Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trapped Ion Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Apodization Specific Fitting for Improved Resolution, Charge Measurement, and Data Analysis Speed in Charge Detection Mass Spectrometry

Short-time Fourier transforms with short segment lengths are typically used to analyze single ion charge detection mass spectrometry (CDMS) data either to overcome effects of frequency shifts that may occur during the trapping period or to more precisely determine the time at which an ion changes mass or charge, or enters an unstable orbit. The short segment lengths can lead to scalloping loss unless a large number of zero-fills are used, making computational time a significant factor in real-time analysis of data. Apodization specific fitting leads to a 9-fold reduction in computation time compared to zero-filling to a similar extent of accuracy. This makes possible real-time data analysis using a standard desktop computer. Rectangular apodization leads to higher resolution than the more commonly used Gaussian or Hann apodization and makes it possible to separate ions with similar frequencies, a significant advantage for experiments in which the masses of many individual ions are measured simultaneously. Equally important is a >20% increase in S/N obtained with rectangular apodization compared to Gaussian or Hann, which directly translates to a corresponding improvement in accuracy of both charge measurements and ion energy measurements that rely on the amplitudes of the fundamental and harmonic frequencies. Finally, combined with computing the fast Fourier transform in a lower-level language, this fitting procedure eliminates computational barriers and should enable real-time processing of CDMS data on a laptop computer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-line installation of the Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap

The Cabibbo-Kobayashi-Maskawa quark mixing matrix currently does not satisfy unitarity at the 2σ-level. This could be the result of an inaccurate value of one or both of its largest matrix elements V us and V ud . In the case of V ud , the most precise measurement is obtained from the f t -value measurements of superallowed beta-transitions between 0 + states. The accuracy of this determination can, in turn, be tested by extracting V ud in other transitions including superallowed transitions between mirror nuclei. The Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) is currently under construction at the Nuclear Science Laboratory of the University of Notre Dame to perform such a determination, with the goal of shedding more light on this tension with unitarity. St. Benedict will take a radioactive ion beam produced by TwinSol , thermalize it in a large volume gas catcher, then transport it in two separate differentially-pumped volumes using a radio-frequency (RF) carpet and a radio-frequency quadrupole (RFQ) ion guide before injecting it in an RFQ trap to create cool ion bunches for injection in the measurement Paul trap. In this paper, we detail the installation of the beam preparation components of St. Benedict, and present the results of the first RIBs successfully stopped and extracted from its gas catcher.

Brodeur, M.↗

Implementing a Laser Stabilization System for Trapping Ca+ Ions: an Internship Reflection

At Lawrence Livermore National Laboratory, I contributed to a project developing 3D printed micro ion traps for quantum computing. I designed, implemented, and assessed a laser stabilization system that locked lasers to the frequencies required for calibrating our High Finesse WS8-10 wavelength meter and for laser cooling and trapping of Ca+ ions. I also programmed a Python interface for hardware communication, data collection, and statistical analysis. Additionally, I optimized and aligned laser beam paths, and I implemented a closed digital feedback loop using Proportional, Integral, and Derivative (PID) control parameters. I analyzed both the long-term and short-term behavior of our locked lasers and adjusted PID parameters to enhance performance. Furthermore, I used COMSOL to simulate the capacitance of a linear Paul trap design and predict our trap’s performance. The procedures I developed for the interface, analysis, and simulations will continue to support the ion trapping experiment after my appointment. I strengthened my skills in data analysis, Python coding, and optical alignment for laser systems. My confidence as a researcher grew, particularly in communicating my research. This experience taught me the importance of careful planning and consideration in research and solidified my desire to continue exploring novel quantum technology as an undergraduate

