Search NASA⌕ Search

SEARCH · Search NASA

Results for “System packages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Bringing Fault Detection and Diagnostics (FDD) Tools into the Mainstream: Retro Commissioning and Continuous Commissioning of HVAC and Refrigeration Systems

HVAC systems in the commercial building sector consume about 3.4 quads of energy annually. Of all the HVAC systems, packaged rooftop air–conditioning units (RTUs) provide cooling and heating for over 60 percent of the commercial building floorspace (about 90 billion ft2) in the U.S. and they are a significant source of energy consumption and peak demand. All HVAC systems suffer from faults that impact thermal comfort and increase energy consumption. There are several commercially available Automated Fault Detection and Diagnostic (AFDD) tools on the market that can detect and diagnose faults, and if those faults are corrected, can save significant national energy. However, there are multiple market barriers for these tools including lack of independent verification of their performance in the field in terms of their technical capabilities, ease of use and installation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Ammonia Carrier Materials for Next Generation Ammonia Dosing System - CRADA 334 (Abstract)

Lean-burn gasoline and diesel engines can offer substantially higher fuel efficiency, good driving performance, and reduced carbon dioxide emission compared to stoichiometric gasoline engines. Various catalyst technologies have been developed to remove the pollutants from these engines. For example, a three-way catalyst (TWC) is used to remove hydrocarbons (HC), carbon monoxide (CO), and nitrogen oxides (NOx) from gasoline engines during the stoichiometric conditions. During the lean-burn conditions, a TWC or a diesel oxidation catalyst (DOC) is used to control HC and CO emissions. NOx is removed by either lean NOx trap catalyst (LNT) that can store NOx under lean conditions and reduce NOx under rich conditions, or selective catalytic reduction catalyst (SCR) that can selectively remove NOx with a reducing agent. Among the NOx reduction catalyst technologies, SCR offers a number of advantages, including excellent NOx reduction efficiency over a wide range of temperatures and overall lower system cost. In fact, the SCR technology using ammonia (NH3) as reductant has been proven effective and used commercially for the removal of NOx emissions from stationary sources since the 1970s. Currently, SCR is being used to meet the NOx emission standards for diesel engines in Europe and North America, and also being considered for meeting the future NOx emission standards for lean-burn gasoline engines. Because of the challenges associated with storage, handling and transportation of ammonia on a vehicle, aqueous urea solution (e.g., Diesel Exhaust Fluid, AdBlue) has been developed as ammonia storage compound for mobile applications. When the aqueous urea solution is sprayed into exhaust gas stream, urea is decomposed to release ammonia, which then reduces NOx over the downstream SCR catalyst. Although aqueous urea solution technology has enabled automakers and engine manufacturers to meet the current NOx emission standards, this process of releasing ammonia requires a hot exhaust gas and sufficient mixing, creating challenges for low temperature NOx emission control and aftertreatment system packaging. For these reasons, alternative technologies have been developed as ammonia sources (e.g., solid urea, ammonium carbamate, metal ammine chloride) during the past few years. These technologies promise more convenient handling and distribution of ammonia sources, and help maximize the low-temperature performance of SCR catalysts and reduce the overall system volume and weight. However, none of these alternative technologies can be successfully implemented without the industry consensus. Therefore, the USCAR SCR work group, which is comprised of representatives from GM, Ford, and Chrysler, has decided to investigate the potential alternative ammonia carriers, define common standard vehicle interfaces, and address personal and environmental safety concerns with part suppliers and chemical companies. Under this CRADA Project, USCAR and Battelle will investigate alternative ammonia carrier materials that are currently under development. Based on the data and information derived under the CRADA project, the USCAR SCR work group plans to build the consensus and make recommendations for the industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Ammonia Carrier Materials for Next Generation Ammonia Dosing System - CRADA 334 (Abstract)

