Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stark effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

On the Stark effect in open shell complexes exhibiting partially quenched electronic angular momentum: Infrared laser Stark spectroscopy of OH–C 2 H 2 , OH–C 2 H 4 , and OH–H 2 O

The Stark effect is considered for polyatomic open shell complexes that exhibit partially quenched electronic angular momentum. Matrix elements of the Stark Hamiltonian represented in a parity conserving Hund's case (a) basis are derived for the most general case, in which the permanent dipole moment has projections on all three inertial axes of the system. Transition intensities are derived, again for the most general case, in which the laser polarization has projections onto axes parallel and perpendicular to the Stark electric field, and the transition dipole moment vector is projected onto all three inertial axes in the molecular frame. As a result, simulations derived from this model are compared to experimental rovibrational Stark spectra of OH-C 2 H 2 , OH-C 2 H 4 , and OH-H 2 O complexes formed in helium nanodroplets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic fluctuation profile measurement using optics of motional Stark effect diagnostics in JT-60U

Motional Stark effect (MSE) diagnostics in JT-60U works as polarimeter to measure the pitch angle of magnetic field as well as beam-emission-spectroscopy (BES) monochromator simultaneously at 30 spatial channels. Fluctuation in the BES signal using MSE optics (MSE/BES) contains fluctuations in not only the density but also the pitch angle (or the magnetic field). Correlation analysis of the magnetic fluctuation between two spatial channels is applied to high-beta plasma with a magnetohydrodynamic activity at frequency of about 0.9 kHz. It has been found that the magnetic fluctuation measured by the MSE/BES is spatially localized near the magnetic flux surface having safety factor and that the phase of the fluctuation is inverted at about the surface, suggesting magnetic island structure by tearing mode. The phase of the magnetic fluctuation measured by the MSE/BES at outside of the q=2 surface is consistent with that by the pickup coil placed outside the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large polarization-dependent exciton optical Stark effect in lead iodide perovskites

A strong interaction of a semiconductor with a below-bandgap laser pulse causes a blue-shift of the bandgap transition energy, known as the optical Stark effect. The energy shift persists only during the pulse duration with an instantaneous response time. The optical Stark effect has practical relevance for applications, including quantum information processing and communication, and passively mode-locked femtosecond lasers. Here we demonstrate that solution-processable lead-halide perovskites exhibit a large optical Stark effect that is easily resolved at room temperature resulting from the sharp excitonic feature near the bandedge. We also demonstrate that a polarized pump pulse selectively shifts one spin state producing a spin splitting of the degenerate excitonic states. Such selective spin manipulation is an important prerequisite for spintronic applications. Lastly, our result implies that such hybrid semiconductors may have great potential for optoelectronic applications beyond photovoltaics.

14 SOLAR ENERGY↗

Four-dimensional calibration turntable of the motional Stark effect diagnostic on EAST

The motional Stark effect (MSE) diagnostic is applied to measure the safety factor q and current density profile of a tokamak device, which are important parameters in realizing the high-performance and long-pulse steady state of a tokamak. A single-channel MSE diagnostic based on dual photoelastic modulators, whose sightline meets with the neutral beam injection at a major radius of R = 2.12 m, has been built for the D window of the Experimental Advanced Superconducting Tokamak (EAST). According to the requirements of MSE diagnostic polarimetric calibration, a high-precision four-dimensional calibration turntable, driven by four stepping motors and controlled by software running on the computer, was designed for EAST. The turntable allows us to rapidly calibrate the MSE diagnostic in a series of positions and angles during EAST maintenance. The turntable can move in four dimensions of translation, yaw, pitch, and roll of the polarizer and can create linearly polarized light at any given angle with accuracy of ~0.05° for the MSE system offline calibration. As a result, the experimental results of the MSE diagnostic calibration in the laboratory show that the turntable has the advantages of high positioning accuracy, flexible spatial movement, and convenient control and fully meets the calibration requirements of an MSE diagnosis system.

