Search NASA⌕ Search

SEARCH · Search NASA

Results for “TDLAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

A tunable diode laser system for aircraft measurements of trace gases

The advantages of tunable-diode-laser absorption spectrometry (TDLAS) for measuring trace atmospheric gases are universality, positive identification, good sensitivity, and rapid response time. A TDLAS system is described which is capable of making measurements aboard an aircraft. The instrument was employed during the Chemical Instrumentation Test and Evaluation (CITE) 2 program to measure NO2 on 11 flights and HNO3 on five flights. Detection limits were determined to be 25 parts per trillion by volume (pptv) for NO2 and 75 pptv for HNO3 with response times of 3 min. This was sufficient to permit measurements of NO2 in the free troposphere and HNO3 in the continental boundary layer a significant fraction of the time.

Schiff, H. I.↗

The Role of Convection in Redistributing Formaldehyde to the Upper Troposphere Over North America and the North Atlantic during the Summer 2004 INTEX Campaign

Measurements of CH2O from a tunable diode laser absorption spectrometer (TDLAS) were acquired onboard the NASA DC-8 during the summer 2004 INTEX-NA (Intercontinental Chemical Transport Experiment - North America) campaign to test our understanding of convection and production mechanisms in the upper troposphere (UT, 6-12-km) over continental North America and the North Atlantic Ocean. Point-by-point comparisons with box model calculations, when MHP (CH3OOH) measurements were available for model constraint, resulted in a median CH2O measurement/model ratio of 0.91 in the UT. Multiple tracers were used to arrive at a set of UT CH2O background and perturbed air mass periods, and 46% of the TDLAS measurements fell within the latter category. At least 66% to 73% of these elevated UT observations were caused by enhanced production from CH2O precursors rather than direct transport of CH2O from the boundary layer. This distinction is important, since the effects from the former can last for over a week or more compared to one day or less in the case of convective transport of CH2O itself. In general, production of CH2O from CH4 was found to be the dominant source term, even in perturbed air masses. This was followed by production from MHP, methanol, PAN type compounds, and ketones, in descending order of their contribution. In the presence of elevated NO from lightning and potentially from the stratosphere, there was a definite trend in the CH2O discrepancy, which for the highest NO mixing ratios produced a median CH2O measurement/model ratio of 3.9 in the 10-12-km range. Discrepancies in CH2O and HO2 in the UT with NO were highly correlated and this provided further information as to the possible mechanism(s) responsible. These discrepancies with NO are consistent with additional production sources of both gases involving CH3O2 + NO reactions, most likely caused by unmeasured hydrocarbons.

Fried, Alan↗

Development of a Portable Oxygen Monitoring System for Operations in the International Space Station Airlock

NASA is currently engaged in an activity to facilitate effective operations on the International Space Station (ISS) after the Space Shuttle retires. Currently, the Space Shuttle delivers crew and cargo to and from ISS. The Space Shuttle provides the only large scale method of hardware return from ISS to the ground. Hardware that needs to be periodically repaired, refurbished, or recalibrated must come back from ISS on the Shuttle. One example of NASA flight hardware that is used on ISS and refurbished on the ground is the Compound Specific Analyzer for Oxygen (CSA-O2). The CSA-O2 is an electrochemical sensor that is used on orbit for about 12 months (depending on Shuttle launch schedules), then returned to the ground for sensor replacement. The shuttle is scheduled to retire in 2010, and the ISS is scheduled to operate until 2016. NASA needs a hand held sensor that measures oxygen in the ISS environment and has a 5-10 year service life. After conducting a survey of oxygen sensor systems, NASA selected a Tunable Diode Laser Absorption Spectrometer (TDLAS) as the method of measurement that best addresses the needs for ISS. These systems are compact, meet ISS accuracy requirements, and because they use spectroscopic techniques, the sensors are not consumed or altered after making a measurement. TDLAS systems have service life ratings of 5-10 years, based on the lifetime of the laser. NASA is engaged in modifying a commercially available sensor, the Vaisala OMT 355, for the ISS application. The Vaisala OMT 355 requires three significant modifications to meet ISS needs. The commercial sensor uses a wall mount power supply, and the ISS sensor needs to use a rechargeable battery as its source of power. The commercial sensor has a pressure correction setpoint: the sensor can be adjusted to operate at reduced pressure conditions, but the sensor does not self correct dynamically and automatically. The ISS sensor needs to operate in the airlock, and make accurate measurements in an environment that can change from 14.7 psia to 10.2 psia in 15 minutes. The commercial sensor needs to be repackaged into a configuration that is more compact, and better suited for ISS airlock operations. NASA has recently completed a prototype of the reconfigured system. The unit has been repackaged in a way that the optical path of the spectrometer is unchanged, but the electronics has been integrated into a case measuring 10.7 X 7.2 X 3.0 inches. Two flight qualified rechargeable batteries have been integrated into system. The batteries can power the sensor for 10 hours on a single charge. A pressure sensor has been added to the system. The modified unit automatically compensates for changes in pressure, and meets 0.2% accuracy requirements for oxygen measurements in an environment with 18 to 32% oxygen across a pressure range of 10.0 to 15.0 psia.

