Technical basis for the use of a correlated neutron source in the uranium neutron coincidence collar

Active neutron coincidence systems are commonly used by international inspectorates to verify a material balance across the various stages of the nuclear fuel cycle. The Uranium Neutron Coincidence Collar (UNCL) is one such instrument; it is used to measure the linear density of 235 U (g 235 U/cm of active length in assembly) in fresh light water reactor fuel in nuclear fuel fabrication facilities. The UNCL and other active neutron interrogation detectors have historically relied on americium lithium ( 241 AmLi) sources to induce fission within the sample in question. Californium-252 is under consideration as a possible alternative to the traditional 241 AmLi source. Finally, this work relied upon a combination of experiments and Monte Carlo simulations to demonstrate the technical basis for the replacement of 241 AmLi sources with 252 Cf sources by evaluating the statistical uncertainty in the measurements incurred by each source and assessing the penetrability of neutrons from each source for the UNCL.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Fast Neutron Passive Collar Optimization Report

The UNCL has been used for over thirty years for the verification of the 235 U content of LWR nuclear fuel.The most recent version of the detector, the UNCL-II, consists of four HDPE blocks, three containing 3He proportional counters and a fourth containing a slot for an AmLi source. [1] The 3He proportional counters have a nominal active length of 33 cm, a diameter of 2.54 cm and a gas pressure of 4 atm. The UNCL-II has cavity dimensions 41.4 x 23.4 x 23.4 cm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modernizing the active neutron collar poison rod correction using simulations to enhance PWR fresh fuel verification

The declared inventory of 235 U in fresh, low enriched uranium, nuclear fuel assemblies is routinely verified by nuclear safeguards inspectorates using the UNCL (Uranium Neutron Collar – Light Water Reactor Fuel) nondestructive assay instrument. The trend in modern fuels is towards higher initial enrichment, which in turn requires a larger number of burnable poison pins with higher Gadolinia concentration to hold down the initial reactivity. UNCL assay error for modern fuel assemblies typically exceeds 10%. The traditional algorithm used to correct the response for burnable poison content needs revision to achieve accuracy comparable to the $\sigma_\text{R}$ of 4.5% expected for poison-free assemblies. Here we review the problem and use a large set of 287 Monte Carlo simulations based on an experimentally benchmarked model corresponding to the 16×16 PWR array used in Brazilian Angra type II and III fuel. Simulated relative responses are used to evaluate the functional form of the poison correction and determine parameters optimal for 16×16 PWR assemblies. This update is conducted using between 4–24 Gadolinia pins ranging 2–11 wt% Gd 2 O 3 with assemblies having mean enrichments ranging 2.5%–5%. Experimental validation of the updated coefficients using seven measurements shows bias is reduced by an order of magnitude and $\sigma_\text{R}$R reduced from 10% to less than 2%. Two updated sets of coefficients are provided, the most accurate of which is directly useable in the existing analysis code (INCC) in use by inspectorate at fuel fabrication facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Well Counting Using New PSD Plastic Detectors

This report presents results and analysis from a series of proof-of-concept measurements to assess the suitability of segmented detectors constructed from Eljen EJ-299-34 PSD-plastic scintillator with pulse-shape discrimination capability for the purposes of quantifying uranium via active neutron coincidence counting. Present quantification of bulk uranium materials for international safeguards and domestic materials control and accounting relies on active neutron coincidence counting systems, such as the Active Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL), that use moderated He-3 proportional counters along with necessarily low-intensity 241Am(Li) neutron sources. Scintillation-based fast-neutron detectors are a potentially superior technology to the existing AWCC and UNCL designs due to their spectroscopic capability and their inherently short neutron coincidence times that largely eliminate random coincidences and enable interrogation by stronger sources. One of the past impediments to the investigation and adoption of scintillation counters for the purpose of quantifying bulk uranium was the commercial availability of scintillators having the necessary neutron-gamma pulse-shape discrimination properties only as flammable liquids. Recently, Eljen EJ-299-34 PSD-plastic scintillator became commercially available. The present work is the first assessment of an array of PSD-plastic detectors for the purposes of quantifying bulk uranium. The detector panel used in the present work was originally built as the focal plane for a fast-neutron imager, but it was repurposed for the present investigation by construction of a stand to support the inner well of an AWCC immediately in front of the detector panel. The detector panel and data acquisition of this system are particularly well suited for performing active-well fast-neutron counting of LEU and HEU samples because the active detector volume is solid, the 241Am(Li) interrogating neutrons are largely below the detector threshold, and the segmented construction of the detector modules allow for separation of true neutron-neutron coincidences from inter-detector scattering using the kinematics of neutron scattering. The results from a series of measurements of a suite of uranium standards are presented, and compared to measurements of the same standards and source configurations using the AWCC. Using these results, the performance of the segmented detectors reconfigured as a well counter is predicted and outperforms the AWCC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improvements in Boron Plate Coating Technology for Higher Efficiency Neutron Detection and Coincidence Counting Error Reduction

