Search NASA⌕ Search

SEARCH · Search NASA

Results for “XCT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Deep Learning Super-Resolution X-Ray Computed Tomography Algorithms for Additive Manufacturing

Industrial X-ray computed tomography (XCT) is a nondestructive method for inspection and characterization of additively manufactured (AM) materials and parts. In practice, the resolution of XCT can be limited by factors such as detector binning, restricted field of view for large-scale objects, system blur, motion during scanning, and acquisition settings. These limitations can reduce the detectability of critical flaws such as pores, cracks, and lack of fusion. Super-resolution (SR) techniques offer a promising solution for improving the effective resolution and image quality of XCT reconstructions without the need for expensive hardware upgrades or laborious, time-consuming scans. In particular, deep learning-based SR methods have garnered attention in recent years as powerful tools for reconstructing high-resolution volumes from low-resolution inputs. In this work, a novel deep learning-based SR method is proposed for XCT scans of AM parts, and compared against several existing state-of-the-art (SOTA) methods. The proposed method, Simurgh-SR, is built on the pre-existing Simurgh framework and consists of a 2.5D U-Net trained to map low-quality inputs containing noise and artifacts to high-quality reconstructions characterized by higher flaw contrast, better noise texture, and reduced artifacts. The experimental results demonstrate superior performance of Simurgh-SR in performing 4× SR on real industrial XCT scans of thick 316L components, enhancing the structural similarity score and peak signal-to-noise ratio (>7dB) compared to the LR counterpart while improving the F1-score for flaw detection by more than 2.3× when compared to alternative SOTA SR methods. This improvement enables more accurate and significantly faster characterization of metal AM components. Additionally, Simurgh-SR was trained for both 2X and 4X SR and performs effectively at both levels, enabling the use of a single model for various SR factors.

Rahman, Obaid [ORNL] (ORCID:0000000277810840)↗

Advancing Additive Manufacturing Through Artificial Intelligence–Powered, High-Throughput, Nondestructive Characterization and Process Optimization

This Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and ZEISS Industrial Metrology has demonstrated the transformative potential of artificial intelligence (AI)-enabled x-ray computed tomography (XCT) to accelerate the qualification and certification of additively manufactured (AM) parts. At the core of this effort is Simurgh, an AI-powered XCT reconstruction framework jointly advanced by ORNL and ZEISS that integrates computer-aided design (CAD) models, physics-based simulations, and deep learning to overcome the long-standing challenges of metal artifact correction, long scan durations, and limited flaw detectability in dense and geometrically complex components. Simurgh enables high-throughput, high-quality 3D reconstruction from sparse and fast scans, which reduces XCT acquisition times by more than an order of magnitude and simultaneously improves defect detection limits by up to fourfold compared with industry-standard approaches. This capability reduces scan costs by more than 50%, lowers labor overhead, and makes XCT characterization economically viable for routine industrial use. By enabling reliable flaw detection in minutes rather than hours, Simurgh facilitates real-time feedback loops for process parameter optimization, which was highlighted in a recent npj Computational Materials (a Nature journal) issue. In the published study, more than 100 alloy coupons were characterized within a single day. This work represents a tenfold acceleration in the development of novel AM alloys and processes compared with conventional workflows. The ZEISS collaboration has also demonstrated the scalability of Simurgh to diverse application domains, including aerospace, nuclear, automotive, and biomedical components; in these applications, ensuring structural integrity is paramount. By drastically reducing barriers to XCT adoption, this partnership has laid the foundation for digital twins and data-driven certification pipelines and directly addressed bottlenecks in qualifying new materials and designs. Together, ORNL and ZEISS have shown that Simurgh advances the state of the art in nondestructive evaluation and aligns with the broader mission of enabling Industry 4.0 manufacturing ecosystems, in which intelligent, cost-effective, rapid quality assurance is integral to accelerating innovation and ensuring safety in critical applications.

