Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning tunneling microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mechanisms Underlying a Quantum Superposition Microscope Based on THz-Driven Coherent Oscillations in a Two-Level Molecular Sensor

Here we report pump-probe measurements of a hydrogen molecule (H 2 ) in the tunnel junction of a scanning tunneling microscope (STM) coupled to ultrashort terahertz (THz) pulses. The coherent oscillation of the THz induced DC tunneling current at a frequency of ~0.5 THz fingerprints the absorption by H 2 as a two-level system (TLS). Two components of the oscillatory signal are observed and point to both photon and field aspects of the THz pulses. A few loosely bound states with similar energies for the upper state of the TLS are evidenced by the coherent revival of oscillatory signal. Furthermore, the comparison of spectroscopic features of H 2 with different tips provides an understanding of the TLS for H 2 .

36 MATERIALS SCIENCE↗

Imaging Valley Excitons in a 2D Semiconductor with Scanning Tunneling Microscope-Induced Luminescence

Valley excitons dominate the optoelectronic response of transition-metal dichalcogenides and are drastically affected by structural and environmental inhomogeneities localized in these materials. Critical to understanding and controlling these nanoscale excitonic changes is the ability to correlate the imaging of excitonic states with crystalline structures on the atomic scale. Here, in this study, we apply scanning tunneling microscope-induced luminescence microscopy to image valley excitons in a semiconducting transition-metal dichalcogenide monolayer decoupled by a 10 nanometer-thick hexagonal-boron-nitride flake incorporated in a lateral homojunction on an Au electrode surface. This design enables the observation of chiral excitonic emission arising from neutral and charged valley excitons of the monolayer semiconductor at ambipolar voltages with a quantum efficiency up to similar to ~10 -5 photon/electron. The measured light helicity demonstrates considerable circular polarization dependent on the sample voltage, reaching as much as 40%. The real-space luminescence imaging maps$-$at subnanometer resolution$-$of the valley excitons reveal striking spatial variations associated with localized inhomogeneities, including surface impurities and possibly nanoscale dielectric and/or potential disorders in the monolayer. Our study introduces a promising format for 2D materials to explore and tailor their optoelectronic processes at the atomic scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data reduction of digitized images processed from calibrated photographic and spectroscopic films obtained from terrestial, rocket and space shuttle telescopic instruments

The Microvax 2 computer, the basic software in VMS, and the Mitsubishi High Speed Disk were received and installed. The digital scanning tunneling microscope is fully installed and operational. A new technique was developed for pseudocolor analysis of the line plot images of a scanning tunneling microscope. Computer studies and mathematical modeling of the empirical data associated with many of the film calibration studies were presented. A gas can follow-up experiment which will be launched in September, on the Space Shuttle STS-50, was prepared and loaded. Papers were presented on the structure of the human hair strand using scanning electron microscopy and x ray analysis and updated research on the annual rings produced by the surf clam of the ocean estuaries of Maryland. Scanning electron microscopic work was conducted by the research team for the study of the Mossbauer and Magnetic Susceptibility Studies on NmNi(4.25)Fe(.85) and its Hydride.

Hammond, Ernest C., Jr.↗

0.4 Microns Spatial Resolution with 1 GHz (lambda = 30 cm) Evanescent Microwave Probe

In this article we describe evanescent field imaging of material nonuniformities with a record resolution of 0.4 microns at 1 GHz (lambda(sub g)/750000), using a resonant stripline scanning microwave probe. A chemically etched tip is used as a point-like evanescent field emitter and a probe-sample distance modulation is employed to improve the signal-to-noise ratio. Images obtained by evanescent microwave probe, by optical microscope, and by scanning tunneling microscope are presented for comparison. Probe was calibrated to perform quantitative conductivity measurements. The principal factors affecting the ultimate resolution of evanescent microwave probe are also discussed.

Tabib-Azar, M.↗

Alkali layered compounds interfaces for energy conversion and energy storage

During year one a new ultra-high vacuum, an Ar(+) ion sputterer, a low energy electron diffraction (LEED) system, an Auger electron spectrometer (AES), a work function measurement device with a Kelvin probe, and related accessories were used. The study found a focus in the adsorption of chalcogenides on Si and III-V compound semiconductors. In the second year, a scanning tunneling microscope was obtained along with a quadrapole mass spectrometer, power supplies, a computer, a chart recorder, etc. We started the systematic study on the adsorption of chalcogenides on the compound semiconductor surfaces. The third year saw the mounting of the scanning tunneling microscope (STM) on the existing UHV system. The investigation continued with the adsorption of Cs (alkali) on S-covered Si(100)2x1 surfaces. Then the adsorption of S on Cs-covered Si(100) surfaces was studied.

