Off-design performance of an organic Rankine-vapor compression cooling cycle using R1234ze(E)

In this study, a 264 kW th organic Rankine-vapor compression cycle (ORVC) was experimentally tested over a range of conditions to quantify the individual impact of off-design external conditions. The ORVC was designed to recover waste heat at 91 °C, reject heat to a liquid condenser stream at 30 °C, and produce chilled water at 7 °C. Here, the condenser heat rejection temperature was varied from 16.6 °C to 32.6 °C, the chilled water delivery temperature was varied between 2.1 °C and 13.1 °C, and the heat input temperature was varied from 91 °C to 120 °C. As the condenser heat rejection temperature decreased, the coefficient of performance (COP) of the ORVC improved from 0.558 at 30 °C to 0.682 at 16.6 °C, despite a reduction in compressor isentropic efficiency. Although the chilled water temperature variation had almost no impact on the organic Rankine cycle performance, the compressor efficiency decreased when the delivery temperature was below 7 °C. At the highest chilled water temperature, 13.1 °C, the COP of the ORVC was 0.643. Compressor stall was noted when the condenser heat rejection temperature was greater than 32.6 °C and the chilled water delivery temperature was below 2.1 °C. Increasing the driving heat source inlet temperature improved the COP of the ORVC and the thermal efficiency of the organic Rankine power cycle, while decreasing the efficiency of the compressor and the COP of vapor compression cycle. In addition, the integrated part load value of the system was determined through experimentation to be 0.682, which provides a realistic estimate of real-world performance.

30 DIRECT ENERGY CONVERSION↗

Active and Passive Storage Solutions for Low Temperature Lunar Sample Return

Active and passive thermal storage solutions to return lunar biological, physical science and/or geology samples to the Earth are under development. Temperature requirements for biological/physical science sample conditioning range from -100˚C to -153˚C and possibly down to -253˚C for geological samples. The lower limit for geological samples is derived from the temperature of permanently shadowed regions on the lunar surface and the sublimation temperature of specific volatiles of interest (i.e., H2O, NH3 and CH4). Individual samples for the lunar application are expected to be less than 50 kg with a 700 kg allowance for the container and refrigeration. Requiring no electrical power or heat rejection, passive approaches, comprised of high performance insulation and consumable Joule-Thompson cooling, may be preferred for shorter duration missions (< 30 days) to provide significant mass savings. Active storage approaches with cryogenic cooling may be necessary to preserve samples for longer periods of time. A notional passive storage concept with an internal vapor cooled shield is shown below. The vapor cooled shield contains the sample and is isolated from the outer container with concentric reflective rigid shields and conventional multi-layer and/or aerogel insulation on the outer layer. A special removable, insulating end cap to stow or retrieve the sample is included.

Lunar Sample Return↗

A simplified generic cryostat thermal model for predicting cryogen mass and lifetime

This study presents a simple generic cryostat thermal model developed for predicting cryogen mass and the lifetime of cryogenic space telescopes. The model is based on a lumped parameter representation of eight nodes and over 35 conductors. The major telescope Dewar components represented as nodes are the main cryogen tank, the three vapor-cooled shields, the outer shell, barrel baffle, and the barrel baffle heat exchanger. The input to the model consists of the vapor-cooled shield, support straps and instrument cable geometry, and the cryostat heat loads from the instrument and through the aperture. The predictions from the model were compared with those from the more detailed models of IRAS, COBE, and SIRTF. Correlation of the helium flow rates of the IRAS and COBE Dewars was 12 percent above the actual flight or ground test data and for SIRTF it was less than 2 percent of the prediction from the detailed model.

Birur, G. C.↗

Compact Vapor Chamber Cools Critical Components

Advancements in the production of proton exchange membrane fuel cells have NASA considering their use as a power source for spacecraft and robots in future space missions. With SBIR funding from Glenn Research Center, Lancaster, Pennsylvania-based Thermacore Inc. developed strong, lightweight titanium vapor chambers to keep the fuel cells operating at optimum temperatures. The company is now selling the technology for cooling electronic components.

Source record↗

The importance of accounting for the Tolman correction to surface tension for nucleation and growth modeling of Fe clusters

Gibbs free energies of clusters are required for predictive modeling of cluster growth during condensation of a cooling vapor. Here, we present a straightforward method of calculating free energies of cluster formation using the data from molecular dynamics (MD) simulations. We apply this method to iron clusters having from 2 to 100 atoms. The energies obtained are verified by comparing to an MD-simulated equilibrium cluster size distribution in a sub-saturated vapor. We show that these free energies differ significantly from those obtained with a commonly used spherical cluster approximation, which relies on a surface tension coefficient of a flat surface, as it is used in the classical nucleation theory (CNT). We show that the spherical cluster approximation in CNT can be improved by using a cluster-size-dependent Tolman correction for the surface tension. The Tolman length and effective surface tension values were derived for iron clusters, and they significantly differ from the commonly used experimentally measured values. This improved approximation does not account for geometric magic number effects responsible for spikes and troughs in densities of neighbor cluster sizes. Nonetheless, it allows to more accurately model cluster formation from a cooling vapor. It better reproduces the condensation timeline, overall shape of the cluster size distribution, average cluster size, and the distribution width. In contrast, using a constant surface tension coefficient (as done in CNT) resulted in incorrect condensation dynamics and cluster size distributions. The analytical expression for cluster nucleation rate from CNT was updated to account for the size-dependence of cluster surface tension.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operation of A Sunpower M87 Cryocooler In A Magnetic Field

