At least 37 records · Page 2

Time-resolved photoelectron spectroscopy via trajectory surface hopping

Time-resolved photoelectron spectroscopy is a powerful pump-probe technique which can probe nonadiabatic dynamics in molecules. Interpretation of the experimental signals however requires input from theoretical simulations. Advances in electronic structure theory, nonadiabatic dynamics, and theory to calculate the ionization yields, have enabled accurate simulation of time-resolved photoelectron spectra leading to successful applications of the technique. Here, we review the basic theory and steps involved in calculating time-resolved photoelectron spectra, and highlight successful applications.

Chakraborty, Pratip↗

Examination of Lunar Regolith Simulants By SEM-EDS and Imaging Raman Spectroscopy

The Artemis series lunar missions will include sample returns from the lunar south pole. Lunar regolith simulants (RS) generated in the lab provide opportunities to compare two surface science techniques: scanning electron microscopy (SEM-EDS) and Raman induced surface spectroscopy. The results will also be applicable for supporting future commercial lunar payload services (CLPS) and Artemis surface. Surface characterization contributes to continued development of lunar regolith studies and adds to various regolith databases. In characterizing various lunar regolith simulants, part of the aim should be to standardize techniques and utilize anticipated methods available for astromaterials studied during, or returned from, upcoming missions, particularly samples collected from the Moon’s south pole and permanently shadowed regions (PSRs).. An initial survey of available simulants has been started with Raman scanning process for particle counting the results of which will enrich the NASA-JSC Simulant Development Lab (SDL) simulant properties database and the Colorado School of Mines Planetary Simulant Data Base. An SEM-EDS dataset of raw regolith simulant materials are collected.

Raman Microscopy↗

Stability and rheology of dispersions of silicon nitride and silicon carbide

The relationship between the surface and colloid chemistry of commercial ultra-fine silicon carbide and silicon nitride powders was examined by a variety of standard characterization techniques and by methodologies especially developed for ceramic dispersions. These include electrokinetic measurement, surface titration, and surface spectroscopies. The effects of powder pretreatment and modification strategies, which can be utilized to augment control of processing characteristics, were monitored with these technologies. Both silicon carbide and nitride were found to exhibit silica-like surface chemistries, but silicon nitride powders possess an additional amine surface functionality. Colloidal characteristics of the various nitride powders in aqueous suspension is believed to be highly dependent on the relative amounts of the two types of surface groups, which in turn is determined by the powder synthesis route. The differences in the apparent colloidal characteristics for silicon nitride powders cannot be attributed to the specific absorption of ammonium ions. Development of a model for the prediction of double-layer characteristics of materials with a hybrid site interface facilitated understanding and prediction of the behavior of both surface charge and surface potential for these materials. The utility of the model in application to silicon nitride powders was demonstrated.

Feke, Donald L.↗

Thermal effects in equilibrium surface segregation in a copper/10-atomic-percent-aluminum alloy using Auger electron spectroscopy

Equilibrium surface segregation of aluminum in a copper-10-atomic-percent-aluminum single crystal alloy oriented in the /111/ direction was demonstrated by using Auger electron spectroscopy. This crystal was in the solid solution range of composition. Equilibrium surface segregation was verified by observing that the aluminum surface concentration varied reversibly with temperature in the range 550 to 850 K. These results were curve fitted to an expression for equilibrium grain boundary segregation and gave a retrieval energy of 5780 J/mole (1380 cal/mole) and a maximum frozen-in surface coverage three times the bulk layer concentration. Analyses concerning the relative merits of sputtering calibration and the effects of evaporation are also included.

Ferrante, J.↗

Secondary Electron Emission Spectroscopy of Diamond Surfaces

This report presents the results of the secondary electron emission spectroscopy study of hydrogenated diamond surfaces for single crystals and chemical vapor-deposited polycrystalline films. One-electron calculations of Auger spectra of diamond surfaces having various hydrogen coverages are presented, the major features of the experimental spectra are explained, and a theoretical model for Auger spectra of hydrogenated diamond surfaces is proposed. An energy shift and a change in the line shape of the carbon core-valence-valence (KVV) Auger spectra were observed for diamond surfaces after exposure to an electron beam or by annealing at temperatures higher than 950 C. This change is related to the redistribution of the valence-band local density of states caused by hydrogen desorption from the surface. A strong negative electron affinity (NEA) effect, which appeared as a large, narrow peak in the low-energy portion of the spectrum of the secondary electron energy distribution, was also observed on the diamond surfaces. A fine structure in this peak, which was found for the first time, reflected the energy structure of the bottom of the conduction band. Further, the breakup of the bulk excitons at the surface during secondary electron emission was attributed to one of the features of this structure. The study demonstrated that the NEA type depends on the extent of hydrogen coverage of the diamond surface, changing from the true type for the completely hydrogenated surface to the effective type for the partially hydrogenated surface.