Lean-burn gasoline and diesel engines can offer substantially higher fuel efficiency, good driving performance, and reduced carbon dioxide emission compared to stoichiometric gasoline engines. Various catalyst technologies have been developed to remove the pollutants from these engines. For example, a three-way catalyst (TWC) is used to remove hydrocarbons (HC), carbon monoxide (CO), and nitrogen oxides (NOx) from gasoline engines during the stoichiometric conditions. During the lean-burn conditions, a TWC or a diesel oxidation catalyst (DOC) is used to control HC and CO emissions. NOx is removed by either lean NOx trap catalyst (LNT) that can store NOx under lean conditions and reduce NOx under rich conditions, or selective catalytic reduction catalyst (SCR) that can selectively remove NOx with a reducing agent. Among the NOx reduction catalyst technologies, SCR offers a number of advantages, including excellent NOx reduction efficiency over a wide range of temperatures and overall lower system cost. In fact, the SCR technology using ammonia (NH3) as reductant has been proven effective and used commercially for the removal of NOx emissions from stationary sources since the 1970s. Currently, SCR is being used to meet the NOx emission standards for diesel engines in Europe and North America, and also being considered for meeting the future NOx emission standards for lean-burn gasoline engines. Because of the challenges associated with storage, handling and transportation of ammonia on a vehicle, aqueous urea solution (e.g., Diesel Exhaust Fluid, AdBlue) has been developed as ammonia storage compound for mobile applications. When the aqueous urea solution is sprayed into exhaust gas stream, urea is decomposed to release ammonia, which then reduces NOx over the downstream SCR catalyst. Although aqueous urea solution technology has enabled automakers and engine manufacturers to meet the current NOx emission standards, this process of releasing ammonia requires a hot exhaust gas and sufficient mixing, creating challenges for low temperature NOx emission control and aftertreatment system packaging. For these reasons, alternative technologies have been developed as ammonia sources (e.g., solid urea, ammonium carbamate, metal ammine chloride) during the past few years. These technologies promise more convenient handling and distribution of ammonia sources, and help maximize the low-temperature performance of SCR catalysts and reduce the overall system volume and weight. However, none of these alternative technologies can be successfully implemented without the industry consensus. Therefore, the USCAR SCR work group, which is comprised of representatives from GM, Ford, and Chrysler, has decided to investigate the potential alternative ammonia carriers, define common standard vehicle interfaces, and address personal and environmental safety concerns with part suppliers and chemical companies. Under this CRADA Project, USCAR and Battelle will investigate alternative ammonia carrier materials that are currently under development. Based on the data and information derived under the CRADA project, the USCAR SCR work group plans to build the consensus and make recommendations for the industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scientific Core Library Stack (SCLS) v2026

SCLS (Scientific Core Library Stack) is an opinionated build and packaging system for scientific computing libraries developed at Lawrence Berkeley National Laboratory. It produces a coherent, reproducible stack of numerical libraries — including BLAS/LAPACK, MPI, sparse direct and iterative solvers, graph partitioners, and parallel I/O libraries (e.g., PETSc, SLEPc, HDF5, NetCDF, MUMPS, OpenBLAS) — that work together without manual repair by downstream scientific software. From a single recipe-and-flavor model, SCLS produces native RPM packages for RHEL-family Linux, DEB packages for Debian/Ubuntu, direct Unix-style prefix installs for HPC and locked-down environments, and native macOS builds. Multiple build "flavors" (e.g., GCC+OpenBLAS, GCC+MKL, Intel+MKL, debug) coexist in distinct prefixes on the same host. Compared to general-purpose meta-build frameworks, SCLS is deliberately curated rather than infinitely configurable. It enforces deterministic, audit-friendly behavior: explicit build dependencies, no silent feature autodetection, a clear open-source license policy, and rpath-based runtime linkage so installs integrate cleanly with standard package-manager workflows.

