A TID and SEE Characterization of Multi-Terabit COTS 3D NAND Flash

Single-event effects and total ionizing dose testing are described for a 32-layer NAND flash memory, in both SLC and MLC configurations, with special considerations for unique three-dimensional test results. Extraction of three-dimensional heavy-ion test data presents a unique visualization of angular effects in NAND flash. Pattern dependence differences between SLC and MLC mode are noted, along with slightly non-uniform angular cross-section results due to the complex volume. Finally, TID data under different operating and bias conditions shows that the failure point remains the higher-voltage erasure circuitry.

Flash Memory↗

Total Ionizing Dose (TID) Testing of the PA10 Power Operational Amplifier

This study was undertaken to determine the total ionizing dose (TID) sensitivity of the PA10 Power Op Amp Manufactured by APEX (figure 1), which is a candidate for use on the LDCM TIRS instrument. The test was conducted with interest in both parametric degradation and functional failure in the configuration like that of the TIRS application. (See figure 2). The DUT was irradiated in a stepwise fashion, with parametric and functional degradation measured between steps. The parts were irradiated with gamma rays at a low dose rate (~0.01 rads(Si)/sec.).

total ionizing dose (TID)↗

Investigation of temperature dependence of neutron yield and electron screening potential for the d(d, n){sup 3}He reaction proceeding in deuterides ZrD{sub 2} and TiD{sub 2}

The temperature dependence of the enhancement factor for the dd reaction proceeding in TiD{sub 2} and ZrD{sub 2} is investigated. The experiments were carried out at the Hall pulsed ion accelerator (INP, Polytechnic University, Tomsk, Russia) in the deuteron energy interval 7.0-12.0 keV and at temperatures ranging from 20 to 200 Degree-Sign C. The values obtained for the electron screening potentials indicate that the dd reaction enhancement factor does not depend on the target temperature in the range 20-200 Degree-Sign C. This result contradicts the conclusions drawn by the LUNA Collaboration from their work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-parameter tunable Tilt-Integral-Derivative (TID) controller

A feedback control system compensator of the PID type is provided, wherein the proportional component of the compensator is replaced with a tilted component having a transfer function s to the power of -1/n. The resulting transfer function of the entire compensator more closely approximates an optimal transfer function, thereby achieving improved feedback controller. Further, as compared to conventional PID compensators, the TID compensator allows for simpler tuning, better disturbance rejection ratio, and smaller effects of plant parameter variations on closed loop response.

Lurie, Boris J.↗

SEE and TID of emerging non-volatile memories

We report on the SEE and TID tests of higher density flash memories. Stand-by currents and full functional tests were used to characterize the response of radiation effects.

single-event upset non-volatile memories↗

Low Temperature (30 K) TID Test Results of a Radiation Hardened 128 Channel Serial-to-Parallel Converter

This viewgraph presentation reviews the low temperature, Total Ionizing Dose (TID) tests of radiation hardened serial to parallel converter to be used on the James Webb Space Telescope. The test results show that the original HV583 level shifter - a COTS part -was not suitable for JWST because the supply currents exceeded specs after 20 krad( Si) .The HV584 - functionally similar to the HV583 -was designed using RHBD approach that reduced the leakage currents to within acceptable levels and had only a small effect on the level-shifted output voltage.

Meyer, Stephen↗

TID Effects in Space-like Variable Dose Rates

The degradation of the LM193 dual voltage comparator has been studied with different types of TID dose rates. These include several different constant dose rates and a variable dose rate that simulates the behavior of a solar flare. The varying dose rate of a solar flare is the type of real total dose exposure that a space mission might see in lunar or Martian orbit. A comparison of these types of dose rates is made to explore how well the constant dose rates used for typical part testing predicts the performance during a simulated space-like mission.

enhanced low dose rate sensitivity (ELDRS)↗

Comparison of TID Effects in Space-Like Variable Dose Rates and Constant Dose Rates

The degradation of the LM193 dual voltage comparator has been studied at different TID dose rate profiles, including several different constant dose rates and a variable dose rate that simulates the behavior of a solar flare. A comparison of results following constant dose rate vs. variable dose rates is made to explore how well the constant dose rates used for typical part testing predict the performance during a simulated space-like mission. Testing at a constant dose rate equal to the lowest dose rate seen during the simulated flare provides an extremely conservative estimate of the overall amount of degradation. A constant dose rate equal to the average dose rate is also more conservative than the variable rate. It appears that, for this part, weighting the dose rates by the amount of total dose received at each rate (rather than the amount of time at each dose rate) results in an average rate that produces an amount of degradation that is a reasonable approximation to that received by the variable rate.

Solar Flare↗

Statistical Model Selection for TID Hardness Assurance

Radiation Hardness Assurance (RHA) methodologies against Total Ionizing Dose (TID) degradation impose rigorous statistical treatments for data from a part's Radiation Lot Acceptance Test (RLAT) and/or its historical performance. However, no similar methods exist for using "similarity" data - that is, data for similar parts fabricated in the same process as the part under qualification. This is despite the greater difficulty and potential risk in interpreting of similarity data. In this work, we develop methods to disentangle part-to-part, lot-to-lot and part-type-to-part-type variation. The methods we develop apply not just for qualification decisions, but also for quality control and detection of process changes and other "out-of-family" behavior. We begin by discussing the data used in ·the study and the challenges of developing a statistic providing a meaningful measure of degradation across multiple part types, each with its own performance specifications. We then develop analysis techniques and apply them to the different data sets.

Ladbury, R.↗

Compendium of Single Event Transient (SET) and Total Ionizing Dose (TID) Test Results for Commonly Used Voltage Comparators

This data compendium reports single event transient (SET) and total ionizing dose (TID) test results for commonly used commercial-off-the-shelf (COTS) and radiation hardened voltage comparators targeted for possible use in space-based missions. Interesting trends in the variability of the radiation performance of these devices due to differences in lot date codes, manufacturers, circuit design, and test conditions are analyzed herein.

Bozovich, Amanda↗

Development of TID Hardness Assurance Methodologies to Capitalize on Statistical Radiation Environment Models

We develop methods for bounding part-to-part variation in TID data. When used in conjunction with statistical radiation environment models, these methods allow development of RHA that deliver estimated piece part reliability for any desired confidence level, moving beyond risk avoidance methodologies based on radiation design margin. Two methods are developed, and their results compared for realistic data.

Total Ionizing Dose↗

Development of TID Hardness Assurance Methodologies to Capitalize on Statistical Radiation Environment Models

We develop methods for bounding part-to-part variation in TID data. When used in conjunction with statistical radiation environment models, these methods allow development of RHA that deliver estimated piece part reliability for any desired confidence level, moving beyond risk avoidance methodologies based on radiation design margin. Two methods are developed, and their results compared for realistic data.

Total ionizing dose↗

TID, SEE and radiation induced failures in advanced flash memories

We report on TID and SEE tests of multi-level and higher density flash memories. Stand-by currents and functionality tests were used to characterize the response of radiation-induced failures. The radiation-induced failures can be categorized as followings: SEU read errors during irradiation, stuck-bit read errors verified post-irradiation, write errors, erase failures, multiple upsets, and single-event latch up.

Scheick, Leif Z.↗