Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sheep”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Factors modifying the response of large animals to low-intensity radiation exposure

In assessing the biological response to space radiation, two of the most important modifying factors are dose protraction and dose distribution to the body. Studies are reported in which sheep and swine were used to compare the hematology and lethality response resulting from radiation exposure encountered in a variety of forms, including acute (high dose-rate), chronic (low dose-rate), combinations of acute and chronic, and whether received as a continuous or as fractionated exposure. While sheep and swine are basically similar in response to acute radiation, their sensitivity to chronic irradiation is markedly different. Sheep remain relatively sensitive as the radiation exposure is protracted while swine are more resistant and capable of surviving extremely large doses of chronic irradiation. This response to chronic irradiation correlated well with changes in radiosensitivity and recovery following an acute, sublethal exposure.

Page, N. P.↗

Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience

BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

Validation Studies↗

Pulmonary hypoxic vasoconstriction: how strong? How fast?

We have developed a minimally invasive technique for studying regional blood flow in conscious sheep, bypassing the complications of open-chest surgery, flow probes and tracer infusion. We quantitate regional perfusion continuously on the basis of regional clearance of methane (methane is produced in the sheep rumen, enters the circulation and is eliminated nearly completely (greater than 95%) in the lung). Tracheal intubation with a dual-lumen catheter isolates the gas exchange of the right apical lobe (RAL; less than 15% of the lung) from that of the remainder of the lung, which serves as a control (CL). We measure RAL and CL methane elimination by entraining expirates in constant flows, sampled continuously for methane. Results obtained with this technique and from regional oxygen uptake are in excellent agreement. We have found that hypoxic vasoconstriction is far more potent and stable during eucapnic hypoxia than during hypocapnic hypoxia. The time course of the vasoconstriction suggests that many of the data in the literature may have been obtained prior to steady state.

NASA Discipline Regulatory Physiology↗

Effect of simulated weightlessness on the immune system in rats

Rats suspended in a model system designed to simulate many aspects of weightlessness were immunized with sheep red blood cells. Parameters measured on these and control rats included titers of anti-sheep red blood cell antibodies, serum immunoglobulin levels, spleen and thymus weights, hematocrits, and leukocyte differential counts on peripheral blood. No significant differences were found between test and weight-bearing, harnessed controls; however, the thymuses of animals in both these groups were significantly smaller than untreated cage controls. The lack of an effect of simulated weightlessness on the immune system is an interesting result, and its significance is discussed.

Caren, L. D.↗

Coil planet centrifugation as a means for small particle separation

The coil planet centrifuge uses a centrifugal force field to provide separation of particles based on differences in sedimentation rates by flow through a rotating coiled tube. Three main separations are considered: (1) single phase fresh sheep and human erythrocytes, (2) single phase fixed heep and human erythrocytes, and (3) electrophoretically enhanced single phase fresh sheep and human erythrocytes.

Herrmann, F. T.↗

Modelling global methane emissions from livestock: Biological and nutritional controls

The available observations of methane production from the literature have been compiled into a ruminant methane data base. This data base includes 400 treatment mean observations of methane losses from cattle and sheep, and minor numbers of measurements from other species. Methane loss varied from 2.0 to 11.6 percent of dietary gross energy. Measurements included describe the many different weights and physiological states of the animals fed and diets ranging from all forage to all concentrate diets or mixtures. An auxiliary spreadsheet lists approximately 1000 individual animal observations. Many important concepts have emerged from our query and analysis of this data set. The majority of the world's cattle, sheep, and goats under normal husbandry circumstances likely produce methane very close to 6 percent of their daily diets gross energy (2 percent of the diet by weight). Although individual animals or losses from specific dietary research circumstances can vary considerably, the average for the vast majority of groups of ruminant livestock are likely to fall between 5.5 to 6.5 percent. We must caution, however, that little experimental data is available for two-thirds of the world's ruminants in developing countries. Available evidence suggests similar percentage of emissions, but this supposition needs confirmation. More importantly, data is skimpy or unavailable to describe diet consumption, animal weight, and class distribution.

Johnson, Donald E.↗

Approach for Inferring Full-Scope Human Reliability Data Based on Simplified Simulator Data

This paper proposes a method for inferring full-scope human reliability data based on the Simplified Human Error Experimental Program (SHEEP) data. It mainly focuses on the human errors observed when using simulators with different complexity levels. In the proposed method, the manner in which human error probabilities (HEPs) change as a result of increasing simulator complexity and how simulator complexity levels are quantified represent key information for inferring full-scope data. In the present study, SHEEP error data pertaining to actual professional operators using Rancor Microworld (Rancor) (i.e., a more simplified simulator) and Compact Nuclear Simulator (CNS) (i.e., a less simplified simulator) were compared with the HuREX error data. An approach to quantifying simulator complexity levels was then proposed based on information theory and acquired eye-tracker data.