Graf, John↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

MARS 2020 Backshell Radiative Heating Measurement and Shock Tube Verification

In February 2021, the Perseverance rover was brought to the surface of Mars by the Mars 2020 mission. A feature of the Mars 2020 capsule was instrumentation to measure its entry, descent and landing (EDL) with the so-called Mars EDL Instrumentation 2 (MEDLI2) [1]. The MEDLI2 introduced, among other things, backshell instrumentation, including a broadband radiometer. The radiometer was mounted on the leeside of the vehicle next to thermocouple plugs and a heat flux gauge. The data returned by the leeside MEDLI2 heat flux gauge is largely analogous to that measured by the COMARS gauge flown on the ExoMars Schiaparelli [2] entry in that it is measuring heat flux in an area that is entirely dominated by radiative heating. The COMARS measurement provided excellent validation of backshell radiative heating models for Mars entry, albeit at a limited number of points [3]. The MEDLI2 heat flux gauge measurement effectively confirmed the quality of the prediction, extended over the full trajectory, as will be presented in this paper. The MEDLI2 radiometer,however, was blocked by ablation products and suffered a loss of half of its signal. The second backshell heat flux gauge installed on the windside of the vehicle was also well predicted, although the heating had both radiative and convective contributions. It was desired to reproduce the conditions of the Mars 2020 entry via ground testing in the Electric Arc Shock Tube (EAST) at NASA Ames. Tests to verify stagnation line heating were previously reported in EAST, confirming the presence of shock layer radiation as the major discrepancy in heatshield temperature modelling [4]. Therefore, tests for stagnation line heating were not repeated. Instead, the shock tube informed bias method [5, 6] was used to identify test conditions that may produce similarity to streamlines that pass around the backside of the vehicle and are responsible for the radiation observed at the two heat flux gauge locations. This method was used to identify a range of velocities and densities in the shock tube that are relevant for confirming the radiative environment encountered. This paper reports the results obtained in the 10 cm diameter EAST shock tube, corresponding to later trajectory points at ambient pressures of 1.1-2.0 Torr and velocities from 1.2-3.5 km/s. The test series employed two primary diagnostics: emission spectroscopy and tunable diode laser absorption spectroscopy (TDLAS). The emission spectroscopy performed broadband measurements of the radiative emission of the 4.3 and 2.7 m bands of CO2 at flight similar conditions, obtaining both spectral and spatial data corresponding to the relaxation behind the shock front. The TDLAS measured the absorption of several lines of CO and CO2 and obtains species number densities and temperatures as a function of time behind the shock front. This paper will review highlights of this test series and analyses of the emission and absorption data. While the datasets generally show good agreement with predictions, a few discrepancies and items for additional investigation are identified and will be discussed

Brett A Cruden↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin C Tibere-Inglesse↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin Tibère-Inglesse↗

Absorption spectroscopy based high-speed oxygen concentration measurements at elevated gas temperatures

