Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

How Precisely Can Individual Molecules Be Analyzed? A Case Study on Locally Quantifying Forces and Energies Using Scanning Probe Microscopy

Recent advances in scanning probe microscopy methodology have enabled the measurement of tip-sample interactions with picometer accuracy in all three spatial dimensions, thereby providing a detailed site-specific and distance-dependent picture of the related properties. This paper explores the degree of detail and accuracy that can be achieved in locally quantifying probe-molecule interaction forces and energies for adsorbed molecules. Toward this end, cobalt phthalocyanine (CoPc), a promising CO 2 reduction catalyst, was studied on Ag(111) as a model system using low-temperature, ultrahigh vacuum noncontact atomic force microscopy. Data were recorded as a function of distance from the surface, from which detailed three-dimensional maps of the molecule's interaction with the tip for normal and lateral forces as well as the tip-molecule interaction potential were constructed. The data were collected with a CO molecule at the tip apex, which enabled a detailed visualization of the atomic structure. Determination of the tip-substrate interaction as a function of distance allowed isolation of the molecule-tip interactions; when analyzing these in terms of a Lennard-Jones-type potential, the atomically resolved equilibrium interaction energies between the CO tethered to the tip and the CoPc molecule could be recovered. Interaction energies peaked at less than 160 meV, indicating a physisorption interaction. As expected, the interaction was weakest at the aromatic hydrogens around the periphery of the molecule and strongest surrounding the metal center. In conclusion, the interaction, however, did not peak directly above the Co atom but rather in pockets surrounding it.

36 MATERIALS SCIENCE↗

Colocalized Raman spectroscopy – scanning electrochemical microscopy investigation of redox flow battery dialkoxybenzene redoxmer degradation pathways

Non-aqueous redox flow batteries offer high voltages for grid-level energy storage technologies. However, decomposition of the redoxmers - redox-active molecules that make up the anolyte and catholyte in the negative and positive cell compartments - is an important challenge to overcome for long-term storage. Here, we present a spectroelectrochemical study of the catholyte candidate 2,3-dimethyl-1,4-dialkoxybenzene (C7) and its decomposition mechanisms in the presence of a model nucleophilic base, pyridine. We utilize colocalized Raman microscopy and scanning electrochemical microscopy (Raman-SECM) to quantify the chemical rates of decom-position and qualitatively identify the reaction intermediates and products. A detailed study on how the Raman-SECM parameters (electrode distance, substrate electrode, and laser focal height) influence the Raman signal of the charged catholyte C7 ∙+ is presented. Using optimized conditions, we monitored the deprotonation of C7 ∙+ via Raman spectroscopy and the subsequent hydrogen abstraction from solvent molecules to regenerate C7 via electrochemistry. Finite element modeling was used to fit electrochemical and spectroscopic data, quantifying the deprotonation rates as k dep = 2000 and 700 L mol -1 s -1 and abstraction rates as k abs = 0.5 and 0.2 s - 1 in propylene carbonate and acetonitrile solvents, respectively. Our results show the value of spatiotemporal reso-lution in evaluating the chemical and electrochemical behavior of materials for redox flow batteries.

25 ENERGY STORAGE↗

Testing fast reactor fuels in a thermal reactor: Comparison of transmutation metallic fuel alloys behavior by scanning electron microscopy

To optimize nuclear waste repository performance, the destruction of minor actinide elements, particularly Np and Am, in a neutron fast spectrum reactor is possible by incorporating these elements into nuclear fuel. Evaluating the performance of minor actinide containing fuel is of paramount importance to enabling this technology. However, such a task is challenging without an available domestic fast spectrum test reactor. A comparison of fuel performance tested in an available domestic thermal reactor at the Idaho National Laboratory, the Advanced Test Reactor, and in a fast spectrum reactor in France (Phénix) is presented here in this study. This study evaluates the capability of using a cadmium shrouded test position to mimic the power profile along the fuel radius present in fast spectrum reactors so that thermally driven phenomenon (e.g., constituent redistribution) can be evaluated in a thermal reactor and determined to be prototypical of a fast reactor. Thus, optical microscopy and scanning electron microscopy has been performed on irradiated 35U-29Pu-4Am-2Np-30Zr fuel samples (where the number preceding the element is the weight percent concentration) from the two mentioned reactors that present similar irradiation temperatures and power conditions. The results indicate that fuel performance phenomena are reproducible in the two irradiation conditions. The redistribution of Zr occurred in the same manner for the two samples. Similar partitioning of U-Pu-Zr phases was observed, and the behavior of Am was similar in the analyzed specimens. Finally, the overall microstructure evolution seems not to be affected by minor actinides addition compared to expected behavior of conventional U-19Pu-10Zr ternary metal fuels for both specimens. Slight differences in fuel cladding chemical interaction were, however, observed. This difference is likely driven by difference in cladding composition rather than irradiation conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microscopic analysis of irradiated UN–Mo–W for space nuclear propulsion