36 MATERIALS SCIENCE↗

Defect And Damage Characterization Of Additively Manufactured Titanium Alloy Ti-5553 Using Traditional Computed Tomography Volume Segmentation And Machine Learning Algorithms

The mechanical response of a component is affected by defects, such as porosity, arising from the laser powder bed fusion (LPBF) fabrication process. Thus, it is important to develop accurate and efficient inspection methods for identifying porosity. In this work, porosity identified in an X-ray computed tomography (XCT) volume of a Ti-5553 coupon was compared to pores identified in a serial sectioned volume that represented the ground truth. The porosity of the XCT scan was identified using contrast-based, ISO-based, and machine learning (ML) methods for segmentation. Large inherent porosity was easy to identify, but the ISO thresholding still struggled due to the intensity gradient resulting from both the beam hardening in XCT and the uneven lighting of the serial sectioning panels. Further, the results show that ML-based methods were better suited for identifying small pores and reducing the amount of false positives. Additionally, high strain-rate impact testing was done on some of the XCT samples as well as post-mortem XCT inspection, and the same suite of segmentation and quantification tools were used to identify the large spallation cavities. The comparison of porosity pre- and post-mortem provides insight on the influence of the LPBF porosity on the formation of spall cavities.

36 MATERIALS SCIENCE↗

Multi-Scale Characterization of Porosity and Cracks in Silicon Carbide Cladding after Transient Reactor Test Facility Irradiation

Silicon carbide (SiC) ceramic matrix composite (CMC) cladding is currently being pursued as one of the leading candidates for accident-tolerant fuel (ATF) cladding for light water reactor applications. The morphology of fabrication defects, including the size and shape of voids, is one of the key challenges that impacts cladding performance and guarantees reactor safety. Therefore, quantification of defects’ size, location, distribution, and leak paths is critical to determining SiC CMC in-core performance. This research aims to provide quantitative insight into the defect’s distribution under multi-scale characterization at different length scales before and after different Transient Reactor Test Facility (TREAT) irradiation tests. A non-destructive multi-scale evaluation of irradiated SiC will help to assess critical microstructural defects from production and/or experimental testing to better understand and predict overall cladding performance. X-ray computed tomography (XCT), a non-destructive, data-rich characterization technique, is combined with lower length scale electronic microscopic characterization, which provides microscale morphology and structural characterization. This paper discusses a fully automatic workflow to detect and analyze SiC-SiC defects using image processing techniques on 3D X-ray images. Following the XCT data analysis, advanced characterizations from focused ion beam (FIB) and transmission electron microscopy (TEM) were conducted to verify the findings from the XCT data, especially quantitative results from local nano-scale TEM 3D tomography data, which were utilized to complement the 3D XCT results. In this work, three SiC samples (two irradiated and one unirradiated) provided by General Atomics are investigated. The irradiated samples were irradiated in a way that was expected to induce cracking, and indeed, the automated workflow developed in this work was able to successfully identify and characterize the defects formation in the irradiated samples while detecting no observed cracking in the unirradiated sample. These results demonstrate the value of automated XCT tools to better understand the damage and damage propagation in SiC-SiC structures for nuclear applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simurgh: A Framework for Cad-Driven Deep Learning Based X-Ray CT Reconstruction

High-resolution X-ray computed tomography (XCT) is an important technique for the inspection of additively manufactured (AM) parts. While XCT is typically used off-line to inspect a subset of manufactured parts, significantly accelerating measurement speed while retaining accuracy would enable use of XCT for in-line inspection to rapidly identify defects in each part as it is manufactured. Here, we propose a deep learning (DL) based approach that uses computer aided design (CAD) models of the AM parts and physics-based information to rapidly produce high-quality reconstructions from sparse XCT measurements without high quality ground truth data. Our approach uses a generative adversarial neural network (GAN) to produced realistic training data from the CAD-based simulations and a deep neural network that is trained using data from the first stage to produce accurate 3D reconstructions. Using experimental XCT data of metal parts, we demonstrate enhanced defect detection capabilities while dramatically reducing the scan time.