99 - GENERAL AND MISCELLANEOUS↗

A Feasibility Study on the Integration of Human Performance Data From Diverse Sources Based on the Complexity of a Proceduralized Task

Securing the safety of socio-technical systems including nuclear facilities is the upmost goal to ensure their sustainability because historical records demonstrate that the performance degradation of human operators (e.g., human errors) is one of the crucial contributors to the occurrence of unexpected events resulting in extensive casualties and financial losses. This implies that the collection of human performance data in diverse conditions with which they could be faced during the operation of nuclear facilities. As this collection requires significant resources, it is necessary to resolve how to accomplish it with limited resources. To address this challenge, as suggested in the SHEEP framework, it is indispensable to extract valuable insights after integrating various kinds of human performance data obtained from different sources. However, a practical method to soundly integrate them seems to be still incomplete. Accordingly, the applicability of TACOM (Task Complexity) measure is investigated as a tool to identify useful information based on the integration of human performance data observed from different simulation conditions. As a result, it is expected that the TACOM measure would play an important role in addressing the technical challenge in securing human performance data.

99 GENERAL AND MISCELLANEOUS↗

Pulmonary venous flow determinants of left atrial pressure under different loading conditions in a chronic animal model with mitral regurgitation

BACKGROUND: The aim of our study was to quantitatively compare the changes and correlations between pulmonary venous flow variables and mean left atrial pressure (mLAP) under different loading conditions in animals with chronic mitral regurgitation (MR) and without MR. METHODS: A total of 85 hemodynamic conditions were studied in 22 sheep, 12 without MR as control (NO-MR group) and 10 with MR (MR group). We obtained pulmonary venous flow systolic velocity (Sv) and diastolic velocity (Dv), Sv and Dv time integrals, their ratios (Sv/Dv and Sv/Dv time integral), mLAP, left ventricular end-diastolic pressure, and MR stroke volume. We also measured left atrial a, x, v, and y pressures and calculated the difference between v and y pressures. RESULTS: Average MR stroke volume was 10.6 +/- 4.3 mL/beat. There were good correlations between Sv (r = -0.64 and r = -0.59, P <.01), Sv/Dv (r = -0.62 and r = -0.74, P <.01), and mLAP in the MR and NO-MR groups, respectively. Correlations were also observed between Dv time integral (r = 0.61 and r = 0.57, P <.01) and left ventricular end-diastolic pressure in the MR and NO-MR groups. In velocity variables, Sv (r = -0.79, P <.001) was the best predictor of mLAP in both groups. The sensitivity and specificity of Sv = 0 in predicting mLAP 15 mm Hg or greater were 86% and 85%, respectively. CONCLUSION: Pulmonary venous flow variables correlated well with mLAP under altered loading conditions in the MR and NO-MR groups. They may be applied clinically as substitutes for invasively acquired indexes of mLAP to assess left atrial and left ventricular functional status.

Pulmonary Veins/physiopathology↗

Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure-volume relationship

OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.

Non-NASA Center↗

Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

Validation Studies↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗

Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: in vitro and in vivo studies

OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.

NASA Discipline Cardiopulmonary↗

Effects of proton and gamma radiation on lymphocyte populations and acute response to antigen

BACKGROUND: The clinical use of proton radiation in the management of cancer, as well as benign disorders, is rapidly increasing. The major goal of this study was to compare the effects of proton and gamma (60Co) radiation on cell-mediated and humoral immunological parameters. MATERIALS AND METHODS: C57BL/6 mice were exposed to a single dose of 3 Gray (Gy) protons or gamma-rays and intraperitoneally injected 1 day later with sheep red blood cells (sRBC). On 4, 10, 15, and 29 days after exposure, subsets from each group were euthanised; nonirradiated controls (with and without sRBC injection) were included. Body and relative spleen weights, leukocyte counts, spontaneous blastogenesis, lymphocyte populations, and anti-sRBC titers were evaluated. RESULTS: The data showed significant depression (p < 0.05) in nearly all assays on days 4 and 10 after irradiation. B lymphocytes (CD19+) were the most radiosensitive, although reconstitution back to normal levels was observed by day 15. T cell (CD3+) and T helper cell (CD4+) recovery was evident by day 29, whereas the T cytotoxic cell (CD8+) count remained significantly below normal. Natural killer cells (NK1.1+) were relatively radioresistant. Anti-sRBC antibody production was slow and low titers were obtained after irradiation. No significant differences were noted between the two types of radiation. CONCLUSIONS: Taken together, the data show that whole-body irradiation with protons or gamma-rays, at the dose employed, results in marked, but transient, immunosuppression. However, at the time points of testing and with the assays used, little or no differences were found between the two forms of radiation.

NASA Discipline Radiation Health↗

Validation of fluorescent-labeled microspheres for measurement of relative blood flow in severely injured lungs

The aim of the study was to validate a nonradioactive method for relative blood flow measurements in severely injured lungs that avoids labor-intensive tissue processing. The use of fluorescent-labeled microspheres was compared with the standard radiolabeled-microsphere method. In seven sheep, lung injury was established by using oleic acid. Five pairs of radio- and fluorescent-labeled microspheres were injected before and after established lung injury. Across all animals, 175 pieces were selected randomly. The radioactivity of each piece was determined by using a scintillation counter. The fluorescent dye was extracted from each piece with a solvent without digestion or filtering. The fluorescence was determined with an automated fluorescent spectrophotometer. Perfusion was calculated for each piece from both the radioactivity and fluorescence and volume normalized. Correlations between flow determined by the two methods were in the range from 0.987 +/- 0.007 (SD) to 0.991 +/- 0.002 (SD) after 9 days of soaking. Thus the fluorescent microsphere technique is a valuable tool for investigating regional perfusion in severely injured lungs and can replace radioactivity.

