Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy is a relatively new but very powerful technique for obtaining several metrological parameters at nanometer range spatial resolution. It is logical to think deploying it into space applications like diagnostics of protein crystal growth under microgravity conditions. One may attempt to deploy existing instrumentation and expect some results. However, the existing technology and commercial instrumentation is tailored to ground based laboratory situations. Even in those laboratory conditions, the role of fluids (common in crystal growth), rough objects (such as a crystal under growth), etc. on the instrumentation is only recently being investigated. These aspects combined with effects of reduced gravity environment are going to make the problem more complex. These technological challenges must be tackled for meaningful system operation in space. Since the microscopy concept has not been attempted so far in space, all of the actual problems are unknown. Nevertheless, based on current literature, some possible problems and potential solutions are described here. One may use the discussion for system modification/optimization during initial use of this kind of microscopy in space.

Vikram, C. S.↗

Scanning Tunneling Microscopy methods for spectroscopic imaging of subsurface interfaces

A new method for spatially-resolved, spectroscopic investigation of subsurface interface structure has been developed. The method, Ballistic Electron Emission Microscopy (BEEM), is based on Scanning Tunneling Microscopy (STM) techniques. BEEM combines STM vacuum tunneling with unique ballistic electron spectroscopy capabilities. BEEM enables, for the first time, direct imaging of subsurface interface electronic properties with nanometer spatial resolution. STM topographic images of surface structure and BEEM images of subsurface properties are obtained simultaneously. BEEM capabilities are demonstrated by investigation of important metal-semiconductor interfaces.

Bell, L. D.↗

Experimental and analytical study of fatigue damage in notched graphite/epoxy laminates

Both tension and compression fatigue behaviors were investigated in four notched graphite/epoxy laminates. After fatigue loading, specimens were examined for damage type and location using visual inspection, light microscopy, scanning electron microscopy, ultrasonic C-scans, and X-radiography. Delamination and ply cracking were found to be the dominant types of fatigue damage. In general, ply cracks did not propagate into adjacent plies of differing fiber orientation. To help understand the varied fatigue observations, the interlaminar stress distribution was calculated with finite element analysis for the regions around the hole and along the straight free edge. Comparison of observed delamination locations with the calculated stresses indicated that both interlaminar shear and peel stresses must be considered when predicting delamination. The effects of the fatigue cycling on residual strength and stiffness were measured for some specimens of each laminate type. Fatigue loading generally caused only small stiffness losses. In all cases, residual strengths were greater than or equal to the virgin strengths.

Whitcomb, J. D.↗

Experimental and analytical study of fatigue damage in notched graphite/epoxy laminates

Fatigue damage development in notched graphite/epoxy laminates is investigated in both compression and tension, with tested specimens being examined for damage type and location using light microscopy, scanning electron microscopy, ultrasonic C-scans, and X-radiography. Delamination and ply cracking were found to be the dominant types of fatigue damage. Comparison of observed delamination locations with finite element calculations indicates that both interlaminar shear and peel stresses must be considered when predicting delamination. Fatigue loading generally caused only small stiffness losses, and residual strengths were in all cases greater than, or equal to, the virgin strengths.

Whitcomb, J. D.↗

Scanning electron microscopy of the vestibular end organs

The vestibular end organs, after chemical fixation, were freeze dried, coated with gold and palladium, and studied in the scanning microscope. Scanning microscopy gives a good three dimensional view of the sensory areas and allows study of both gross anatomy and microstructures. Cross anatomical features of the structure of the ampullae are demonstrated. The form of the statoconia in different species of animals is shown. New aspects of the structure of the sensory hairs are revealed. The hair bundles in the central areas of the cristae and in the striola of the maculae differ structurally from the hair bundles at the periphery of the sensory regions. Furthermore, some hair bundles consisting of very short stereocilia were observed. The relationship between the cupula and the statoconial membrane to the epithelial surface is discussed.

Lindeman, H. H.↗

Scanning electron microscopy of lunar regolith from the Sea of Fertility

Scanning electron microscopy was used in studying the morphology and cathodoluminescence of lunar regolith particles. Surface and structure of two groups of particles are differentiated: (1) Crystalline with well defined facets and spalling surfaces, which are grains of minerals and rock fragments: and (2) amorphous, fused, and partially or entirely glazed particles. Local melting of particles and the round openings on their surfaces are attributed to secondary influence on the regolith of factors of lunar weathering and above all micrometeoric impacts.