Ziabari, Amir↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

Benchmarking image processing techniques for porosity measurement in polymer additive manufacturing: Review and experimental analysis

An image processing workflow is proposed for porosity measurement in polymer additive manufacturing. Various techniques, including global and local thresholding, region growing, and K-means clustering, were applied to microscopic images of carbon fiber reinforced acrylonitrile butadiene styrene (CF-ABS) and benchmarked for their ability to accurately measure porosity. Global methods included Otsu, minimum error, iterative, and entropy-based thresholding, while local methods included Niblack, Bernsen, Sauvola, and Bradley-Roth algorithms. Artificial uneven illumination was introduced to test local adaptive thresholds. Results showed significant differences in porosity values across methods. Otsu, region growing, and K-means clustering excelled under uniform illumination, while Sauvola and Bradley-Roth performed better with uneven illumination. Comparison with X-ray computed tomography (XCT) revealed slightly lower porosity values (2.55 %) than optimized methods (2.73–2.79 %) due to XCT's lower resolution excluding smaller pores. While XCT offers finer pore detection, it limits sample volume and underestimates porosity due to spatial variation. Validation using artificial grayscale images with 5 % porosity confirmed that Otsu, Bradley-Roth, region growing, and Sauvola algorithms produced accurate results. Although tested on a single material system, these methods can be adapted to others with optimization. In conclusion, given XCT's high computational and time costs, this study highlights suitable image processing techniques as cost-effective alternatives for porosity analysis in polymer composites.

Additive manufacturing↗

A mesoscale 3D model of irradiated concrete informed via a 2.5 U-Net semantic segmentation

The concrete biological shield in light-water reactors is exposed to neutron and gamma irradiation, which deteriorates the concrete’s mechanical properties in the long term. To assess the irradiation-induced damage, predictive mechanical models are developed and used in parallel with the characterization of irradiated concrete samples. Realistic 3D simulation domains can drastically improve a model’s prediction. In this work, we utilized x-ray computed tomography (XCT) data of a concrete specimen to reconstruct its 3D microstructure. The XCT data shows low contrast between the concrete’s aggregates and cement paste, resulting in poor image segmentation when using traditional unsupervised techniques. To address this issue, we developed and trained a 2.5D U-Net model on only 24 pre-labeled XCT layers to segment 651 layers of the XCT data. The overall F1-score of the model is approximately 96%. Then, we created a 3D finite element (FE) mesh based on the stack of segmented images. The FE model contains radiation-induced expansion, damage, and creep. The constitutive equations are adapted to each phase (aggregates and cement paste). Here, we simulated the effects of neutron irradiation in the concrete specimen as well as the specimen’s mechanical response to uniaxial compression. Finally, model validation was performed using experimental data on similar concrete specimens in the literature.

2.5D U-Net↗

Analysis of electrically conductive adhesives in shingled solar modules by X-ray imaging techniques

The failure mechanisms of electrically conductive adhesives (ECAs) in solar modules are difficult to study since the ECA layer is not easily accessible within the module package. In this work, we present two complementary imaging modalities—X-ray radiography and X-ray microcomputed tomography (XCT)—that reveal important morphological features of the ECA within a shingled module. X-ray radiography uses single X-ray projections to provide fast and non-destructive imaging of the shingled interconnection, illuminating the alignment of the ECA relative to the busbars, the size and shape of the ECA, and the presence of voids within it. Through X-ray radiography, we observed, for example, that the average void coverage area of ECA segments reduced from 36.7% to 4.4% when an ECA was cured for 60 s prior to module lamination. XCT is a three-dimensional imaging technique that can identify regions in which the ECA makes electrical contact to busbars on cells and regions in which the ECA has cracked, among other features. XCT can also be used to image the individual metal particles within ECA, from which the metal volume fraction of an ECA was found here to be 70.4%. This is a quantity that is not often reported by ECA manufacturers but is important to ensure isotropic conduction. As X-ray projections can be performed non-destructively on full modules, the technique may be used to pinpoint ECA failures in accelerated degradation testing. XCT is complementary and is suited to forensic analysis of failing modules.