42 ENGINEERING↗

High-fidelity trapped-ion qubit operations with scalable photonic modulators

Abstract Experiments with trapped ions and neutral atoms typically employ optical modulators in order to control the phase, frequency, and amplitude of light directed to individual atoms. These elements are expensive, bulky, consume substantial power, and often rely on free-space I/O channels, all of which pose scaling challenges. To support many-ion systems like trapped-ion quantum computers or miniaturized deployable devices like clocks and sensors, these elements must ultimately be microfabricated, ideally monolithically with the trap to avoid losses associated with optical coupling between physically separate components. In this work we design, fabricate, and test an optical modulator capable of monolithic integration with a surface-electrode ion trap. These devices consist of piezo-optomechanical photonic integrated circuits configured as multi-stage Mach-Zehnder modulators that are used to control the intensity of light delivered to a single trapped ion on a separate chip. We use quantum tomography employing hundreds of multi-gate sequences to enhance the sensitivity of the fidelity to the types and magnitudes of gate errors relevant to quantum computing and better characterize the performance of the modulators, ultimately measuring single qubit gate fidelities that exceed 99.7%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

One- and two-qubit gate infidelities due to motional errors in trapped ions and electrons

In this work, we derive analytic formulas that determine the effect of error mechanisms on one- and two-qubit gates in trapped ions and electrons. First, we analyze and derive expressions for the effect of driving field inhomogeneities on one-qubit gate fidelities. Second, we derive expressions for two-qubit gate errors, including static motional frequency shifts, trap anharmonicities, field inhomogeneities, heating, and motional dephasing. We show that, for small errors, each of our expressions for infidelity converges to its respective numerical simulation; this shows that our formulas are sufficient for determining error budgets for high-fidelity gates, obviating numerical simulations in future projects. All of the derivations are general to any internal qubit state, and any mixed state of the ion crystal's motion that is diagonal in the Fock state basis. Our treatment of static motional frequency shifts, trap anharmonicities, heating, and motional dephasing apply to both laser-based and laser-free gates, while our treatment of field inhomogeneities applies to laser-free systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Off-line commissioning of the St. Benedict radiofrequency quadrupole cooler-buncher

The St. Benedict ion trapping system, which aims to measure the β - v angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the V ud element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width at its exit. The commissioning results also determined the trapping efficiency to be 93(1)% and the trapping half-life to be 20.0(5) s.

Paul trap↗

Mapping the Temperature-dependent and network site-specific onset of spectral diffusion at the surface of a water cluster cage

We explore the kinetic processes that sustain equilibrium in a microscopic, finite system. This is accomplished by monitoring the spontaneous, time-dependent frequency evolution (the frequency autocorrelation) of a single OH oscillator, embedded in a water cluster held in a temperature-controlled ion trap. The measurements are carried out by applying two-color, IR-IR photodissociation mass spectrometry to the D3O+?(HDO)(D2O)19 isotopologue of the “magic number” protonated water cluster, H+?(H2O)21. The OH group can occupy any one of the five spectroscopically distinct sites in the distorted pentagonal dodecahedron cage structure. The OH frequency is observed to evolve over tens of milliseconds in the temperature range (90-120 K). Starting at 100 K, large “jumps” are observed between two OH frequencies separated by ~300 cm-1 indicating migration of the OH group from the bound OH site at 3350 cm-1 to the free position at 3686 cm-1. Increasing the temperature to 110 K leads to partial interconversion among many sites. All sites are observed to interconvert at 120 K such that the distribution of the unique OH group among them adopts the form one would expect for a canonical ensemble. The spectral dynamics displayed by the clusters thus offer an unprecedented view into the molecular-level processes that drive spectral diffusion in an extended network of water molecules.