Non-NASA Center↗

New echocardiographic windows for quantitative determination of aortic regurgitation volume using color Doppler flow convergence and vena contracta

Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.

NASA Discipline Cardiopulmonary↗

Prolactin variants in ram adenohypophyses vary with season

Secretion of PRL in sheep is affected by photoperiod being highest during the spring and summer, lowest in fall and winter. The objectives of this study were to determine if 1) the production of variant forms of PRL, and 2) immuno- and bioactivities of PRL (iPRL and bPRL) differ during times of the year selected to represent periods of low, transitional and high PRL secretion. Twelve mature rams were maintained on pasture and killed in October, December, and April (n = 4/month). Individual pituitary glands were dispersed, cells obtained, and fixed for immunocytochemical flow cytometry, extracted with 0.01 N NaHCO3 or cultured in serum-free, defined media. The Mr of PRL extracted from cells immediately following dispersion ranged from 14-140K, with significantly more bands greater than 40K being detected from rams sacrificed in December than from those killed in October and April (P less than 0.01). No bands of PRL greater than 25K were observed when samples were reduced with beta-mercaptoethanol prior to electrophoresis, indicating that the high Mr forms were disulfide-linked aggregates. Culture media from October and April contained variants of PRL that ranged from 22-40K but those greater than 25K were generally not observed from cells harvested during December. Extracts of cells after 24 h in culture contained fewer high Mr species during December than had been present in initial extracts from that month. In contrast, during April more high Mr intracellular forms were present after culture than had been detected prior to culture during that month. The percentage of lactotrophs averaged 50.0 +/- 2.5, 47.4 +/- 5.7, and 59.4 +/- 5.5 for October, December, and April, respectively. Initial lactotroph content (pg/lactotroph) of iPRL was higher (P = 0.06) in April (46.0 +/- 17.0) when compared to October and December (8.0 +/- 2.0 and 20.0 +/- 10.0, respectively). In contrast, the bPRL content of initial extracts was higher (P = 0.05) in December (267.0 +/- 68.0) than in October (101.0 +/- 35.0), but not than in April (190.0 +/- 70.0). Although iPRL and bPRL concentrations in culture media were similar for the 3 months, the intracellular iPRL (P less than 0.001) and bPRL (P less than 0.0001) content after culture was greatest during April. In summary, in addition to the well-documented seasonal changes in blood concentrations of PRL, different molecular forms of PRL were found within the pituitary at different times of the year and seasonal variations in iPRL and bPRL did not occur in parallel.

Non-NASA Center↗

Structure and Sulfur: Tuning the Viscoelastic and Surface Properties of Natural Keratin Fibers

Natural keratin fibers, such as wool, possess a complex hierarchical structure that governs their mechanical properties and surface energy. However, the extent to which these characteristics are influenced by combined contributions of structural variations (e.g., fiber diameter, intermediate filament (IF) packing) and chemical composition (e.g., disulfide bond density) remains poorly understood. In this study, we investigate wool fibers from five sheep breeds (Merino, Polwarth, Cheviot, Eider, and Devon) to elucidate how these factors influence viscoelasticity and surface interactions. Using a multimodal approach integrating interfacial and bulk characterization methods, including inverse gas chromatography (IGC), atomic force microscopy-infrared spectroscopy (AFM-IR), X-ray photoelectron spectroscopy (XPS), uniaxial tensile testing, and synchrotron small-angle X-ray scattering (SAXS), we show that the nanometer-thick 18-methyleicosanoic acid (18-MEA) layer is consistently present across all wool types and plays a key role in governing hydrophobicity and surface heterogeneity. A controlled isothermal treatment at 200 °C, designed to cleave disulfide bonds, results in a nearly 40% reduction in specific surface area across all fiber types, accompanied by a significant decrease in tensile strength and 80% reduction in elongation at break for Merino and Devon wool, but limited influence on the mechanical properties of Eider fibers. Furthermore, rate-dependent tensile testing within the elastic regime reveals distinct viscoelastic responses among the fiber types, suggesting that the sulfur-rich protein matrix surrounding IFs and its structure contribute actively to stress partitioning. Altogether, when combined with conclusions from SAXS measurements of IF spacing, our work offers compelling insights into the role of the keratin-associated protein (KAP) matrix in shaping wool fiber mechanics. Differences in mechanical behavior among wool types, despite similar IF spacing or sulfur content, highlight the importance of matrix composition and cross-linking density, suggesting that the molecular architecture of the KAP network may be a dominant factor in determining fiber performance.

X-ray scattering↗