Search NASA⌕ Search

SEARCH · Search NASA

Results for “Synchrotron Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Photoelectron spectroscopy of CsK2Sb photocathode at Synchrotron Radiation Facility using vacuum transport system

As accelerators and electron microscopes become more advanced, high-performance photocathodes are required. In particular, Cesium potassium antimonide (CsK 2 Sb) photocathode is of interest because of its low emittance, excitability in visible light, and high quantum efficiency (QE). The challenge is its high susceptibility to environment that lead to low operating vacuum pressure and short lifetime/low extraction charge. To resolve these issues, it is necessary to understand the molecular structure of the cathode and its degradation mechanism. In this study, we transported CsK 2 Sb photocathode to a beamline of synchrotron radiation facility using a vacuum transport system for molecular structure analysis. Specifically, the cathode was deposited in an evaporation system at Nagoya University. We transported it to Aichi Synchrotron Radiation Center (Aichi SR) located 15 km away, and analyzed it in the depth direction by X-ray photoelectron spectroscopy (XPS) at BL7U. Based on the results, we quantitatively evaluated the composition ratios and stoichiometry of the cathode elements (Sb, K, Cs). A Cs ex-cess state of surface was observed at the surface, and it is consistent with previous studies. The intended atomic structure of CsK 2 Sb was formed only at a few nanometres of the surface on the Mo substrate. On the other hand, the CsK 2 Sb cathode structure on the graphene substrate was preserved further in the depth direction.

47 OTHER INSTRUMENTATION↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

Requirements for an in-house synchrotron radiation source at LANL

Synchrotron measurements for diffraction characterization and high resolution tomography require: (1) unable monochromatic X-ray incident energy from 65keV to 100keV. 65keV need is defined by Ta and W absorption edges at 67keV, 100keV need is defined by need to penetrate U/Pu sample thickness of 0.5 mm (2) focused flux density of the monochromatic beam on a beam spot of ~100 µm 2 greater than 10 10 photons per second to allow some slower kinetics experiments such as heating, cooling for CTE measurements (but not quenching, solidification etc. which require <0.1 s resolution) (3) Δλ/λ resolution of 0.3% or better across the energy spectrum. This can be achieved by monochromator as long as flux needs are met in the monochromatic beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dislocation density in fine grain-size spark-plasma sintered aluminum measured using high brightness synchrotron radiation

In this study, three-dimensional orientation mapping of samples of aluminum prepared by spark plasma sintering (SPS) with average grain sizes of 5 μm and 1 μm has been carried out using high-brightness synchrotron radiation, from which the geometrically necessary dislocation (GND) density has been determined. The low average measured GND density values confirm that the SPS process can be used to produce samples containing grains with dislocation density similar to that of fully recrystallized coarse-grained samples. Values of GND density are also compared to those obtained from electron back-scatter diffraction studies on the same material, highlighting the significantly higher angular resolution of the synchrotron data. For the 5 μm grain-size sample the measured GND density can account for a large fraction of the previously observed positive Hall-Petch deviation of this material. For the 1 μm grain-size sample, however, the GND-based strengthening contribution is much smaller than the reported positive Hall-Petch deviation, such that the additional strength may be reliably associated with dislocation source-limited strengthening.

36 MATERIALS SCIENCE↗

Simulations of coherent scattering experiments at storage ring synchrotron radiation sources in the hard x-ray range

Detailed simulations of experiments carried out at modern light sources are directly related to the most efficient and productive use of these facilities for research in multiple branches of science and technology. The “Synchrotron Radiation Workshop” computer code with its Python interface, and Sirepo web-browser-based graphical user interface, currently supports physical optics simulations of coherent X-ray scattering and imaging experiments on user-defined virtual samples. We present examples of simulations of coherent scattering experiments that are typically performed at the Coherent Hard X-ray beamline at Brookhaven National Laboratory’s (BNL) National Synchrotron Light Source II. We also present several comparisons of the simulations with the results of actual coherent X-ray scattering experiments with nano-fabricated test samples produced at BNL’s Center for Functional Nanomaterials.

36 MATERIALS SCIENCE↗

Polarization splitting with cubic crystals evaluated with synchrotron radiation

X-ray polarization-splitting crystals separate incident x rays into two components with perpendicular polarization by Bragg reflections at 45° from paired sets of internal planes. Here, the polarization-splitting properties of a germanium crystal are verified using incompletely polarized synchrotron radiation. Further, cleaner data would have come from a beam with a higher degree of polarization, which is achievable with small changes in the experimental geometry.