Messe, Christian [Lawrence Berkeley National Labor↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

Hydrogen Transport in a Model 9979 Shipping Package with Inner Convenience Cans

Radiolytic hydrogen production and accumulation inside containment packages is a concern at any facility responsible for their packaging, storage, transportation, and/or disposal. When hydrogen gas accumulates to concentrations above the Lower Flammability Limit (LFL) which is 4% or 40,000 ppm in air, the possibility of a deflagration or explosion increases. This concern persists over the course of the package lifetime which is unlimited when disposed of by burial or in permanent repositories. Here, we report on a numerical model used to predict the concentration of hydrogen within each layer of a Model 9979 package containing a convenience can assembly. Simulations show the hydrogen concentration to always be highest in the inner convenience can containing the radioactive source. When the radioactive source is within the Los Alamos National Laboratory (LANL) Packaging Limits, the hydrogen concentration is shown to remain well below the LFL at all times including packaging, storage, transportation, and disposal. A hydrogen transport model is presented for a Model 9979 package system containing a nested arrangement of convenience cans, which are tin oxide coated steel cans of various sizes with a slip-lid assembly. The inner convenience can contains the radioactive source material along with an unknown quantity of incidental water acquired from humid air or processing. While visible organic materials such as paper and plastics were purposely excluded from the inner can, it is not possible to claim the wastes are entirely organic free. The inner convenience can is tape sealed and placed into a plastic bag which is horsetail closed (i.e., twisted and taped). The bagged can is placed into an outer convenience can that is also tape sealed. The can assembly is then placed into the 30 gallon drum and subsequently placed inside the 55 gallon drum in the 9979 package. Here we assume hydrogen gas is produced in the inner convenience can from alpha radiolysis of water at a rate dependent on the quantity of uranium isotopes and water present. The hydrogen transport model was used to calculate hydrogen accumulations within the package’s five layers at different times and conditions. These simulations serve two purposes; (i) to build confidence in the model by comparing predicted values to measured values, and (ii) to check the steady state hydrogen concentrations that are approached at long times in the package’s lifetime. Model simulations were compared to gas samples taken from the 30 gallon drum after storage at LANL’s Chemistry and Metallurgy Research (CMR) building for around 500 days. Hydrogen concentration calculations over much longer periods (i.e., more than 270 years) included extreme storage durations, transportation at extreme cold temperatures, and disposal of packages assuming different average temperatures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stereochemically‐Controlled Fluorinated Copolymers for Selectively Permeable Barrier Applications

Selective oxygen permeability coupled with low water vapor transmission is essential for biomedical and packaging applications requiring controlled oxygen flux under humid conditions. However, most high‐performance barrier polymers depend on perfluoroalkyl substances (PFAS), whose persistence and regulatory restrictions limit their long‐term applicability. We designed a series of stereocontrolled thiol‐yne‐based polyesters, including both fluorinated and non‐fluorinated variants, for selective oxygen permeability with considerable water barrier performance. Tailoring polymer crystallinity and morphology tuned both oxygen transport and mechanical properties. Fluorinated polymers demonstrated enhanced hydrophobicity and water resistance while maintaining oxygen diffusivity within a range relevant to oxygen‐sensing applications. Structure–property relationships were elucidated through small‐ and wide‐angle X‐ray scattering, revealing semi‐crystalline domains influenced by fluorine content and dithiol chain length. Barrier performance was rigorously evaluated via water vapor transmission rate and dynamic vapor sorption, showing reduced water uptake with increasing dithiol monomer length and crystallinity. In conclusion, this work introduces a PFAS‐free alternative to conventional barrier materials and establishes a tunable materials platform with potential relevance for biomedical devices and packaging systems requiring controlled oxygen permeability.