47 OTHER INSTRUMENTATION↗

Stark effect in He II and H

Stark effect He II and H beta on lines observed for transverse and longitudinal fields, using beam-foil light source

Bashkin, S.↗

The AC-Stark Effect in Nitric Oxide Induced by Rapidly Swept Continuous Wave Quantum Cascade Lasers

A large AC Stark effect has been observed when nitric oxide, at low pressure in a long optical path (100 m) Herriot cell, is subjected to infrared radiation from a rapidly swept, continuous wave infrared quantum cascade laser. As the frequency sweep rate of the laser is increased, an emission signal induced by rapid passage, occurs after the laser frequency has passed through the resonance of a molecular absorption line. At very high sweep rates a laser field-induced splitting of the absorptive part of the signal is observed, due to the AC Stark effect. This splitting is related to the Autler-Townes mixing of the hyperfine transitions, which lie within the lambda doublet components of the transition, under the Doppler broadened envelope.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stark effect at the Si I series limit

Small redshifts and weakenings of high n lines in members of the Si series observed over a sunspot are interpreted as due to the Stark effect. Other origins, including Doppler motions, appear to be excluded. The spectra were obtained with high spatial resolution using the NRL high-resolution telescope and spectrograph. The origin of the Stark effect is not yet certain. An interpretation in terms of a quasi-static quadratic effect would require rather high perturber densities. An alternative interpretation would be a motional Stark effect, arising perhaps through the presence of magnetohydrodynamic waves.

Jordan, C.↗

Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The motional Stark effect diagnostic for ITER

An overview of the plans for the motional Stark effect (MSE) diagnostic installation on the International Thermonuclear Experimental Reactor (ITER) is presented. The MSE diagnostic uniquely provides spatially localized magnetic field measurements inside the plasma. These are used to constrain equilibrium reconstructions to determine q(r), the safety factor as a function of minor radius. Meeting the system requirements to deliver q-profiles and related quantities with the specified radial resolution of 20 points over the minor radius, 10 ms time resolution, and better than 10% accuracy is challenging. MSE systems observe the D/H-α emission near 656.3 nm from neutral beams. As the beam atoms traverse the magnetic field, B⃗, at high velocity, v⃗, they experience a Lorentz electric field, v⃗×B⃗, which causes the spectral emission to be split and polarized due to the Stark effect. Traditional MSE-LP (line polarization) measurements determine the direction of the magnetic field in the observation volume using polarimetric analysis of the detected light. The harsh conditions of ITER are expected to deposit thin films of contaminants on the first mirror, which would alter the polarization state of reflected light significantly. On ITER, the combination of high magnetic field strength and high energy beams makes the Stark spectrum resolution suitable for the determination of the magnetic field magnitude from the line shift, so this approach has been selected. Every aspect of the measurement system must be planned for the burning plasma environment and carefully analyzed ahead of time. Current status and plans for the system are presented.

Instruments & Instrumentation↗

Spectrally resolved motional Stark effect measurements on ASDEX Upgrade

A spectrally resolved Motional Stark Effect (MSE) diagnostic has been installed at ASDEX Upgrade. The MSE data have been fitted by a forward model providing access to information about the magnetic field in the plasma interior [R. Reimer, A. Dinklage, J. Geiger et al., Contrib. Plasma Phys. 50, 731–735 (2010)]. The forward model for the beam emission spectra comprises also the fast ion D{sub α} signal [W. W. Heidbrink and G. J. Sadler, Nucl. Fusion 34, 535–615 (1994)] and the smearing on the CCD-chip. The calculated magnetic field data as well as the revealed (dia)magnetic effects are consistent with the results from equilibrium reconstruction solver. Measurements of the direction of the magnetic field are affected by unknown and varying polarization effects in the observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Basic characteristics of high-frequency Stark-effect modulation of CO2 lasers.

The molecular Stark effect and its application to the modulation of infrared laser radiation have been investigated both theoretically and experimentally. Using a density matrix approach, a quantum mechanical description of the effect of a time-varying electric field on the absorption coefficient and refractive index of a molecular gas near an absorption line has been formulated. For modulation applications a quantity known as the ?modulation depth' is of prime importance. Theoretical expressions for the frequency dependence of the modulation depth show that the response to the frequency of a time-varying Stark field is separated into a nondispersive and a dispersive region, depending on whether the modulating frequency is less than or greater than the homogeneous absorption linewidth. Experimental results showing nondispersive modulation at frequencies to 30 MHz are presented. In addition it is shown that the response of modulation depth to Stark field amplitude is separated into linear and nonlinear regions, the field at which nonlinearities begin being determined by the absorption spectrum of the molecule being used.

