Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand's Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the funda- mental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scatter- ing provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon’s internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (Gn M ) to unprecedented Q2 using Durand’s method, also known as the “ratio” method. Systematic errors are greatly reduced by extracting Gn M from the ratio of neutron-coincident (D(e, e'n)) to proton-coincident (D(e, e'p)) quasi-elastic electron scattering from deuteron. The scattered electrons were detected in the BigBite spectrometer, which features multiple Gas Elec- tron Multiplier (GEM) layers with large active area for high-precision tracking at very high rates. Simultaneous nucleon detection was performed by the Super BigBite spectrometer, which utilizes a dipole magnet with large solid angle acceptance at forward angles and a novel hadron calorimeter with very high and comparable detection efficiencies for both protons and neutrons. This setup could handle very high luminosity, making high-Q2 measurements feasible. Data were collected at five Q2 points: 3, 4.5, 7.4, 9.9, and 13.6 (GeV/c)2. Preliminary results are reported for all, with the lowest two Q2 points in good agreement with existing world data, while the higher points significantly extend the Q2 range in which Gn M is known accurately. The precision of the highest Q2 point is expected to remain unmatched for years to come.

Datta, Provakar↗

SU-F-T-583: Comparison of EBT3 Radiochromic Film Densitometry with Narrow Bandwidth LED Source in Point, Slot and Full Aperture Geometries

Purpose: Film densitometers optimized for radiochromic EBT3 film are not commercially available and flatbed document scanners are limited by broad spectral overlap of the red green and blue channels and polarization effects. Non-polarized, narrow bandwith, intensity stabilized light emitting diode (LED) light sources were constructed and transmission measurements compared for point, slot and full aperture geometries. Methods: LED’s with 10 nm bandwidths were focused to 1 mm spots for point scanning. The LED’s back-illuminated a 6 mm diameter diffuser near the focal point of a 25 cm diameter Fresnel lens for slot and full aperture transmission imaging. Films were located at the aperture plane, 15 cm from the lens and imaged with a 16 bit digital camera with 50 mm lens. Sheets, 10×8 cm, were irradiated to 25 Gy with a 4×4 cm 6 MV photon beam. Transmission measurements with a 633nm, linearly polarized laser were used as lowacceptance angle reference geometry. Results: LED intensity stabilized to <1% within one minute of startup. The useful transmission range increased as the acceptance angle decreased, laser(∼2%)> spot(∼3%)> slot(∼5%)> full aperture(∼10%). The Fresnel lens introduced a 4-fold polarization symmetry that increased radially causing a 2% change in transmission at 10 cm from the optic axis for EBT3 film. Polarized spot densitometer and laser transmission were similar. Conclusion: Spectrally filtered LED sources were effective for transmission measurements of radiochromic films. Because of polarization sensitivity of EBT3 film, the scanning spot geometry is the most general for measuring unpolarised transmission of larger film sizes, ie > 15×15 cm. Due to EBT3 film scatter, spot scanning should provide the most accurate profiles of high dose gradients, for a given acceptance angle. The spot scanning densitometer provided useful transmission to ∼5, 25, >25 Gy with 635, 590 and 530 nm light respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wafer integrated micro‐scale concentrating photovoltaics

Abstract A novel micro‐scale photovoltaic concept, Wafer Integrated Micro‐scale Photovoltaics (WPV), is proposed, analyzed, and experimentally demonstrated. The WPV concept seamlessly integrates multijunction micro‐cells with a multi‐functional silicon platform that simultaneously provides optical concentration, hybrid PV/CPV architecture, and mechanical alignment features. Fabrication and optical performance characterization of the Si platform are described in this paper. Over 100% improvement in the concentration‐acceptance‐angle product ( CAP ) is demonstrated using the wafer‐embedded micro‐concentrating elements, leading to significantly reduced module material and fabrication costs, sufficient angular tolerance for low‐cost trackers, and an ultra‐compact optical architecture compatible with commercial flat panel infrastructures. The development of a prototypical module with a 400× concentration ratio is described. Outdoor optical characterization of the module shows acceptance angles of ±1.7° and ±2.5° for 90% of on‐axis power and full‐width‐half‐maximum, respectively. The projected performance of the PV/CPV hybrid architecture illustrates its potential for cost‐effective collection of both direct and diffuse sunlight, thereby extending the geographic and market domains for cost‐effective PV system deployment. Leveraging low‐cost micro‐fabrication and high‐level integration techniques, the WPV approach presents a promising route to combine the high performance of multijunction solar cells and the low costs of flat‐plate Si PV systems.

