FUEL PERFORMANCE SIMULATION OF HIGH BURNUP FUELS IN PLANNED INTEGRAL DESIGN BASIS ACCIDENT EXPERIMENTS

High burnup (HBu) fuel rods from the Byron Nuclear Generating Station (BNGS) were recently received at Idaho National Laboratory (INL) to support a variety of planned Nuclear Energy fuel cycle R&D objectives ranging from fuel performance, fuel recycle, and spent fuel research topics. Among these R&D activities, these fuel rods will be the subjects of multiple in-pile experiment programs at the Transient Reactor Test (TREAT) facility as well as detailed characterization and testing in the hot cells at INL and Oak Ridge National Laboratory (ORNL). TREAT RIA experiments are planned for the Nuclear Energy Agency Framework for Irradiation Experiments (FIDES) Joint Experimental Program called High burnup Experiments in Reactivity Initiated Accident (HERA) program. TREAT and ORNL-furnace LOCA experiments are part of the Department of Energy (DOE) Advanced Fuels Campaign (AFC) program U.S. consensus LOCA test plan, and the in-pile experiments have also been proposed in a FIDES project called Loss of Coolant-High Burnup (LOC-HBu). The results of these test programs will provide crucial data about safety performance enabling extended licensable burnup limits for these fuels. The purpose of this paper is to document fuel performance computational simulations of the BNGS fuel using the Bison code. The detailed assessments include (1) the irradiation history of the fuel to provide prediction of as-run fuel conditions and (2) extending the irradiated fuel conditions into the as-designed experiment conditions for the HERA-HBu RIA experiments and for the LOC-HBu LOCA experiments. The results of these assessments will inform post-irradiation examinations (PIE) of the BNGS parent rods and detailed final design of the planned experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ARCS Replacement at TREAT for TRTR 2020 - Abstract

The Transient REActor Test (TREAT) facility was restarted in 2017 to perform reactor fuels testing under transient conditions, following shutdown in 1994 and 23 years in non-operational standby. TREAT is a transient reactor that, like most pulsing reactors, can create natural shaped power pulses. However, TREAT provides the ability to shape the power pulse and control the energy deposition rate on the test specimens by automatically controlling the amount of reactivity insertion over time. The original automatic reactor control system (ARCS) was created in the 1980s using INTEL 8086 CPU boards and software written in assembly code. The need to maintain the system for the next 40+ years of TREAT life led to the decision to replace ARCS with modern hardware while maintaining the original functionality. After a prototyping effort, the replacement was successfully completed in the first quarter of 2020. The process and results of that effort are reported here.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Combined TREAT-LOC & SATS Integral LOCA Experiment Plan

The Transient Reactor Test Facility (TREAT) loss-of-coolant (LOC) and highburnup (HBu) experiment series, along with the Severe Accident Test Station (SATS) HBu experiment series, are integral LOC accident (LOCA) experiments planned under the Department of Energy (DOE) Advanced Fuels Campaign (AFC) program, which aims to support burnup extension needs by addressing identified R&D priorities in order to achieve an improved understanding of fuel fragmentation, relocation, and dispersal (FFRD) of HBu fuel during LOCA events. Priorities have been identified by the Electric Power Research Institute (EPRI)’s Collaborative Research on Advanced Fuel Technologies (CRAFT) Fuel Performance and Testing Technical Experts Group (FPTTEG). The data produced under this plan will be used to further validate and confirm existing models and inform future R&D and model development. The experimental program was specifically developed to address data gaps and opportunities identified via detailed review of the existing public knowledge base on LOCA FFRD, as well as reviewing specific experimental development activities regarding prototypic LOCA conditions for light-water reactor (LWR) systems. The test program relies on a unique combination of in- and out-of-pile experimental approaches to provide a clear tieback to the existing integral and semi-integral LOCA experiment database, using state-of-the-art facilities. More importantly, the program will systematically investigate the impacts of prototypic HBu fuel/cladding thermomechanical behaviors under postulated LWR LOCA conditions not yet fully investigated. These conditions correspond with prototypic decay-energy heatup (DEH) and stored-energy heatup (SEH) conditions. First, TREAT’s unique capability will enable the first evaluation of the impact of SEH conditions on HBu fuels. The test program will emphasize the development of an improved mechanistic understanding of key phenomena through independent experimental systems, development of a database to support fuel performance modeling tools, world-leading advanced materials characterization, and the most advanced approach to in situ diagnostics ever deployed to evaluate FFRD. The results will represent a significant leap forward in evaluating prototypic conditions and novel data to support modeling development and validation, as well as to inform the technical basis for LOCA-induced FFRD.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HIGH BURNUP FUEL-COOLANT INTERACTION ANALYSIS SUPPORTING FUEL SAFETY TESTING AT IDAHO NATIONAL LABORATORY