Nuclear propulsion is an effective method of providing thrust in deep space, allowing for shorter mission duration for long-term surface missions to Mars. The fuel for nuclear propulsion systems must exhibit superior mechanical and thermal properties, to decrease the possibility of fuel failure and to increase reactor efficiency. Here, the objective of the Sirius project is to fabricate and irradiate cermet fuels at the Idaho National Laboratory Transient Reactor Facility to determine the properties of the fuel after irradiation at prototypical nuclear propulsion start-up conditions. The Sirius project featured 3 test capsules, Sirius-1 featured uranium nitride fuel dispersed in a matrix of tungsten and rhenium, while Sirius-2A and -2B featured uranium nitride-molybdenum-tungsten fuel (UN-Mo-W). The fuel samples from the Sirius-2A and -2B capsules were examined after irradiation using optical microscopy, scanning electron microscopy, and X-ray diffraction analyses. The mechanical properties of the fuel from Sirius-2A and -2B are discussed in a previous work. In this study, the results of the optical microscopy, scanning electron microscopy, and X-ray diffraction analyses are discussed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cathode Electrolyte Diagnostics Based on Scanning Probe Microscopy

Various processes lead to degradation of cathodes in lithium-ion batteries. Questions remain regarding mechanisms of many of these processes. Probe microscopy methods including scanning electrochemical microscopy (SECM) are capable of directly probing processes at the cathode/electrolyte interface. SECM uses a small electrode to perform rapid electrochemical analysis of transient species generated at an active cathode/electrolyte interface. This paper discusses the background of the SECM instrument and its application to lithium-ion battery research. We also describe the application of SECM methods to the study of cathode degradation processes observed in lithium-ion batteries. Specifically, we focus on characterizing the dissolution of manganese from LiMn2O4 (LMO) based on recent debate in the literature. We describe experiments to observe and characterize the electrochemical properties of manganese complexes emerging from degrading LMO electrode materials.

cathode/electrolyte interface↗

Fast Scanning Probe Microscopy via Machine Learning: Non-Rectangular Scans with Compressed Sensing and Gaussian Process Optimization

Fast scanning probe microscopy enabled via machine learning allows for a broad range of nanoscale, temporally resolved physics to be uncovered. However, such examples for functional imaging are few in number. Here, using piezoresponse force microscopy (PFM) as a model application, a factor of 5.8 reduction in data collection using a combination of sparse spiral scanning with compressive sensing and Gaussian process regression reconstruction is demonstrated. It is found that even extremely sparse spiral scans offer strong reconstructions with less than 6% error for Gaussian process regression reconstructions. Further, the error associated with each reconstructive technique per reconstruction iteration is analyzed, finding the error is similar past ≈15 iterations, while at initial iterations Gaussian process regression outperforms compressive sensing. Finally, this study highlights the capabilities of reconstruction techniques when applied to sparse data, particularly sparse spiral PFM scans, with broad applications in scanning probe and electron microscopies.

36 MATERIALS SCIENCE↗

Probing Activities of Individual Catalytic Nanoflakes by Tunneling Mode of Scanning Electrochemical Microscopy

The tunneling mode of scanning electrochemical microscopy (SECM) was developed recently and applied to studies of charge-transfer reactions at single metal nanoparticles (NPs). When an SECM tip is brought within the tunneling distance from a conductive NP, the particle begins to act as a part of the nanoelectrode. Herein, we demonstrate the possibility of using carbon nanoelectrodes with a very thin insulating sheath for electrochemical tunneling experiments at flat samples. In this way, electrocatalytic activity, conductivity, and charging properties of and faradaic processes in layered nanomaterials can be characterized by single-nanoflake voltammetry without making direct ohmic contact with them. A broad applicability of tunneling SECM experiments is demonstrated by probing nanomaterials with different size, geometry, and electrocatalytic properties, including metallic/pseudo-metallic (1T/1T') and semiconducting (2H) MoS 2 nanoflakes, N-doped porous carbon catalyst, and MXene nanosheets. Further, the Tafel plots for the hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) at individual nanoflakes are compared to analogous measurements for an ensemble of flakes attached to the surface of a macroscopic electrode. Moreover, we observed variations in catalytic activities of individual MXene flakes toward HER and OER caused by non-uniform doping.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Two Fast-Turnaround Dry Dilution Refrigerators for Scanning Probe Microscopy

