Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon photodiode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Numerical Examination of Silicon Avalanche Photodiodes Operated in Charge Storage Mode

The behavior of silicon-based avalanche photodiodes (APD's) operated in the charge storage mode is examined. In the charge storage mode, the diodes are periodically biased to a sub-breakdown voltage and then open-circuited. During this integration period, photo-excited and thermally generated carriers are accumulated within the structure. The dynamics of this accumulation and its effects upon the avalanching of the diode warrants a detailed, fully numerical analysis. The salient features of this investigation include device sensitivity to the input photo-current including the self-quenching effect of the diode and its limitations in sensing low light levels, the dependence of the response on the bulk lifetime and hence on the generation current within the device, the initial gain, transient response, dependence of the device uniformity upon performance, and the quantity of storable charge within the device. To achieve these tasks our device simulator, STEBS-2D, was utilized. A modified current-controlled boundary condition is employed which allows for the simulation of the isolated diode after the initial reset bias has been applied. With this boundary condition, it is possible to establish a steady-state voltage on the ohmic contact and then effectively remove the device from the external circuit while still including effects from surface recombination, trapped surface charge, and leakage current from the read-out electronics.

Parks, Joseph W., Jr.↗

32 Gbps heterogeneously integrated quantum dot waveguide avalanche photodiodes on silicon

We report a heterogeneous GaAs-based quantum dot (QD) avalanche photodiode (APD) on silicon with an ultralow dark current of 10 pA at − <#comment/> 1 V , 3 dB bandwidth of 20 GHz and record gain-bandwidth product (GBP) of 585 GHz. Furthermore, open eye diagrams up to 32 Gb/s are demonstrated at 1310 nm. The k-factor has been measured for these devices to be as low as 0.14. A polarization dependence on gain and bandwidth has been observed and investigated. This shows the potential to integrate a high-speed receiver in a wavelength division multiplexing (WDM) system on a QD-based silicon photonics platform.

Tossoun, Bassem↗

Predictions of silicon avalanche photodiode detector performance in water vapor differential absorption lidar

Performance analyses are presented which establish that over most of the range of signals expected for a down-looking differential absorption lidar (DIAL) operated at 16 km the silicon avalanche photodiode (APD) is the preferred detector for DIAL measurements of atmospheric water vapor in the 730 nm spectral region. The higher quantum efficiency of the APD's, (0.8-0.9) compared to a photomultiplier's (0.04-0.18) more than offsets the higher noise of an APD receiver. In addition to offering lower noise and hence lower random error the APD's excellent linearity and impulse recovery minimize DIAL systematic errors attributable to the detector. Estimates of the effect of detector system parameters on overall random and systematic DIAL errors are presented, and performance predictions are supported by laboratory characterization data for an APD receiver system.

Kenimer, R. L.↗

Bias-dependent displacement damage effects in a silicon avalanche photodiode

Radiation effects studies on a commercial beveled-edge avalanche photodiode (APD) showed that applying reverse bias to the device during irradiation enhanced the severity of apparent damage. Proton microbeam irradiations were made using a proton beam energy of 2 MeV and fluence ranging from 2.0 × 10 10 to 5.1 × 10 12 cm -2 . Charge collection measurements using the ion beam induced charge (IBIC) technique showed that relative losses increased by up to an order of magnitude when the reverse bias applied during irradiation increased from 50 to 1500 V. The presence of reverse bias also led to equivalent losses in charge collection that would only be seen in irradiations with an order of magnitude higher fluence in unbiased APDs. The results demonstrate that bias-enhanced irradiation damage is insufficiently understood and must be accounted for in characterizations of radiation effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effect of Radiation Damage on the Charge Collection Efficiency of Silicon Avalanche Photodiodes

Understanding radiation effects on avalanche photodiodes (APDs) is important because they are used in several applications involving harsh radiation environments. APDs are used as photosensors in applications where speed and detection efficiency are critical. Proton irradiation experiments on a commercial off-the-shelf APD demonstrated that the irradiation flux and applied reverse bias have a strong influence on the severity of radiation effects. This is measured using the ion beam induced charge (IBIC) technique in which charge collection efficiency (CCE) describes the signal response from a device. CCE can degrade substantially due to radiation damage, but recent measurements show that certain combinations of irradiation flux and reverse bias can lead to increases in CCE up to 186% ± 24% for irradiations with 2 MeV protons at a fluence of 6.4 × 10 11 cm –2 . This defect-enhanced charge multiplication (DECM) only appeared when the reverse bias during irradiation ranged from 170 to 1830 V out of a maximum operating bias of 2000 V and the proton flux ranged from 9.8 × 10 7 to 3.4 × 10 9 cm –2 s –1 . Furthermore values outside of either range led to losses in CCE. It is expected that DECM should be encountered in other devices, especially those with sufficiently high electric fields to cause impact ionization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical and electrical measurements on UV sensitive photodiodes

The optical and electrical characteristics of the various types of photodiodes potentially useful for UV radiometers were studied. It was concluded that both GaAsP and GaP photodiodes have advantages over silicon photodiodes in terms of spectral response and UV stability. Both GaAsP and GaP have excellent electrical characteristics for low frequency radiometers, although their high capacitance could be inconvenient for high frequency applications. GaAsP is particularly good with respect to dynamic range.