This informal report presents the measurement data and information to document the performance of the advanced Precision Data Technology, Inc. (PDT) sealed cell boron-10 plate neutron detector that makes use of the advanced coating materials and procedures. In 2015, PDT changed the boron coating materials and application procedures to significantly increase the efficiency of their basic corrugated plate detector performance. A prototype sealed cell unit was supplied to LANL for testing and comparison with prior detector cells. Also, LANL had reference detector slabs from the original neutron collar (UNCL) and the new Antech UNCL with the removable 3He tubes. The comparison data is presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating the AmLi Neutron Spectrum from Measured Ring Ratios

These are a set of slides on estimating the AmLi neutron spectrum from measured ring ratios. The IAEA uses an AmLi source in the Uranium Neutron Coincidence Collar (UNCL) to verify compliance with nonproliferation treaties. The UNCL requires calibration with known uranium samples. The AmLi spectrum isn’t known well enough to allow simulated calibrations. Alphas lose energy traveling through AmO 2 particle of unknown size. Energy reduction below Li threshold enhances O contribution. Unknown Li matrix material affects neutron production and thermalization. There is large variation in spectra from each element. Other topics covered include: applications, physics considerations, current spectra, measurement overview, measurement results - variation between sources, simulations, spectra fitting, other simulations, and conclusions.

07 ISOTOPE AND RADIATION SOURCES↗

Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement

The objective of this project was to design and optimize, in simulation space, an active neutron coincidence counter (or collar) using boron-coated straws (BCSs) as a non- 3 He replacement to the Uranium Neutron Coincidence Collar (UNCL). UNCL has been used by the International Atomic Energy Agency (IAEA) and European Atomic Energy Community (Euratom) since the 1980s to verify the 235 U content in fresh light water reactor fuel assemblies for safeguards purposes. This report documents the design and optimization of the BCS collar.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The D-D Neutron Generator as an Alternative to Am(Li) Isotopic Neutron Source in the Active Well Coincidence Counter

The 235 U mass assay of bulk uranium items, such as oxide canisters, fuel pellets, and fuel assemblies, is not achievable by traditional gamma-ray assay techniques due to the limited penetration of the item by the characteristic 235 U gamma rays. Instead, fast neutron interrogation methods such as active neutron coincidence counting must be used. For international safeguards applications, the most commonly used active neutron systems, the Active Well Coincidence Counter (AWCC), Uranium Neutron Collar (UNCL) and 252 Cf Shuffler, rely on fast neutron interrogation using an isotopic neutron source [i.e., 252 Cf or Am(Li)] to achieve better measurement accuracies than are possible using gamma-ray techniques for high-mass, high-density items. However, the Am(Li) sources required for the AWCC and UNCL systems are no longer manufactured, and newly produced systems rely on limited supplies of sources salvaged from disused instruments. The 252 Cf shuffler systems rely on the use of high-output 252 Cf sources, which while still available have become extremely costly for use in routine operations and require replacement every five to seven years. Lack of a suitable alternative neutron interrogation source would leave a potentially significant gap in the safeguarding of uranium processing facilities. In this work, we made use of Oak Ridge National Laboratory’s (ORNL’s) Large Volume Active Well Coincidence Counter (LV-AWCC) and a commercially available deuterium-deuterium (D-D) neutron generator to examine the potential of the D-D neutron generator as an alternative to the isotopic sources. We present the performance of the LV-AWCC with D-D generator for the assay of 235 U based on the results of Monte Carlo N-Particle (MCNP) simulations and measurements of depleted uranium (DU), low enriched uranium (LEU), and highly enriched uranium (HEU) items.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Management of Digital Equipment in Preproduction by Means of Uniform Numeric Control Language

