Search NASA⌕ Search

SEARCH · Search NASA

Results for “TURBINES - BLADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Critical design load case fatigue and ultimate failure simulation for a 10-m H-type vertical-axis wind turbine

While previous studies investigating critical VAWT design load cases have focused on large and relatively flexible Darrieus designs, the bulk of current commercial products seeking certification fall in the relatively small, stiff, and H-type configuration, such as the XFlow Energy Corporation turbine that this study compares against. Understanding the critical design load case impacts for both fatigue and ultimate failure for this size and type of VAWT are imperative for certification. The abil

Brownstein, Ian↗

Bulb-style Kaplan Turbine - Run-of-the-river (ror) Hydro Governor And Turbine Model

This software package includes hydro governor and turbine models developed in Simulink (Mathworks Inc.) and RSCAD (RTDS Technologies) for low-head bulb-style Kaplan turbine hydropower plants. The model developed in Simulink has been designed and tuned to match the governor-turbine response for a real-world hydropower unit owned by Idaho Falls Power (IFP). The Simulink and RSCAD models enable real-time testing in a hardware-in-the-loop (HIL) implementation using OPAL-RT and RTDS digital real-time simulators, respectively. An automatic initialization for dynamic simulation has also been integrated to each model in both Simulink and RSCAD. The RSCAD initialization involves a novel python-based interfacing for automatic modification of the initial conditions in the model. The parameters of these models can be tuned to match other hydropower plants in this class.

Alam, SMShafiul↗

Computational Design to Advance AM Fabrication of High Gamma Prime Alloys for Hot Gas Path Components in Gas Turbine Engines: A Pathway to Enhanced Gas Turbine Efficiency and Energy Saving (Final CRADA Report)

Raising turbine inlet temperature is a key lever for improving industrial gas-turbine efficiency and power output, but it increases thermo-mechanical demands on hot-gas-path components. Additive manufacturing (AM), particularly laser powder bed fusion (L-PBF), enables complex internal cooling features in critical components such as turbine tip shoes that are difficult to produce by conventional casting. However, qualification of new high-temperature AM alloys and aggressive geometries is often limited by trial-and-error iteration of build parameters and post-build heat treatments, with cracking during stress relieving or hot isostatic pressing (HIP) being a recurring failure mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Turbine component and methods of making and cooling a turbine component

A turbine component includes a root and an airfoil extending from the root to a tip opposite the root. The airfoil forms a leading edge and a trailing edge portion extending to a trailing edge. Radial cooling channels in the trailing edge portion of the airfoil permit radial flow of a cooling fluid through the trailing edge portion. Each radial cooling channel has a first end at a lower surface at a root edge of the trailing edge portion or at an upper surface at a tip edge of the trailing edge portion and a second end opposite the first end at the lower surface or the upper surface. A method of making a turbine component and a method of cooling a turbine component are also disclosed.

Dutta, Sandip↗

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗

The Power Reclamation of Utilizing Micro-Hydro Turbines in the Aeration Basins of Wastewater Treatment Plants

Upgrading the aeration basin technology can improve the oxygen transfer efficiency (OTE), while keeping the energy consumption at its minimum level. Therefore, this paper introduces a new idea of installing micro-propeller turbines in the aeration basin of a wastewater treatment plant (WWTP) to extract power from the high-velocity location in the water column. This extracted power can be used to operate a mixer at the top of the membrane to induce the mixing in that region, which will drive the less oxygenated wastewater into the water column. The rest of the extracted power will rotate microturbine rotors for electric power generation. By applying the proposed microturbines to the 13 audited facilities, it was demonstrated to achieve a gross annual energy-savings of 3,836.9 MWh, a gross annual cost-saving of $260,497, and total CO 2 emissions that would be reduced by 2,714 metric tons/year. Generally, the addition of the proposed microturbines can save up to 15.7% of the annual plant electricity consumption (1.3–12.8% of the plant annual electricity bills).

13 HYDRO ENERGY↗

Predicting EBC Temperature Limits for Industrial Gas Turbines

Higher turbine inlet temperatures may require the use of ceramic matrix composites (CMC) such as SiC/SIC, which require environmental barrier coatings (EBCs) to protect them against the detrimental effect of water vapor. Here, the goal of this project is to determine the maximum bond coating temperature for EBCs for land-based turbines, where the minimum coating lifetime is 25,000 h. If the temperature exceeds the 1414°C melting point of the Si bond coating, then coatings without a bond coating also need to be evaluated. Thus, current Yb 2 Si 2 O 7 EBCs with a Si bond coating and next-generation EBCs without a Si bond coating are being evaluated in laboratory testing using 1-h cycles in air+90%H 2 O. For this initial work, coatings were deposited on CVD SiC coupons. Reaction kinetics at 1250°, 1300° and 1350°C have been evaluated by measuring the thickness of the thermally grown silica scale after 100–500 h exposures. For comparison, scale growth rates for uncoated SiC and Si specimens in dry and wet environments were included as minimum and maximum values, respectively. Based on a critical scale thickness failure criteria, estimated maximum temperatures were calculated for both EBC systems using this initial data.

