Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Qualification Device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Applications of Fracture Mechanics to Quantitative Accelerated Life Testing of Plastic Encapsulated Microelectronics

Accelerated testing must address the failure mechanisms active within the devices undergoing tests in order to assess lifetimes in a meaningful way. The assumption of constant temperature, thermally activated lifetime, based upon the Arrhenius assumptions, does not always provide the necessary understanding to interpret accelerated tests in microelectronics. Plastic encapsulants, dielectric polymers, and underfill materials are subject to delamination and cracking with thermal cycling. Crack propagation during use environment exposure, drives the potential for failure of microelectronic devices and is therefore a necessary focal point in qualification and life testing. This paper reviews the available research in the application of fracture mechanics to this class of problems in microelectronics including relevant test data. In addition, useful acceleration factor models are derived for polymer crack propagation based on principles of linear elastic fracture mechanics. Further, a simple approach to estimating the minimum temperature cycling ranges, necessary to propagate a crack, is also presented. Finally, a methodology of applying acceleration factors to develop testing plans is shown, with an example in spaceflight for a cubesat in low Earth orbit. Overall, this is a paper that shows a useful and appropriate process for creating physics of failure based life testing for delamination and cracking failures in microelectronic polymers in a temperature cycling environment.

Accelerated testing↗

Centrifugal regulator for control of deployment rates of deployable elements

The requirements, design, and performance of a centrifugal regulator aimed at limiting deployment rates of deployable elements are discussed. The overall mechanism is comprised of four distinct functional parts in a machined housing: (1) the centrifugal brake device, which checks the payout of a deployment cable; (2) the reducing gear, which produces the spin rate necesary for the braking device; (3) the payout device, which allows the unwinding of the cable; and (4) the locking device, which prevents untimely unwinding. The centrifugal regulator is set into operation by a threshold tension of the cable which unlocks the mechanism and allows unwinding. The pulley of the windout device drives the centrifugal brake with the help of the reducing gear. The centrifugal force pushes aside weights that produce friction of the studs in a cylindrical housing. The mechanism behaved well at qualification temperature and vibrations.

Vermalle, J. C.↗

Space Cryogenic Workshop, 8th, California Institute of Technology, Pasadena, July 31, Aug. 1, 1989, Proceedings

Recent advances in cryogenic technology for space applications are examined in reviews and reports. Topics addressed include very-low-force cooling contacts for the ISO cryostat cover, convective heat flow in space cryogenics plugs, liquid-acquisition devices for superfluid He transfer, and pressure drop in the SHOOT superfluid-He acquisition system. Consideration is given to a liquid-He vibration cryostat for space qualification tests, closed-cycle coolers for temperatures below 30 K, stress analysis down to liquid-He temperature, a cryogenic valve actuator, and a spaceborne He-3 refrigerator. Also discussed are an adiabatic-demagnetization refrigerator for SIRTF, rejection of waste heat from O liquefaction operations at a lunar O production plant, SHOOT flowmeter and pressure transducers, and space qualification of the ISO cryogenic rupture disks.

Source record↗

Techniques for control of long-term reliability of complex integrated circuits. I - Reliability assurance by test vehicle qualification.

Development of an alternate approach to the conventional methods of reliability assurance for large-scale integrated circuits. The product treated is a large-scale T squared L array designed for space applications. The concept used is that of qualification of product by evaluation of the basic processing used in fabricating the product, providing an insight into its potential reliability. Test vehicles are described which enable evaluation of device characteristics, surface condition, and various parameters of the two-level metallization system used. Evaluation of these test vehicles is performed on a lot qualification basis, with the lot consisting of one wafer. Assembled test vehicles are evaluated by high temperature stress at 300 C for short time durations. Stressing at these temperatures provides a rapid method of evaluation and permits a go/no go decision to be made on the wafer lot in a timely fashion.