In the near future, experiments on HBu fuel under loss-of-coolant accident (LOCA) and reactivity-initiated accident (RIA) conditions will be performed within the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL). These experiments will be performed using the Transient Water Irradiation System for TREAT (TWIST) experiment vehicle. To support these experiments, analysis of fuel-coolant interaction (FCI) energetics is underway. This paper discusses FCIs in the context of light water reactor (LWR) safety, differentiating between the severe accident focus of commercial reactors and experimental RIA test programs where FCIs have occurred. However, it is highlighted that as the nuclear industry aims for increased burnup limits, the FCI events observed in RIA test programs may become relevant to commercial LWR safety analysis. The paper then presents developments to the UW-FCI computer program to enable simulation of FCIs initiated by solid fuel particles dispersing into the coolant during RIAs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transient Testing of Nuclear Fuels Performed in the Original Operation of TREAT (2nd ed.)

This report provides summary information on experiments performed in the Transient Reactor Test Facility (TREAT) during its original operation from 1959-1994, and more specifically, before the TREAT core was upgraded at the end of the 1980s. The tests performed since about 1970 are summarized in considerable detail. Earlier tests are noted by their designated series and by some parameters that help to identify and distinguish each series from the others. The detailed summary descriptions are intended to help inform future researchers regarding the large, historical, empirical data base generated from that 35-year span during which hundreds of TREAT experiments were performed to investigate and demonstrate the transient behavior of a wide variety of nuclear fuels during severe off-normal and accident conditions -- using direct nuclear heating of the test samples. That empirical basis is foundational and valuable for guiding future qualification and safety evaluation of improved fuel designs and for future transient test planning and performance in TREAT. Since Edition 1 of this report, descriptions of the following test series have been added: D, E, EOS, F, H, J, R, RX, and S.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of the TREAT M2 experiment as a transient benchmark

A transient benchmark based on the Transient Reactor Test Facility (TREAT) M2 Calibration experiment (M2-CAL) is under development. TREAT, at Idaho National Laboratory, is a graphite moderated air-cooled research reactor which has been used extensively for fuel material testing under extreme and accident conditions. Accurate benchmark models are a beneficial component in the operations, experimental planning, and development of TREAT. In this work, we present a transient benchmark model for the M2-CAL experiment core loading. The benchmark model incorporates the coupling between the Monte Carlo Code SERPENT and the computational fluid dynamics code OpenFOAM to capture the temperature feedback mechanism. The M2-CAL transient 2580 was simulated in this work. A pre-transient analysis was performed to determine the optimum core composition and conditions before the beginning of the transient. The analysis was validated against historic TREAT kinetic measurements and the worth of the transient rod T-2. The axial power distribution in the flux wire for the M2-CAL experiment was determined and contrasted with the experiment. The model was then used to simulate the M2-CAL transient 2580 experiment based on the reported pre-transient and transient conditions. Several transient observables were calculated and compared to the experiment. The model shows good agreement with the experimental power traces, period, and average increase of power at the power ramp (time > 7.8 s). Inverse point kinetics analysis was performed during the period of the power ramp for the model and the experiment based on that, the temperature feedback component was isolated and contrasted with the experimental feedback. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Combined TREAT-LOC and SATS LOCA Experiment Plan: Integral LOCA Experiments on High-Burnup Fuels

The Transient Reactor Test Facility (TREAT) loss-of-coolant (LOC) and high-burnup (HBu) experiment series, along with the Severe Accident Test Station (SATS) HBu experiment series, are integral LOC accident (LOCA) experiments planned under the DOE AFC program, which aim to support burnup extension needs by addressing identified R&D priorities in order to achieve an improved understanding of fuel fragmentation, relocation, and dispersal (FFRD) of HBu fuel during LOCA events. The data produced under this plan will be used to further validate and confirm existing models and inform future R&D and model development. The experimental program has been specifically designed to address knowledge gaps and opportunities identified through a detailed review of existing public knowledge on LOCA FFRD. The test program employs a unique combination of in- and out-of-pile experimental approaches and state-of-the-art facilities to provide a clear connection to the existing integral and semi-integral LOCA experiment database. The primary goal of the program is to investigate the impact of prototypic HBu fuel/cladding thermomechanical behaviors under postulated LWR LOCA conditions that have not yet been fully studied. These conditions correspond with prototypic decay-energy heatup (DEH) and stored-energy heatup (SEH) conditions. Importantly, TREAT’s unique capability will enable the first evaluation of the impact of SEH conditions on HBu fuels. The test program will emphasize the development of an improved mechanistic understanding of key experimental phenomena through independent experimental systems, development of a database to support fuel performance modeling tools and employing world-leading advanced materials characterization and in-situ diagnostics to evaluate FFRD. The results of the program will provide novel data to support modeling development and validation and will represent a significant advancement in evaluating prototypic conditions, as well as to inform the technical basis for LOCA-induced FFRD.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Geophysical Characterization and Monitoring of the 200 Area Treated Effluent Disposal Facility to Support Permit Renewal; TEDF Geophysical Monitoring