Krainsky, Isay L.↗

Subsurface Spectroscopy in Heterogeneous Materials Using Self-Healing Laser Beams

Self-healing optical beams are a class of propagation modes that can recover their beam shapes after distortion or partial blockage. This self-healing property makes them attractive for use in applications involving turbid media as they can—in theory—penetrate further into these materials than standard Gaussian beams. In this paper, we characterize the propagation of two different self-healing beams (Bessel and Airy) through a solid scattering material with different scatterer concentrations and find that both beams do recover after scattering for samples below a threshold scatterer concentration. Additionally, we test the applicability of both beam shapes for improved sub-surface spectroscopy in heterogeneous materials using fluorescent particles and find that there is an average fluorescence intensity enhancement of 1.3× using self-healing beams versus a standard Gaussian beam.

47 OTHER INSTRUMENTATION↗

New Material for Surface-Enhanced Raman Spectroscopy

A chemical method of synthesis and application of coating materials that are especially suitable for surface-enhanced Raman spectroscopy (SERS) has been developed. The purpose of this development is to facilitate the utilization of the inherently high sensitivity of SERS to detect chemicals of interest (analytes) in trace amounts, without need for lengthy sample preparation. Up to now, the use of SERS has not become routine because the methods available have not been able to reproduce sampling conditions and provide quantitative measurements. In contrast, the coating materials of the present method enable analysis with minimum preparation of samples, and SERS measurements made using these materials are reproducible and reversible. Moreover, unlike in methods investigated in prior efforts to implement SERS, sampling is not restricted to such specific environments as electrolytes or specific solvents. The coating materials of this method are porous glasses, formed in sol-gel processes, that contain small particles of gold or silver metal. Materials of this type can be applied to the sample-contact surfaces of a variety of sampling and sensing devices, including glass slides, glass vials, fiber-optic probes, and glass tubes. Glass vials with their insides coated according to this method are particularly convenient for SERS to detect trace chemicals in solutions: One simply puts a sample solution containing the analyte(s) into a vial, then puts the vial into a Raman spectrometer for analysis. The chemical ingredients and the physical conditions of the sol-gel process have been selected so that the porous glass formed incorporates particles of the desired metal with size(s) to match the wavelength(s) of the SERS excitation laser in order to optimize the generation of surface plasmons. The ingredients and processing conditions have further been chosen to tailor the porosity and polarity of the glass to optimize the sample flow and the interaction between the analyte(s) and the plasmon field that generates Raman photons. The porous silica network of a sol-gel glass creates a unique environment for stabilizing SERS-active metal particles. Relative to other material structures that could be considered for SERS, the porous silica network offers higher specific surface area and thus greater interaction between analyte molecules and metal particles. Efforts to perform SERS measurements with the help of sampling devices coated by this method have been successful. In tests, numerous organic and inorganic chemicals were analyzed in several solvents, including water. The results of the tests indicate that the SERS measurements were reproducible within 10 percent and linear over five orders of magnitude. One measure of the limits of detectability of chemicals in these tests was found to be a concentration of 300 parts per billion. Further development may eventually make it possible to realize the full potential sensitivity of SERS for detecting some analytes in quantities as small as a single molecule.

Farquharson, Stuart↗

Water structure and electric fields at the interface of oil droplets

Interfacial water exhibits rich and complex behaviour, playing an important part in chemistry, biology, geology and engineering. However, there is still much debate on the fundamental properties of water at hydrophobic interfaces, such as orientational ordering, the concentration of hydronium and hydroxide, improper hydrogen bonds and the presence of large electric fields. This controversy arises from the challenges in measuring interfacial systems, even with the most advanced experimental techniques and theoretical approaches available. Here we report on an in-solution, interface-selective Raman spectroscopy method using multivariate curve resolution to probe hexadecane-in-water emulsions, aided by a monomer-field theoretical model for Raman spectroscopy. Our results indicate that oil-water emulsion interfaces can exhibit reduced tetrahedral order and weaker hydrogen bonding, along with a substantial population of free hydroxyl groups that experience about 95 cm -1 redshift in their stretching mode compared with planar oil-water interfaces. Given the known electrostatic zeta potential characteristic of oil droplets, we propose the existence of a strong electric field (about 50-90 MV cm -1 ) emanating from the oil phase. This field is inferred indirectly but supported by control experiments and theoretical estimates. These observations are either absent or opposite in the molecular hydrophobic interface formed by small solutes or at planar oil-water interfaces. Instead, water structural disorder and enhanced electric fields emerge as unique features of the mesoscale interface in oil-water emulsions, potentially contributing to the accelerated chemical reactivity observed at hydrophobic-water interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lanthanide binding peptide surfactants at air–aqueous interfaces for interfacial separation of rare earth elements