Li, Duanhui↗

An end of service life assessment of PMMA lenses from veteran concentrator photovoltaic systems

The optical performance of poly(methyl methacrylate) lenses from veteran concentrator photovoltaic modules was examined after the end of their service life. Lenses from the Martin-Marietta and Intersol module designs were examined from the 'Solar Village' site near Riyadh, Saudi Arabia, as well as the Phoenix Sky Harbor airport, followed by the Arizona Public Service Solar Test and Research (APS-STaR) center in Tempe, Arizona. The various lens specimens were deployed for 20, 27, and 22 years, respectively. Optical characterizations included lens efficiency (Solar Simulator instrument), material transmittance and haze (of coupons cut from veteran lenses, then measured again after their faceted back surface was polished, and then measured again after the incident front surface was polished), and direct transmittance (as a function of detector's acceptance angle, using the Very Low Angular Beam Spread ('VLABS') instrument). Lens efficiency measurements compared the central region to the entire lens, also using hot and cold mirror measurements to diagnose differences in performance. A series of subsequent characterizations was performed because a decrease in performance of greater than 10% was observed for some of the veteran lenses. The optimal focal distance of the lenses was quantified using the Solar Simulator, and then correlated to lens curvature using a recently developed measurement technique. Surface roughness was examined using atomic force microscopy and scanning electron microscopy. Facet geometry (tip and valley radius) was quantified on cross-sectioned specimens. As a result, molecular weight was compared between the incident and faceted surfaces of the lenses.

14 SOLAR ENERGY↗

The design of the new IR beamline at ASTRID2

We report on the successful design, installation and commission of the new AU-IR beam line at ASTRID2. ASTRID2 is the new synchrotron facility running at top-up mode and at 580 MeV, which is optimized for low energies at Aarhus University, Denmark. The highlight of the beam line is that it is simple, low cost and reliable. The optics system consists of two gold-coated mirrors only and is as close as 1.367 m away from an entrance edge of a bending magnet. This allows a horizontal acceptance angle of 35 mrad and a vertical acceptance of 28 mrad. The source point is chosen to be near the leading edge of the bending magnet where the electron beam enters the dipole field. This allows us to use the strong edge radiation from the bending magnet together with the bending radiation. The beam line is equipped with a Vertex{sup TM} 70v FTIR spectrometer from Bruker{sup TM}. The beam line design and choice of the “rock-solid” optical design version of spectrometer ensure a good reliability to beam drift and vibrations. Currently, the system is running at mid-range IR. Further upgrades have been planned.

43 PARTICLE ACCELERATORS↗

A Study of the Aligned-Grid Retarding Potential Analyzer for Electric Propulsion Applications

During the development of energy analyzers for NASA’s Solar Electric Propulsion Plasma Diagnostics Package, detailed studies were performed to compare the benefits and drawbacks of different types of gridded potential analyzers. In particular, modeling and testing were performed on three types of retarding potential analyzer with aligned grids, and one type with unaligned grids. Additionally, a type of gridded energy analyzer was tested. Analyses of the model and test results showed that manufacturing an analyzer with aligned grids required greater precision and knowledge than other analyzers. A properly designed analyzer with aligned grids exhibited superior signal level, acceptance angle control, energy resolution, and compactness compared to an analyzer with unaligned grids. Additionally, the gridded energy analyzer was found to accept a broad range of incidence angles while having superior signal, energy resolution, and compactness compared to retarding potential analyzer with unaligned grid. This article describes the basic design principles deployed in the study, the associated modeling work, and the characterization tests that were performed. The article summarizes the benefits and drawbacks associated with each type of energy analyzer tested.