Yang, Nan↗

Design and fabrication of ion traps for low RF power dissipation

Large surface-electrode ion traps with multiple trapping regions and junctions are a natural approach to scaling trapped ion quantum computers, supporting the connectivity and ion counts necessary for complex quantum algorithms. However, a major hurdle in this scaling is on-chip power dissipation from the applied RF voltage, which increases at a rate between linear and cubic relative to trap size, depending on whether the losses are dielectric or Ohmic. Here, we present two versions of a trap with features designed to reduce both types of RF power dissipation. The first variant contains a raised RF electrode that increases the electrode–ground distance to reduce capacitance. Different DC voltage sources are demonstrated on this trap to show that technical noise before the filter remains the dominant source of voltage noise and therefore motional heating. The second variant additionally includes a method for removing dielectric from beneath the RF electrode to further reduce dielectric losses. These traps were demonstrated at room temperature with 40 Ca + ions. In conclusion, the similar heating rates and heating rate axial frequency dependencies between 2.4 and 3.0 MHz illustrate that this dielectric modification is not detrimental to trap performance.

Sterk, J. D. [Sandia National Laboratories (SNL-NM↗

Tandem Mass-Selective Cryogenic Digital Ion Traps for Enhanced Cluster Formation

We present the implementation of tandem mass-selective cryogenic ion traps, designed to enhance the range of ion processing capabilities that can be performed prior to spectroscopic interrogation. We show that both the formation of ion clusters and mass filtering steps can be combined in a single cryogenic linear quadrupole ion trap driven by RF square waves. Mass filtering and mass isolation can be achieved by manipulation of the RF frequency and duty cycle. Very importantly, this scheme circumvents the need for high-amplitude RF voltages that can be incompatible with typical cryogenic ion processing conditions. In addition, proper adjustment of the stability boundaries during the clustering process allows for the preferential formation of a specific cluster size rather than a broad distribution of sizes. Lastly, we show that a specific cluster size can be formed, mass-selected, and then transferred to another ion trap for a second completely separate ion processing step. Furthermore, the instrumentation and modular design developed here expand the scope of ionic species and clusters that can be accessed by processing electrosprayed ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cold ion beam in a storage ring as a platform for large-scale quantum computers and simulators: Challenges and directions for research and development

The purpose of this paper is to evaluate the possibility of constructing a large-scale storage-ring-type ion-trap system capable of storing, cooling, and controlling a large number of ions as a platform for scalable quantum computing (QC) and quantum simulations. In such a trap, the ions form a crystalline beam moving along a circular path with a constant velocity determined by the frequency and intensity of the cooling lasers. In this paper, we consider a large leap forward in terms of the number of ions that serve as qubits in QC, from fewer than 100 available in state of the art linear ion-trap devices today to an order of 10 5 crystallized ions in the storage-ring setup. This new trap design unifies two different concepts: the storage rings of charged particles and the linear ion traps used for QC and mass spectrometry. In this paper, we use the language of particle accelerators to discuss the ion state and dynamics. We outline the differences between the above concepts, analyze challenges of the large ring with a revolving chain of ions, and propose goals for the research and development required to enable future quantum computers with 1000 times more qubits than available today. The challenge of creating such a large-scale quantum system while maintaining the necessary coherence of the qubits and the high fidelity of quantum logic operations is significant. Performing analog quantum simulations may be an achievable initial goal for such a device. Quantum calculations and simulations of complex quantum systems will move forward both the fundamental science and the applied research. Nuclear and particle physics, many-body quantum systems, lattice gauge theories, and nuclear structure calculations are just a few examples in which a large-scale quantum simulation system will become a very powerful tool to move forward our understanding of nature.

36 MATERIALS SCIENCE↗

Single-ion addressing via trap potential modulation in global optical fields

To date, individual addressing of ion qubits has relied primarily on local Rabi or transition frequency differences between ions created via electromagnetic field spatial gradients or via ion transport operations. Alternatively, it is possible to synthesize arbitrary local one-qubit gates by leveraging local phase differences in a global driving field. Here we report individual addressing of 40 Ca + ions in a two-ion crystal using axial potential modulation in a global gate laser field. We characterize the resulting gate performance via one-qubit randomized benchmarking, applying different random sequences to each co-trapped ion. We identify the primary error sources and compare the results with single-ion experiments to better understand our experimental limitations. These experiments form a foundation for the universal control of two ions, confined in the same potential well, with a single gate laser beam.