The Treated Effluent Disposal Facility (TEDF), located in the 200 East Area of the Hanford Site, is a site where non-hazardous and non-radioactive liquid wastes are disposed into two state-permitted infiltration basins. In 2016, the Washington State Department of Ecology denied a permit renewal request for TEDF due to the inability to adequately assess the impact of TEDF discharge water on the underlying groundwater quality. TEDF overlies the relatively impermeable Ringold Lower Mud (RLM) unit, whose upper contact lies in the vadose zone approximately 30 m below ground surface and approximately 10 m above the water table boundary. The RLM is assumed to isolate TEDF discharge water from the natural groundwater aquifer, which is monitored using wellbores screened below the RLM. Therefore, samples collected from monitoring wells near TEDF are not considered representative of TEDF discharge water. Rather, TEDF discharge water is assumed to mound on top of the RLM to form a perched aquifer. To support permitting of the TEDF, a new monitoring well is required that can be used to sample water from the presumed perched water aquifer above the RLM. Ideally, the screened section of the well would be located at the peak of the perched water mound(s), which presumably occurs at the point of maximum vertical flux from TEDF to the RLM, or equivalently where the dominant infiltration flow paths reach the RLM. This report describes how time-lapse 3D electrical resistivity tomography (ERT) was used in conjunction with nominal TEDF discharge operations to image the dominant flow paths from each pond to the RLM. Results are summarized in Figure ES.1. Figure ES.1A shows a satellite image of the TEDF overlain by an array of surface ERT electrodes. The solid and dashed black circles denote the zones of maximum vertical flux at the RLM within the south and north ponds, respectively, and presumably the regions where perched water peaks during discharge. Figure ES.1B shows time-lapse difference imaging results approximately 15 days after switching discharge from the south pond to the north pond. Blue iso-surfaces beneath the north pond denote regions of increasing bulk electrical conductivity caused by increasing saturation due to infiltrating water. Red iso-surfaces beneath the south pond denote regions that were previously saturated during the south pond discharge and are now de-saturating, causing a decrease in bulk electrical conductivity. In both cases, the zones of maximum change mark the dominant flow paths to the RLM. Figure ES.1C shows time-lapse imaging results approximately 15 days after switching discharge from the north pond to the south pond. In this case, blue iso-surfaces mark the dominant flow paths to the RLM from the south pond. The red iso-surfaces mark the dominant flow paths that existed during discharge to the north pond. The regions of maximum change in bulk conductivity (due to saturation or desaturation) that mark the primary flow paths are equivalent in both cases and denoted by the dashed solid and black circles. If a perched water zone forms on the RLM, it is likely to mound within or near the dashed circle during discharge to the north pond, and in the solid circle during discharge to the south pond. In other words, if perched water mounding occurs, the circles mark the optimum locations suggested by the ERT imaging for monitoring boreholes to be placed, enabling samples to be collected that are representative of TEDF discharge impacts on groundwater quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resumption of water capsule reactivity-initiated accident testing at TREAT

A series of integral reactivity-initiated accident (RIA) commissioning experiments were completed in a new static water capsule in the Transient Reactor Test Facility (TREAT), marking the first such tests in the U.S. in more than 40 years. The test campaign included a verification test followed by five tests in the Static Environment Rodlet Transient Test Apparatus (SERTTA) capsule. The capsule initial conditions varied from room temperature and pressure up to 200°C and 2.5 MPa, with energy depositions varying between ~500–1100 J/gUO 2 . The series of tests allowed for a number of instrumentation qualifications and demonstrations, including cladding thermometry, rodlet plenum pressure, cladding elongation, and an electro-impedance boiling detector. Post transient examinations such as gamma emission spectroscopy, profilometry, and microscopy were performed to document the end state of the fuel rods. Furthermore, the results from the experiments show that the fuel rodlets behaved very similar to historical tests under similar energy depositions. This paper documents the design of the capsule and highlights some results from the commissioning tests and post-transient examination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transient Testing of Nuclear Fuels Performed in the Original Operation of TREAT (First Edition)

