Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Occupant Core Temperatures Across the Boston Building Stock to Advance Public Health

In recent history, extreme heat has been the cause of most deaths from a natural disaster. Exposure to extreme heat can aggravate preexisting conditions, increase hospitalization, and even cause death. Thus, modeling the thermal resilience of households across the United States will allow for a quantitative assessment of the health and safety risks posed by extreme heat. For the first time, we simulate occupant comfort in representative households across Boston by combining the granular results of the ResStock(TM) model with a two-node heat strain model. This model calculates occupants' core body temperature in each simulated household over a year. We compare the simulated core temperatures to two public health metrics: hyperthermia and heat stroke. Our results show for households in Boston that do not have or use aid conditioning, thousands potentially experience many dangerous heat events each summer and these events can last for more than a day at a time. These heat events peak during the late afternoon and evening, just as residents are coming home, cooking meals, and trying to go to sleep. We have found that multi-family buildings, renters, and low-income homes in more airtight and insulated homes are the most at risk for these events. These results demonstrate the scale and urgency of exposure to extreme heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Voltage and Temperature Limits of Advanced Electrolytes for Lithium-Metal Batteries

Several advanced electrolytes (mainly ether-based) have recently demonstrated excellent electrochemical performance in high energy density lithium (Li)-metal batteries. However, the safety of these ether-based electrolytes is still unknown. This work evaluates the thermal stability of these new formulations to understand their safety limits of operation in comparison to carbonate electrolytes typically used in Li-ion batteries. Electrolyte stability is assessed in conjunction with LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode and Li-metal anode at ultra-high voltages (≤ 4.8 V) and temperatures (≤ 300°C) to trigger thermal runaway, where onset and extent of heat release are monitored via isothermal microcalorimetry and differential scanning calorimetry Most ether-based electrolytes show improved thermal resilience over commercial carbonate formulations when heated up to 300°C. The thermal behavior in presence of charged cathode and Li-metal suggests that the new electrolytes may be better at stabilizing active material surfaces than carbonate electrolytes. Although extreme voltages severely destabilize the ether-based formulations, prompting thermal runaway, a phosphate based localized high concentration electrolyte exhibits superior stability over commercial carbonate electrolytes at all tested temperatures (32°C, 45°C, and 60°C). Although thermal analysis during the first charge process (as adopted in this preliminary study) may be insufficient to conclude the long-term advantages of these electrolytes, a more stable electrolyte identified under extreme voltage and temperature conditions will provide valuable guidance for the safety of future electrolyte designs.

25 ENERGY STORAGE↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High entropy ceramics for applications in extreme environments

Abstract Compositionally complex materials have demonstrated extraordinary promise for structural robustness in extreme environments. Of these, the most commonly thought of are high entropy alloys, where chemical complexity grants uncommon combinations of hardness, ductility, and thermal resilience. In contrast to these metal–metal bonded systems, the addition of ionic and covalent bonding has led to the discovery of high entropy ceramics (HECs). These materials also possess outstanding structural, thermal, and chemical robustness but with a far greater variety of functional properties which enable access to continuously controllable magnetic, electronic, and optical phenomena. In this experimentally focused perspective, we outline the potential for HECs in functional applications under extreme environments, where intrinsic stability may provide a new path toward inherently hardened device design. Current works on high entropy carbides, actinide bearing ceramics, and high entropy oxides are reviewed in the areas of radiation, high temperature, and corrosion tolerance where the role of local disorder is shown to create pathways toward self-healing and structural robustness. In this context, new strategies for creating future electronic, magnetic, and optical devices to be operated in harsh environments are outlined.

36 MATERIALS SCIENCE↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

Resilient high-temperature reverse osmosis desalination membranes

Conventional thin-film composite (TFC) reverse osmosis (RO) membranes experience irreversible performance loss at high temperatures, restricting their use in industries with high-temperature streams, including oil and gas, pharmaceuticals, electronics, power generation, food production, and hybrid desalination plants. However, the mechanisms driving the performance decline of TFC membranes at high temperatures remain poorly understood. Herein, we combine controlled experiments, molecular dynamics simulations, and micromechanical modeling to elucidate TFC failure mechanisms and to evaluate thermally resilient thin-film cross-linked (TFX) composite membrane. Upon exposure to elevated temperatures (>60°C), salt rejection of TFC dropped from ~99 to <90%, with irreversible structural damage in the polysulfone layer, confirmed by scanning electron microscopy. In contrast, the TFX membrane maintained ~99% salt rejection and showed no signs of physical degradation up to 80°C. Our combined analyses revealed that TFC membrane failure arises from irreversible pore expansion in the thermoplastic polysulfone support, leading to polyamide film rupture and delamination. TFX membranes resist thermal deformation, enabling ultrahigh-temperature RO desalination and water reuse.