14 SOLAR ENERGY↗

2.5D Super-Resolution Approaches for X-Ray Computed Tomography-Based Inspection of Additively Manufactured Parts

X-ray computed tomography (XCT) is a key tool in non-destructive evaluation of additively manufactured (AM) parts, allowing for internal inspection and defect detection. Despite its widespread use, obtaining high-resolution CT scans can be extremely time consuming. This issue can be mitigated by performing scans at lower resolutions; however, reducing the resolution compromises spatial detail, limiting the accuracy of defect detection. Super-resolution algorithms offer a promising solution for overcoming resolution limitations in XCT reconstructions of AM parts, enabling more accurate detection of defects. While 2D super-resolution methods have demonstrated state-of-the-art performance on natural images, they tend to under-perform when directly applied to XCT slices. On the other hand, 3D super-resolution methods are computationally expensive, making them infeasible for large-scale applications. To address these challenges, we propose a 2.5D super-resolution approach tailored for XCT of AM parts. Our method enhances the resolution of individual slices by leveraging multi-slice information from neighboring 2D slices without the significant computational overhead of full 3D methods. Specifically, we use neighboring low-resolution slices to super-resolve the center slice, exploiting inter-slice spatial context while maintaining computational efficiency. This approach bridges the gap between 2D and 3D methods, offering a practical solution for high-throughput defect detection in AM parts.

Sullivan, Haley↗

Lithium Metal Battery Quality Control via Transformer–CNN Segmentation

Lithium metal battery (LMB) has the potential to be the next-generation battery system because of its high theoretical energy density. However, defects known as dendrites are formed by heterogeneous lithium (Li) plating, which hinders the development and utilization of LMBs. Non-destructive techniques to observe the dendrite morphology often use X-ray computed tomography (XCT) to provide cross-sectional views. To retrieve three-dimensional structures inside a battery, image segmentation becomes essential to quantitatively analyze XCT images. This work proposes a new semantic segmentation approach using a transformer-based neural network called TransforCNN that is capable of segmenting out dendrites from XCT data. In addition, we compare the performance of the proposed TransforCNN with three other algorithms, U-Net, Y-Net, and E-Net, consisting of an ensemble network model for XCT analysis. Our results show the advantages of using TransforCNN when evaluating over-segmentation metrics, such as mean intersection over union (mIoU) and mean Dice similarity coefficient (mDSC), as well as through several qualitatively comparative visualizations.

Quenum, Jerome (ORCID:0000000271265853)↗

Ability of x‐ray computed tomography to resolve critical flaw size in laser‐based, paste stereolithography ceramic printing of alumina

Abstract Complex alumina parts were printed using vat photopolymerization (VPP), which is a stereolithography‐based additive manufacturing (AM) technique used to shape ceramic preforms, or green parts. The critical flaw size was determined using classical fracture mechanics techniques. The strength and fracture toughness were measured and compared to flaws detected in x‐ray computed tomography (XCT or CT) distributions as well as the fracture surfaces. The strength was lower compared traditionally made alumina, and that is due to layering effects, slurry defects, and printing defects. The critical flaw size from fracture mechanics was 206 µm. XCT has high enough resolution to detect the critical flaw size and much smaller features, where the average flaw size observed in CT scans was around 80–100 µm. The fracture surfaces indicate that flaws causing failure are larger than that of the critical flaw size (∼300 µm), but fracture surfaces do not show definitive features compared to traditionally made ceramics. Since XCT can observe flaws smaller than the critical flaw size, this method can be used as a screening technique.