quantum computing↗

Electrostatic turbulence in EAST plasmas with internal transport barrier

Based on first-principles nonlinear gyrokinetic simulations, the electrostatic turbulence properties in the internal transport barrier (ITB) region of an Experimental Advanced Superconducting Tokamak discharge (#93890) are investigated. Specifically, ITBs with steep density and temperature gradients are located in the weakly negative magnetic shear region at the plasma center. In the linear stage, the growth rate and frequency of the ion temperature gradient (ITG) mode increase significantly due to resonant excitation by trapped electrons. That is, the resonance between trapped electrons and the ITG becomes strong due to the precession drift reversal of trapped electrons by the negative magnetic shear and Shafranov shift. Meanwhile, the trapped electron mode is stable in the ITB region due to only a very small fraction of electrons precessing in the direction of the electron diamagnetic drift. Nonlinear simulations show that, after considering the non-adiabatic effect of trapped electrons, the heat conductivity of ions and the turbulence intensity increase by at least a factor of 7 compared with the results only considering the adiabatic effect of electrons. The zonal charge density of trapped electrons can partially cancel that of ions, which weakens the intensity of the zonal flow, and consequently reduces the zonal flow regulation and enhances the turbulent transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adiabatic cooling of planar motion in a Penning-trap ion crystal to sub-millikelvin temperatures

Two-dimensional planar ion crystals in a Penning trap are a platform for quantum information science experiments. However, the low-frequency planar modes of these crystals are not efficiently cooled by laser cooling, which can limit the utility of the drumhead modes for quantum information processing. Recently, it has been shown that nonlinear mode coupling can enhance the cooling of the low-frequency planar modes. Here, in this study, we demonstrate in numerical simulations that this coupling can be dynamically tuned by adiabatically changing the rotation frequency of the ion crystal during experiments. Furthermore, we show that this technique can, in addition, produce lower temperatures for the low-frequency planar modes via an adiabatic cooling process. This result allows cooling of the planar modes to sub-millikelvin temperatures, resulting in improved spectral resolution of the drumhead modes at experimentally relevant rotation frequencies, which is crucial for quantum information processing applications.

Johnson, Wes [Univ. of Colorado, Boulder, CO (Unit↗

Large-scale simulations of Floquet physics on near-term quantum computers

Abstract Periodically driven quantum systems exhibit a diverse set of phenomena but are more challenging to simulate than their equilibrium counterparts. Here, we introduce the Quantum High-Frequency Floquet Simulation (QHiFFS) algorithm as a method to simulate fast-driven quantum systems on quantum hardware. Central to QHiFFS is the concept of a kick operator which transforms the system into a basis where the dynamics is governed by a time-independent effective Hamiltonian. This allows prior methods for time-independent simulation to be lifted to simulate Floquet systems. We use the periodically driven biaxial next-nearest neighbor Ising (BNNNI) model, a natural test bed for quantum frustrated magnetism and criticality, as a case study to illustrate our algorithm. We implemented a 20-qubit simulation of the driven two-dimensional BNNNI model on Quantinuum’s trapped ion quantum computer. Our error analysis shows that QHiFFS exhibits not only a cubic advantage in driving frequency ω but also a linear advantage in simulation time t compared to Trotterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward improved quantum simulations and sensing with trapped two-dimensional ion crystals via parametric amplification