Papageorgopoulos, Chris A.↗

Avoided Level Crossing and Entangled States of Interacting Hydrogen Molecules Detected by the Quantum Superposition Microscope

Pump–probe measurements by ultrashort THz pulses can be used to excite and follow the coherence dynamics in the time domain of single hydrogen molecules (H 2 ) in the junction of a scanning tunneling microscope (STM). By tailoring the resonance frequency through the sample bias, we identified two spectral signatures of the interactions among multiple H 2 molecules. First, the avoided level crossing featured by energy gaps ranging from 20 to 80 GHz was observed because of the level repulsion between two H 2 molecules. Second, the tip can sense the signal of H 2 outside the junction through the projective measurement on the H 2 inside the junction, owing to the entangled states created through the interactions. A dipolar-type interaction was integrated into the tunneling two-level system model of H 2 , enabling accurate reproduction of the observed behaviors. Furthermore, our results obtained by the quantum superposition microscope reveal the intricate quantum mechanical interplay among H 2 molecules and additionally provide a 2D platform to investigate unresolved questions of amorphous materials.

36 MATERIALS SCIENCE↗

Tunneling magnetic force microscopy

We have developed a powerful new tool for studying the magnetic patterns on magnetic recording media. This was accomplished by modifying a conventional scanning tunneling microscope. The fine-wire probe that is used to image surface topography was replaced with a flexible magnetic probe. Images obtained with these probes reveal both the surface topography and the magnetic structure. We have made a thorough theoretical analysis of the interaction between the probe and the magnetic fields emanating from a typical recorded surface. Quantitative data about the constituent magnetic fields can then be obtained. We have employed these techniques in studies of two of the most important issues of magnetic record: data overwrite and maximizing data-density. These studies have shown: (1) overwritten data can be retrieved under certain conditions; and (2) improvements in data-density will require new magnetic materials. In the course of these studies we have developed new techniques to analyze magnetic fields of recorded media. These studies are both theoretical and experimental and combined with the use of our magnetic force scanning tunneling microscope should lead to further breakthroughs in the field of magnetic recording.

Burke, Edward R.↗

In situ plasmonic tip preparation and validation techniques for scanning tunneling microscopy

Among the many parts constituting a scanning tunneling microscope, the metallic tip is the component that directly interacts with the specimen and plays a critical role in visualizing the physical quantity of interest. While tip materials such as W and Pt–Ir are commonly used for topographic imaging and their preparation is well-documented, the preparation of plasmonic materials such as Ag for tip-enhanced Raman spectroscopy is relatively less standardized. Furthermore, we present several in situ Ag tip preparation and validation techniques for the microscopist to use depending on their intended application, including atomic resolution imaging, scanning tunneling spectroscopy (STM), and tip-enhanced Raman spectro-microscopy in ultrahigh vacuum. Besides optical applications, these methods are not limited to Ag but also applicable to other STM tip materials.

47 OTHER INSTRUMENTATION↗

Simplified feedback control system for scanning tunneling microscopy

A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few Å. Often, the tunneling current between the tip and the sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here, we discuss another approach using a computer and data acquisition through the universal serial bus port. We find that it allows successful ultralow noise studies of surfaces at cryogenic temperatures. We show results on different compounds including a type II Weyl semimetal (WTe2), a quasi-two-dimensional dichalcogenide superconductor (2H–NbSe2), a magnetic Weyl semimetal (Co3Sn2S2), and an iron pnictide superconductor (FeSe).

