanced computational tools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Power Generation Cycle with RELAP-7

Balance of plant of a High-Temperature gas-cooled Reactor – Pebble bed Module (HTR-PM) is modeled using RELAP-7. The model includes the primary helium loop where the heat produced by the core is transferred to a helical-coil steam generator and the secondary loop where super-heated steam is fed to a turbine to extract power. The steam is then condensed to subcooled water and pumped back into the steam generator. Results demonstrate that RELAP-7 has the capability to model different regimes encountered in two-phase flow with wall boiling, superheated steam, subcooled liquid and condensation. RELAP-7 also has the capability of modeling different fluids with their own specific models in a very flexible way, without any code change. This also demonstrates the capability of modeling the transfer of fission power into electrical power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultra efficient turbo-compression cooling systems

Aspects of the present disclosure include a system for turbo-compression cooling. The system may be aboard a marine vessel. The system includes a power cycle and a cooling cycle. The power cycle includes a first working fluid, a waste heat boiler configured to evaporate the working fluid, a turbine, and a condenser. The condenser condenses the working fluid to a saturated or subcooled liquid. The cooling cycle includes a second working fluid, a first compressor configured to increase the pressure of the second working fluid, a condenser configured to condense the second working fluid to a saturated or subcooled liquid after exiting the first compressor, an expansion valve, and an evaporator. The turbine and first compressor are coupled one to the other. The waste heat boiler receives waste heat from engine jacket water and lubricating oil from a ship service generator. The evaporator cools water in a shipboard cooling loop.

Bandhauer, Todd M.↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A non-intrusive framework using acoustic signals and deep learning for boiling diagnostics in visual-limited environments

Accurate monitoring of boiling heat transfer is critical for safeguarding high-power systems operating in environments where conventional optical diagnostics are hindered by radiation fields or restricted visual accessibility. This study presents a non-intrusive framework that integrates hydroacoustic sensing with deep learning to infer near-wall boiling characteristics and enable predictive thermal assessment without visual access. In a prototypical subcooled flow-boiling facility representative of the Isotope Production Facility (IPF) at Los Alamos, hydrophones capture boiling-induced acoustic emissions that are transformed into background-removed Short-Time Fourier Transform (STFT) spectrograms. A convolutional neural network (CNN) then regresses heat flux, wall superheat, and key bubble parameters directly from these spectrograms. The CNN achieved predictive accuracy under nominal conditions and demonstrated robustness and generalization under acoustic noise for Signal-to-Noise Ratios (SNRs) down to approximately 0 dB. When integrated into an ANSYS CFX wall-boiling model, the acoustically inferred parameters reproduced boiling curve and critical heat flux (CHF) values consistent with image-based benchmarks. Furthermore, the model retained reliable performance under moderate variations in bulk temperature, flow rate, and hydrophone placement, confirming its generalizability across practical boundary conditions. These results demonstrate the feasibility of hydroacoustic-based deep learning as a viable path toward real-time, radiation-tolerant boiling diagnostics and predictive thermal safety assessment in inaccessible systems such as the IPF.

42 ENGINEERING↗

Comparison of Model Predictions and Performance Test Data for a Prototype Thermal Energy Storage Module

Although model predictions of thermal energy storage (TES) performance have been explored in previous investigations, relevant test data that enable experimental validation of performance models have been limited. This is particularly true for high-performance TES designs that facilitate fast input and extraction of energy. In this paper, we present a summary of experimental tests of a high-performance TES unit using lithium nitrate trihydrate phase change material as a storage medium. Performance data are presented for complete dual-mode cycles consisting of extraction (melting) followed by charging (freezing). These tests simulate the cyclic operation of a TES unit for asynchronous cooling in a variety of applications. Finally, the model analysis is found to agree reasonably well, within 10%, with the experimental data except for conditions very near the initiation of freezing, a consequence of subcooling that is required to initiate solidification.

25 ENERGY STORAGE↗

Achievements and Ongoing Challenges for advanced CFD Boiling Closure Model Development using Physical Insights from Validation-Oriented High-Fidelity Boiling Experiment