Improving coherence is a fundamental challenge in quantum simulation and sensing experiments with trapped ions. Here we discuss, experimentally demonstrate, and estimate the potential impacts of two different protocols that enhance, through motional parametric excitation, the coherent spin-motion coupling of ions obtained with a spin-dependent force. The experiments are performed on two-dimensional crystal arrays of approximately 100 9 ⁢Be + ions confined in a Penning trap. By modulating the trapping potential at close to twice the center-of-mass mode frequency, we squeeze the motional mode and enhance the spin-motion coupling while maintaining spin coherence. With a stroboscopic protocol, we measure 5.4 ± 0.9 dB of motional squeezing below the ground-state motion, from which theory predicts a 10-dB enhancement in the sensitivity for measuring small displacements using a recently demonstrated protocol [K. A. Gilmore et al., Science 373, 673 (2021)]. With a continuous squeezing protocol, we measure and accurately calibrate the parametric coupling strength. Theory suggests this protocol can be used to improve quantum spin squeezing, limited in our system by off-resonant light scatter. Finally, we illustrate numerically the trade-offs between strong parametric amplification and motional dephasing in the form of center-of-mass frequency fluctuations for improving quantum spin squeezing in our setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Changes in electric field noise due to thermal transformation of a surface ion trap

Here, we aim to illuminate how the microscopic properties of a metal surface map to its electric field noise characteristics. In our system, prolonged heat treatments of a metal film can induce a rise in the magnitude of the electric field noise generated by the surface of that film. We refer to this heat-induced rise in noise magnitude as a thermal transformation. The underlying physics of this thermal transformation process is explored through a series of heating, milling, and electron treatments performed on a single surface ion trap. Between these treatments, 40 Ca + ions trapped 70 μm above the surface of the metal are used as detectors to monitor the electric field noise at frequencies close to 1 MHz. An Auger spectrometer is used to track changes in the composition of the contaminated metal surface. With these tools we investigate contaminant deposition, chemical reactions, and atomic restructuring as possible drivers of thermal transformations.

36 MATERIALS SCIENCE↗

Closed-loop optimization of fast trapped-ion shuttling with sub-quanta excitation

Shuttling ions at high speed and with low motional excitation is essential for realizing fast and high-fidelity algorithms in many trapped-ion-based quantum computing architectures. Achieving such performance is challenging due to the sensitivity of an ion to electric fields and the unknown and imperfect environmental and control variables that create them. Here we implement a closed-loop optimization of the voltage waveforms that control the trajectory and axial frequency of an ion during transport in order to minimize the final motional excitation. The resulting waveforms realize fast round-trip transport of a trapped ion across multiple electrodes at speeds of 0.5 electrodes per microsecond (35 m∙s -1 for a one-way transport of 210 μm in 6 s) with a maximum of 0.36 ± 0.08 mean quanta gain. This sub-quanta gain is independent of the phase of the secular motion at the distal location, obviating the need for an electric field impulse or time delay to eliminate the coherent motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling noise in global Mølmer-Sørensen interactions applied to quantum approximate optimization

Many-qubit Mølmer-Sørensen (MS) interactions applied to trapped ions offer unique capabilities for quantum information processing, with applications including quantum simulation and the quantum approximate optimization algorithm (QAOA). Here, we develop a physical model to describe many-qubit MS interactions under four sources of experimental noise: vibrational mode frequency fluctuations, laser power fluctuations, thermal initial vibrational states, and state preparation and measurement errors. The model parametrizes these errors from simple experimental measurements, without free parameters. Herein, we validate the model in comparison with experiments that implement sequences of MS interactions on two 171 Yb + ions. The model shows reasonable agreement after several MS interactions as quantified by the reduced chi-squared statistic $χ^{2}_{red}$≈2. As an application we examine MaxCut QAOA experiments on three and six ions. The experimental performance is quantified by approximation ratios that are 91% and 83% of the optimal theoretical values. Our model predicts $0.93^{+0.03}_{-0.02}$ and $0.95^{+0.04}_{-0.03}$, respectively, with disagreement in the latter value attributable to secondary noise sources beyond those considered in our analysis. With realistic experimental improvements to reduce measurement error and radial trap frequency variations, the model achieves approximation ratios that are 99% of the optimal. Incorporating these improvements into future experiments is expected to reveal new aspects of noise for future modeling and experimental improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