This report provides summary information on a selected set of key historic experiment series which were performed in the Transient Reactor Test Facility (TREAT) during its original operation from 1959-1994. The selected experiments are intended to illustrate the diversity in experiments which have been performed, and the range in capabilities of the TREAT reactor. Knowledge of those prior experiments provides a foundation for qualification and safety evaluation of numerous fuel forms already tested in TREAT, planning and designing new future tests, and for future TREAT operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coupled Thermal-Hydraulic and Fuel Performance Simulations of the TWIST LOCA Commissioning Test Series in TREAT

As the nuclear industry is looking to increase light water reactor (LWR) burnup limits, Idaho National Laboratory has developed an experiment vehicle for the Transient Reactor Test Facility (TREAT) to support high burnup fuel safety testing. One of the main purposes of this vehicle, known as the Transient Water Irradiation System for TREAT (TWIST), is to perform in-pile loss-of-coolant accident (LOCA) experiments on high burnup LWR fuel to investigate phenomena termed fuel fragmentation, relocation, and dispersal (FFRD). Prior to performing experiments on high burnup fuel specimens, a commissioning test series will be performed. The main purpose of the Loss-of-Coolant-Commissioning (LOC-C) test series is to qualify the TWIST device and validate the power coupling between TREAT and the TWIST fuel rod as well as validation of the thermal-hydraulic and fuel performance simulation predictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fuel Performance Simulation of High Burnup Fuels in Planned Integral Design Basis Accident Experiments

High burnup (HBu) fuel rods from the Byron Nuclear Generating Station (BNGS) were recently received at Idaho National Laboratory (INL) to support a variety of planned Nuclear Energy fuel cycle R&D objectives ranging from fuel performance, fuel recycle, and spent fuel research topics. Among these R&D activities, these fuel rods will be the subjects of multiple in-pile experiment programs at the Transient Reactor Test (TREAT) facility as well as detailed characterization and testing in the hot cells at INL and Oak Ridge National Laboratory (ORNL). TREAT RIA experiments are planned for the Nuclear Energy Agency Framework for Irradiation Experiments (FIDES) Joint Experimental Program called High burnup Experiments in Reactivity Initiated Accident (HERA) program. TREAT and ORNL-furnace LOCA experiments are part of the Department of Energy (DOE) Advanced Fuels Campaign (AFC) program U.S. consensus LOCA test plan, and the in-pile experiments have also been proposed in a FIDES project called Loss of Coolant-High Burnup (LOC-HBu). The results of these test programs will provide crucial data about safety performance enabling extended licensable burnup limits for these fuels. The purpose of this paper is to document fuel performance computational simulations of the BNGS fuel using the Bison code. The detailed assessments include (1) the irradiation history of the fuel to provide prediction of as-run fuel conditions and (2) extending the irradiated fuel conditions into the as-designed experiment conditions for the HERA-HBu RIA experiments and for the LOC-HBu LOCA experiments. The results of these assessments will inform post-irradiation examinations (PIE) of the BNGS parent rods and detailed final design of the planned experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mercury Modeling of TREAT Big-BUSTER Free Field Characterization Experiments

This report summarizes modeling of Big-BUSTER free field characterization (FFC) experiments at the Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) reactor performed from December 20th, 2023, to February 22nd, 2024. TREAT is an air-cooled graphite moderated research reactor that can be used to study material response to neutron irradiation. The BUSTER (Broad Use Specimen Transient Experiment Rig) refers to a containment module for placing experiments in the reactor core. The Big-BUSTER is an analogous platform for a modified core configuration with a larger experimental cavity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NCERC-CL TREAT Free Field Characterization Foil Reaction Rate Results