Electric Propulsion↗

Angular and Energy Dependence of Proton Upset in Optocouplers

Proton upset effects in optocouplers were reported by LaBel, et al. that showed an unexpected increase in cross section for incident angles above 80 degrees. Although it appeared that the angular dependence was related to direct ionization from protons, the angular dependence was weaker than expected from basic geometrical arguments using a shallow charge collection depth. Later work showed that the angular dependence of proton upset observed in the earlier studies at a single energy could be explained by considering the distribution of proton recoil energies along with the assumption of a deeper charge collection depth, which was consistent with upset tests from heavy ions. However, an experimental test of the underlying assumptions in the latter work has yet to be done. Protons in space not only arrive over a wide range of incident angles, but also involve a distribution of proton energies. It is necessary to understand both the angular dependence and the dependence of proton upset on energy in order to determine how optocouplers will respond in space. If the angular dependence only occurs for extreme angles of incidence, it will have little impact on the overall cross section because of the narrow acceptance angle. The present work examines mechanisms for proton upset in optocouplers in more detail, investigating the energy dependence and the effects of different load conditions. A model for proton upset is developed, along with a laboratory screening method to determine whether direct ionization is significant for specific device types.

Johnston, A. H.↗

Collimating Montel mirror as part of a multi-crystal analyzer system for resonant inelastic X-ray scattering

Advances in resonant inelastic X-ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L 3 -edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid-angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L 3 -absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X-ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27-ID at the Advanced Photon Source. X-rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X-ray measurements, ray-tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high-resolution RIXS multi-crystal analyzer system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of beam focusing on the efficiency of planar waveguide grating couplers

Results of a theoretical and experimental study into the variation of coupling efficiency with a grating angle are presented for various beam focusing conditions for an integrated optical grating coupler. The study shows that the acceptance angle of the grating coupler can be broadened within a relatively large range and with a relatively small loss of coupling efficiency, by focusing the incident laser beam.

Li, Lifeng↗

Asymmetric-cut variable-incident-angle monochromator

A novel asymmetric-cut variable-incident-angle monochromator was constructed and tested in 1997 at the Advanced Photon Source of Argonne National Laboratory. The monochromator was originally designed as a high heat load monochromator capable of handling 5-10 kW beams from a wiggler source. This was accomplished by spreading the x-ray beam out on the surface an asymmetric-cut crystal and by using liquid metal cooling of the first crystal. The monochromator turned out to be a highly versatile monochromator that could perform many different types of experiments. The monochromator consisted of two 18 deg. asymmetrically cut Si crystals that could be rotated about 3 independent axes. The first stage ({Phi}) rotates the crystal around an axis perpendicular to the diffraction plane. This rotation changes the angle of the incident beam with the surface of the crystal without changing the Bragg angle. The second rotation ({Psi}) is perpendicular to the first and is used to control the shape of the beam footprint on the crystal. The third rotation ({Theta}) controls the Bragg angle. Besides the high heat load application, the use of asymmetrically cut crystals allows one to increase or decrease the acceptance angle for crystal diffraction of a monochromatic x-ray beam and allows one to increase or decrease the wavelength bandwidth of the diffraction of a continuum source like a bending-magnet beam or a normal x-ray-tube source. When the monochromator is used in the doubly expanding mode, it is possible to expand the vertical size of the double-diffracted beam by a factor of 10-15. When this was combined with a bending magnet source, it was possible to generate an 8 keV area beam, 16 mm wide by 26 mm high with a uniform intensity and parallel to 1.2 arc sec that could be applied in imaging experiments.