36 MATERIALS SCIENCE↗

Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

Rooftop units (RTUs) and other packaged systems are very common in commercial buildings in the U.S., and they often have minimal controls and poor performance. Automated fault detection and diagnostics (AFDD) is a powerful tool that can continuously monitor operating equipment, detect abnormal performance, diagnose problems, and report findings to building operators. AFDD technologies for RTUs have been under development for many years and have recently begun to enter the market in a significant way. There are several AFDD systems available for RTUs that feature a wide range of designs, capabilities, and reporting. Unfortunately, there is little consistency among the AFDD applications and little understanding of the performance and value of these systems. This study presents analysis of AFDD data provided by four companies from over 28,000 RTUs, five building types, and multiple climate zones. The objectives of this investigation were to gain a better understanding of how RTU AFDD systems operate, the types and frequencies of faults identified, and how building operators interact with these systems. The monitoring of a variety of RTUs provides insights into the AFDD monitoring inputs, faults, and diagnostics from which these tools are capable of informing building owners about the status of their HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

Rooftop units (RTUs) and other packaged systems are very common in commercial buildings in the U.S., and they often have minimal controls and poor performance. Automated fault detection and diagnostics (AFDD) is a powerful tool that can continuously monitor operating equipment, detect abnormal performance, diagnose problems, and report findings to building operators. AFDD technologies for RTUs have been under development for many years and have recently begun to enter the market in a significant way. There are several AFDD systems available for RTUs that feature a wide range of designs, capabilities, and reporting. Unfortunately, there is little consistency among the AFDD applications and little understanding of the performance and value of these systems. This study presents analysis of AFDD data provided by four companies from over 28,000 RTUs, five building types, and multiple climate zones. The objectives of this investigation were to gain a better understanding of how RTU AFDD systems operate, the types and frequencies of faults identified, and how building operators interact with these systems. The monitoring of a variety of RTUs provides insights into the AFDD monitoring inputs, faults, and diagnostics from which these tools are capable of informing building owners about the status of their HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Strain in the Vadose Zone During Sinusoidal-Rate Well Tests to Characterize an Aquifer

Well tests with sinusoidal variation in pumping rate are appealing because of the ability to filter competing signals and they also can be set up with no net removal of water, which is an advantage at contaminated sites. Current methods of interpreting sinusoidal-rate well tests analyze the phase lag and amplitude of pressure signals in the aquifer. This approach is restricted by the availability of monitoring wells. An alternative approach could be to measure the stain in the vadose zone instead of pressure in the aquifer. The goal of this research is to evaluate the feasibility of using signals from in-situ sensors in the vadose zone to characterize sinusoidal-rate well tests. Well tests with a variety of periods and amplitudes were performed using a well completed in an unconfined saprolite aquifer with a water table at 9m depth at our test site near Clemson, South Carolina. Vertical strain was measured every meter between 1 to 7 m using a distributed optical fiber sensing technique called coherence length gated microwave photonics interferometry (CMPI). A novel packaging system was designed to couple the optical fiber to the saprolite. The results show that strain measured in the vadose zone during sinusoidal-rate pumping varies periodically with amplitudes from 0.1 to 3 microstrain, depending on the amplitude of the sinusoidal pumping rate. Hydraulic heads at similar radial distances were also periodic with changing amplitudes ranging up to ±0.2 meters. The strain in the vadose zone responds to pressure in the underlying aquifer—the strain is tensile when the pressure is falling, and compressive when the pressure is rising. The phase lag between the pumping rate and the strain was 3 min with a pumping period of 15 minutes, and this gives a hydraulic diffusivity of 0.06 m2/s. This is the same diffusivity obtained by analyzing a constant rate pumping test, and it is slightly larger than the diffusivity (0.044 m2/s) obtained by analyzing the phase lag of the pressure in a nearby monitoring well. Strain measurements in the vadose zone could be made with much less cost and effort than installing a deep monitoring well. These results suggest that strain measurements in the vadose zone could be used to supplement monitoring wells, thereby increasing the resolution, and reducing costs of analyzing well tests.

well test, sinusoidal, periodic pumping, strain↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Device- and System-Level Thermal Packaging for Electric-Drive Technologies (Final Technical Report)

Final Technical ReportThis project aimed to research, develop, and test electric traction drive system technology for use in vehicle applications that are capable of meeting the targets set by the Department of Energy Vehicle Technologies Office. The project is categorized into three major thrusts: Bonding interfaces for packaging, thermal management of electric vehicle (EV) power inverters, and electric motor thermal management. Device- and System-Level Thermal Packaging for Electric-Drive Technologies project aimed to develop, analyze, and validate transformative approaches in thermal management and packaging for power electronics and electric motor systems, with the ultimate goal of enhancing power density, efficiency, and reliability in electrified transportation platforms.