This report summarizes the analysis and preliminary MCNP reaction rate modeling of free field characterization measurements performed in the Transient Reaction Test Facility (TREAT) at Idaho National Laboratory (INL) between 12/18/2023 and 2/22/2024. A series of seven irradiations were performed using the Big-BUSTER (Broad Use Specimen Transient Experiment Rig) core configuration. Foil sets including 19.5% LEU-Zr alloy wire, S, Au, Fe, Ni, Co, Ti, and Zr were deployed in each irradiation. Identical foil sets were supplied to Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and INL. All foils were supplied by INL. Additional details on the experiment can be found in [2]. The foil sets were shipped to the National Criticality Experiments Research Center Counting Laboratory (NCERC-CL) branch at LANL (NCERC-CL NISC) and were received on 3/25/2024. Additional details on receipt and counting are reported in [3]. All reactor dosimetry measurements were performed in adherence to the ASTM standards applicable to reactor dosimetry. Measured reaction rates from Au, Co, Fe, Ni, and Ti are reported. Select reaction rate ratios and simulated reaction rates and ratios are discussed. Reaction rates for all measured reaction products were modeled with MCNP 6.3.1 and a TREAT input deck supplied by Edward Lum. Neutron emission estimates calculated using the measured and simulated reaction rates show excellent agreement between the three fast-threshold n-p reactions with the percent differences being < 9% between the three reactions. The capture reactions had poorer, but still reasonable, agreement with < 20% percent differences between the neutron emission estimates of the three capture reactions. The percent difference between the fast-threshold and capture reactions is ∼ 100% for each reaction. This supports the TREAT model is not accurately modeling the neutron spectrum and additional measurements are required to characterize TREAT and match measurements to simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Impact of Grain Size on Performance Degradation of TREAT LEU

We argue that radiation damage induced degradation of thermal conductivity does not set a lower limit on fuel grain sizes for the low enriched uranium fuel design of the Transient Reactor Test Facility (TREAT). Earlier work reports that smaller grains cause a larger degradation of thermal conductivity than larger grains constraining the smallest feasible size of fuel grains. This work assesses TREAT’s transient performance in the presence of radiation damage. The difference between the two studies is in treating damaged and fresh graphite as serial (this work) or parallel (previous) heat resistors. We use a multiphysics model of TREAT fuel grains to compute the reduction in transient capability measured by the total deposited energy as a function of irradiation dose. We find that radiation damage has a negligible effect on energy deposition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Expansion of the Fuel Motion Monitoring System

The Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System (FMMS) is a diagnostic tool used to visualize the movement and location of fuel within the nuclear reactor during transient experiments. TREAT is designed to test the behavior of nuclear fuel under accident conditions, such as a rapid power increase. The TREAT FMMS, also referred to as the “hodoscope” because of the system’s massive steel collimator component, is located on the North beam port of the reactor. While the FMMS system is capable of incorporating a total of 360 sensors, initial refurbishment efforts resulted in a array of 96 fast neutron detectors. This initial array was configured to provide a narrow (2 channels) full-length view of experiment vessels with an extended 4-channel–wide region in the center of the array capable of providing a full view of all initially planned experiments. Planning and efforts to expand the FMMS array began immediately following the restart of TREAT. An additional 96 detectors were evaluated, characterized, and prepared for installation at TREAT during the summer of 2018. Unfortunately, funding reductions forced the project towards a 5-year hiatus. In October of 2023 funding from the Department of Energy’s Nuclear Science User Facilities enabled the expansion to recommence. This report serves to document the activities performed to expand the FMMS detector array to 192 channels in order to provide a broader view of the larger and more sophisticated test capsules currently planned for future irradiation in the TREAT reactor. This expansion also included doubling the data acquisition capability, addressing the new heat load on the system, and synchronizing the time for all digital components.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Device for steam cladding oxidation testing at TREAT

To compare the chemical degradation of conventional zirconium alloy (Zry) cladding to advance silicon carbide (SiC) cladding in a post loss of coolant accident (LOCA) environment, new nuclear testing capabilities are necessary. The Transient Reactor Test (TREAT) Facility at Idaho National Laboratory (INL) has matured its transient fuel testing capabilities since its 2017 restart. The most recent experiment architecture is the Transient Water Irradiation System in TREAT (TWIST), which is designed to support qualification of accident tolerant fuels in light water reactors. INL has designed and analyzed a natural circulation steam flow modification for TWIST to produce prototypic conditions of cladding oxidation. The in-situ device will be electrically heated to drive natural circulation. Moreover, the SiC cladding requires heating above 1700 °C to observe failure, thus internal prototypic nuclear heating with radiation effects will be used. Thermal hydraulic analysis with RELAP5-3D (Reactor Excursion and Leak Analysis Program) estimated steam fluxes greater than 50 mg cm −2 s −1 can be achieved. These fluxes are adequate to test Zry cladding according to draft regulatory guides and to test SiC cladding according to past experiments.

Oxidation↗