36 MATERIALS SCIENCE↗

Build Orientation Dependent Microstructure in Polymer Laser Sintering: Relationship to Part Performance and Evolution with Aging

Laser sintering (LS) is widely used to produce functional polymeric parts; however, the resulting parts are often limited by their porous structure, and performance of the part may be strongly anisotropic. Relating the structural features of parts to build process conditions or powder feedstock has been explored previously. In contrast, little is known regarding how the unique internal structures of LS parts evolve and relate to their performance later in their life cycle, for example, after use in a real-world operating environment. In this study, a tightly controlled LS build process and measurement campaign by standard X-ray computed tomography (XCT), supported by high-resolution synchrotron XCT, was used to benchmark the internal microstructure (e.g. porosity) as a function of four different build orientations in printed polyamide-12 (PA-12) parts. The initial performance of the parts after printing was characterized by tensile testing and dynamic mechanical analysis (DMA). Arrays of PA-12 parts in different build orientations were exposed to steam (under pressure) and air across multiple temperature and time points for the purposes of accelerated aging through oxidative and hydrolytic breakdown. Exposing parts to steam dramatically altered the internal microstructure and functional properties such as the glass transition temperature, tensile properties, and damping behavior. Notably, post-aging XCT revealed large microstructural changes after only 40 h of steam treatment relative to the as-printed specimens. Furthermore, pore reorganization and changes in crystallinity occurred regardless of whether the steam temperature was aggressive enough to induce a significant loss in mechanical properties. The build orientation dependence on the aging rate was minimal with the relative trend in performance persisting across most metrics among the different orientations even after aging.

36 MATERIALS SCIENCE↗

Rapid macrovoid characterization in membranes prepared via nonsolvent-induced phase separation: A comparison between 2D and 3D techniques

Optimizing the performance of asymmetric membranes prepared via nonsolvent-induced phase separation (NIPS) requires a quantitative understanding of how processing variables influence membrane morphology. Presently, the most useful structural quantification techniques require 3D visualization of the membrane structure and are best suited for studies seeking detailed information on small datasets. This study proposes and validates a rapid and accurate technique for quantifying macroporosity (i.e., D m ), a simple descriptor of sublayer macrovoid content in asymmetric membranes D m . values measured from segmented cross-sectional imaging performed via X-ray computed tomography (XCT) and scanning electron microscopy (SEM) are presented and compared for three asymmetric membranes prepared from commercial polymers. Importantly, analyses of 3D XCT membrane reconstructions reveal that D m is described by a single, centralized mean, which demonstrates that macrovoid content is spatially homogenous. Thus, D m can be approximated from limited sampling of the 2D cross-sectional membrane structure via SEM. A proposed 2D SEM sampling method provides D m estimates within ±6% of corresponding 3D XCT values with 30 independent measurements for the three membranes. Further sensitivity is achieved using complementary descriptors such as macrovoid count density (i.e., C m ). This technique is thus a useful tool for characterizing macroporosity from a broad selection of membrane samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of a TRISO MiniFuel irradiation experiment with data-informed uncertainty quantification

An irradiation experiment using tristructural isotropic (TRISO) fuel particles and the miniature fuel (MiniFuel) irradiation vehicle was performed in Oak Ridge National Laboratory’s High Flux Isotope Reactor (HFIR) to support development of the Kairos Power fluoride salt–cooled, high-temperature reactor (KP-FHR). Here, this paper describes modeling predictions of temperatures and fuel burnup for the as-built experiment. An uncertainty quantification (UQ) analysis was performed to determine the effect of TRISO particle volume and position on the temperature predictions at various fuel heat generation rates (HGRs). This UQ study utilized fuel kernel position and volume measurements previously collected using X-ray computed tomography (XCT) techniques and Monte Carlo sampling methods to generate fuel compact cases that were then analyzed using a finite element thermal model. The UQ analysis indicated that uncertainty in calculated temperatures caused by varying TRISO particle arrangement is relatively small, even at high fuel HGR. Final predictions of particle temperatures throughout the irradiation are shown to be relevant to KP-FHR normal and off-normal operating conditions and to previous TRISO irradiation experiments. The combination of XCT with UQ analyses will inform post-irradiation examination (PIE) of the irradiated fuel compacts, and these analyses can be used to develop fuel performance models for coated particle fuel forms. Both PIE of separate-effects irradiation data and enhanced fuel performance modeling support accelerated qualification of TRISO fuels for a broad range of advanced reactor applications. The novel approach demonstrated here of measuring TRISO particle configurations with XCT methods and generating representative fuel compacts for finite element modeling and UQ analysis could be leveraged by the broader particle fuel community in the development of other TRISO fuel experiments in which these variables may have a significant impact on key outcomes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Artificial neural network approach for multiphase segmentation of battery electrode nano-CT images

