Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Brillouin fiber laser sensor

Brillouin fiber sensors can provide distributed strain and temperature measurements over long distances in standard off-the-shelf fiber by measuring the Brillouin frequency shift as a function of position along a fiber. The primary drawback of these systems is their limited sensitivity, which results from the challenge in identifying the Brillouin frequency shift to within a small fraction of the Brillouin linewidth. In this work, we introduce a technique that overcomes this fundamental limitation by establishing a series of lasing modes that experience Brillouin amplification at discrete spatial locations in the test fiber. The linewidth narrowing and high intensity associated with the lasing transition enable precise measurements of this lasing frequency. As an initial demonstration, we present a sensor that simultaneously excites 40 lasing modes in a 400 m fiber, providing a measurement of the strain at 40 discrete locations with a spatial resolution of 4 m. Each sensor exhibits a minimum detectable strain as low as 4 nε/Hz 1/2 with a dynamic range of >5 mε and a bandwidth of ~10 kHz. As the first demonstration that Brillouin lasing can be used for distributed fiber sensing, this work establishes an approach that could enable ultra-high strain sensitivity using off-the-shelf fiber.

47 OTHER INSTRUMENTATION↗

Machine-Learning Enabled Evaluation of Probability of Piping Degradation In Secondary Systems of Nuclear Power Plants

The transition to condition-based, risk-informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. Furthermore, of the operations and maintenance costs in U.S. plants, approximately 80% are labor costs. To address the issue of rising operating costs and economic viability, technologies used to perform online monitoring of piping and other secondary system structural components in commercial nuclear power plants (NPPs) are under evaluation. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real time measurements, rather than at a pre-determined inspection interval thus reducing the maintenance cost. This paper describes distributed high-temperature stable fiber sensors fabricated in optical fibers through a roll-to-roll laser direct writing process using femtosecond lasers. Using phase-sensitive optical time domain reflectometry, distributed acoustic and vibration sensors can be developed and deployed to critical components and systems in NPPs to perform active measurements with spatial resolution down to 0.5-meter throughout the piping systems. Complex acoustic and vibration signatures harnessed by distributed sensors are registered and analyzed by artificial intelligence algorithms for degradation detection and flaw identification. Piping elbows with machined-in flaws were instrumented with fiber sensors. High-spatial-resolution data were used to develop and validate machine learning algorithms, including both linear and nonlinear regression, and classification. Additionally, classification and sensor analysis were also performed for data analysis. The paper concludes with recommendations and future work on applications of machine learning enabled high-resolution fiber sensors for piping degradation monitoring in current or future NPPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed fiber-optic sensor network for sensing the corrosion onset and quantification

Materials, methods of making, and methods of sensing liquid droplets with high spatial resolution as a signature of the on-set of corrosion using a hierarchical sensor network A hierarchical sensor network for sensing liquid droplets with high spatial resolution as a signature of the on-set of corrosion, including an interrogation system; and an intermediate sensor array layer in communication with the interrogation system. The network includes an interrogation system and an intermediate sensor array layer in communication with the interrogation system.

Ohodnicki, Paul R.↗

Field-resolved space–time characterization of few-cycle structured light pulses

Accompanied by the rapid development of ultrafast laser platforms in recent decades, the spatiotemporal manipulation of ultrashort laser pulses has attracted much attention due to the potential for cutting-edge applications of structured light, including optical tweezers, optical communications, super-resolution imaging, time-resolved spectroscopy in molecules and quantum materials, and strong-field physics. Today, techniques capable of characterizing the full spatial, temporal, and polarization state properties of structured light are strongly desired. Here, we demonstrate a technique, termed 3D TIPTOE, for characterizing structured mid-infrared waveforms, which uses only a two-dimensional silicon-based image sensor as both the detector and the nonlinear medium. By combining the advantages of the sub-cycle time resolution afforded by nonlinear excitation and the spatial resolution inherent to the two-dimensional sensor, the 3D TIPTOE technique allows full characterization of structured electric fields, significantly reducing the complexity of detection compared to other techniques. The validity of the technique is established by measuring both few-cycle Bessel–Gaussian pulses and radially polarized femtosecond vector beams.

Liu, Yangyang (ORCID:0000000335205332)↗

High spatial resolution temperature profile measurements of solid-oxide fuel cells