The requirements on preproduction and the control software for various digital machining systems (numerically controlled machine tools, robot manipulators, additive manufacturing equipment) in flexible production are considered. By analysis of existing programming languages for digital equipment, UNCL (Uniform Numeric Control Language) has been developed for standard representation of control commands. The use of UNCL in verifying program operation on a machining simulator is considered. Software for the translation of control programs (specified in CLDATA formats and in ISO code) to the invariant format of the universal language is described. The postprocessing of control software from the universal language into programs in commonly used digital control systems is also considered.

42 ENGINEERING↗

Development of Integrated Online Monitoring Systems for Detection of Diversion at Natural Uranium Conversion Facilities

Recent work at Oak Ridge National Laboratory (ORNL) has focused on some source term modeling of uranyl nitrate (UN) as part of a comprehensive validation effort employing gamma-ray detector instrumentation for the detection of diversion from declared conversion activities. Conversion, the process by which natural uranium ore (yellowcake) is purified and converted through a series of chemical processes into uranium hexafluoride gas (UF6), has historically been excluded from the nuclear safeguards requirements of the 235U-based nuclear fuel cycle. The undeclared diversion of this product material could potentially provide feedstock for a clandestine weapons program for state or non-state entities. Given the changing global political environment and the increased availability of dual-use nuclear technology, the International Atomic Energy Agency has evolved its policies to emphasize safeguarding this potential feedstock material in response to dynamic and evolving potential diversion pathways. To meet the demand for instrumentation testing at conversion facilities, ORNL developed the Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in a natural uranium conversion plant. This work investigates gamma-ray signatures of UN circulating in the UNCLE facility and evaluates detector instrumentation sensitivity to UN for safeguards applications. These detector validation activities include assessing detector responses to the UN gamma-ray signatures for spectrometers based on sodium iodide, lanthanum bromide, and germanium detectors. The results of measurements under static and dynamic operating conditions at concentrations ranging from 10-90g U/L of naturally enriched UN will be presented. A range of gamma-ray lines was examined and self-attenuation factors were calculated, in addition to attenuation for transmission measurement of density, concentration and enrichment. A detailed uncertainty analysis will be presented providing insights into instrumentation limitations to spoofing.

Dewji, Shaheen A↗

Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

The declared linear density of 238 U and 235 U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar - Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of 235 U (the response) in order to estimate model parameters of the nonlinear Parte equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This article compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. Here, we find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Variations in AmLi source spectra and their estimation utilizing the 5 Ring Multiplicity Counter

Active-mode assay systems are widely used for the safeguards of uranium items to verify compliance with the Non-Proliferation Treaty. Systems such as the Active-Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL) use americium-lithium (AmLi) neutron sources to induce fissions which are measured to determine the sample mass. These systems have historically relied on calibrations derived from well-defined standards. Recently, restricted access to standards or more difficult measurements have resulted in a reliance on modeling and simulation for the calibration of systems, which introduces potential simulation biases. Furthermore, the AmLi source energy spectra commonly used in the safeguards community do not accurately represent measurement results and the spectrum uncertainty can represent a large contribution to the total modeling uncertainty in active-mode systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-10 ABUNCL Models of Fuel Testing

The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Coincidence Counting With Boron-Based Alternative Neutron Detection Technology at Pacific Northwest National Laboratory (PNNL) for the development of a 3He proportional counter alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a system based upon 10B-lined proportional tubes in a configuration typical for 3He-based coincidence counter applications. This report provides results from MCNP simulations of the General Electric Reuter-Stokes Alternative Boron-Based Uranium Neutron Coincidence Collar (ABUNCL) active configuration model with fuel pins previously measured at Los Alamos National Laboratory. A comparison of the GE-ABUNCL simulations and simulations of 3He based UNCL-II active counter (the system for which the GE-ABUNCL was targeted to replace) with the same fuel pin assemblies is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulations of Lithium-Based Neutron Coincidence Counter for Gd-Loaded Fuel