The segmentation of tomographic images of the battery electrode is a crucial processing step, which will have an additional impact on the results of material characterization and electrochemical simulation. However, manually labeling X-ray CT images (XCT) is time-consuming, and these XCT images are generally difficult to segment with histographical methods. We propose a deep learning approach with an asymmetrical depth encode-decoder convolutional neural network (CNN) for real-world battery material datasets. This network achieves high accuracy while requiring small amounts of labeled data and predicts a volume of billions voxel within few minutes. While applying supervised machine learning for segmenting real-world data, the ground truth is often absent. The results of segmentation are usually qualitatively justified by visual judgement. We try to unravel this fuzzy definition of segmentation quality by identifying the uncertainty due to the human bias diluted in the training data. Further CNN trainings using synthetic data show quantitative impact of such uncertainty on the determination of material’s properties. Nano-XCT datasets of various battery materials have been successfully segmented by training this neural network from scratch. We will also show that applying the transfer learning, which consists of reusing a well-trained network, can improve the accuracy of a similar dataset.

25 ENERGY STORAGE↗

Enabling rapid X-ray CT characterisation for additive manufacturing using CAD models and deep learning-based reconstruction

Metal additive manufacturing (AM) offers flexibility and cost-effectiveness for printing complex parts but is limited to few alloys. Qualifying new alloys requires process parameter optimisation to produce consistent, high-quality components. High-resolution X-ray computed tomography (XCT) has not been effective for this task due to artifacts, slow scan speed, and costs. We propose a deep learning-based approach for rapid XCT acquisition and reconstruction of metal AM parts, leveraging computer-aided design models and physics-based simulations of nonlinear interactions between X-ray radiation and metals. This significantly reduces beam hardening and common XCT artifacts. We demonstrate high-throughput characterisation of over a hundred AlCe alloy components, quantifying improvements in characterisation time and quality compared to high-resolution microscopy and pycnometry. Our approach facilitates investigating the impact of process parameters and their geometry dependence in metal AM.

36 MATERIALS SCIENCE↗

Correlative single-cell hard X-ray computed tomography and X-ray fluorescence imaging

Abstract X-ray computed tomography (XCT) and X-ray fluorescence (XRF) imaging are two non-invasive imaging techniques to study cellular structures and chemical element distributions, respectively. However, correlative X-ray computed tomography and fluorescence imaging for the same cell have yet to be routinely realized due to challenges in sample preparation and X-ray radiation damage. Here we report an integrated experimental and computational workflow for achieving correlative multi-modality X-ray imaging of a single cell. The method consists of the preparation of radiation-resistant single-cell samples using live-cell imaging-assisted chemical fixation and freeze-drying procedures, targeting and labeling cells for correlative XCT and XRF measurement, and computational reconstruction of the correlative and multi-modality images. With XCT, cellular structures including the overall structure and intracellular organelles are visualized, while XRF imaging reveals the distribution of multiple chemical elements within the same cell. Our correlative method demonstrates the feasibility and broad applicability of using X-rays to understand cellular structures and the roles of chemical elements and related proteins in signaling and other biological processes.

59 BASIC BIOLOGICAL SCIENCES↗