Martín-Vega, Francisco (ORCID:0000000333177833)↗

Atomically precise digital e-beam lithography

Hydrogen Depassivation Lithography (HDL) is a version of electron beam lithography that uses scanning tunneling microscope (STM) instrumentation to expose a self–developing resist that is a monolayer of H chemisorbed to a Si (100) 2x1 H-passivated surface. Developed in the 1990s it has been largely a laboratory tool used in research for nanofabrication. Here, the technique is capable of atomic resolution, the ability to remove single H atoms from the Si surface and has much higher precision than the best conventional e-beam lithography can possibly achieve exposing polymeric resists. However, its most promising attribute is that it can be used as a digital fabrication tool and is the first of a class of nanofabrication techniques that can be considered digital atomic scale fabrication technologies. Digital Atomic Scale Fabrication can be shown to have similar advantages over analog fabrication techniques that digital information technology has over analog information technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electrical Manipulation of Quantum Coherence in a Two-Level Molecular System

We report the manipulation of ultrafast quantum coherence of a two-level single hydrogen molecular system by employing static electric field from the sample bias in a femtosecond terahertz scanning tunneling microscope. A H 2 molecule adsorbed on the polar Cu 2⁢ N surface develops an electric dipole and exhibits a giant Stark effect. An avoided crossing of the quantum state energy levels is derived from the resonant frequency of the single H 2 two levels in a double-well potential. The dephasing time of the initial wave packet can also be changed by applying the electric field. The electrical manipulation for different tunneling gaps in three dimensions allows quantification of the surface electrostatic fields at the atomic scale. Further, our work demonstrated the potential application of molecules as controllable two-level molecular systems.

36 MATERIALS SCIENCE↗

Plutonium Dedicated Surface Probe Microscopy Capability

An atomic force microscope (AFM) equipped with gas dosing capabilities and a scanning tunneling microscope (STM) housed within a vacuum chamber with Pu sputtering capabilities and the potential for rapid heating via electron bombardment have been devised for investigations of Pu surface aging (such as oxidation, corrosion, and self-irradiation damage), reactivity, and rapid heating. These instruments are capable of probing Pu surface areas ranging from a fractions of nm2 (STM) to hundreds of μm2 (AFM) to obtain three dimensional imaging of surface microstructure and morphology, as well as mapping of the local electronic structure (i.e., the occupied and unoccupied electronic states), surface chemical, and mechanical properties. A detailed description of our surface probe microscopy (SPM) capability, specifically designed for handling of Pu coupons is given in the references. In FY20, four tasks have been undertaken: Resumed maintenance of Pu AFM and modification of STM capabilities including calibration, annual measurement of Pu surface, and implementation of additional instrumentation for rapid heating effort; Analyzed AFM FY19 gas dosing experiment data of 7 at% gallium-stabilized δ-phase Pu (δ-Pu) coupon; Determined the direction of future gas dosing experiments to investigate reversibility of surface features; and, Published a paper titled "Effects of ion sputtering on plutonium surfaces" in the Journal of Nuclear Materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Magnetic states of atomic vacancies in graphite probed by scanning tunneling microscopy

Intrinsic defects in graphitic materials, like vacancies and edges, have been expected to possess magnetic states from the many-body interaction of localized electrons. However, charge screening from graphite bulk carriers significantly reduces the localization effect and hinders the observation of those magnetic states. Here, we use an ultra-low-temperature scanning tunneling microscope with a high magnetic field to observe the magnetic states of atomic vacancies in graphite generated by ion sputtering. Scanning tunneling spectroscopy reveals localized states at the vacancies, which exhibit splitting at a certain magnetic field whose separation increases with the field strength. The transition is well described by the “Anderson model,” which describes the emergence of localized magnetic states inside the metallic reservoir through electron–electron interaction. The interaction strength is estimated to be between 1 meV and 3 meV, which is supported by the density functional theory calculation. The observation provides an important foundation for application of intrinsic defects to carbon-based spintronic devices.

36 MATERIALS SCIENCE↗

Strong-coupling quantum dot microscope

Here, we report the development and fabrication of a novel cryogenic instrument, a scanning quantum dot microscope (SQDM), capable of positioning a quantum dot to within tunneling range of a sample surface. The microscope is strong-coupling in the sense that electron wavefunctions in the quantum dot can directly overlap with electron wavefunctions in the sample, in contrast to probes based on electric-field coupling. The SQDM consists of a sharp glass probe with two asymmetric electrodes leading to an aluminum quantum dot at the apex. One electrode is capacitively coupled to the quantum dot, while the other lead is connected to the dot via a tunneling junction. A charge sensing circuit constructed from a high-electron-mobility transistor is attached to the capacitance lead to measure the charge state of the dot. The last key feature of the design is a tilted-apex geometry. This design feature, in conjunction with the capacitive sensing scheme, results in a robust quantum-dot probe capable of operating within angstrom distances of the sample surface while protecting the single tunnel junction responsible for electron transport onto the quantum dot. We demonstrate that our instrument can detect single-electron tunneling events and can also be operated as a standard scanning tunneling microscope capable of nanometer-scale resolution of the surface topography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface characterization and testing II; Proceedings of the Meeting, San Diego, CA, Aug. 10, 11, 1989