Lyall, H.↗

Photon counting modules using RCA silicon avalanche photodiodes

Avalanche photodiodes (APD) are excellent small area, solid state detectors for photon counting. Performance possibilities include: photon detection efficiency in excess of 50 percent; wavelength response from 400 to 1000 nm; count rate to 10 (exp 7) counts per sec; afterpulsing at negligible levels; timing resolution better than 1 ns. Unfortunately, these performance levels are not simultaneously available in a single detector amplifier configuration. By considering theoretical performance predictions and previous and new measurements of APD performance, the anticipated performance of a range of proposed APD-based photon counting modules is derived.

Lightstone, Alexander W.↗

Photodiode and photomultiplier areal sensitivity anomalies

Several silicon photodiodes and photomultipliers were tested to determine signal variations as a light spot was scanned over the photosensitive surface of these detectors. Qualitative and quantitative data is presented to demonstrate the areal sensitivity anomalies. These anomalies are related back to the fabrication techniques of the manufacturers.

Youngbluth, O., Jr.↗

A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

State of technology in optical systems

The use of silicon photodiode sensors and locator systems for lightning experiments is discussed. Tables are presented on: (1) satellite optical lightning experiments (silicon detectors); (2) reticon photodiode linear arrays; and (3) locator systems (grey code and reticon). An illustration of a grey code locator system for a low altitude satellite is also given.

Edgar, B. C.↗

Fast photodiode arrays for high frequency fluctuation measurements of reconnecting flux ropes

An array of compact, high-bandwidth (>200 MHz) and low-cost optical photodiodes has been developed and implemented on the PHASe MApping (PHASMA) experiment. Using purpose-built electronics, an array of 16 photodetectors was constructed and used to monitor broadband (1–5 MHz) fluctuations in light intensity emitted by flux ropes undergoing electron-only magnetic reconnection. These measurements reveal a swath of oscillatory behavior, including wave propagation inward toward the diffusion region at approximately the local electron Alfvén speed. Custom 3D-printed collection optics and mounting hardware allow quick reconfiguration of the array for radial or axial measurements. The electronics design is flexible enough to be used with other current-sourcing transducers, such as avalanche photodiodes; silicon photomultipliers; and infrared, x-ray, and UV photodiodes. A noise-rejecting electrical layout allows for low-noise operation close to pulsed plasma discharges. A 16-channel, 64-pixel tomographic array was constructed and initial reconstructions are presented.

Instruments & Instrumentation↗

Ultraviolet corona detection sensor study

The feasibility of detecting electrical corona discharge phenomena in a space simulation chamber via emission of ultraviolet light was evaluated. A corona simulator, with a hemispherically capped point to plane electrode geometry, was used to generate corona glows over a wide range of pressure, voltage, current, electrode gap length and electrode point radius. Several ultraviolet detectors, including a copper cathode gas discharge tube and a UV enhanced silicon photodiode detector, were evaluated in the course of the spectral intensity measurements. The performance of both silicon target vidicons and silicon intensified target vidicons was evaluated analytically using the data generated by the spectroradiometer scans and the performance data supplied by the manufacturers.

Schmitt, R. J.↗

Self-scanned photodiode array - High performance operation in high dispersion astronomical spectrophotometry

A multichannel spectrophotometric detector system has been developed using a 1024 element self-scanned silicon photodiode array, which is now in routine operation with the high-dispersion coude spectrograph of the University of Texas McDonald Observatory 2.7-m telescope. Operational considerations in the use of such arrays for high precision and low light level spectrophotometry are discussed. A detailed description of the system is presented. Performance of the detector as measured in the laboratory and on astronomical program objects is described, and it is shown that these arrays are highly effective detectors for high dispersion astronomical spectroscopy.

Vogt, S. S.↗

Photodiodes for Astronomical Stellar Radiometry

The theory of photodiodes and their application to radiometric measurements is reviewed. Some suggestions concerning photodiode detectors for use in stellar radiometric measurements are given. Quantum efficiency, linear response characteristics, and noise current values of silicon photodiodes are considered.

Schaefer, A. R.↗

Photodiode-Based, Passive Ultraviolet Dosimeters

Simple, passive instruments have been developed for measuring the exposure of material specimens to vacuum ultraviolet (VUV) radiation from the Sun. Each instrument contains a silicon photodiode and a coulometer. The photocharge generated in the photodiode is stored in the coulometer. The accumulated electric charge measured by use of the coulometer is assumed to be proportional to the cumulative dose of VUV radiation expressed in such convenient units as equivalent Sun hours (ESH) [defined as the number of hours of exposure to sunlight at normal incidence]. Intended originally for use aboard spacecraft, these instruments could also be adapted to such terrestrial uses as monitoring the curing of ultraviolet-curable epoxies. Each instrument includes a photodiode and a coulometer assembly mounted on an interface plate (see figure). The photodiode assembly includes an aluminum housing that holds the photodiode, a poly(tetrafluoroehylene) cosine receptor, and a narrow-band optical filter. The cosine receptor ensures that the angular response of the instrument approximates the ideal angular response (proportional to the cosine of the angle of incidence). The filter is chosen to pass the ultraviolet wavelength of interest in a specific experiment. The photodiode is electrically connected to the coulometer. The factor of proportionality between the charge stored in the coulometer and ultraviolet dosage (in units of ESH) is established, prior to use, in calibration experiments that involve the use of lamps and current sources traceable to the National Institute of Standards and Technology.

Vaughn, Jason A.↗