Rare earth elements (REEs) are critical materials to modern technologies. They are obtained by selective separation from mining feedstocks consisting of mixtures of their trivalent cation. We are developing an all-aqueous, bioinspired, interfacial separation using peptides as amphiphilic molecular extractants. Lanthanide binding tags (LBTs) are amphiphilic peptide sequences based on the EF-hand metal binding loops of calcium-binding proteins which complex selectively REEs. We study LBTs optimized for coordination to Tb 3+ using luminescence spectroscopy, surface tensiometry, X-ray reflectivity, and X-ray fluorescence near total reflection, and find that these LBTs capture Tb 3+ in bulk and adsorb the complex to the interface. Molecular dynamics show that the binding pocket remains intact upon adsorption. We find that, if the net negative charge on the peptide results in a negatively charged complex, excess cations are recruited to the interface by nonselective Coulombic interactions that compromise selective REE capture. If, however, the net negative charge on the peptide is −3, resulting in a neutral complex, a 1:1 surface ratio of cation to peptide is achieved. Surface adsorption of the neutral peptide complexes from an equimolar mixture of Tb 3+ and La 3+ demonstrates a switchable platform dictated by bulk and interfacial effects. The adsorption layer becomes enriched in the favored Tb 3+ when the bulk peptide is saturated, but selective to La 3+ for undersaturation due to a higher surface activity of the La 3+ complex.

Ortuno Macias, Luis E. (ORCID:0000000284342192)↗

Chemical structure of interfaces

The interfacial structure of silicon/dielectric and silicon/metal systems is particularly amenable to analysis using a combination of surface spectroscopies together with a variety of chemical structures of Si/SiO2, Si/SiO2Si3N4, Si/Si2N2O, Si/SiO2/Al, and Si/Native Oxide interfaces using high resolution (0.350 eV FWHM) X ray photoelectron spectroscopy. The general structure of these dielectric interfaces entails a monolayer chemical transition layer at the Si/dielectric boundary. Amorphous Si substrates show a wide variety of hydrogenated Si and Si(OH) sub x states that are not observed in thermal oxidation of single crystal material. Extended SiO2 layers greater than 8 A in thickness are shown to be stoichiometric SiO2, but to exhibit a wide variety of local network structures. In the nitrogen containing systems, an approach to stoichiometric oxynitride compounds with interesting impurity and electron trapping properties are seen. In native oxides, substantial topographical nonuniformity in oxide thickness and composition are found. Analysis of metal/oxide interfacial layers is accomplished by analytical removal of the Si substrate by UHV XeF2 dry etching methods.

Grunthaner, F. J.↗

Analysis of Black Bearing Balls from a Space Shuttle Body Flap Actuator

A significantly deteriorated ball bearing mechanism from a body flap actuator on Space Shuttle OV-103 was disassembled and the balls submitted for analysis in conjunction with Return to Flight activities. The OV-103 balls, referred to as the "black balls", were subjected to X-ray photoelectron spectroscopy (XPS), Fourier transform infrared (FT-IR) and Raman micro spectroscopy, surface profilometry, and optical and electron microscopy. The spectroscopic results in combination with microscopy analysis allowed a determination of the lubricant degradation pathway. The chemical attack mechanism does not adequately explain the unique visual appearance of the black balls. Numerous efforts have unsuccessfully focused on duplication of the phenomena causing this unique surface structure and appearance of the black balls. Further detail will be presented supporting these conclusions along with plausible explanations of the unique black appearance to the balls.

