Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wheatstone Bridge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Research on pressure sensors for biomedical instruments

The development of a piezo-resistive pressure transducer is discussed suitable for recording pressures typically encountered in biomedical applications. The pressure transducer consists of a thin silicon diaphragm containing four strain-sensitive resistors, and is fabricated using silicon monolithic integrated-circuit technology. The pressure transducers can be as small as 0.7 mm outer diameter, and are, as a result, suitable for mounting at the tip of a catheter. Pressure-induced stress in the diaphragm is sensed by the resistors, which are interconnected to form a Wheatstone bridge.

Angell, J. B.↗

Thin film atomic hydrogen detectors

Thin film and bead thermistor atomic surface recombination hydrogen detectors were investigated both experimentally and theoretically. Devices were constructed on a thin Mylar film substrate. Using suitable Wheatstone bridge techniques sensitivities of 80 microvolts/2x10 to the 13th power atoms/sec are attainable with response time constants on the order of 5 seconds.

Gruber, C. L.↗

A dual-amplifier hot-wire anemometer

The conceptual design of a dual-amplifier constant-temperature hot-wire anemometer is described. This hot-wire anemometer consists of three basic independent modules: a Wheatstone bridge in which the hot wire is one of its arms, an error-correction amplifier, and a voltage-controlled current source. The last two modules constitute the feedback network of this hot-wire anemometer. Thus the output voltage across the wire is a true function of the instantaneous changes in the wire resistance induced by the cooling effect of the flow. The dual-amplifier is capable of reaching relatively high frequency response through adequate selection of its active elements. Suitable gain of the error-correction amplifier and proper choice of the transfer function of the current source has yielded a frequency bandwidth up to 200 kHz.

Sadeh, W. Z.↗

Miniature piezoresistive solid state integrated pressure sensors

The characteristics of silicon pressure sensors with an ultra-small diaphragm are described. The pressure sensors utilize rectangular diaphragm as small as 0.0127 x 0.0254 cm and a p-type Wheatstone bridge consisting of diffused piezoresistive elements, 0.000254 cm by 0.00254 cm. These sensors exhibit as high as 0.5 MHz natural frequency and 1 mV/V/psi pressure sensitivity. Fabrication techniques and high frequency results from shock tube testing and low frequency comparison with microphones are presented.

Kahng, S. K.↗

Thin film strain transducer

A strain transducer system and process for making the same is disclosed. A beryllium copper ring having four strain gages is electrically connected in Wheatstone bridge fashion to the output instrumentation. Tabs are bonded to a balloon or like surface with strain on the surface causing bending of a ring which provides an electrical signal through the gages proportional to the surface strain. A photographic pattern of a one half ring segment as placed on a sheet of beryllium copper for chem-mill etch formation is illustrated.

Rand, J. L.↗

Thin film strain transducer

A strain transducer system and process for making same is disclosed wherein a beryllium-copper ring having four strain gages disposed thereon is electrically connected in Wheatstone bridge fashion to output instrumentation. Tabs are bonded to a balloon or like surface with strain on the surface causing bending of the ring and providing an electrical signal through the gages proportional to the surface strain. A figure is provided which illustrates a pattern of a one-half ring segment as placed on a sheet of beryllium-copper for chem-mill etch formation, prior to bending and welding of a pair of the segments to form a ring structure.

Rand, J. L.↗

Instrumentation for sensing moisture content of material using a transient thermal pulse

Instrumentation for sensing moisture content of material using a transient thermal pulse is comprised of a sensing probe having a sensing element in the form of a ribbon excited by a constant current pulse from a source to increase the temperature and therefore the resistance of the ribbon linearly. Moisture in web material will limit the increase of temperature during the pulse in proportion to the moisture content. This increase in temperature produces a proportional increase in resistivity which is measured with a wheatstone bridge as a change in voltage displayed by a measurement display unit. The probe is glued in a shallow groove of a Lucite bar and connected to copper pins embedded in the bar.