Low-temperature scanning probe microscopes (SPMs) are critical for the study of quantum materials and quantum information science. Due to the rising costs of helium, cryogen-free cryostats have become increasingly desirable. However, they typically suffer from comparatively worse vibrations than cryogen-based systems, necessitating the understanding and mitigation of vibrations for SPM applications. Here, in this work, we demonstrate the construction of two cryogen-free dilution refrigerator SPMs with minimal modifications to the factory default and we systematically characterize their vibrational performance. We measure the absolute vibrations at the microscope stage with geophones and use both microwave impedance microscopy and a scanning single-electron transistor to independently measure tip-sample vibrations. Additionally, we implement customized filtering and thermal anchoring schemes and characterize the cooling power at the scanning stage and the tip electron temperature. This work serves as a reference to researchers interested in cryogen-free SPMs, as such characterization is not standardized in the literature or available from manufacturers.

36 MATERIALS SCIENCE↗

Improved Understanding of Zircaloy Hydrogen Pickup Mechanisms in BWRs. NSUF Report (Final Report)

Using an instrumented autoclave operating at 288°C and 1100 psi, electrical impedance spectroscopy (EIS) measurements were taken from three neutron irradiated fuel channel samples (Zircaloy-2 and Zircaloy-4). The three high priority fuel channel samples were tested at 288°C using a simulated PWR water with the AC frequency range extending down through 10 -4 Hz, with corresponding DC measurements to validate the resistance measurements. EIS measurements were also taken at room temperature using a simulated PWR water from four neutron irradiated fuel channel samples (Zircaloy-2 and Zircaloy-4). and four water rod samples (Zircaloy-2). EIS measurements were also performed on unirradiated Zircaloy-2 tubes that were previously oxidized in autoclaves at various temperatures for different time durations to obtain oxide layers of different thicknesses. These experiments proved to be more challenging than anticipated because of the small size of the samples, which required development of fixtures to allow valid testing of the materials, some of which are radioactive, under pressure and temperature. Equivalent circuits were used to model the data. Some samples resulted in Nyquist plots where the arcs were too close to each other resulting in the inability to separate the different oxide morphological thicknesses. Microstructural characterization in the form of optical microscopy, scanning electron microscopy and (scanning) transmission electron microscopy was performed to document the microstructural features of the oxidized Zr-2 and Zr-4 samples (oxide and metal/oxide interface) and to interpret the EIS results. At the start of this work, it was assumed that despite the laminar cracks and porosity visible in both optical and SEM, the oxide scale is dense near the metal, effectively preventing the water from contacting the metal directly. While it is generally accepted that the large laminar cracks pores allow the water to percolate into the oxide film, it is unknown just how deep it can go, and how interconnected is the porosity, which will dictate how much the porosity is connected electrically to the water within the oxide scale. The EIS results demonstrated that there is in fact a distribution of oxide thicknesses over the various samples, and within each material condition, that are communicating to the liquid. This is derived from the fact that Nyquist plots have an arc radius whose center point is often below the Z’ axis, implying that instead of a single oxide thickness, these oxides have a distribution of thicknesses. This distribution of thicknesses produces arcs that are not clearly separable in most of the samples.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electron Microscopy Transfer System to Protect Atmosphere‐Sensitive Materials for Scanning Electron Microscopy Characterization

Atmosphere- and/or moisture-sensitive materials can be challenging to characterize using electron microscopy techniques due to sample preparation workflows that generally require exposure to ambient conditions. Here, we describe a novel preparation method that uses aluminum foil in combination with a commercial cryo-EM transfer system to circumvent undesired exposure to the atmosphere. First, hygroscopic MgCl 2 was used as a model material, and prepared samples (both protected and unprotected) were placed in a controlled-humidity environment (> 80% relative humidity) for various exposure lengths (circa seconds to hours). Following this, the effectiveness of the sample preparation method was determined by comparing qualitative photos and quantitative X-ray diffraction patterns between the two sample subsets. The combined results of these experiments suggest that the outlined preparation method effectively protects MgCl 2 from atmospheric contamination compared to MgCl 2 samples that had no protective measures taken. Finally, the preparation method was utilized to protect a highly hygroscopic crystalline BaO thin film for characterization via scanning electron microscopy, thereby demonstrating a functional application of the outlined preparation technique and an additional use for the commercial cryo-EM transfer system beyond its intended application.

atmosphere-sensitive materials↗

Multidimensional visualization of the dynamic evolution of Li metal via in situ/operando methods