Sovinski, Marjorie F.↗

Thermal infrared emission spectroscopy of natural surfaces: Application to desert varnish coatings on rocks

Thermal infrared spectroscopy has become an increasingly important tool for remote compositional analysis and geologic mapping. Most published laboratory measurements have been obtained in bidirectional reflection or transmission, whereas remotely sensed thermal infrared data are obtained by measuring the emitted energy. Section 2 of this paper describes a laboratory technique for determining calibrated emissivities of natural surfaces. Equations are developed to account for the energy reflected from the environment and to determine directly the sample temperature from measurements of hot and cold blackbody targets. Two methods for determining emissivity are developed: one in which only a hot sample measurement is made and the reflected background energy is removed by modeling, and a second in which the sample is cooled and the reflected energy is measured directly. Relative emissivity can be obtained to approximately 1% and absolute emissivities can be obtained to 2-15%, depending on the validity of the assumption that the emissivity of the sample is unity at some wavelength. The emission data agree well within the hemispherically integrated reflection data but point out probelms associated with bidirectional reflectance measurements. Section 3 applies emissivity measurements to the study of layered surfaces consisting of desert varnish coatings on granite and granodiorite rock suites. Two linear models are developed: the first assumes linear mixing of independent emission from the substrate and varnish (checkerboard model); the second models tansmission through an absorbing/emitting medium. Regardless of whether the varnish is or is not relatively transparant and strongly absorptive, the spectral effect of varnish increases linearly with varnish thickness, indicating that thick patches of varnish dominate the spectral properties. As a result, medium varnish thickness can be determined from spectral measurements. In addition, the composition of a substrate can be estimated through varnish layers up to 40-50 micrometers in median thickness, and the composition of the varnish material can be determined if the substrate material is known. The varnishes studied are composed primarily of clay materials, consistent with previous studies of varnish composition.

Christensen, Philip R.↗

Impact of Surface Enhanced Raman Spectroscopy in Catalysis

Catalysis stands as an indispensable cornerstone of modern society, underpinning the production of over 80% of manufactured goods and driving over 90% of industrial chemical processes. As the demand for more efficient and sustainable processes grows, better catalysts are needed. Understanding the working principles of catalysts is key, and over the last 50 years, surface-enhanced Raman Spectroscopy (SERS) has become essential. Discovered in 1974, SERS has evolved into a mature and powerful analytical tool, transforming the way in which we detect molecules across disciplines. In catalysis, SERS has enabled insights into dynamic surface phenomena, facilitating the monitoring of the catalyst structure, adsorbate interactions, and reaction kinetics at very high spatial and temporal resolutions. This review explores the achievements as well as the future potential of SERS in the field of catalysis and energy conversion, thereby highlighting its role in advancing these critical areas of research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface-Enhanced Raman Spectroscopy Combined with Multivariate Analysis for Fingerprinting Clinically Similar Fibromyalgia and Long COVID Syndromes

Fibromyalgia (FM) is a chronic central sensitivity syndrome characterized by augmented pain processing at diffuse body sites and presents as a multimorbid clinical condition. Long COVID (LC) is a heterogenous clinical syndrome that affects 10–20% of individuals following COVID-19 infection. FM and LC share similarities with regard to the pain and other clinical symptoms experienced, thereby posing a challenge for accurate diagnosis. This research explores the feasibility of using surface-enhanced Raman spectroscopy (SERS) combined with soft independent modelling of class analogies (SIMCAs) to develop classification models differentiating LC and FM. Venous blood samples were collected using two supports, dried bloodspot cards (DBS, n = 48 FM and n = 46 LC) and volumetric absorptive micro-sampling tips (VAMS, n = 39 FM and n = 39 LC). A semi-permeable membrane (10 kDa) was used to extract low molecular fraction (LMF) from the blood samples, and Raman spectra were acquired using SERS with gold nanoparticles (AuNPs). Soft independent modelling of class analogy (SIMCA) models developed with spectral data of blood samples collected in VAMS tips showed superior performance with a validation performance of 100% accuracy, sensitivity, and specificity, achieving an excellent classification accuracy of 0.86 area under the curve (AUC). Amide groups, aromatic and acidic amino acids were responsible for the discrimination patterns among FM and LC syndromes, emphasizing the findings from our previous studies. Overall, our results demonstrate the ability of AuNP SERS to identify unique metabolites that can be potentially used as spectral biomarkers to differentiate FM and LC.

60 APPLIED LIFE SCIENCES↗

Scanning tunneling spectroscopy of surface-oxidized Gallium-stabilized δ -phase plutonium

Here, the first contiguous experimental scanning tunneling spectroscopy (STS) measurements of the electronic structure of a plutonium (Pu) surface are presented and compared to current theoretical results. The experiments took place under UHV conditions, for which Pu is known to retain a native surface oxide. The STS data shows that no band gap is observable at room temperature. Theoretical calculations predict that bulk Pu oxides are semiconductors, but the spectral results for the cleaned Pu surface native oxide under UHV conditions could be better characterized as that of a semimetal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