42 ENGINEERING↗

Floating Wind Turbine Control Optimization

We present a framework for optimizing the control parameters of floating offshore wind turbines (FOWTs). The framework combines aeroelastic simulations with a systems engineering model and control software. In an example of the optimization framework, we minimize tower damage equivalent loading with generator speed constraints. We also study the effect of thrust-limiting control and quantify the trade off between fatigue loading and energy capture using a set of optimal controller designs. Finally, we optimize the controller of four different FOWT models and compare their dynamic responses. Additional details and other use cases for the framework are presented, which can optimize different control problems and evaluate FOWT designs.

controls↗

Optimization and Comparison of Modern Offshore Wind Turbine Generators Using GeneratorSE 2.0

As the offshore wind industry keeps growing at a rapid pace, developers are bracing themselves for a huge demand in critical rare earth metals which will threaten an already vulnerable supply chain. The wind energy industry is addressing this problem by investing in modern generator technologies that employ magnets with reduced rare earth content and high-field magnets enabled by rare-earth-free superconductors. In this paper we introduce the National Renewable Energy Laboratory's newly advanced GeneratorSE 2.0, which is a design and optimization tool that was developed to investigate the feasibility of such modern generators. Two direct-drive generator topologies with different magnet materials and mounting arrangements are investigated: an outer-rotor, V-shaped interior permanent magnet generator, and an inner-rotor normally conducting armature, paired with a low-temperature superconducting field with race-track coils. These technologies were evaluated for a range of power ratings between 15 and 25 MW, which represent the next generation of offshore wind turbines for both fixed-bottom and floating applications. The analyses indicate a new trend favoring the low-temperature superconducting technology for the direct-drive system.

direct-drive generators↗

Apparatus, turbine nozzle and turbine shroud

An apparatus is disclosed including a first and second article, a first interface volume disposed between and enclosed by the first article and second article, a cooling fluid supply, and at least one cooling fluid channel in fluid communication with the cooling fluid supply and the first interface volume. The first article includes a first material composition. The second article includes a second material composition. The at least one cooling fluid channel includes a heat exchange portion disposed in at least one of the first and second article downstream of the cooling fluid supply and upstream of the first interface volume. A turbine shroud is disclosed wherein the first and second articles are an outer and inner shroud. A turbine nozzle is disclosed wherein the first and second articles are an endwall and fairing.

36 MATERIALS SCIENCE↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant (2x2x1 Duct-Fired 758-MWe Facility with F Class Turbines)

A comprehensive front-end engineering design (FEED) study has been undertaken by Bechtel National Inc. (Bechtel) for locating a post-combustion capture and compression (PCC) unit at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in the unredacted FEED Study report (Attachment 1) with all supporting documents, numbering over 150. The Study Report is publicly available. Sizing of the PCC plant is based on treating an amount of flue gas equivalent to that produced when generating 420 MW, which is approximately 68% of the total flue gas emitted by the NGCC power plant operating at guarantee condition with duct burners off. A reduced power plant capacity factor was used for sizing the PCC plant because the gas turbines at the site often operate at reduced load due to the high penetration of renewable power in the ERCOT region. The cost of carbon capture is primarily driven by capital cost (and therefore is highly sensitive to capacity factor). Sizing the capture unit so that when used it is nearly always operating at full capacity is critical to the economic viability of the proposed investment.

03 NATURAL GAS↗

An Intermediate-Scale Version of the Volturnus + Floating Offshore Wind Turbine Platform Concept in a Real Ocean Environment with an Operating Turbine off the Coast of Maine (Final Scientific/Technical Report)

This project was undertaken to advance the technical readiness and commercial viability of a next-generation, industrialized concrete floating foundation for offshore wind turbines called VolturnUS +. The design objective is to deliver a platform that is lower cost, faster to manufacture, simpler to deploy, and optimized for domestic supply chains and local workforce participation. To enable project financing and commercial adoption, an at-sea demonstration under representative operating conditions was required and therefore this project aimed to deploy a ¼-scale VolturnUS+ prototype offshore the Coast of Maine.

17 WIND ENERGY↗