Yang, L. C.↗

Omnivector Probe Measures Airflow

Problems overcome with development of new omnivector anemometer. Includes cylindrical sensing element with eight strain gages. Gages, connected in two Wheatstone bridges, sense two perpendicular components of flow across cylinder. Designed and tested, has fixed-position sensing element capable of simultaneoulsy measuring steady and unsteady velocity head and flow direction of moving fluid over complete 360-degree angle in two-dimensional flow.

Krause, L.↗

Measuring Poisson Ratios at Low Temperatures

Simple extensometer ring measures bulges of specimens in compression. New method of measuring Poisson's ratio used on brittle ceramic materials at cryogenic temperatures. Extensometer ring encircles cylindrical specimen. Four strain gauges connected in fully active Wheatstone bridge self-temperature-compensating. Used at temperatures as low as liquid helium.

Boozon, R. S.↗

Hand-Strength Meter

Special grip-strength meter designed for accurate, reproducible measurement of hand rehabilitation. Four strain gauges connected in Wheatstone bridge to measure deflection caused by gripping hand. Compressive force exerted by hand transmitted to measuring beams. Beams therefore deflected or strained, and mechanical strain sensed by strain gauges and converted into electrical signal. After amplification and conditioning, signal displayed on LED as measure of gripping strength of hand.

Tcheng, Ping↗

Microtronic Flow Transducer

Novel microelectronic airflow and gas-flow transducer developed. Has no moving parts and constructed by use of variation on ordinary technology for processing of planar silicon microelectronics, where hundreds or thousands of identical devices concurrently produced on single chip as easily as can one. Gas-flow transducer based upon integrated Wheatstone bridge in silicon chip. Legs doped with gold and isolated thermally by etching away surrounding material (except corners). Because of small size, sensitivity, and good directional capability of new transducer, numerous potential applications in measurement of vortexes, flows in inlets to pipes, and other complicated flows.

Sundberg, Gale R.↗

Improved Circuit For Hot-Film Anemometer

Circuit suitable for automation or computer control of setup and operation. Hot-film or hot-wire anemometer circuit features individual current drives for two arms of wheatstone bridge, plus other features that provide improved calibration and automated or computer-controlled operation.

Gray, David L.↗

The constant current loop - A new paradigm for resistance signal conditioning

A practical single constant current loop circuit for the signal conditioning of variable-resistance transducers has been synthesized, analyzed, and demonstrated. The strain gage and the resistance temperature device are examples of variable-resistance sensors. Lead wires connect variable-resistance sensors to remotely located signal-conditioning hardware. The presence of lead wires in the conventional Wheatstone bridge signal-conditioning circuit introduces undesired effects that reduce the quality of the data from the remote sensors. A practical approach is presented for suppressing essentially all lead wire resistance effects while indicating only the change in resistance value. An adaptation of the current loop circuit is presented that simultaneously provides an output signal voltage directly proportional to transducer resistance change and provides temperature information that is unaffected by transducer and lead wire resistance variations.

Anderson, Karl F.↗

A Hot-wire Circuit with Very Small Time Lag

A circuit for a hot-wire anemometer for the measurement of fluctuating flow is presented in the present report. The principal elements of the circuit are a Wheatstone bridge, one branch of which is the hot wire; and an electronic amplifier and a current regulator for the brief current which in combination maintain the bridge balance constant. Hence the hot wire is kept at practically constant resistance and temperature, and the time lag caused by thermal inertia of the wire is thereby reduced. Through the addition of a nonlinear amplifying stage the reading of the instrument has been rendered proportional to the velocity. A discussion of certain characteristics of the circuit and the results of related calibrating tests are given.