The growing demands for high-energy density electrical energy storage devices stimulate the coupling of conversion-type cathodes and lithium (Li) metal anodes. While promising, the use of these “Li-free” cathodes brings new challenges to the Li anode interface, as Li needs to be dissolved first during cell operation. In this study, we have achieved a direct visualization and comprehensive analysis of the dynamic evolution of the Li interface. The critical metrics of the interfacial resistance, Li growth, and solid electrolyte interface (SEI) distribution during the initial dissolution/deposition processes were systematically investigated by employing multidimensional analysis methods. They include three-electrode impedance tests, in situ atomic force microscopy, scanning electrochemical microscopy, and cryogenic scanning transmission electron microscopy. The high-resolution imaging and real-time observations show that a loose, diffuse, and unevenly distributed SEI is formed during the initial dissolution process. This leads to the dramatically fast growth of Li during the subsequent deposition, deviating from Fick’s law, which exacerbates the interfacial impedance. The compactness of the interfacial structure and enrichment of electrolyte species at the surface during the initial deposition play critical roles in the long-term stability of Li anodes, as revealed by operando confocal Raman spectroscopic mapping. In conclusion, our observations relate to ion transfer, morphological and structural evolution, and Li (de)solvation at Li interfaces, revealing the underlying pathways influenced by the initial dissolution process, which promotes a reconsideration of anode investigations and effective protection strategies.

25 ENERGY STORAGE↗

Towards automating structural discovery in scanning transmission electron microscopy *

Abstract Scanning transmission electron microscopy is now the primary tool for exploring functional materials on the atomic level. Often, features of interest are highly localized in specific regions in the material, such as ferroelectric domain walls, extended defects, or second phase inclusions. Selecting regions to image for structural and chemical discovery via atomically resolved imaging has traditionally proceeded via human operators making semi-informed judgements on sampling locations and parameters. Recent efforts at automation for structural and physical discovery have pointed towards the use of ‘active learning’ methods that utilize Bayesian optimization with surrogate models to quickly find relevant regions of interest. Yet despite the potential importance of this direction, there is a general lack of certainty in selecting relevant control algorithms and how to balance a priori knowledge of the material system with knowledge derived during experimentation. Here we address this gap by developing the automated experiment workflows with several combinations to both illustrate the effects of these choices and demonstrate the tradeoffs associated with each in terms of accuracy, robustness, and susceptibility to hyperparameters for structural discovery. We discuss possible methods to build descriptors using the raw image data and deep learning based semantic segmentation, as well as the implementation of variational autoencoder based representation. Furthermore, each workflow is applied to a range of feature sizes including NiO pillars within a La:SrMnO 3 matrix, ferroelectric domains in BiFeO 3 , and topological defects in graphene. The code developed in this manuscript is open sourced and will be released at github.com/nccreang/AE_Workflows .

47 OTHER INSTRUMENTATION↗

Uptake of polystyrene nanospheres by wheat and Arabidopsis roots in agar, hydroponics, and soil

Plant uptake of micro- and nanoplastics can lead to contamination of food with plastic particles and subsequent human consumption of plastics. There is evidence that plant roots can take up micro and nanoplastics; however, most of this evidence stems from experiments conducted with plants grown in hydroponics or agar systems where uptake of nanoparticles by roots is more favorable than when plants were grown in soil. Here, we discern the root uptake and accumulation of polystyrene nanospheres in plants grown in different growth media: agar, hydroponics, and soil. In addition, we tested the impacts of nanospheres on plant biomass and plant stress. Wheat and Arabidopsis thaliana were grown in agar, hydroponics, and soil media and exposed to polystyrene nanospheres. Three different nanospheres were used (40 nm and 200 nm carboxylate-modified and 200 nm amino-modified polystyrene) and uniformly mixed into the growth media. Plants were grown for 7 to 10 days and the roots were then examined for the presence of nanospheres by confocal laser scanning microscopy and scanning electron microscopy. Plant stress was evaluated by measuring reactive oxygen species (ROS). We observed the 40 nm nanospheres inside the plant roots, but the 200 nm nanospheres only adhered to the root cap cells showing no uptake into the roots. Furthermore, confocal images indicated that root uptake of nanospheres was favored in hydroponic solutions as compared to agar and soil media. Plant biomass was generally not affected by the nanospheres, except for hydroponically grown Arabidopsis thaliana, where biomass was significantly reduced. Small sized (40 nm) and positively charged (200 nm amino-modified) nanospheres showed higher ROS accumulation in plants than negatively charged 200 nm carboxylate-modified nanospheres. In conclusion, this study provides evidence that polystyrene nanospheres can be taken up into the interior of plant roots and cause plant stress, but these impacts are less pronounced in media where the plastic particles are less mobile, like in agar and soil media as compared to hydroponic systems.