33 ADVANCED PROPULSION SYSTEMS↗

A python package for analyzing Resilience of Complex Systems (pyRoCS) v.0.0

SAND2024-01040O PyRoCS software synthesizes mathematical equations from several domains—including information theory, ecology, and engineering sciences—to support resilience analysis for complex systems. Resilience is the ability of the complex system being analyzed to withstand, operate through, and recover from a disruption. The complex system can be a physical system such as an electric grid, an organization such as a company, or even a subfunction of an organization. Existing mathematical equations for resilience analysis are found within multiple domains including information theory, biological sciences, and complex systems. This package synthesizes and refactors equations from these various domains to make them more generalizable for application across different types of complex systems relevant for resilience analysis. Users will be able to apply these equations to characterize different components of complex systems based on available data. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Verzi, Stephen↗

Smart Monitoring and Diagnostic System (SMDS) for Packaged Air Conditioners and Heat Pumps for Small/Medium Commercial Buildings: Preparation for Commercialization: CRADA 478 [Abstract only]

This project will enable Pacific Northwest National Laboratory (PNNL) and industry partner, mCloud Technologies, to work collaboratively to ready the Smart Monitoring and Diagnostic System (SMDS) for commercial deployment and validate its performance under real-world conditions at field sites. This project will specifically focus on 1) implementing the SMDS algorithms in a scalable cloud-based software architecture, 2) designing new, innovative, complimentary commercial services based on the SMDS, 3) enhancing the SMDS energy and cost impact algorithms to reduce uncertainty in estimates, 4) determining the lower limits on SMDS performance degradation detection, 5) validating algorithm performance and default values of adjustable thresholds with existing data from controlled physical testing and from customer packaged air conditioners and heat pumps (commonly referred to as rooftop units or RTUs), 6) field testing to validate the system on multiple customer buildings in diverse environments, and 7) expanding field deployment to a larger set of mCloud’s customer buildings. Project results by validating, enhancing, and quantifying the performance of the SMDS will position mCloud, and potential future licensees, to implement the SMDS in commercial offerings that encourage and enable use of condition-based and predictive maintenance, leading to significant reductions in energy use and greenhouse gas emissions associated with space conditioning by RTUs. Furthermore, these enhancements will increase the value of the SMDS for users and increase the potential market for its use and impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and dispatch optimization of packaged ice storage systems within a connected community

The traditional implementation of cool thermal energy storage (CTES) must be reimagined within the context of a dynamic grid and smart buildings operating as connected communities. As most buildings do not operate central chillers or connect to district cooling loops, this necessitates a broader use of packaged CTES. Our objective is to begin answering the question of how such packaged CTES should be implemented within a connected community. We do so by presenting a simulation–optimization workflow employing building energy modeling software and a mixed-integer linear program to design and dispatch a packaged CTES technology to achieve minimum total annual cost. We demonstrate this methodology on a seven-building case study using current utility rates and find that total annual cooling energy costs can be reduced by 17.8% compared to baseline, after accounting for the cost of storage. We perform three parametric sensitivity studies to evaluate modeling assumptions and obtain the prioritization of storage procurement as a function of annualized life-cycle cost of storage. We find that a community optimization approach provides significantly different results than individual building optimizations and provides greater savings compared to baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Silicon Carbide Inverter for Off-Road Heavy-Duty Applications: The Importance of Thermal and Thermomechanical Design in Power Electronics Packaging