43 PARTICLE ACCELERATORS↗

The Detector Design of the Jefferson Lab EIC

The Electron-Ion Collider (EIC) is envisioned as the next-generation U.S. facility to study quarks and gluons in strongly interacting matter. The broad physics program of the EIC aims to precisely image gluons in nucleons and nuclei and to reveal the origin of the nucleon spin by colliding polarized electrons with polarized protons, polarized light ions, and heavy nuclei at high luminosity. The Jefferson Lab EIC (JLEIC) design is based on a figure-8 shaped ring-ring collider. The luminosity, exceeding 1033cm -2 s -1 in a broad range of the center-of-mass energy and maximum luminosity above 1034cm -2 s -1 , is achieved by high-rate collisions of short small-emittance low-charge bunches made possible by high-energy electron cooling of the ion beam and synchrotron radiation damping of the electron beam. The polarization of light ion species (p, d, 3He) can be easily preserved and manipulated due to the unique figure-8 shape of the collider rings. The focus of this presentation is put on the JLEIC primary detector that has been designed to support the full physics program of the EIC and to provide essentially full acceptance to all fragments produced in collisions. The detector has been fully integrated with the accelerator and extended to the forward electron and hadron regions to achieve exceptional small-angle acceptance and resolution as well as high-precision electron polarimetry and low-Q 2 tagging. The Central Detector design allows for excellent tracking up to small angles and excellent hadron PID resulting and offers a great performance, in particular for semi-inclusive and exclusive measurements. The combination of high luminosity, highly polarized lepton and ion beams, and a full acceptance, multi-purpose detector fully integrated with the accelerator will allow JLEIC a unique opportunity to make breakthroughs in the investigation of the strong interaction.

43 PARTICLE ACCELERATORS↗

Structural anomalies in undoped Gallium Arsenide observed in high resolution diffraction imaging with monochromatic synchrotron radiation

Novel, streak-like disruption features restricted to the plane of diffraction have recently been observed in images obtained by synchrotron radiation diffraction from undoped, semi-insulating gallium arsenide crystals. These features were identified as ensembles of very thin platelets or interfaces lying in (110) planes, and a structural model consisting of antiphase domain boundaries was proposed. We report here the other principal features observed in high resolution monochromatic synchrotron radiation diffraction images: (quasi) cellular structure; linear, very low-angle subgrain boundaries in (110) directions, and surface stripes in a (110) direction. In addition, we report systematic differences in the acceptance angle for images involving various diffraction vectors. When these observations are considered together, a unifying picture emerges. The presence of ensembles of thin (110) antiphase platelet regions or boundaries is generally consistent not only with the streak-like diffraction features but with the other features reported here as well. For the formation of such regions we propose two mechanisms, operating in parallel, that appear to be consistent with the various defect features observed by a variety of techniques.

Steiner, B.↗

Structural anomalies in undoped gallium arsenide observed in high-resolution diffraction imaging with monochromatic synchrotron radiation

Novel, streak-like disruption features restricted to the plane of diffraction have recently been observed in images obtained by synchrotron radiation diffraction from undoped, semi-insulating gallium arsenide crystals. These features were identified as ensembles of very thin platelets or interfaces lying in (110) planes, and a structural model consisting of antiphase domain boundaries was proposed. We report here the other principal features observed in high resolution monochromatic synchrotron radiation diffraction images: (quasi) cellular structure; linear, very low-angle subgrain boundaries in (110) directions, and surface stripes in a (110) direction. In addition, we report systematic differences in the acceptance angle for images involving various diffraction vectors. When these observations are considered together, a unifying picture emerges. The presence of ensembles of thin (110) antiphase platelet regions or boundaries is generally consistent not only with the streak-like diffraction features but with the other features reported here as well. For the formation of such regions we propose two mechanisms, operating in parallel, that appear to be consistent with the various defect features observed by a variety of techniques.

Steiner, B.↗

Atomic-resolution defect contrast in low angle annular dark-field STEM

While traditional high-resolution STEM is performed by exclusively collecting electrons which have been scattered to high angles (i.e., HAADF), the present contribution will focus on small-angle scattered electrons, as in low angle annular dark-field (LAADF) STEM. This unique imaging mode allows one to image defect contrast while maintaining directly interpretable atomic resolution. By simply adjusting the microscope camera length, and thus the acceptance angle of the annular detector, it is possible to transition between Z-contrast and defect contrast. Both LAADF and HAADF experimental and computational results are discussed in regards to zone axis imaging of a y/y1Ni-superalloy; various length scales are explored. Electron de-channeling is observed while the probe is placed over defected regions of crystal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of imaging properties for submillimeter rectangular pinholes