A sensor built upon tunable diode laser absorption spectroscopy (TDLAS) has been developed for concentration measurements in high-temperature (up to 800 K) gas streams; while the sensor measures gas oxygen and water concentration, temperature and pressure, this work focuses on the challenges and solutions to transient oxygen measurement. A 760-nm diode laser was used to probe a pair of oxygen absorption transitions, and a Herriott cell based multi-pass arrangement was utilized to compensate for the extremely weak oxygen absorption as well as the high gas temperature. This multi-pass arrangement provides a 4297.4-mm absorption path length across a 76.2-mm diameter duct, and an O 2 detection limit ([O 2 ] where SNR=1) of ca. 0.1%. Laboratory validation of the HITRAN spectral parameters of the chosen absorption transitions was performed over a range of high temperatures and oxygen concentrations relevant to engine-exhaust applications. The insensitivity of the Herriott cell arrangement to vibrations and spatial temperature gradients was demonstrated. Conclusions from applications to single- and multi-cylinder engine exhaust are presented and demonstrate the new sensor’s ability to measure fast intra-cycle gas-property transients, and provide insights relevant to advancing internal-combustion-engine technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Argon metastable dynamics and lifetimes in a direct current microdischarge

In this paper we study the properties of a pulsed dc microdischarge with the continuous flow of argon. Argon metastable lifetimes are measured by tunable diode laser absorption spectroscopy (TDLAS) and are compared with calculated values which yield information about excitation and de-excitation processes. By increasing the gas flow-rate about 5 times from 10 to 50 sccm, the Ar{sup m} lifetime increases from 1 to 5 μs due to the reduction of metastable quenching with gas impurities. Optical emission spectroscopy reveals nitrogen and water molecules as the main gas impurities. The estimated N₂ density [N₂]=0.1% is too low to explain the measured metastable lifetimes. Water impurity was found to be the main de-excitation source of argon metastable atoms due to high quenching coefficients. The water impurity level of [H₂O]=0.15% to 1% is sufficient to bring calculated metastable lifetimes in line with experiments. The maximum value of water content in the discharge compared to the argon atoms is estimated to approximately 6%, due to the large surface to volume ratio of the microdischarge. The current pulse releases the water molecules from the electrode surface and they are either re-adsorbed in the time between 0.4 ms for [H₂O]=1% and 2.6 ms for [H₂O]=0.15% or pumped out of the discharge with the speed equal to the gas flow-rate. Depending on its partial pressure, the water impurity re-adsorption time is of the order of magnitude or less then the argon gas residence time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

H 2 O absorption spectroscopy via focused laser differential interferometry

A modification of focused laser differential interferometry (FLDI) is demonstrated with an infrared tunable diode laser (TDL) to achieve simultaneous absorption spectroscopy (AS) measurements. Measurements from this absorbing-FLDI (A-FLDI) are shown for a Hencken burner plume. Initial comparison measurements are recorded using TDLAS and an electrical hygrometer. Raw voltage and estimated absorbance measurements illustrate that the technique detects five distinct absorbance peaks of the methane–air flame while retaining the expected behavior of typical FLDI. This modification furthers efforts to enable FLDI to conduct analysis of the pressures, temperatures, and molecular densities of flows. It also explores the potential for reducing path-integration (PI) effects in absorption spectroscopy and potentially enabling spatially and temporally resolved local flow measurements. Reductions in PI length as high as 82%–84% are observed.

Holladay, Seth (ORCID:0009000650875421)↗

Tunable Diode Laser Absorption Spectroscopy Using a Multi-Pass White Cell for O 2 Detection

Two forms of Tunable Diode Laser Absorption Spectroscopy (TDLAS), direct absorbance spectroscopy and wavelength modulation spectroscopy (WMS), for O 2 detection were carried out using a tunable 763-nm vertical cavity surface emitting laser (VCSEL) in a multi-pass White cell with an optical path length of 2.6 m. The cell was fitted with a gas flow mechanism for concentration studies. The output wavelength of the tunable VCSEL was increased by ramping the drive current from 0-5 mA while temperature controlling the device to 20 °C. The output wavelength of the VCSEL was mapped using a spectrum analyzer.