54 ENVIRONMENTAL SCIENCES↗

Etching sharp tips from thin metallic wires for tuning-fork-based scanning probe microscopy

Sharp tips are critical for obtaining high resolution images in scanning probe microscopy (SPM), particularly in samples with large variations in topography. For tuning-fork-based SPM, such tips are commonly obtained by electrochemical etching of metallic wires (e.g., tungsten). Electrochemical etching of metallic wires is the preferred means of preparing tips for scanning tunneling microscopy (STM), and techniques for obtaining sharp tips have been investigated extensively. However, the requirements for STM and tuning-fork-based SPM are different. In particular, the wires used in STM are typically 250-500 μ m in diameter, while the wires used for tuning-fork-based SPM are usually an order of magnitude narrower in order to minimize loading of the tuning fork: 25-50 μ m and sometimes down to a few micrometers in diameter. Consequently, many of the recipes developed for etching thicker metallic wires for STM tips do not give optimal results for smaller diameter wires. The authors describe here a modification of the etching circuit of Ibe et al . that significantly improves the reproducibility and reliability of the etching process for thin wires, and discuss the parameters that affect the aspect ratio of produced tips.

42 ENGINEERING↗

Electrochemical Imaging of Interfaces in Energy Storage via Scanning Probe Methods: Techniques, Applications, and Prospects

Developing a deeper understanding of dynamic chemical, electronic, and morphological changes at interfaces is key to solving practical issues in electrochemical energy storage systems (EESSs). To unravel this complexity, an assortment of tools with distinct capabilities and spatiotemporal resolutions have been used to creatively visualize interfacial processes as they occur. This review highlights how electrochemical scanning probe techniques (ESPTs) such as electrochemical atomic force microscopy, scanning electrochemical microscopy, scanning ion conductance microscopy, and scanning electrochemical cell microscopy are uniquely positioned to address these challenges in EESSs. We describe the operating principles of ESPTs, focusing on the inspection of interfacial structure and chemical processes involved in Li-ion batteries and beyond. We discuss current examples, performance limitations, and complementary ESPTs. Finally, we discuss prospects for imaging improvements and deep learning for automation. We foresee that ESPTs will play an enabling role in advancing EESSs as we transition to renewable energies.

25 ENERGY STORAGE↗

Viewing Optical Processes at the Nanoscale: Combining Scanning Tunneling Microscopy and Optical Spectroscopy

The combination of optical spectroscopy and scanning tunneling microscopy techniques has the potential to yield the unambiguous single-molecule level insight required to fully understand the complex structure–property relationship of emerging material systems. In this Perspective, we highlight the recent progress of single-molecule absorption detected by scanning tunneling microscopy (SMA-STM) to investigate light–matter interactions of supported (nano)particles, quantum dots, and molecular and thin films at the nanoscale. We further show how the SMA-STM technique has been recently extended to expand the classes of materials that can be investigated as well as recent design modifications that enable both time-resolved imaging and tomography. Finally, we hypothesize how these modifications can be further leveraged to advance our current knowledge of light–matter interactions and how the resulting nanoscale insight can be implemented for future material applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning Electrochemical Microscopy: An Evolving Toolbox for Revealing the Chemistry within Electrochemical Processes

The parallel development of ultramicroelectrodes (UMEs) and groundbreaking scanning probe microscopy techniques in the late 1980s led to the development of the scanning electrochemical microscope. Scanning electrochemical microscopy (SECM) was born from the idea of using a tiny electrode to measure the local electrochemical behavior at operating electrodes. From its foundations, the technique displayed an inherent versatility in measuring sample properties beyond topography. It allowed experimenters to measure and map chemical reactions occurring at diverse interfaces, from inspecting the reversibility of redox mediators at metal electrodes, to detecting the hallmarks of cellular respiration on living plant leaves. Related but distinct electrochemical scanning probe techniques, such as electrochemical atomic force microscopy (EC-AFM), scanning ion conductance microscopy (SICM), and scanning electrochemical cell microscopy (SECCM) have developed in parallel. These techniques have demonstrated exquisite spatial resolution down to the nanoscale regime. However, it is the proposition of this review that SECM remains unmatched at revealing the chemical aspects of electrochemistry. Furthermore, it is our intention to review and demonstrate that the versatile architecture of SECM continues to evolve and address fundamental and emerging challenges in the fields of energy storage and conversion, chemical biology, materials science, and environmental chemistry, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