47 OTHER INSTRUMENTATION↗

Evaluation of quantitative synchrotron radiation micro-X-ray fluorescence in rice grain

Concentrations of nutrients and contaminants in rice grain affect human health, specifically through the localization and chemical form of elements. Methods to spatially quantify the concentration and speciation of elements are needed to protect human health and characterize elemental homeostasis in plants. Here, an evaluation was carried out using quantitative synchrotron radiation microprobe X-ray fluorescence (SR-µXRF) imaging by comparing average rice grain concentrations of As, Cu, K, Mn, P, S and Zn measured with rice grain concentrations from acid digestion and ICP-MS analysis for 50 grain samples. Better agreement was found between the two methods for high-Z elements. Regression fits between the two methods allowed quantitative concentration maps of the measured elements. These maps revealed that most elements were concentrated in the bran, although S and Zn permeated into the endosperm. Arsenic was highest in the ovular vascular trace (OVT), with concentrations approaching 100 mg kg –1 in the OVT of a grain from a rice plant grown in As-contaminated soil. Quantitative SR-µXRF is a useful approach for comparison across multiple studies but requires careful consideration of sample preparation and beamline characteristics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using Complementary Methods of Synchrotron Radiation Powder Diffraction and Pair Distribution Function to Refine Crystal Structures with High Quality Parameters—A Review

Determination of the atomic-scale structures of certain fine-grained minerals using single-crystal X-ray diffraction (XRD) has been challenging because they commonly occur as submicron and nanocrystals in the geological environment. Synchrotron powder diffraction and scattering techniques are useful complementary methods for studying this type of minerals. In this review, we discussed three example studies investigated by combined methods of synchrotron radiation XRD and pair distribution function (PDF) techniques: (1) low-temperature cristobalite; (2) kaolinite; and (3) vernadite. Powder XRD is useful to determine the average structure including unit-cell parameters, fractional atomic coordinates, occupancies and isotropic atomic displacement parameters. X-ray/Neutron PDF methods are sensitive to study the local structure with anisotropic atomic displacement parameters (ADP). The results and case studies suggest that the crystal structure and high-quality ADP values can be obtained using the combined methods. The method can be useful to characterize crystals and minerals that are not suitable for single-crystal XRD.

58 GEOSCIENCES↗

Single electron in a storage ring: a probe into the fundamental properties of synchrotron radiation and a powerful diagnostic tool

An experimental study of undulator radiation generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. Photons were detected with a single-photon avalanche diode (SPAD) at an average rate of 20 kHz, corresponding to one detection every few hundred revolutions. Events were continuously recorded by a picosecond event timer for as long as 5 minutes at a time. The collected data were used to directly test the predictions of classical Poisson photostatistics. The study was motivated in part by a previous observation of sub-Poissonian statistics in a similar experiment with synchrotron radiation. In addition, we show that the time series of recorded events can be used to study the synchrotron motion of a single electron, yielding dynamical parameters such as the phase jitter of the radiofrequency cavity and the dependence of the synchrotron period on amplitude. Research plans for further experiments are also discussed.

47 OTHER INSTRUMENTATION↗

Intermolecular correlations of liquid and glassy CS 2 studied by synchrotron radiation x-ray diffraction

How is the orientation of molecular liquids ordered on cooling? What are the basic structures of molecular glasses, e.g., close to the crystalline structure or some special structures such as icosahedral cluster? These are long-standing questions in liquid and glass physics. Here, we have constructed a novel cryostat to prepare simple molecular glasses by vapor deposition and performed in situ synchrotron radiation x-ray diffraction experiments. The glassy state of a simple molecule CS 2 , which cannot be vitrified by normal liquid quenching, was successfully prepared with this instrument, and its diffraction data were collected in a wide Q-range of 0.16–25.7 Å -1 with a high-energy diffractometer at BL04B2, SPring-8. The diffraction data of liquid CS 2 were also recorded in a wide temperature range of 160–300 K. These diffraction data were analyzed with molecular dynamics simulations and reverse Monte Carlo modelings to investigate orientational correlation. From the obtained 3D structure models, the orientational correlation between neighboring CS 2 molecules was investigated quantitatively as a function of temperature. At room temperature, the parallel and T-shaped arrangements are preferred for the nearest neighbor correlation. On cooling, these arrangements are developed gradually, and its rate became prominent below the melting temperature (162 K). In the glassy state, the slipped-parallel arrangement is dominant as well as the T-shaped arrangement. Both arrangements appear in the CS 2 crystal, indicating that the structure of glassy CS 2 is close to that of crystalline CS 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced storage ring lattice options based on hybrid six-bend achromat for Stanford Synchrotron Radiation Lightsource upgrade