42 ENGINEERING↗

Final Report - Advanced Laser-Based Sensors for Industrial Process Control

The objective of this work is to capture the potential of real-time monitoring and overcome the challenges of harsh industrial environments, Los Gatos Research (LGR) is fabricating, deploying, and commercializing advanced laser-based gas sensors for process control monitoring in industrial furnaces (e.g. electric arc furnaces). These sensors can achieve improvements in process control, leading to enhanced productivity, improved product quality, and reduced energy consumption and emissions. The first sensor will utilize both mid-infrared and near-infrared lasers to make rapid in-situ measurements of industrial gases and associated temperatures in the furnace off-gas. The second sensor will make extractive measurements of process gases. During the course of this DOE project, Los Gatos Research (LGR) fabricated, tested, and deployed both in-situ tunable diode laser absorption spectrometry (TDLAS) analyzers and extractive Off-Axis Integrated Cavity Output Spectroscopy (Off-Axis ICOS) analyzers.

47 OTHER INSTRUMENTATION↗

Multi-Scale Integrated Monitoring System for Enhancing Methane Emission Detection, Quantification & Prediction

This report details the progress and findings of a comprehensive study on reviewing existing solutions, identifying technology gaps, and formulating an “all-in-one” integrated strategy for developing the next-generation multiscale methane monitoring and modeling platform, conducted under grant number DE-FE0032292. Co-led by Dr. David Ebert, Dr. Binbin Weng, and Dr. Chenghao Wang at the University of Oklahoma, the project’s goal was to develop an integrated approach for building this engineering platform to detect, quantify, and mitigate methane emissions across various temporal scale, spatial scales, and sectors. The planning grant study began with an extensive review of various methane sensing and monitoring technologies and systems, surveying over 100 technology providers globally. This review revealed the prevalence of optical methods over chemical methods in commercially available sensors, with Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), and Optical Gas Imaging (OGI) cameras being the most prevalent options. A trend towards more advanced optical techniques was observed, driven by increased regulatory focus and technological advancements. The technical evaluation of these sensing technologies provided crucial insights into their capabilities and limitations. The study examined emerging technologies such as Differential Absorption LiDAR (DIAL), which show promise for high-precision and long-range detection. The team then investigated the features and application bandwidth of various sensing platforms, including handheld, fixed/stationary, mobile, aerials, and spaceborne monitors. Pilot field studies were conducted to assess the capabilities of solutions for different emission scenarios. Field work with sensor deployments was conducted at three distinct site types: an oil & gas industry site, a cattle ranching operation, and a waste processing facility. The team also conducted a thorough review of methane flux inverse modeling approaches, focused on physically based methods. These approaches were categorized into simple, intermediate, and advanced methods. A realtime WRF-GHG (Weather Research and Forecasting-Greenhouse Gas) modeling system was developed and applied, incorporating multiple data sources to guide field experiments and inform methane plume detection. The project identified and analyzed numerous categories of methane data sources, including satellite measurements, ground-based sensors, and inventory databases. Key platforms examined include EDGAR, EPA GHGI, NASA TROPOMI, Carbon Mapper, and Climate TRACE, among others. The team proposed an architecture for a comprehensive methane monitoring platform. This system incorporates multi-source data acquisition, advanced data processing and assimilation, interactive visualization tools, and analytical capabilities for emissions forecasting and scenario analysis. The proposed platform aims to provide a user-friendly interface catering to various stakeholders, from researchers to policymakers. The architecture includes sophisticated data ingestion methods, a centralized data warehouse, and advanced analytical tools for data fusion and interpretation. To ensure the relevance and effectiveness of the proposed system, a comprehensive survey was conducted to gather stakeholder input on system requirements. Key findings include a strong need for integrating various data types and formats, a preference for real-time data updates and advanced visualization tools, and a demand for user-friendly interfaces catering to different expertise levels.

03 NATURAL GAS↗

MHz-rate Laser Spectroscopic Instrument for Reacting Flow Composition and Temperature Measurements inside Rotating Detonation Engines (RDEs)

Rotating Detonation Engine (RDE) is a concept with the potential of realizing a pressure gain architecture that will lead to improved efficiency in power generation and propulsion systems. However, there are many questions on stable operation and effectively recovering flow such that it may be used in power production. To this end, a Tunable Diode Laser Absorption Spectrometer (TDLAS) was developed which targets H2O at two wavelengths for resolving composition and static temperature of the reacting medium within an RDE combustion channel. Coupling this information with velocity measurements, the total pressure may be resolved. Preliminary results from application of the sensor to hydrogen fired Aerojet Rocketdyne engine test are discussed.

03 NATURAL GAS↗