The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Lithium-Based Alternative Neutron Detection Technology Coincidence Counting for Gd-loaded Fuels at Pacific Northwest National Laboratory for the development of a lithium-based neutron coincidence counter for nondestructively assaying Gd loaded nuclear fuel. This report provides results from MCNP simulations of a lithium-based coincidence counter for the possible measurement of Gd-loaded nuclear fuel. A comparison of lithium-based simulations and UNCL-II simulations with and without Gd loaded fuel is provided. A lithium-based model, referred to as PLNS3A-R1, showed strong promise for assaying Gd loaded fuel.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Boron-lined parallel-plate Collar

This report presents boron-lined parallel plate technology features, experimental benchmarking of initial MCNP model, and parallel-plate UNCL collar optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empire: New Mexico's First Television Program

In recent years, New Mexico has hosted television and motion picture film crews working on both famous and not-so-famous productions. Perhaps the most famous of these productions was the television hit Breaking Bad. Perhaps the least famous production, which almost certainly no one remembers, is the 1962-1963 television series Empire. Empire was an hour long western that chronicled the lives of 1960s ranchers in New Mexico. The series starred Richard Egan, Ryan O’Neal, Denver Pyle, and Charles Bronson. Guest stars included Robert Vaughn (The Man from Uncle), Inger Stevens (The Farmer’s Daughter), Robert Culp (I Spy), and Telly Savalas (Kojak).

99 GENERAL AND MISCELLANEOUS↗

Neutron Based Non-Destructive Assay (NDA) Measurement Systems for Safeguard

The objectives of this project are to introduce the assay methods for plutonium measurements using the HLNC; introduce the assay method for bulk uranium measurements using the AWCC; and introduce the assay method for fuel assembly measurements using the UNCL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Evaluation of the Fast-Neutron Passive Collar (FNPC) Performance (Interim Report)

This report represents a deliverable in the Safeguards Technology WBS # Project Title, 24.1.3.1, Task 3 (Report on laboratory-based performance testing of the FNPC). A new, simplified method for the verification of the 235 U mass in fresh LEU fuel assemblies that is relatively independent of burnable poison content is being developed. LWR fresh fuel is currently verified using the uranium neutron coincidence collar (UNCL), which relies on an AmLi source to induce fission in the 235 U. AmLi neutrons are slowed down in polyethylene, so the induced fission is primarily due to thermal neutrons. Burnable poisons, which are added to nuclear fuel assemblies to extend the lifetime of the fuel, absorb neutrons that would otherwise have induced fission in the fuel, thereby reducing the neutron count rate and thus the measured 235 U mass. To remove this bias factor a correction is applied based on the operator’s declared burnable poison content. The new technique uses 238 U spontaneous fission in LWR fresh fuel rods to self-interrogate the 235 U mass. The 238 U spontaneous fission neutrons have a hard neutron energy spectrum, which means that the technique is less sensitive to burnable poisons than the AmLi based systems. This project has continued the work done over the past two years to study this new technique using the optimized 3 He based fastneutron passive collar (FNPC). Fabrication of the FNPC has been completed and measurements are in progress using the LANL mockup PWR fuel assembly. Also, preliminary evaluations of advanced analysis techniques and unattended mode operation have been performed. In FY18, the 3 He tube based detector was compared with a 10 B sealed cell based detector for the same set of PWR fuel assemblies in the Rodeo-II program. The results were that the optimized 3 He detector had higher efficiency and less weight than the 10 B based system where both systems had about the same cost. Thus, the FY19 work continued exclusively with the 3 He based detector; although, either system had the potential for future applications. However, the high efficiency of the FPNC (~24%) is critical for precise measurements of the triples rate necessary in the multiplicity advanced analysis technique which can solve for the burnable poison content.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