Wu, Jishan [Rice Univ., Houston, TX (United States↗

ALD-Derived WO 3– x Leads to Nearly Wake-Up-Free Ferroelectric Hf 0.5 Zr 0.5 O 2 at Elevated Temperatures

Breaking the memory wall in advanced computing architectures will require complex 3D integration of emerging memory materials such as ferroelectrics─either within the back-end-of-line (BEOL) of CMOS front-end processes or through advanced 3D packaging technologies. Achieving this integration demands that memory materials exhibit high thermal resilience, with the capability to operate reliably at elevated temperatures, such as 125°C, due to the substantial heat generated by front-end transistors. However, silicon-compatible HfO 2 -based ferroelectrics tend to exhibit antiferroelectric-like behavior in this temperature range, accompanied by a more pronounced wake-up effect, posing significant challenges to their thermal reliability. Here, we report that by introducing a thin tungsten oxide (WO 3–x ) layer─known as an oxygen reservoir─and carefully tuning its oxygen content, ultrathin Hf 0.5 Zr 0.5 O 2 (5 nm) films can be made robust against the ferroelectric-to-antiferroelectric transition at elevated temperatures. This approach not only minimizes polarization loss in the pristine state but also effectively suppresses the wake-up effect, reducing the required wake-up cycles from 10 5 to only 10 at 125°C, a qualifying temperature for back-end memory integrated with front-end logic, as defined by the JEDEC standard. First-principles density functional theory (DFT) calculations reveal that WO 3 enhances the stability of the ferroelectric orthorhombic phase (o-phase) at elevated temperatures by increasing the tetragonal-to-orthorhombic phase energy gap and promoting favorable phonon mode evolution, thereby supporting o-phase formation under both thermodynamic and kinetic constraints.

36 MATERIALS SCIENCE↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A digital twin platform for building performance monitoring and optimization: Performance simulation and case studies

Advancements in sensor technology, data analytics, affordable compute, and communication infrastructure have paved the way for Digital Twin technology in optimizing building operations and controls. This study presents the development of an open and interoperable web-based Digital Twin platform for integrating diverse data streams and facilitating effective user interactions. The platform utilizes modern technologies for the web framework and time-series data management, ensuring scalability and responsiveness. The backend supports seamless integration of diverse data sources and emulators, incorporating data from building sensors and meters, external weather Application Programming Interfaces, and advanced EnergyPlus simulation models of the building and its energy systems including the Distributed Energy Resources that are formulated in Functional Mockup Units. A simulation case study was conducted with FlexLab, a test facility on Lawrence Berkeley National Laboratory campus. The case study includes normal operations, Distributed Energy Resource integration, and power outage scenarios, to illustrate the Digital Twin’s ability to provide critical insights into energy performance and thermal resilience. The results demonstrated the platform’s potential as a decision-support tool for optimizing building energy performance and enhancing resilience against extreme weather events. Future work will focus on deploying the Digital Twin platform to a real building for field validation, extending its capabilities to cover more scenarios such as bidirectional Electric Vehicle interactions, and enhancing user engagement.

EnergyPlus↗

Structure-property relationships and recyclability of natural fiber insulation

Thermal insulation can significantly decrease the energy required to maintain internal temperatures within buildings, saving money and decreasing environmental impacts. Many industrially available insulation options utilize petroleum-derived materials, such as polyurethane, fiberglass, and polystyrene, which can be detrimental to the environment by emitting greenhouse gases during production. A sustainable alternative to these synthetic insulations is the use of renewable feedstocks to produce comparable insulation products. In this work, natural fibers such as flax and banana were bound with an epoxy system to produce natural-fiber insulation. Key experimental parameters for this study included evaluating the fiber lengths and processing methods while varying the viscosity of the epoxy binder solvent dissolution. Insulation performance was determined by comparing density, thermal conductivity, resilience, and compressive strength; these parameters were tested to further understand and investigate the structure- property relationships within the system and to understand how these composites compare to current commercial materials. Furthermore, from this characterization and optimization, a natural fiber sample with an R/in. >5 was achieved, making these materials competitive with commercial alternatives.

Compressive strength↗

Interfacial Hydrogen-Bond Dynamics in Transition Metal Compounds

Understanding how water behaves when confined within atomic layers of active transition-metal carbides, nitrides, and carbonitrides is essential for uncovering the fundamental principles needed to engineer solid–liquid interfaces at the atomic scale. Yet, how lattice element chemistry and surface termination groups collectively regulate the structure and mobility of such interlayer water remains poorly understood. Here, we present a composition-controlled investigation of interlayer water dynamics in layered transition-metal nitride, carbide, and carbonitride systems using a systematic integration of quasi-elastic neutron scattering (QENS), ab initio molecular dynamics (AIMD) simulations, and density functional theory (DFT) calculations. QENS measurements show that nitride-rich systems host mobile, translationally diffusing water with thermally activated self-diffusion coefficients on the order of 10 –10 m 2 s –1 , whereas mixed C/N lattices confine water to localized, nontranslational motion that is insensitive to temperature. AIMD and DFT reveal that lattice C/N chemistry and surface functional group composition reshape the first hydration layer by modulating the surface electronic structure and termination-dependent hydrogen-bond networks, leading to pronounced differences in water ordering and thermal resilience. On the other hand, fully carbide systems exhibit intermediate behavior, highlighting that water mobility is not primarily controlled by the hydration level alone but by the coupling between lattice composition and surface chemistry. Overall, this study establishes how surface chemistry and lattice composition jointly control interfacial hydrogen bond dynamics, offering a mechanistic framework for designing transition-metal layered materials with tailored interfacial transport properties.