Weske, John R↗

High-Temperature Resistance Strain Gauges

Resistance strain gauges developed for use at high temperatures in demanding applications like testing aircraft engines and structures. Measures static strains at temperatures up to 800 degrees C. Small and highly reproducible. Readings corrected for temperature within small tolerances, provided temperatures measured simultaneously by thermocouples or other suitable devices. Connected in wheatstone bridge.

Lei, Jih-Fen↗

Compensated High Temperature Strain Gage

A device for measuring strain in substrates at high temperatures in which the thermally induced apparent strain is nulled is described. Two gages are used, one active gage and one compensating gage. Both gages are placed on the substrate to be gaged; the active gage is attached such that it responds to mechanical and thermally induced apparent strain while the compensating gage is attached such that it does not respond to mechanical strain and and measures only thermally induced apparent strain. A thermal blanket is placed over the two gages to maintain the gages at the same temperature. The two gages are wired as adjacent arms of a wheatstone bridge which nulls the thermally induced apparent strain giving a true reading of the mechanical strain in the substrate.

Source record↗

Experimental Performance of a Micromachined Heat Flux Sensor

Steady-state and frequency response calibration of a microfabricated heat-flux sensor have been completed. This sensor is batch fabricated using standard, micromachining techniques, allowing both miniaturization and the ability to create arrays of sensors and their corresponding interconnects. Both high-frequency and spatial response is desired, so the sensors are both thin and of small cross-sectional area. Thin-film, temperature-sensitive resistors are used as the active gauge elements. Two sensor configurations are investigated: (1) a Wheatstone-bridge using four resistors; and (2) a simple, two-resistor design. In each design, one resistor (or pair) is covered by a thin layer (5000 A) thermal barrier; the other resistor (or pair) is covered by a thick (5 microns) thermal barrier. The active area of a single resistor is 360 microns by 360 microns; the total gauge area is 1.5 mm square. The resistors are made of 2000 A-thick metal; and the entire gauge is fabricated on a 25 microns-thick flexible, polyimide substrate. Heat flux through the surface changes the temperature of the resistors and produces a corresponding change in resistance. Sensors were calibrated using two radiation heat sources: (1) a furnace for steady-state, and (2) a light and chopper for frequency response.

TEMPERATURE SENSITIVE ELEMENTS↗

Microscale Investigation of Thermo-Fluid Transport in the Transition FIL, Region of an Evaporating Capillary Meniscus Using a Microgravity Environment

In order to enhance the fundamental understanding of thin film evaporation and thereby improve the critical design concept for two-phase heat transfer devices, microscale heat and mass transport is to be investigated for the transition film region using state-of-the-art optical diagnostic techniques. By utilizing a microgravity environment, the length scales of the transition film region can be extended sufficiently, from submicron to micron, to probe and measure the microscale transport fields which are affected by intermolecular forces. Extension of the thin film dimensions under microgravity will be achieved by using a conical evaporator made of a thin silicon substrate under which concentric and individually controlled micro-heaters are vapor-deposited to maintain either a constant surface temperature or a controlled temperature variation. Local heat transfer rates, required to maintain the desired wall temperature boundary condition, will be measured and recorded by the concentric thermoresistance heaters controlled by a Wheatstone bridge circuit, The proposed experiment employs a novel technique to maintain a constant liquid volume and liquid pressure in the capillary region of the evaporating meniscus so as to maintain quasi-stationary conditions during measurements on the transition film region. Alternating use of Fizeau interferometry via white and monochromatic light sources will measure the thin film slope and thickness variation, respectively. Molecular Fluorescence Tracking Velocimetry (MFTV), utilizing caged fluorophores of approximately 10-nm in size as seeding particles, will be used to measure the velocity profiles in the thin film region. An optical sectioning technique using confocal microscopy will allow submicron depthwise resolution for the velocity measurements within the film for thicknesses on the order of a few microns. Digital analysis of the fluorescence image-displacement PDFs, as described in the main proposal, can further enhance the depthwise resolution.

Kihm, K. D.↗