Search NASA⌕ Search

SEARCH · Search NASA

Results for “actual”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Permanganate Oxidation of Actual Defense Waste Processing Facility (DWPF) Slurry Mix Evaporator Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) Samples to Remediate Glycolate

Savannah River Remediation (SRR) tasked Savannah River National Laboratory (SRNL) to examine glycolate destruction in radioactive samples emulating the proposed process. Experiments with radioactive Defense Waste Processing Facility (DWPF) condensates were performed to demonstrate the oxidation of glycolate using sodium permanganate. One test each was performed for Off-Gas Condensate Tank (OGCT) and Slurry Mix Evaporator Condensate Tank (SMECT) samples received. Condensates were blended with Recycle Collection Tank (RCT) heel simulant and Slurry Mix Evaporator (SME) product containing glycolate to represent typical RCT compositions with estimated nominal entrainment of glycolate. A permanganate to glycolate (P/G) molar ratio targeting 5.7 decreased sample glycolate concentration below Ion Chromatography (IC), glycolate method reporting limits in less than 2 hours for the OGCT sample and in less than 8 hours for the SMECT sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bell’s Dodecants: An Architecture for How Technoscience Actually Advances

In this talk, we discuss an architecture for what technoscience is and how it advances. We call our architecture “Bell’s Dodecants.” The name follows from its six mechanisms and two flavors for how technoscience advances, with Alexander Graham Bell an exemplar of a perspective, embodied in Bell Labs, of the balanced nurturing of all six mechanisms and two flavors.

Tsao, Jeffrey Y.↗

Actualizing Change after Experiencing Significant Mathematics PD: Hearing from Teachers of Color about Their Practice and Mathematical Identities

While it is well-documented that students of color and students from low-income communities have often been denied access to a challenging education in mathematics in the United States, less is known about how teachers of color have overcome their deprived educational backgrounds to become teachers of mathematics who implement inquiry-based instructional methods as a means to improve their students’ learning and mathematical identities. In this article, we use a sociopolitical theoretical framework to examine how seven elementary school teachers of color characterized their experiences as mathematics students, themselves as teachers of mathematics, and their mathematical identities after experiencing significant professional development in mathematics. All the participants in this study had experienced extensive professional development support in mathematics over a sustained period of time. We demonstrate through the teachers’ narratives that, given the deprived mathematics education that the majority of the participants experienced as PK-12 students, having opportunities to participate in significant and focused PD in mathematics over a sustained period transformed how teachers viewed themselves as teachers and positively impacted their mathematical identities.

99 GENERAL AND MISCELLANEOUS↗

Operational-based annual energy production uncertainty: are its components actually uncorrelated?

Calculations of annual energy production (AEP) from a wind power plant – whether based on preconstruction or operational data – are critical for wind plant financial transactions. The uncertainty in the AEP calculation is especially important in quantifying risk and is a key factor in determining financing terms. A popular industry practice is to assume that different uncertainty components within an AEP calculation are uncorrelated and can therefore be combined as the sum of their squares. We assess the practical validity of this assumption for operational-based uncertainty by performing operational AEP estimates for more than 470 wind plants in the United States, mostly in simple terrain. We apply a Monte Carlo approach to quantify uncertainty in five categories: revenue meter data, wind speed data, regression relationship between density-corrected wind speed (from reanalysis data) and measured wind power, length of long-term-correction data set, and future interannual variability. We identify correlations between categories by comparing the results across all 470 wind plants. We observe a positive correlation between interannual variability and the linearized long-term correction; a negative correlation between wind resource interannual variability and linear regression; and a positive correlation between reference wind speed uncertainty and linear regression. Then, we contrast total operational AEP uncertainty values calculated by omitting and considering correlations between the uncertainty components. We quantify that ignoring these correlations leads to an underestimation of total AEP uncertainty of, on average, 0.1% and as large as 0.5% for specific sites. Although these are not large increases, these would still impact wind plant financing rates; further, we expect these values to increase for wind plants in complex terrain. Based on these results, we conclude that correlations between the identified uncertainty components should be considered when computing the total AEP uncertainty.

17 WIND ENERGY↗

Progressive collapse analysis of stiffened panel structure with consideration of actual welding distortion and residual stresses

To date, inclusion of welding distortion and residual stresses in determining the strength of marine structures is based on empirical formulations due to welding complexity. In this study, a more feasible numerical model was developed from the perspective of inherent strain theory. The accuracy of this simplified numerical model was confirmed by transient thermo-elastic–plastic finite element analysis using a novel dynamic mesh refining and iterative substructure method which is 50 times faster than conventional finite element method. Welding distortion by the two numerical approaches was validated with experimental measurement. The collapse analyses indicated that the inherent strain model predicted a compressive strength and load-displacement curve with high accuracy, as validated by the transient thermo-mechanical model. The global stiffness and the ultimate strength of the welded structure would be overestimated by about 22% if no welding effects were considered. The proposed computation procedure for determining the ultimate strength of welded structures is accurate, simple, and practical and enables improvement of ultimate strength through optimization of welding joint design to reduce the welding residual stress and distortion.