Electrification of drivetrain systems is now seen as a major opportunity by the transportation industry across the globe to reduce the greenhouse gas emissions and revolutionize the travel patterns of millions of people. The cumulative number of plug-in hybrid and battery electric vehicles (EVs) sold in the United States has now surpassed 2 million in 2021, according to the International Energy Agency. The introduction of EVs in different classes of passenger vehicles and the continued drop in prices spurred by government incentives have attracted the attention of consumers despite certain barriers, such as higher initial cost and range anxiety. In the United States, the EV market share is now growing at an exponential pace, with the domestic automakers allocating a lion's share of new and future car sales to EVs. Additionally, different market studies project decreasing cost and rising sales of medium- and heavy-duty electric trucks. Although electrification initiatives are strongly pursued in the on-road passenger vehicle market, off-highway sectors, such as construction, mining, and agriculture, are also gradually implementing electric drivetrain technologies in their machineries. As EVs grow in popularity on a global scale, innovative drivetrain technologies must meet the increasing energy demand by significantly increasing system efficiency.

ADVANCED PROPULSION SYSTEMS↗

Packaged Combined Heat and Power Technology Overview and Market Profile

Combined heat and power (CHP), sometimes referred to as cogeneration, is an efficient and clean approach to generating electric power and useful thermal energy onsite from a single fuel source, offering reliable and affordable energy services to businesses and institutions. Furthermore, CHP provides a cost effective opportunity to improve the environmental footprint and resilience of industrial and commercial facilities across the United States. CHP equipment can be custom-engineered or installed as a predesigned and assembled package. A packaged CHP system is a standardized, pre-engineered system that includes all equipment, piping, wiring, and ancillary components to deliver electricity and thermal energy to a host facility with minimal onsite engineering and design time. Packaged CHP systems can be shipped as single or multiple modules with standard interconnections (e.g., fuel; electrical; thermal—hot water, steam, and/or chilled water), which simplifies installation and reduces the costs associated with the project. Most containerized or single packaged CHP system offerings range from 10 kW to 3 MW in capacity. Packaged CHP systems are extending the operating, efficiency, and emissions benefits of CHP to nontraditional markets in commercial, institutional, multifamily, light manufacturing, government, and military applications. These markets tend to be served by smaller systems (less than 5 MW) that are conducive to pre-engineered packaging and/or modularization. Many of these sectors have limited CHP experience and technical resources to adequately evaluate, install, and maintain onsite CHP systems. The introduction of packaged CHP offerings from experienced CHP Packagers and Solution Providers has accelerated CHP adoption, lowered energy costs, reduced emissions, and strengthened energy resilience in these sectors. In 2019, the US Department of Energy (DOE) launched the Packaged CHP eCatalog to promote increased acceptance of efficient, cost-effective CHP in these applications. The Packaged CHP eCatalog is a web-based, searchable platform that hosts DOE-recognized packaged CHP systems with features designed to reduce economic and performance risks for designers, developers, owners, and facility operators interested in installing CHP. DOE established the Packaged CHP Accelerator at the same time to help launch and publicize the eCatalog, and to validate project performance, cost, and installation time of CHP packages across a variety of applications. Accelerator efforts documented installed cost reductions and installation time reductions of more than 20% for packaged CHP systems over 100 kW compared with custom-engineered systems. The Packaged CHP Accelerator and eCatalog established a peer-to-peer network connecting public and private sector partners including utilities, state energy offices, and energy efficiency program administrators interested in promoting cost-effective, efficient CHP systems, Packagers, and Solution Providers. Feedback from these partners, along with input from DOE’s CHP Technical Assistance Partnerships (CHP TAPs), was critical in understanding the current market for packaged CHP technologies, stimulating investment in these technologies, and guiding future directions for packaged CHP systems and their applications. This report provides background on packaged CHP systems, an overview of their benefits, a profile of current packaged CHP installations, and a summary of future market trends; this report is intended for facility owners, project developers, engineers, policymakers, and other stakeholders looking to increase the adoption of efficient, flexible, and resilient packaged CHP systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