Van Vonno, N. W.↗

A Spacecraft Housekeeping System-on-Chip in a Radiation Hardened Structured ASIC

Housekeeping systems are essential to health monitoring of spacecraft and instruments. Typically, sensors are distributed across various sub-systems and data is collected using components such as analog-to-digital converters, analog multiplexers and amplifiers. In most cases programmable devices are used to implement the data acquisition control and storage, and the interface to higher level systems. Such discrete implementations require additional size, weight, power and interconnect complexity versus an integrated circuit solution, as well as the qualification of multiple parts. Although commercial devices are readily available, they are not suitable for space applications due the radiation tolerance and qualification requirements. The Housekeeping System-o n-A-Chip (HKSOC) is a low power, radiation hardened integrated solution suitable for spacecraft and instrument control and data collection. A prototype has been designed and includes a wide variety of functions including a 16-channel analog front-end for driving and reading sensors, analog-to-digital and digital-to-analog converters, on-chip temperature sensor, power supply current sense circuits, general purpose comparators and amplifiers, a 32-bit processor, digital I/O, pulse-width modulation (PWM) generators, timers and I2C master and slave serial interfaces. In addition, the device can operate in a bypass mode where the processor is disabled and external logic is used to control the analog and mixed signal functions. The device is suitable for stand-alone or distributed systems where multiple chips can be deployed across different sub-systems as intelligent nodes with computing and processing capabilities.

Suarez, George↗

Space-qualified Chalcogenide Materials through ISS MISSE Exposure —From Property to Application

In March 2021, twenty-four samples of various phase change materials (PCMs - Ge2Sb2Te5, Ge2Sb2Se4Te1, and Sb2Se3) along with metasurface optical components comprised of these PCMs, were delivered to the International Space Station (ISS) as part of the Materials International Space Station Experiment (MISSE-14) test campaign [1]. Although PCMs have previously been noted for their resilience to various forms of radiation [2], they had not been tested in a realistic space environment until this exposure campaign with joint NASA and MIT collaboration. During the six-month total open exposure time in low earth orbit (LEO), high-resolution cameras scanned and captured photographs of the samples to detect changes as a function of time along with on-orbit measured temperature, UV radiation, total atomic oxygen fluence, and total ionizing radiation doses. The samples were returned to NASA Langley Research Center in March 2022 for post-flight characterization. This duplicated the preflight characterization (i.e., material composition and crystallinity that limits switching speed, index contrast, loss, etc.) conducted before launch. The space sector has witnessed tremendous growth within the past decade—not only from government agencies but also entrants from the private sector. Future growth in the capabilities of Earth observation, deep space, and planetary surface missions using miniaturized spacecraft platforms can only be sustained by innovations in the design of remote sensors and other sub-systems. Active metasurface optics with enhanced tunability and reconfigurability continues to redefine the boundaries of optical science [3]. The introduction of PCM technology and associated optical devices will help to accelerate the adoption of new architectures for reduced size, weight, power, and cost (SWaP-C) platforms in space.Here we introduce results obtained from the MISSE-14 mission related to space qualification of PCM-based optic devices and constituent materials. We then discuss our recent work developing active integrated photonic devices and metasurface optics based on PCMs for space applications. This includes tunable and reconfigurable optical metasurface devices to support NASA space communication and LIDAR applications. PCMs are quickly becoming interesting photonics materials but questions related to mission suitability remain, particularly in regard to key properties like figures-of-merit (FOM, Δn/Δk), glass forming temperatures, and phase transition speeds. This talk will describe efforts to afford researchers the ability to have access to cost-effective data on exposure-induced changes to PCM fundamental physical and optical properties to assess their utility for space applications. The MISSE-14 sample exposure campaign allows a complete understanding of the limitations of the PCMs for various space-based electronic and optoelectronic applications.

Chalcogenide Phase change material↗

Impacts of Substrate Thinning on FPGA Performance and Reliability [Slides]

Substrate thinning is necessary in devices with flip-chip BGA packages to enable both radiation testing and component qualification and high-spatial resolution beam-based failure analysis methods. We investigated three factors affecting device performance: subsurface damage from the thinning process, reduced heat spreading in thin substrates, and changes in device switching speed. We conclude subsurface damage to crystalline Si caused by the thinning process is removable with sufficient SiO 2 slurry polishing. Local temperature differences increase minimally in devices thinned to 3 μm. Compressive stress in the Si increases globally after device thinning and leads to slowing of ring oscillator frequency by about 0.5% compared to full-thickness devices. Future work will include extending the results to submicron Si thickness values, which also has important benefits for failure analysis, debug, and security assessments. We also plan to extend this type of work to other FPGAs and other devices like memory and processors.