Antoshin, M. K.↗

Investigation of KC-135 flight samples solidified in near-zero gravity

An analysis was conducted of three KC-135 flight samples that had been solidified in near-zero gravity. These samples had been generated during near-zero gravity testing of M553 experiment Skylab flight hardware. The samples evaluated were all Star-J Satellite, a cobalt base alloy. The analytical procedures (optical microscopy, scanning electron microscopy, electron microprobe, X-ray diffraction, differential scanning calorimetry, and microhardness) to be use on the Skylab flight samples were optimized and the analytical results are presented.

Larson, D., Jr.↗

Endolithic algae and micrite envelope formation in Bahamian oolites as revealed by scanning electron microscopy.

Examination of Holocene Bahamian ooelites by scanning electron and light microscopy has revealed the morphology and orientation of aragonite crystals in the lamellar ooelitic envelope, and their modification by the boring activities of endolithic algae. The voids produced by these algae are found in progressive stages of being lined and filled with precipitated microcrystalline aragonite, which is similar to the process of micrite envelope formation in molluscan and other skeletal carbonate grains.

Margolis, S.↗

Scanning tunneling microscopy studies of diamond films and optoelectronic materials

In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.

Perez, Jose M.↗

Application of Laser Scanning Confocal Microscopy to Heat and Mass Transport Modeling in Porous Microstructures

Laser Scanning Confocal Microscopy (LSCM) has been used to obtain digital images of the complicated 3-D (three-dimensional) microstructures of rigid, fibrous thermal protection system (TPS) materials. These orthotropic materials are comprised of refractory ceramic fibers with diameters in the range of 1 to 10 microns and have open porosities of 0.8 or more. Algorithms are being constructed to extract quantitative microstructural information from the digital data so that it may be applied to specific heat and mass transport modeling efforts; such information includes, for example, the solid and pore volume fractions, the internal surface area per volume, fiber diameter distributions, and fiber orientation distributions. This type of information is difficult to obtain in general, yet it is directly relevant to many computational efforts which seek to model macroscopic thermophysical phenomena in terms of microscopic mechanisms or interactions. Two such computational efforts for fibrous TPS materials are: i) the calculation of radiative transport properties; ii) the modeling of gas permeabilities.

Marshall, Jochen↗

Methods of analyzing microsize particulate aerosols and contaminants.

Methods for analyzing atmospheric aerosols and particulate contaminants from natural and industrial sources are briefly described. Their development was spurred by interest in cosmic dust investigations. These methods make it possible to analyze individual particles ranging in size from 0.01 to 1000 microns for elemental and mineralogical content. The described methods include transmission electron microscopy, scanning electron microscopy, electron probe microanalysis, X-ray diffraction, optical mineralogy, and density measurement.

Blanchard, M. B.↗

Chemistry and surface morphology of soil particles from Luna 20 LRL sample 22003.

Optical and scanning electron microscopy, scanning electron microprobes and energy dispersion techniques were applied in an analysis of six siliceous glass spheres, five siliceous glass-bonded agglutinates and one breccia fragment from Luna 20 sample 22003. It is theorized that local meteor impact processes might have been responsible for the formation of most of the glass spheres and that the impacts of relatively high velocity particles might have been responsible for the craters observed on the surfaces of the spheres. The concentrations of iron spherules on the surfaces of the glass spheres were generally lower than in similar Apollo 11 and 12 glass spheres.

Carter, J. L.↗

Survey of probable micrometer-sized Earth-orbital debris fragments in the NASA-JSC cosmic dust sample collection

A program to collect extraterrestrial dust samples from the stratosphere using impactors mounted on NASA U-2 and WB-57F aircraft is discussed. Sample collection, preparation, and analysis techniques are described and the particle types found are reviewed. Preliminary examination of the particles indicates that they represent not only extraterrestrial material, but some fraction of terrestrial contamination from both natural and manmade sources. This examination involves a combination of optical microscopy, scanning electron microscopy (SEM) and qualitative bulk elemental analysis using an energy-dispersive X-ray spectrometer (EDS) to characterize each particle. The cosmic dust collection contains samples of at least three classes of material that may present some hazard to extended spacecraft operations in near-Earth orbit: (1) micrometeorites/cosmic dust, (2) aluminum oxide spheres, and (3) alloy spherules and fragments.

Clanton, U. S.↗