Claspy, P. C.↗

Laser control of the radiationless decay in pyrazine using the dynamic Stark effect

The laser control of the radiationless decay between the B{sub 3u}(nπ*) and B{sub 2u}(ππ*) states of pyrazine using the dynamic Stark effect has been investigated. A vibronic coupling model Hamiltonian in diabatic representation, including potential energy, transition dipole, and static polarizability surfaces as a function of the four most important vibrational modes of the molecule has been parametrized using multi-reference electronic structure calculations. The interaction of the molecule with a strong non-resonant laser pulse has been analyzed in terms of dressed potential energy surfaces. Because of the large polarizability difference between the vibronically coupled B{sub 3u}(nπ*) and B{sub 2u}(ππ*) states, the Stark effect induced by the non-resonant laser pulse shifts the conical intersection away from the Franck-Condon region. We have shown, by solving the time-dependent Schrödinger equation for the molecule interacting with a relatively weak pump pulse driving the electronic excitation from the ground state to the B{sub 2u}(ππ*) state, and a strong non-resonant control pulse, that this control mechanism can be used to trap the wavepacket on the B{sub 2u}(ππ*) potential energy surface for a much longer time than the natural B{sub 2u}(ππ*) lifetime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of the motional Stark effect diagnostic gas-filled torus calibration

Many motional Stark effect diagnostics around the world make use of a calibration procedure in which the observed neutral beam is injected into a gas-filled torus with known vacuum fields. The instrument is calibrated by reconciling measured angles with vacuum magnetic reconstructions through a range of pitch angles. This in situ gas-filled torus calibration most closely approximates the working conditions of the diagnostic and includes effects such as beam and viewing geometries, beam voltages, Faraday and stress induced birefringence (in most cases) of the transmissive optics, as well as the polarimeter response. However, secondary neutrals, produced after ionization then reneutralization of a beam neutral, have been found to contaminate measured angles by emitting Balmer alpha with similar Doppler shifts and Stark polarizations as beam neutrals, but with different polarization angles. Simulation results that show spectral and angle behavior versus calibration parameters such as fill gas pressure will be presented. Data from NSTX and C-Mod will be compared to simulations results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Full-dimensional control of the radiationless decay in pyrazine using the dynamic Stark effect

We present a full quantum-mechanical study of the laser control of the radiationless decay between the B{sub 3u}(nπ{sup *}) and B{sub 2u}(ππ{sup *}) states of pyrazine using the dynamic Stark effect. In contrast to our previous study [Sala et al., J. Chem. Phys. 140, 194309 (2014)], where a four-dimensional model was used, all the 24 degrees of freedom are now included in order to test the robustness of the strategy of control. Using a vibronic coupling Hamiltonian model in a diabatic representation, the multi-layer version of the multi-configuration time-dependent Hartree method is exploited to propagate the corresponding wave packets. We still observe a trapping of the wavepacket on the B{sub 2u}(ππ{sup *}) potential energy surface due to the Stark effect for a longer time than the “non-resonant field-free” B{sub 2u}(ππ{sup *}) lifetime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stark effect spectrophone for continuous absorption spectra monitoring

A Stark effect spectrophone using a pulsed or continuous wave laser having a beam with one or more absorption lines of a constituent of an unknown gas is described. The laser beam is directed through windows of a closed cell while the unknown gas to be modified flows continuously through the cell between electric field plates disposed in the cell on opposite sides of the beam path through the cell. When the beam is pulsed, energy absorbed by the gas increases at each point along the beam path according to the spectral lines of the constituents of the gas for the particular field strengths at those points. The pressure measurement at each point during each pulse of energy yields a plot of absorption as a function of electric field for simultaneous detection of the gas constituents. Provision for signal averaging and modulation is included.

Kavaya, M. J.↗