36 MATERIALS SCIENCE↗

Qualification of Laser Diode Arrays for Mercury Laser Altimeter

NASA's requirements for high reliability, high performance satellite laser instruments have driven the investigation of many critical components; specifically, 808 nm laser diode array (LDA) pump devices. Performance of Quasi-CW, High-power, laser diode arrays under extended use is presented. We report the optical power over several hundred million pulse operation and the effect of power cycling and temperature cycling of the laser diode arrays. Data on the initial characterization of the devices is also presented.

Stephen, Mark↗

Advanced instrumentation and analysis methods for in-pile thermal and nuclear measurements: from out-of-pile studies to irradiation campaigns

Research and development on nuclear fuel behavior under irradiations and accelerated ageing of structure materials is a key issue for sustainable nuclear energy in order to meet specific needs by keeping the best level of safety. A new Material Testing Reactor (MTR), the Jules Horowitz Reactor (JHR) currently under construction in the South of France in the CEA Cadarache research centre will offer a real opportunity to perform R and D programs and hence will crucially contribute to the selection, optimization and qualification of innovative materials and fuels. To perform such programs advanced accurate and innovative experiments, irradiation devices that contain material and fuel samples are required to be set up inside or beside the reactor core. These experiments needs beforehand in situ and on line sophisticated measurements to accurately reach specific and determining parameters such as thermal and fast neutron fluxes, nuclear heating and temperature conditions to precisely monitor and control the conducted assays. Consequently, since 2009 CEA and Aix-Marseille University collaborate in order to design and develop a new multi-sensor device which will be dedicated to measuring profiles of such conditions inside the experimental channels of the JHR. These works are performed in the framework of two complementary joint research programs called MAHRI-BETHY and INCORE. These programs couple experimental studies carried out both out-of nuclear fluxes (in laboratory) and under irradiation conditions (in OSIRIS MTR reactor in France and MARIA MTR reactor in Poland) with numerical works realized by thermal simulations (CAST3M code) and Monte Carlo simulations (MCNP code). These programs deal with three main aims. The first one corresponds to the design and/or the test of new in-pile instrumentation. The second one concerns the development of advanced calibration procedures in particular in the case of one specific sensor: a differential calorimeter used to quantify nuclear heating. The last one consists in the development of accurate measurement and analysis methods. The paper will be dedicated to a complete review of the experimental and numerical works performed since 2009 thanks to two parts. The first part will detail a new thermal approach implemented to improve nuclear heating measurements by radiometric calorimeters. New experimental tools (calorimeter prototypes and set-ups such BETHY Bench) developed to perform preliminary out-of-pile studies under suitable conditions will be presented (temperature and velocity of the external cooling fluid, heat source localization and intensity inside the calorimetric cells). Then the response of two kinds of sensors, their calibrations curves and their thermal behaviors will be compared for various parameters. Finally validated numerical thermal and Monte Carlo works will be discussed to propose new improvements. The second parts of the paper will focus on works realized in order to design, develop and test the first prototype of the multi-sensor device called CARMEN [7-9]. The two mock-ups dedicated respectively to neutron measurements and photon measurements will be detailed. The results obtained during two irradiation campaigns inside the periphery of OSIRIS reactor will be shown. The new analysis method will be discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PEM-INST-001: Instructions for Plastic Encapsulated Microcircuit (PEM) Selection, Screening, and Qualification

Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.