Temperature gradients resulting from local electrochemical reactions, current distribution and geometry of gas flow channels in solid oxide fuel cells (SOFCs) create thermal stresses, localized thermophysical property gradients and uneven property evolution, contributing to SOFC degradation. This paper presents a new method to perform temperature measurements (up to 800°C) at high spatial resolutions to monitor the operation of SOFCs. Using femtosecond laser irradiation, distributed fiber sensors were hardened for high temperature environment applications. Distributed fiber sensors were embedded in interconnected plates using an additive manufacturing method to perform temperature measurements with 4-mm spatial resolution during the operation of a planar fuel cell. The measurement revealed the impact of various H 2 fuel concentrations and current loads have on temperature profiles of the SOFC tested. Temperature variation on the anode side was found to be less than 5°C, and 3°C on the cathode side. The measurements were compared to results from a multiphysics fuel cell performance model simulating similar conditions. These simulations predicted similar temperature gradients, indicating the experimental data obtained is reasonable. The model also predicts that the effect of the embedded sensor has on the local temperature will be minimal and that the gradient of temperature in the gas channels will be captured despite the separation between the sensor and the gas flow. Finally, the high spatial resolution data harnessed by these distributed fiber sensors provides experimental support for model-based design and optimization to improve the operational efficiency and longevity of solid oxide fuel cells and fuel cell assemblies.

25 ENERGY STORAGE↗

Insights from application of a hierarchical spatio-temporal model to an intensive urban black carbon monitoring dataset

Existing regulatory pollutant monitoring networks rely on a small number of centrally located measurement sites that are purposefully sited away from major emission sources. While informative of general air quality trends regionally, these networks often do not fully capture the local variability of air pollution exposure within a community. Recent technological advancements have reduced the cost of sensors, allowing air quality monitoring campaigns with high spatial resolution. The 100×100 black carbon (BC) monitoring network deployed 100 low-cost BC sensors across the 15 km 2 West Oakland, CA community for 100 days in the summer of 2017, producing a nearly continuous site-specific time series of BC concentrations which we aggregated to one-hour averages. Leveraging this dataset, we employed a hierarchical spatio-temporal model to accurately predict local spatio-temporal concentration patterns throughout West Oakland, at locations without monitors (average cross-validated hourly temporal R 2 =0.60). Using our model, we identified spatially varying temporal pollution patterns associated with small-scale geographic features and proximity to local sources. In a sub-sampling analysis, here we demonstrated that fine scale predictions of nearly comparable accuracy can be obtained with our modeling approach by using ~30% of the 100×100 BC network supplemented by a shorter-term high-density campaign.

54 ENVIRONMENTAL SCIENCES↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Field demonstration of a tracer method to track simulated exhaled air trajectories and mixing in three connected rooms with upper-room GUV

We conducted tracer gas experiments in three connected nursery rooms to track simulated exhaled air trajectories and mixing. We emulated exhaled air with a pulse release of ethanol and measured its concentration with 2s time resolution with spatially distributed metal oxide sensors in both the upper and occupied levels of the room. We found that the overhead cooling supply air enhanced vertical air mixing within the rooms. When a room had higher supply airflow than the others, the tracer gas mixed quickly in that room because the supply air dominated the room mixing, thereby isolating it from air mixing with the other rooms. When the forced air system was not operating, the tracer gas resided longer in the upper room before descending. The tracer method also depicts air trajectories from different release locations by detecting the release point and affecting nearby sensors. These experiments support the potential of this method to be used in the field for understanding air trajectories in rooms with upper-room GUV.

Um, Chai Yoon↗

Forward silicon vertex/tracking detector design and R$\&$D for the future Electron-Ion Collider

The proposed high-luminosity high-energy Electron-Ion Collider (EIC) will provide a clean environment to precisely study several fundamental questions in the fields of high-energy and nuclear physics . A low material budget and high granularity silicon vertex/tracking detector is critical to carry out a series of hadron and jet measurements at the future EIC especially for the heavy flavor product reconstruction or tagging. The conceptual design of a proposed forward silicon tracking detector with the pseudorapidity coverage from 1.2 to 3.5 has been developed in integration with different magnet options and the other EIC detector sub-systems. The tracking performance of this detector enables precise heavy flavor hadron and jet measurements in the hadron beam going direction. The detector R&D for the proposed silicon technology candidates: Low Gain Avalanche Diode (LGAD) and radiation hard depleted Monolithic Active Pixel Sensor (MALTA), which can provide good spatial and timing resolutions, is underway. Bench test results of the LGAD and MALTA prototype sensors will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100% fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 μm width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. Overall, the experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

47 OTHER INSTRUMENTATION↗

Characterization of the upgraded single-line-of-sight time-resolved x-ray imager using short-pulse visible and UV lasers

The single-line-of-sight time-resolved x-ray imager (SLOS-TRXI), a fast-gated x-ray imager used for capturing x-ray self-emission in inertial confinement fusion experiments on OMEGA, has been upgraded and characterized. SLOS-TRXI combines an electron-dilation imager and a hybrid complementary metal–oxide–semiconductor (hCMOS) sensor to capture multiple gated frames on a single line of sight with a temporal resolution of ~40 ps and a spatial resolution of 10 µm. The original hCMOS sensor with four frames was replaced with a newer-generation hCMOS sensor having eight frames. Gate characterizations of both the sensor and the entire SLOS-TRXI diagnostic were performed using ~10-ps FWHM visible (2ω) and UV (4ω) short-pulse lasers, respectively. A stepped echelon was used to generate a train of five UV laser pulses having an interpulse separation of 30 ± 3 ps. Characterization results of the hCMOS gating (2.28 ± 0.02-ns FWHM on average) and a temporal resolution of the upgraded SLOS-TRXI (34 ± 4-ps FWHM on average) are presented. A temporal magnification for the electron-dilation imager between 40 and 60 was inferred from the characterization results. Furthermore, the spatial resolution of the upgraded SLOS-TRXI remains the same in light of this work.