The Alpha Magnetic Spectrometer-02 (AMS-02) is an experiment that will be flown as an attached payload on the International Space Station to detect dark matter and antimatter. It uses large superconducting magnets cooled with superfluid helium to bend the path of cosmic particles through a series of detectors, which then measure the mass, speed, charge, and direction of the particles. Four Sunpower M87N Stirling-cycle cryocoolers are used to extend the mission life by cooling the outer vapor-cooled shield of the dewar. The main magnet coils are separated by a distance of approximately 1 m and the coolers are located approximately 1.5 m from the center line of the magnet, where the field is as high as 925 gauss perpendicular to the cryocooler axis and 400 gauss along the cryocooler axis. Interactions between the applied magnetic field and the linear motor may result in additional forces and torques on the compressor piston. Motion of the compressor arid displacer pistons through the magnetic field spatial gradients will generate eddy currents. Additional eddy currents are created during magnet charge, discharge, and quench by the time-varying magnetic field. The results of tests to determine the magnitude of the forces, torques, and heating effects, as well as the need for additional magnetic shielding, are presented.

Breon, S. R.↗

Vibrational and rotational cooling of electrons by water vapor

The cooling of electrons by vibrational and rotational excitation of water molecules plays an important role in the thermal balance of electrons in cometary ionospheres. The energy-loss function for rotational excitation and deexcitation of H2O by electron impact is calculated theoretically. The rotational cooling rate is calculated using this loss function for a wide range of electron and neutral temperatures. The vibrational cooling rate is calculated using measured values of electron-impact vibrational excitation cross sections. Analytical formulas are provided for some of the cooling rates. The interaction of ions with H2O molecules is also discussed, and a formula is suggested for the momentum-transfer collision frequency.

Cravens, T. E.↗

Technology Demonstration Mission (TDM) Evolvable Cryogenics (eCryo) Project: Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) - Test Plan

The initial test of the SHIIVER system includes multilayer insulation and vapor cooled structure. Testing will occur in the In-Space Propulsion Facility (thermal/vacuum) and RATF (acoustic) facilities at Plum Brook Station in Sandusky Ohio. The testing will demonstrate the performance benefits of multilayer insulation and vapor based heat intercept on a “large scale” test article in a manner befitting large upper stages.

Large Scale Hydrogen Testing, Cryogenics, Multilay↗

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

Qualifying the Sunpower M87N Cryocooler for Operation in the AMS-02 Magnetic Field

The Alpha Magnetic Spectrometer-02 (AMs-02) experiment uses a superfluid helium dewar to cool a large superconducting magnet. The outer vapor-cooled shields of the dewar are to be held at 80 K by four Sunpower M87N cryocoolers. These cryocoolers have magnetic components that might interact with the external applied field generated by the superconducting magnet, thereby degrading the cryocoolers' performance. Engineering models of the Sunpower M87 have been qualified for operation in a magnetic environment similar to the AMs-02 magnetic environment. Although there was no noticeable performance degradation at field levels that were comparable to AMs-02 field levels, there appears to be a small performance degradation at higher field levels. It was theorized that there were three possible issues related to these performance losses at high magnetic fields: i) induced piston rubbing on the cylinder wall due to forces and torques on the linear motor due to the applied magnetic fields; ii) Magnetic hysteretic and/or eddy current damping of the balancer due to its motion in the applied magnetic fields; iii) Inductance losses in motor due to the applied magnetic field. The experiments conducted at the Massachusetts Institute of Technology (MIT) cyclotron facility in June 2002 were designed to test these. Tests were performed over a range of field levels that were lower, comparable, and higher than the field levels that the cryocoolers will experience in the AMs-02 operating environment. This paper describes the experiments and the inferences derived from them.

Mustafi, Shuvo↗

The Cross Equatorial Transport of the Hunga Tonga-Hunga Ha’apai Eruption Plume

On 15 January 2022, the Hunga Tonga-Hunga Ha'apai (HT) eruption injected SO 2 and water into the middle stratosphere. Shortly after the eruption, the water vapor anomaly moved northward toward and across the equator. This northward movement appears to be due to equatorial Rossby waves forced by the excessive infrared water vapor cooling. Following the early eruption stage, persistent mid-stratospheric water vapor and aerosol layers were mostly confined to Southern Hemisphere tropics (Eq. to 30°S). However, during the spring of 2022, the westerly phase of the tropical quasi-biennial oscillation (QBO) descended through the tropics. The HT water vapor and aerosol anomalies were observed to again move across the equator coincident with the shift in the Brewer-Dobson circulation and the descent of the QBO shear zone.