Teverovsky, Alexander↗

Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 1

Electrical characterization and qualification tests were performed on the RCA MWS5001D, 1024 by 1-bit, CMOS, random access memory. Characterization tests were performed on five devices. The tests included functional tests, AC parametric worst case pattern selection test, determination of worst-case transition for setup and hold times and a series of schmoo plots. The qualification tests were performed on 32 devices and included a 2000 hour burn in with electrical tests performed at 0 hours and after 168, 1000, and 2000 hours of burn in. The tests performed included functional tests and AC and DC parametric tests. All of the tests in the characterization phase, with the exception of the worst-case transition test, were performed at ambient temperatures of 25, -55 and 125 C. The worst-case transition test was performed at 25 C. The preburn in electrical tests were performed at 25, -55, and 125 C. All burn in endpoint tests were performed at 25, -40, -55, 85, and 125 C.

Klute, A.↗

Comprehensive Radiation Testing of Uncooled, Free Space Coupled, InGaAs Quad Photoreceivers

We have comprehensively tested uncooled, free space coupled, InGaAs Quad Photoreceivers having 0.5mm, 1mm, and 2mm diameter integrated with a low noise transimpedance amplifier (TIA)using 30MeV Protons, 100MeV Protons, 662keV Gamma Rays, 1GeV/n Helium, and 1GeV/n Iron at room temperature of ~20°C.These devices find multiple applications in space for differential wave front sensing as part of a Gravitational Wave Observatory, as well as instrumentation and control for next generation space telescopes. The bandwidth of all receivers was 20MHz which was TIA limited. All 0.5mm and 1mm devices were found to be fully functional at normal operating conditions and at room temperature for Protons, Gamma Rays, 1GeV/n Helium, and 1GeV/n Iron. Only one quadrant of a 2mm In GaAs Quad had hard failure due to 1GeV/n Helium Ions; otherwise it too survived all other radiation tests. Detailed test results follow in the manuscript including recommendations for future space flights. These radiation test results, combined with the earlier successful mechanical shock and vibration testing mean these devices have passed preliminary testing for space qualification.

Abhay M Joshi↗

Testing Instrument Extremes in the TREAT Facility

TREAT is a transient power-shaping reactor whose primary mission is to enhance safety performance by testing nuclear fuels and materials under thermodynamic and neutronic conditions ranging from off-normal to extreme. Transient testing of nuclear fuels is analogous to car crash testing, in that the dramatic changes commonly seen when comparing the test specimens' initial and final state points necessitate in-situ measuring in order to interpret and understand the evolution of the experiment. TREAT’s experiment design strategy utilizes a highly reconfigurable and accessible reactor core that affords flexibility when installing experiment devices, thanks to the lack of a primary coolant boundary and the inclusion of multiple access points in the reactor bioshield. Within the experiment devices, the test specimens (which are integrated with their test environments), desired instrumentation diagnostics, and safety considerations are all contained in a single engineered package. The experiments encompass various types of environments (e.g., water, sodium, and gas at temperature and pressure), as well as a range of control options (e.g., static or flowing coolants). The experimental conditions are uniquely representative of advanced reactors, providing challenges to sensor performance but also affording a unique opportunity for development and qualification of sensors suited to these environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development, qualification, and delivery of a hydrogen burnoff igniter

The hydrogen burnoff igniter, a pyrotechnic device used to burn off excess hydrogen gas near the Space Shuttle Main Engine (SSME) nozzle, was designed, fabricated, and qualified. Characteristics of the burnoff igniter include a function time of 8 + or - 2 seconds, a minimum three foot flame length at maximum output, and hot particles projected 15 feet when fired directly into or perpendicular to a 34.5 knot wind. The three foot flame length was considered to be of questionable importance, since the hot particles are the media for igniting the hydrogen. Flame temperature is greater than 1500 F.

Ray, D.↗

4H-SiC JFET Multilayer Integrated Circuit Technologies Tested Up to 1000 K

Testing of semiconductor electronics at temperatures above their designed operating envelope is recognized as vital to qualification and lifetime prediction of circuits. This work describes the high temperature electrical testing of prototype 4H silicon carbide (SiC) junction field effect transistor (JFET) integrated circuits (ICs) technology implemented with multilayer interconnects; these ICs are intended for prolonged operation at temperatures up to 773K (500 C). A 50 mm diameter sapphire wafer was used in place of the standard NASA packaging for this experiment. Testing was carried out between 300K (27 C) and 1150K (877 C) with successful electrical operation of all devices observed up to 1000K (727 C).