Various papers on surface characterization and testing are presented. Individual topics addressed include: simple Hartmann test data interpretation, optimum configuration of the Offner null corrector, system for phase-shifting interferometry in the presence of vibration, fringe variation and visibility in speckle-shearing interferometry, functional integral representation of rough surfaces, calibration of surface heights in an interferometric optical profiler, image formation in common path differential profilometers, SEM of optical surfaces, measuring surface profiles with scanning tunneling microscopes, surface profile measurements of curved parts, high-resolution optical profiler, scanning heterodyne interferometer with immunity from microphonics, real-time crystal axis measurements of semiconductor materials, radial metrology with a panoramic annular lens, surface analysis for the characterization of defects in thin-film processes, Spacelab Optical Viewport glass assembly optical test program for the Starlab mission, scanning differential intensity and phase system for optical metrology.

Greivenkamp, John E.↗

High signal-to-noise ratio differential conductance spectroscopy

The scanning tunneling microscope (STM) has enabled manipulation and interrogation of surfaces with atomic-scale resolution. Electronic information about a surface is obtained by combining the imaging capability of the STM with scanning tunneling spectroscopy, i.e., measurement of current-voltage (I/V) characteristics of the surface. We propose a change in the STM feedback loop that enables capturing a higher quality dI/dV image. A high frequency dither voltage is added to the bias voltage of the sample, and the fundamental frequency component of the resulting current is demodulated. The in-phase component of this signal is then plotted along with the X and Y position data, constructing the dI/dV image. Here, we show that by incorporating notch filters in the STM feedback loop, we may utilize a high-amplitude dither voltage to significantly improve the quality of the obtained dI/dV image.

42 ENGINEERING↗

Electronic Transport through Self Assembled Thiol Molecules: Effect of Monolayer Order, Dynamics and Temperature

We present the charge transport and tunneling conductance of self assembled organic thiol molecules and discuss the influence of order and dynamics in the monolayer on the transport behavior and the effect of temperature. Conjugated thiol molecular wires and organometals such as terpyridine metal complexes provide a new platform for molecular electronic devices and we study their self assembly on Au(111) substrates by the scanning tunneling microscope. Determining the organization of the molecule and the ability to control the nature of its interface with the substrate is important for reliable performance of the molecular electronic devices. By concurrent scanning tunneling microscopy and spectroscopy studies on SAMs formed from oligo (phenelyne ethynelyne) monolayers with and without molecular order, we show that packing and order determine the response of a self assembled monolayer (SAM) to competing interactions. Molecular resolution STM imaging in vacuum shows that the OPES adopt an imcommensurate SAM structure on Au(111) with a rectangular unit cell. Tunneling spectroscopic measurements were performed on the SAM as a function of junction resistance. STS results show that the I-Vs are non linear and asymmetric due to the inherent asymmetry in the molecular structure, with larger currents at negative sample biases. The asymmetry increases with increasing junction resistance due to the asymmetry in the coupling to the leads. This is brought out clearly in the differential conductance, which also shows a gap at the Fermi level. We also studied the effect of order and dynamics in the monolayer on the charge transport and found that competing forces between the electric field, intermolecular interactions, tip-molecule physisorption and substrate-molecule chemisorption impact the transport measurements and its reliability and that the presence of molecular order is very important for reproducible transport measurements. Thus while developing new electronic platforms based on molecules, it is important to have a good control of the molecule-substrate interface, for the devices to perform reliably. While such a control would minimize fluctuations and dynamics in the ensemble, the real challenge is to develop device architectures that are tolerant to fluctuations, since they cannot be totally eliminated in these low dimensional soft systems. Results of temperature dependent STS measurements will also be discussed.

Dholakia, Geetha↗