Purpose: Recently, a multipinhole collimator with inserts that have both rectangular apertures and rectangular fields of view (FOVs) has been proposed for SPECT imaging since it can tile the projection onto the detector efficiently and the FOVs in transverse and axial directions become separable. The purpose of this study is to investigate the image properties of rectangular-aperture pinholes with submillimeter apertures sizes. Methods: In this work, the authors have conducted sensitivity and FOV experiments for 18 replicates of a prototype insert fabricated in platinum/iridium (Pt/Ir) alloy with submillimeter square-apertures. A sin{sup q}θ fit to the experimental sensitivity has been performed for these inserts. For the FOV measurement, the authors have proposed a new formula to calculate the projection intensity of a flood image on the detector, taking into account the penumbra effect. By fitting this formula to the measured projection data, the authors obtained the acceptance angles. Results: The mean (standard deviation) of fitted sensitivity exponents q and effective edge lengths w{sub e} were, respectively, 10.8 (1.8) and 0.38 mm (0.02 mm), which were close to the values, 7.84 and 0.396 mm, obtained from Monte Carlo calculations using the parameters of the designed inserts. For the FOV measurement, the mean (standard deviation) of the transverse and axial acceptances were 35.0° (1.2°) and 30.5° (1.6°), which are in good agreement with the designed values (34.3° and 29.9°). Conclusions: These results showed that the physical properties of the fabricated inserts with submillimeter aperture size matched our design well.

60 APPLIED LIFE SCIENCES↗

Ion energy distribution near a plasma meniscus with beam extraction for multi element focused ion beams

An earlier study of the axial ion energy distribution in the extraction region (plasma meniscus) of a compact microwave plasma ion source showed that the axial ion energy spread near the meniscus is small ({approx}5 eV) and comparable to that of a liquid metal ion source, making it a promising candidate for focused ion beam (FIB) applications [J. V. Mathew and S. Bhattacharjee, J. Appl. Phys. 105, 96101 (2009)]. In the present work we have investigated the radial ion energy distribution (IED) under the influence of beam extraction. Initially a single Einzel lens system has been used for beam extraction with potentials up to -6 kV for obtaining parallel beams. In situ measurements of IED with extraction voltages upto -5 kV indicates that beam extraction has a weak influence on the energy spread ({+-}0.5 eV) which is of significance from the point of view of FIB applications. It is found that by reducing the geometrical acceptance angle at the ion energy analyzer probe, close to unidirectional distribution can be obtained with a spread that is smaller by at least 1 eV.

43 PARTICLE ACCELERATORS↗

Measurement of absolute charge-exchange cross sections for He{sup 2+} collisions with He and H{sub 2}

Reported are total, absolute charge-exchange cross sections for collisions of {sup 3}He{sup 2+} ions with He and H{sub 2}. Measurements are reported at fixed energies between 0.33 and 4.67 keV/amu. Both the present results and earlier results of others are analyzed in terms of available experimental small-angle differential cross sections as a function of collision energy, and hence the geometry of the exit aperture of the gas-collision cells used by the various experimental groups. In addition, the effective length of gas-collision cells is studied using fluid dynamic and molecular flow simulations to address the density patterns near the cell entrance and exit apertures. When small acceptance-angle corrections were applied, the results of present and previous measurements for the single electron capture in these systems were brought into good accord in the relevant energy ranges. Taken in their entirety, the present data for {sup 3}He{sup 2+} with He and H{sub 2} lend themselves to new theoretical calculations of the multichannel charge-exchange cross sections.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray beam transfer between hollow fibers for long-distance transport

Fiber optics for controlling the x-ray beam trajectory has been examined at the synchrotron facility of SPring-8. Up to now, we have achieved beam deflection by several tens of milli-radian and axis shift of around 75 mm with a 1.5 m-long flexible hollow glass capillary. The achievable beam deflecting angle, axis shift, and timing delay are, in principle, proportional to the length, the square of length and the cube of length, respectively. Thus, for further applications, requiring larger beam shift and pulse delay, longer fibers are indispensable. In order to achieve long-distance transport using the fiber, we thus examined the connection transferring x-rays between fibers in an experimental hutch. The acceptance angle at the input end and the throughput efficiency of the second fiber is consistent with the consideration of the output beam divergence of the first fiber. The enhancement of the transfer efficiency is also discussed for the cases of a closer joint and the use of a refractive lens as a coupler.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