JFET↗

Development of design, qualification, screening, and application requirements for plastic encapsulated solid-state devices for space applications

Test data were collected on 1035 plastic encapsulated devices and 75 hermetically scaled control group devices that were purchased from each of five different manufacturers in the categories of (1) low power Schottsky TTL (bipolar) digital circuits; (2) CMOS digital circuits; (3) operational amplifier linear circuits; and (4) NPN transistors. These parts were subjected to three different initial screening conditions, then to extended life testing, to determine any possible advantages or trends for any particular screen. Several tests were carried out in the areas of flammability testing, humidity testing, high pressure steam (auroclave) testing, and high temperature storage testing. Test results are presented. Procurement and application considerations for use of plastic encapsulated semiconductors are presented and a statistical analysis program written to study the log normal distributions resulting from life testing is concluded.

Source record↗

Experimental Durability Testing of 4H SiC JFET Integrated Circuit Technology at 727 C

We have reported SiC integrated circuits (IC's) with two levels of metal interconnect that have demonstrated prolonged operation for thousands of hours at their intended peak ambient operational temperature of 500 C [1, 2]. However, it is recognized that testing of semiconductor microelectronics at temperatures above their designed operating envelope is vital to qualification. Towards this end, we previously reported operation of a 4H-SiC JFET IC ring oscillator on an initial fast thermal ramp test through 727 C [3]. However, this thermal ramp was not ended until a peak temperature of 880 C (well beyond failure) was attained. Further experiments are necessary to better understand failure mechanisms and upper temperature limit of this extreme-temperature capable 4H-SiC IC technology. Here we report on additional experimental testing of custom-packaged 4H-SiC JFET IC devices at temperatures above 500 C. In one test, the temperature was ramped and then held at 727 C, and the devices were periodically measured until electrical failure was observed. A 4H-SiC JFET on this chip electrically functioned with little change for around 25 hours at 727 C before rapid increases in device resistance caused failure. In a second test, devices from our next generation 4H-SiC JFET ICs were ramped up and then held at 700 C (which is below the maximum deposition temperature of the dielectrics). Three ring oscillators functioned for 8 hours at this temperature before degradation. In a third experiment, an alternative die attach of gold paste and package lid was used, and logic circuit operation was demonstrated for 143.5 hours at 700 C.

JFET↗

Experimental Durability Testing of 4H SiC JFET Integrated Circuit Technology at 727 Degrees Centigrade

We have reported SiC integrated circuits (ICs) with two levels of metal interconnect that have demonstrated prolonged operation for thousands of hours at their intended peak ambient operational temperature of 500 degrees Centigrade. However, it is recognized that testing of semiconductor microelectronics at temperatures above their designed operating envelope is vital to qualification. Towards this end, we previously reported operation of a 4H-SiC JFET IC ring oscillator on an initial fast thermal ramp test through 727 degrees Centigrade. However, this thermal ramp was not ended until a peak temperature of 880 degrees Centigrade (well beyond failure) was attained. Further experiments are necessary to better understand failure mechanisms and upper temperature limit of this extreme-temperature capable 4H-SiC IC technology.Here we report on additional experimental testing of custom-packaged 4H-SiC JFET IC devices at temperatures above 500 degrees Centigrade. In one test, the temperature was ramped and then held at 727 degrees Centigrade, and the devices were periodically measured until electrical failure was observed. A 4H-SiC JFET on this chip electrically functioned with little change for around 25 hours at 727 degrees Centigrade before rapid increases in device resistance caused failure. In a second test, devices from our next generation 4H-SiC JFET ICs were ramped up and then held at 700 degrees Centigrade (which is below the maximum deposition temperature of the dielectrics). Three ring oscillators functioned for 8 hours at this temperature before degradation. In a third experiment, an alternative die attach of gold paste and package lid was used, and logic circuit operation was demonstrated for 143.5 hours at 700 degrees Centigrade.

Silicon Carbide↗