Hydration↗

Machine learning-accelerated discovery of heat-resistant polysulfates for electrostatic energy storage

The development of heat-resistant dielectric polymers that withstand intense electric fields at high temperatures is critical for electrification. Balancing thermal stability and electrical insulation, however, is exceptionally challenging as these properties are often inversely correlated. A traditional intuition-driven polymer design approach results in a slow discovery loop that limits breakthroughs. Here we present a machine learning-driven strategy to rapidly identify high-performance, heat-resistant polymers. A trustworthy feed-forward neural network is trained to predict key proxy parameters and down select polymer candidates from a library of nearly 50,000 polysulfates. The highly efficient and modular sulfur fluoride exchange click chemistry enables successful synthesis and validation of selected candidates. A polysulfate featuring a 9,9-di(naphthalene)-fluorene repeat unit exhibits excellent thermal resilience and achieves ultrahigh discharged energy density with over 90% efficiency at 200 °C. Its exceptional cycling stability underscores its promise for applications in demanding electrified environments.

Li, He↗

Enhanced resistance to decay of imprinted nanopatterns in thin films by bare nanoparticles compared to polymer-grafted nanoparticles

We extend a previous study on the influence of nanoparticles on the decay of nanoimprinted polymer film patterns to compare the effects of “bare” silica (SiO 2 ) nanoparticles and SiO 2 nanoparticles with grafted polymer layers having the same chemical composition as the polymer matrix. This method involves nanoimprinting substrate-supported polymer films using a pattern replicated from a digital versatile disc (DVD), and then annealing the patterned polymer nanocomposite films at elevated temperatures to follow the decay of the topographic surface pattern with time by atomic force microscopy imaging after quenching. We quantified the relaxation of the pattern height (“slumping”) and determined the relaxation time τ for this pattern decay process as a function of nanoparticle filler type and concentration to determine how nanoparticle additives influence relative film stability. Attractive interactions between the bare nanoparticles and the polymer matrix significantly enhance the thermal resilience of the nanopatterns to decay, compared to those of the particle brushes, wherein the particle core interactions are screened from the matrix via the brush layer. A novel aspect of this method is that it readily lends itself to in situ film relaxation measurements in a manufacturing context. We observe that the relaxation time of the pattern relaxation exhibits entropy–enthalpy compensation in the free energy parameters governing the pattern relaxation process as a function of temperature, irrespective of the NP system used, consistent with our previous experimental and computational studies.

36 MATERIALS SCIENCE↗

Superconducting Qubits above 20 GHz Operating over 200 mK

Current state-of-the-art superconducting microwave qubits are cooled to extremely low temperatures to avoid sources of decoherence. Higher qubit operating temperatures would significantly increase the cooling power available, which is desirable for scaling up the number of qubits in quantum computing architectures and integrating qubits in experiments requiring increased heat dissipation. To operate superconducting qubits at higher temperatures, it is necessary to address both quasiparticle decoherence (which becomes significant for aluminum junctions above 160 mK) and dephasing from thermal microwave photons (which are problematic above 50 mK). Using low-loss niobium-trilayer junctions, which have reduced sensitivity to quasiparticles due to the higher superconducting transition temperature of niobium, we fabricate transmons with higher frequencies than previously studied, up to 24 GHz. We measure decoherence and dephasing times of about 1 μs, corresponding to average qubit quality factors of approximately 10 5 , and find that decoherence is unaffected by quasiparticles up to 1 K. Without relaxation from quasiparticles, we are able to explore dephasing from purely thermal sources, finding that our qubits can operate up to approximately 250 mK while maintaining similar performance. The thermal resilience of these qubits creates new options for scaling up quantum processors, enables hybrid quantum experiments with high heat-dissipation budgets, and introduces a material platform for even-higher-frequency qubits.

Josephson junctions↗

Capacitor Design for Self-Resonant Coils for Long-Distance Wireless Power Transfer System

In this paper, an integrated capacitor design is proposed for higher-order resonant tank topologies for self-resonant coils, such as series, parallel, LCC, LLC, etc. The capacitor is one of the large, lossy, and thermally vulnerable components of a high-frequency resonant tank, and designing a high-voltage, thermally stable resonant capacitor can be highly challenging. Designing the extremely high-voltage capacitor as an integral part of the coil reduces the size and complexity of the coil assembly. This paper proposes a low-loss PCB-based high-voltage capacitor design to achieve that target, which can be implemented as an integral part of the coil. The proposed capacitor designs are simulated using Multiphysics FEA and tested experimentally. A 23 kV, 133 pF capacitor prototype was built and tested as part of a 1 kW long-distance wireless charging system. The test results verify the capacitor’s voltage, current, and thermal resiliency performance.

Mohammad, Mostak [ORNL] (ORCID:0000000256388783)↗