47 OTHER INSTRUMENTATION↗

Survey of AC-LGADs for future 4D trackers with a proton beam

We will present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility, and a study of the performance of AC-LGAD sensors as a function of their thickness. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. Long strip sensors with sparse readout offer better cost and performance for applications where channel count or electrical power density is a constraint. Thanks to the excellent signal to noise ratio in AC-LGADs, sparse readout can be exploited without significant degradation of spatial or time resolution, which is demonstrated in our studies. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. We will present our studies of the sensor geometry optimizatio n to maintain the desirable sensor performance characteristics with increasingly larger electrodes.

43 PARTICLE ACCELERATORS↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We will present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility, and a study of the performance of AC-LGAD sensors as a function of their thickness. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. Long strip sensors with sparse readout offer better cost and performance for applications where channel count or electrical power density is a constraint. Thanks to the excellent signal to noise ratio in AC-LGADs, sparse readout can be exploited without significant degradation of spatial or time resolution, which is demonstrated in our studies. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. We will present our studies of the sensor geometry optimization to maintain the desirable sensor performance characteristics with increasingly larger electrodes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100$\%$ fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 $\mu$m width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. The experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of High-Temperature Bonding Techniques to Enable High-Temperature Static or Dynamic Strain Measurements

Current light-water nuclear reactors rely on a variety of different sensors and sensor applications to meet their structural health monitoring needs throughout the entirety of the reactor primary, secondary, and containment systems. Optical fiber–based sensor technologies could provide solutions to reduce the sensor system footprint while enhancing the measurement fidelity and spatial resolution by leveraging distributed monitoring techniques. Moreover, advanced reactors may require optical fiber–based sensors for structural health monitoring because their operating temperatures will exceed the limits of conventional transducers used to acquire dynamic strain or acoustic data in nuclear power plants. Therefore, this report describes experiments targeting the development of high-temperature bonding techniques that would allow for potentially long lengths of fibers to be bonded to metallic reactor components in advanced reactor systems. The high temperatures experienced within target application, next-generation nuclear reactors, necessitate a high-temperature resistant bond to limit the amount of tension on the fiber at the target application temperature. The primary bonding method investigated in this work is brazing; hot-rolling has also been investigated to a lesser extent. Both techniques are well-suited to bonding optical fibers to large reactor components such as primary coolant piping, pressure vessels, or heat exchangers. Optical frequency domain reflectometry was used to monitor the strain in metal-coated optical fibers before, during, and after the high-temperature bonding process. On select optical fibers that were successfully bonded, additional thermal cycling was performed to assess the extent to which the fiber remained bonded based on the expected thermal expansion of the test specimen material. The results of the various experiments yielded the following general conclusions: (1) brazing is a viable technique for bonding and allows significant compressive strain to be applied to the fiber at room temperature; (2) hot-rolling is a viable technique as well, which has been more optimized than the brazing technique for bonding, but less residual compressive strain has been observed with this technique; and (3) both techniques will need further development and optimization to demonstrate bonding of a long length of fiber that can provably operate at relevant temperatures for an advanced nuclear reactor application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Massively distributed fiber strain sensing using Brillouin lasing

Brillouin based distributed fiber sensors present a unique set of characteristics amongst fiber sensing architectures. They are able to measure absolute strain and temperature over long distances, with high spatial resolution, and very large dynamic range in off-the-shelf fiber. However, Brillouin sensors traditionally provide only modest sensitivity due to the weak dependence of the Brillouin frequency on strain and the high signal to noise ratio required to identify the resonance’s peak frequency to within a small fraction of its linewidth. Recently, we introduced a technique which substantially improves the precision of Brillouin fiber sensors by exciting a series of lasing modes in a fiber loop cavity that experience Brillouin amplification at discrete locations in the fiber. The narrow-linewidth and high intensity of the lasing modes enabled ultra-low noise Brillouin sensors with large dynamic range. However, our initial demonstration was only modestly distributed: measuring strain at 40, non-contiguous positions along a 400 m fiber. In this work, we greatly extend this methodology to enable fully distributed sensing at 1000 contiguous locations along 3.5 km of fiber—an order of magnitude increase in sensor count and range. This highly-multiplexed Brillouin fiber laser sensor provides a strain noise as low as 34 nɛ/√Hz and we analyze the limiting factors in this approach.

47 OTHER INSTRUMENTATION↗