Three storage ring lattices have been designed as options for a future upgrade of the Stanford synchrotron radiation lightsource (SSRL). The three options differ in circumference and targeted future site, with one to be built in the tunnel of the present SPEAR3 ring, one as a green field ring on the SLAC campus, and the third in the tunnel of the decommissioned PEP-II ring. The lattices are based on the newly proposed hybrid 6-bend achromat (H6BA) lattice cells, which is ideal for pushing the photon beam brightness while achieving excellent nonlinear dynamics performance. The transparent matching conditions are enforced to minimize the negative impact of the loss of periodicity due to insertion of various long straight sections. Numerical optimization is performed to further improve the nonlinear dynamics. Finally, in addition to reaching very low emittances, the lattices can accommodate traditional off-axis injection and achieve beam lifetimes similar to or exceeding that of typical third generation rings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy particle production from proton synchrotron radiation in strong magnetic fields in relativistic quantum field theory

We investigate photon, pion, and 𝜌-meson production from proton synchrotron radiation in the presence of strong magnetic fields. The proton decay widths and the luminosities of the emitted particles are calculated within a relativistic quantum framework that incorporates Landau quantization. A scaling rule is derived for the transition probability between different Landau levels. This allows an evaluation of transitions for extremely high Landau numbers exceeding 10 15 . Furthermore, we calculate the momentum distribution of the emitted particles by properly including the proton recoil effect associated with particle emission. The results differ significantly from conventional semiclassical approaches.

Cosmic ray sources↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

The crystal structures of Fe-bearing MgCO 3 sp 2 - and sp 3 -carbonates at 98 GPa from single-crystal X-ray diffraction using synchrotron radiation

The crystal structure of MgCO 3 -II has long been discussed in the literature where DFT-based model calculations predict a pressure-induced transition of the carbon atom from the sp 2 to the sp 3 type of bonding. We have now determined the crystal structure of iron-bearing MgCO 3 -II based on single-crystal X-ray diffraction measurements using synchrotron radiation. We laser-heated a synthetic (Mg 0.85 Fe 0.15 )CO 3 single crystal at 2500 K and 98 GPa and observed the formation of a monoclinic phase with composition (Mg 2.53 Fe 0.47 )C 3 O 9 in the space group C 2/ m that contains tetrahedrally coordinated carbon, where CO 4 4- tetrahedra are linked by corner-sharing oxygen atoms to form three-membered C 3 O 9 6- ring anions. The crystal structure of (Mg 0.85 Fe 0.15 )CO 3 (magnesium iron carbonate) at 98 GPa and 300 K is reported here as well. In comparison with previous structure-prediction calculations and powder X-ray diffraction data, our structural data provide reliable information from experiments regarding atomic positions, bond lengths, and bond angles.

Chariton, Stella (ORCID:0000000155220498)↗

Simulation of X-ray Hartmann wavefront sensing with the Synchrotron Radiation Workshop

X-ray wavefront measurement is an important beam diagnostic tool, especially for the diffraction-limited X-ray beam. These in situ diagnostics give a better understanding of beam imperfections, and they enable feedback for possible corrections and/or optical alignment improvements. Hartmann wavefront sensing is one of the promising techniques to perform in situ X-ray wavefront measurements. In this work, a simulation tool of the X-ray Hartmann Wavefront Sensor (HWS) is developed under the Synchrotron Radiation Workshop (SRW) framework. Using this new simulation capability, one can take advantage of the full SRW package to simulate Hartmann wavefront sensing with the beam traveling from the X-ray source to the sample through different X-ray optical components. This SRW HWS simulation tool can help to optimize the wavefront sensor parameters for a specific X-ray energy range. It can also simulate an in situ wavefront measurement experiment with a particular beamline optical layout and predict the expected results of the wavefront measurement under different beamline configurations.

36 MATERIALS SCIENCE↗