Atmospheric Science↗

The Cross Equatorial Transport of the Hunga Tonga-Hunga Ha'apai Eruption Plume

On 15 January 2022, the Hunga Tonga-Hunga Ha'apai (HT) eruption injected SO 2 and water into the middle stratosphere. Shortly after the eruption, the water vapor anomaly moved northward toward and across the equator. This northward movement appears to be due to equatorial Rossby waves forced by the excessive infrared water vapor cooling. Following the early eruption stage, persistent mid-stratospheric water vapor and aerosol layers were mostly confined to Southern Hemisphere tropics (Eq. to 30°S). However, during the spring of 2022, the westerly phase of the tropical quasi-biennial oscillation (QBO) descended through the tropics. The HT water vapor and aerosol anomalies were observed to again move across the equator coincident with the shift in the Brewer-Dobson circulation and the descent of the QBO shear zone.

water↗

Using Si Diodes To Detect H2 Liquid/Vapor Interfaces

Commercially available silicon-diode temperature sensors used to detect interfaces between hydrogen liquid and hydrogen vapor at steady-state saturation conditions. Sensors mounted at short intervals along rod to form rake-like array. Array inserted in tank with rod oriented vertically, where it senses level of liquid hydrogen to resolution equal to interval between sensors. Basic idea to measure voltage across sensor while supplying small electric current that heats sensor. Because vapor cools sensor less effectively than liquid does, sensor's steady-state temperature greater when sensor surrounded by vapor than when immersed in liquid. Voltage output decreases as temperature increases for silicon diodes. Thus, temperature (voltage) reading used to determine whether liquid level above or below sensor.

Dempsey, Paula Jean↗

Investigation of a para-ortho hydrogen reactor for application to spacecraft sensor cooling

The utilization of solid hydrogen in space for sensor and instrument cooling is a very efficient technique for long term cooling or for cooling at high heat rates. The solid hydrogen can provide temperatures as low as 7 to 8 K to instruments. Vapor cooling is utilized to reduce parasitic heat inputs to the 7 to 8 K stage and is effective in providing intermediate cooling for instrument components operating at higher temperatures. The use of solid hydrogen in place of helium may lead to weight reductions as large as a factor of ten and an attendent reduction in system volume. The results of an investigation of a catalytic reactor for use with a solid hydrogen cooling system is presented. Trade studies were performed on several configurations of reactor to meet the requirements of high reactor efficiency with low pressure drop. Results for the selected reactor design are presented for both liquid hydrogen systems operating at near atmospheric pressure and the solid hydrogen cooler operating as low as 1 torr.

Nast, T. C.↗

Deep Metastable Eutectic Nanometer-Scale Particles in the MgO-Al2O3-SiO2 System

Laboratory vapor phase condensation experiments systematically yield amorphous, homogeneous, nanoparticles with unique deep metastable eutectic compositions. They formed during the nucleation stage in rapidly cooling vapor systems. These nanoparticles evidence the complexity of the nucleation stage. Similar complex behavior may occur during the nucleation stage in quenched-melt laboratory experiments. Because of the bulk size of the quenched system many of such deep metastable eutectic nanodomains will anneal and adjust to local equilibrium but some will persist metastably depending on the time-temperature regime and melt/glass transformation.

Reitmeijer, Frans J. M.↗

Testing of a Spray-Bar Zero Gravity Cryogenic Vent System for Upper Stages

The capability to vent in zero gravity without resettling is a fundamental technology need that involves practically all uses of subcritical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule- Thomson (J-T) valve to extract then-nal energy from the propellant. In a cooperative effort, Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (N4HTB) was used to test a unique "spray bar" TVS system developed by Boeing. A schematic of this system is included in Figure 1. The system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it radially into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the spray bar heat exchanger element, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. Figure 2 is a plot of ullage pressure (P4) and liquid vapor pressure (PSAI) versus time. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses. The primary advantage of the spray bar configuration is that pressure reduction is achieved independent of liquid and vapor location, thereby enhancing the applicability of normal gravity test data to zero gravity conditions. The in-tank components are minimized with the proposed TVS design. Because the recirculation pump is external to the tank, no electrical power penetration of the tank is required for pump or valve operation. This is especially desirable for L02 tanks since the presence of an electrical ignition source in oxygen represents a critical failure mode. Also, since the critical components (pump, motor, valve, orifice) are external to the tank, system checkout and ground servicing/replacement are easier. For zero-g operation, component replacement external to the tank may be a significant benefit. In addition to satisfying the zero g TVS design objectives, the TVS concept tested offers additional benefits to the integrated subcritical cryogenic storage and launch system.

Lak, Tibor↗

Zero Gravity Cryogenic Vent System Concepts for Upper Stages

The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray bar system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy is required. a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point. the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating, boil-off losses.

Flachbart, Robin H.↗

Zero Gravity Cryogenic Vent System Concepts for Upper Stages

The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space, and would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray-bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray-bar system consists of a recirculation pump, a parallel flow concentric tube heat exchanger, and a spray-bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses.

Flachbart, Robin H.↗