Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Estimating Temperature Rise Due to Flashlamp Heating Using Irreversible Temperature Indicators

One of the nondestructive thermography inspection techniques uses photographic flashlamps. The flashlamps provide a short duration (about 0.005 sec) heat pulse. The short burst of energy results in a momentary rise in the surface temperature of the part. The temperature rise may be detrimental to the top layer of the part being exposed. Therefore, it is necessary to ensure the nondestructive nature of the technique. Amount of the temperature rise determines whether the flashlamp heating would be detrimental to the part. A direct method for the temperature measurement is to use of an infrared pyrometer that has much shorter response time than the flash duration. In this paper, an alternative technique is given using the irreversible temperature 'indicators. This is an indirect technique and it measures the temperature rise on the irreversible temperature indicators and computes the incident heat flux. Once the heat flux is known, the temperature rise on the part can be computed. A wedge shaped irreversible temperature indicator for measuring the heat flux is proposed. A procedure is given to use the wedge indicator.

Koshti, Ajay M.↗

Failure Analysis of Gas Spray Atomization Crucible Materials

An attempted induction melt for gas spray atomization of a Pd alloy at Savannah River National Laboratory experienced a series of faulty thermocouple readings leading to failure of multiple alumina ceramic components and the loss of the metal charge. The spherical powders are used in research and development efforts for hydrogen storage applications. The failure of the thermocouples led to high operating temperatures exceeding the expected operating temperatures. Estimated temperatures of the liquid metal were established by the comparison of the radio frequency power output and multiple temperature readings and determined to have exceeded the functional temperature range of the alumina components. Failure analyses of the event included characterization of the components using visual observation and X-Ray computed tomography of the frozen ingot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An algorithm for the estimation of water temperatures from thermal multispectral airborne remotely sensed data

A method for water temperature estimation on the basis of thermal data is presented and tested against NASA's Thermal IR Multispectral Scanner. Using realistic bounds on emissivities, temperature bounds are calculated and refined to estimate a tighter bound on the emissivity of the source. The method is useful only when a realistic set of bounds can be obtained for the emissivities of the data.

Jaggi, S.↗

External auditory canal temperature as an estimate of core temperature.

Measurement of rectal (T sub re), auditory canal (T sub ac), positioned 8 to 10 mm from the tympanic membrane, and mean skin temperature (mean T sub sk) in five men during various exercise regimens at an ambient temperature (T sub a) of 25 C (phase one) and in two men during rest and exercise at 5, 15, 25, and 35 C T sub a (phase two). The purpose was to determine if T sub ac can be used as an accurate estimate of core temperature. Previous observations that T sub ac was highly correlated with T sub re but T sub ac was consistently lower than T sub re are confirmed; the mean difference varied from 0.4 C at rest to 1.1 C at the end of exercise. It is concluded that auditory canal temperature cannot be utilized as an estimate of core temperature, but T sub ac may be used to estimate mean body temperature where very accurate measurements are not required.

Greenleaf, J. E.↗

Estimating urban temperature bias using polar-orbiting satellite data

Urban temperature bias, defined to be the difference between a shelter temperature reading of unknown but suspected urban influence and some appropriate rural reference temperature, is estimated through the use of polar-orbiting satellite data. Predicted rural temperatures, based on a method developed using sounding data, are shown to be of reasonable accuracy in many cases for urban bias assessments using minimum temperature data from selected urban regions in the United States in July 1989. Assessments of predicted urban bias were based on comparisons with observed bias, as well as independent measures of urban heat island influence, such as population statistics and urban-rural differences in a vegetation index. This technique provides a means of determining urban bias in regions where few if any rural reference stations are available, or where inhomogeneities exist in land surface characteristics or rural station locations.

Johnson, Gregory L.↗

Estimating surface temperature in forced convection nucleate boiling - A simplified method

A simplified expression to estimate surface temperatures in forced convection boiling was developed using a liquid nitrogen data base. Using the principal of corresponding states and the Kutateladze relation for maximum pool boiling heat flux, the expression was normalized for use with other fluids. The expression was applied also to neon and water. For the neon data base, the agreement was acceptable with the exclusion of one set suspected to be in the transition boiling regime. For the water data base at reduced pressure greater than 0.05 the agreement is generally good. At lower reduced pressures, the water data scatter and the calculated temperature becomes a function of flow rate.

Hendricks, R. C.↗

Effect of chlorofluoromethane infrared radiation on zonal atmospheric temperatures

Estimates are made of changes in the atmospheric climate due to the radiative effects of 10 ppb of chlorofluoromethanes (CFM's). The estimates are derived on the basis of a 12-layer stratospheric general circulation model with a specified change of ocean temperature. Two tropical maxima in zonal average temperature change were observed: one in the upper troposphere and one centered at the tropopause. The temperature change exceeds the surface temperature change by a factor of at least two. If the 1975 CFM emission rate were to continue indefinitely, stratospheric water-vapor concentrations would increase by up to 60% due to CFM radiative effects. This would reduce ozone concentrations by an additional 4% of the natural ozone column.

Dickinson, R. E.↗

Deep Direct-Use Feasibility Study Temperature-Depth Estimates for West Virginia University, Morgantown, WV

This dataset contains data spreadsheets and figures that summarize the results of a stochastic analysis of temperatures at depth below the West Virginia University campus in Morgantown, WV. These results are extracted from a study by Smith (2019), whose results are included in a GDR submission that provides rasters and shapefiles for the Appalachian Basin states of New York, Pennsylvania, and West Virginia (GDR submission #1182). Uncertainties considered included geologic properties, thermal properties, and uncertainty from geostatistical interpolation of the surface heat flow. A Monte Carlo analysis of these uncertain properties was used to predict temperatures at depth using a 1-D heat conduction model. For the pixel corresponding to West Virginia University, a .csv file containing the 10,000 temperature-depth profiles estimated from a Monte Carlo analysis is provided. Temperatures are provided for depths from 1-5 km in 0.5 km increments. These data are summarized in a figure containing violin plots that illustrates the probability of obtaining certain temperatures at depth for Morgantown.

15 GEOTHERMAL ENERGY↗

Wireless Patch Antenna Characterization for Live Health Monitoring Using Machine Learning

Temperature monitoring in extreme environments, such as coal-fired power plants, was addressed by designing and testing wireless patch antennas for use in machine learning-aided temperature estimation. The sensors were designed to monitor the temperature and health of boiler systems. Wireless interrogation of the sensor was performed using a Vector Network Analyzer (VNA) and a pair of interrogation antennas to capture resonance behavior under varying thermal and spatial conditions with sensitivities ranging from 0.052 to 0.20 $\frac{𝑀𝐻𝑧}{°C}$. Sensor calibration was conducted using a Long Short-Term Memory (LSTM) model, which leveraged temporal patterns to account for hysteresis effects. The calibration method demonstrated improved performance when combined with an LSTM model, achieving up to a 76% improvement in temperature estimation error when compared with Linear Regression (LR). The experiments highlighted an innovative solution for patch antenna-based non-contact temperature measurement, which addresses limitations with conventional methods such as RFID-based systems, infrared, and thermocouples.

20 FOSSIL-FUELED POWER PLANTS↗