The fundamental understanding of the boiling-associated heat transfer, including sliding bubble effect, is still challenging despite the intensive research for decades in both experimental and computational boiling research communities. One of the main difficulties of boiling experiment come from the fact that direct observation of the underlying principle through experiment is very difficult due to the high complexity of the boiling phenomenon. Also, since the heat transfer characteristics associated with boiling is the result of non-linear interaction of various physical parameters coupled to each other, it is challenging to find the relationship between the parameters for modeling. This paper discusses the authors’ past and ongoing boiling research under CASL (Consortium for Advanced Simulation of Light Water Reactors) program, including the efforts to overcome the difficulties of boiling measurement and model development. In particular, we focus on describing the major achievements, lessons learnt, and ongoing challenges for the CFD boiling closure model development based on the high-fidelity subcooled flow boiling experiment at Texas A&M University (TAMU). The major research achievements discussed through this paper include (i) novel boiling measurement strategy and high-fidelity validation data production, (ii) dedicated effort to identify the critical measurement issues in boiling experiment, (iii) new physical insight into sliding bubble heat transfer mechanisms, and (iv) new boiling closure model development. Discussion is also made on the ongoing challenges for the boiling closure model development and the future research plan based on the lessons learnt.

42 ENGINEERING↗

Pressurizer dynamic model and emulated programmable logic controllers for nuclear power plants cybersecurity investigations

This work demonstrates the functionality of the pressurizer using a fast-running three regions, non-equilibrium model and control programs of emulated PLCs. The state variables from an integrated model of primary loop in a representative PWR plant are communicated to the pressurizer’s emulated PLCs using a synchronized data transfer function. In turn, the PLCs communicate back instructions to the pressurizer model to adjust the pressure and water level to remain within preprogramed setpoints. Pressurizer model simultaneously solves the coupled mass and energy conservation equations in the saturated vapor and saturated and subcooled liquid regions using fixed step solver. Results demonstrate the response of the pressurizer model linked to an emulated pressure and water level PLCs in a simulated transient involving surge-in and surge-out events. The 50 ms response delay time for the emulated PLC insignificantly affects operation and predictions of the pressurizer model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Performance evaluation of a wrapped around condenser for heat pump water heater applications

In this report, accurate performance evaluation of a wrapped-around condenser for heat pump water heaters (WHPWH) is critical since the COP of the system depends heavily on thermal stratification and condenser design. An analytical, quasi-steady state heat balance method has been developed to determine the optimal spacing between adjacent channels, tube diameter, tube shape, and total refrigerant charge amount for the condenser. The heat transfer rate is compared among three approaches: the refrigerant thermodynamic model, the condenser-wrap fin model, and the analytical natural convection model on the inside of the tank for the three regions based on the refrigerant phase (e.g., super-heated, saturated, or subcooled). The heat transfer rate was predicted by a combination of slug-plug and annular flow for a D-shaped helical tube. Experimental data were used as boundary conditions for validating the model. The rate of heat transfer based on tube shape and tank wall temperatures was compared by CFD analysis. Parametric analysis indicates a tradeoff between refrigerant mass, pressure drop, tube diameter, and tube length to maximize the heat transfer rate. The model suggests the saturated region length can be extended by 400%, and the condenser pressure drop can be reduced by 23% with an optimal spacing pattern.

42 ENGINEERING↗

Critical heat flux on zircaloy and accident tolerant fuel cladding under prototypical conditions of pressurized and boiling water reactors

First of a kind high spatial and temporal resolution temperature measurements of Pressurized Water Reactor and Boiling Water Reactor simulated fuel pins (high heat flux cosine profile heaters) in annular rod type geometry during nucleate boiling, departure from nucleate boiling and re-wetting has been performed. Distributed fiber optic measurements of the cladding axial temperature with spatial resolutions down to 2.5 mm axially at up to three equally spaced azimuthal locations per rod have demonstrated the similarities and differences of the different accident tolerant fuel cladding materials. These experiments show the performance of accident tolerant cladding with a precise measurement of the location and evolution of dryout followed by the re-wetting phenomena (see supplementary time history of a critical heat flux event). Experimental parameters varied coolant mass fluxes from 1695 to 2712 kg/m 2 s, pressures from 10 to 20 MPa, and inlet subcooling from 10 to 55 °C. It was found that the coatings and different material have little effect on the value of the critical heat flux. Any discrepancies between the local critical heat flux verified among the cladding material are attributed to different departure from nucleate boiling phenomena captured during the experiment with the high-resolution optical fiber temperature data. Substantial differences in the performance of the different cladding material to survive a critical heat flux event were however observed by post-test X-ray and optical inspection. External evident damage and internal cracks to the simulated fuel pin having the bare zircaloy cladding were observed in regions associated with the occurrence of the critical heat flux for longer periods. Such damages were associated with zirconium oxidation, and not noticed on the Cr coated zircaloy or FeCrAl claddings. These results indicate that the use of FeCrAl or a Cr coated zircaloy as cladding in Pressurized Water Reactor and Boiling Water Reactor may increase the survivability of the cladding material for short transients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