Huang, Hui↗

Filter 'Cook-Off': Filter Selection via Side-by-Side Testing at Actual Process Conditions - 20040

In 2005, the THOR steam reforming fluidized-bed reactor technology was selected by the U.S. Department of Energy for treatment of sodium-bearing waste at the INL. During the final phase of commissioning prior to radiological operations, regeneration of the high temperature filters in the process gas filter (PGF) vessel became ineffective. After approximately 50 days of testing, the differential pressure across the filters began increasing exponentially and the plant had to be shutdown. Subsequent investigation revealed that the Inconel 625 (I625) sintered metal filter media was corroding in the 550 deg. C reducing environment. A pilot plant run tested four candidate replacement filter media. The top candidate was further tested during a long-term pilot plant run to validate the selection. Data from the testing indicate the selected filters will provide reliable service throughout the life of the project, including after in-situ radiological decontamination. This paper presents the data from this effort and reinforces the value of pilot plant testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Empirical Study on the Use of the Rancor Microworld Simulator to Support Full-scope Data Collection

A lack of data has been identified as a major challenge in human reliability analysis (HRA). Accordingly, several institutes and researchers have tried to collect HRA data from different data sources such as actual historical measurements, expert judgements, or simulator studies. While the most recent studies predominantly focus on collecting data using full-scope simulators with actual operators, Idaho National Laboratory (INL) has begun to collect HRA data using a simplified simulator, i.e., the Rancor Microworld simulator, with student participants. Full-scope studies have been known to have several intrinsic challenges to securing enough quantity of the data due to many reasons like the high cost for performing experiments or requiring actual operators’ cooperation. The ultimate goal of INL’s effort aims to infer actual operators’ data collected from a full-scope simulator on the basis of microworld data with student subjects as well as collect additional data that could be missed in the full-scope research. As a first step to achieve this goal, this paper projects an experimental plan for investigating the differences in human performance between individuals in two groups: 1) an actual operator and 2) a student when using the Rancor Microworld simulator. A randomized factorial experiment design has been developed with two independent variables, i.e., type of scenario and type of subject. Six human performance measures, i.e., 1) time, 2) error, 3) workload, 4) situation awareness, 5) patterns of attention and 6) the number of manipulations were selected. A couple of scenarios and their procedures available to the Rancor Microworld simulator have been developed.

99 GENERAL AND MISCELLANEOUS↗

CO 2 plume evolution in a depleted natural gas reservoir: Modeling of conformance uncertainty reduction over time

Uncertainty in the long-term fate of CO 2 injected for geologic carbon sequestration (GCS) is a significant barrier to the adoption of GCS as a greenhouse-gas emission-mitigation for industry and regulatory agencies alike. Here, we present a modeling study that demonstrates that the uncertainty in forecasts of GCS site performance decreases over time as monitoring data are used to update operational models. We consider a case study of GCS in a depleted natural gas reservoir, with CO 2 injection occurring over 20 years, with a 50-year post-injection site care period. We constructed a detailed model to generate the actual model output, which is considered synthetic observation data. A series of simpler operational models based on limited data and assumptions about how an operator would model such a site are then run and compared against actual model output at specific monitoring points after one year, two years, etc. The operational model is updated and improved using the synthetic observation data from the actual model at the same time intervals. Model parameter values and model features needed to be updated over time to improve matches to the actual model. These kinds of model adjustments would be a normal part of reservoir engineering and site management at GCS sites. Uncertainty in two key measures related to site performance decreases with time: extent of the CO 2 plume up-dip migration, and radial extent of the pressure pulse. This conclusion should help allay the concerns of industry and regulators about uncertainty in long-term fate of CO 2 at GCS sites.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the driving factors of CO 2 mitigation costs of household biogas systems in China: A LMDI decomposition with cost analysis model

China has been placing a substantial focus on biogas for reducing energy consumption and carbon dioxide (CO 2 ) emissions. The operation mode of biogas systems may make the CO 2 reduction target over-optimistic. There is limited research to investigate the influential factors that may be causing the gap between the actual and theoretical CO 2 reduction costs of biogas systems in China. In this research, by using field survey data of 209 biogas users and 489 non-biogas users from 19 villages in 2015, the gap between actual and theoretical unit CO 2 reduction cost is quantified at approximately 156 USD/t CO 2 . By employing the Logarithmic Mean Divisia Index I (LMDI) model, it is found that both the cost effect (48%) and the reduction effect (52%) contribute to the unit CO 2 reduction cost gap. Furthermore, four influential factors–household labor, accessibility to the energy resource, acceptance of biogas technology, and subsidy–significantly narrow the gap between actual and theoretical CO 2 reduction costs, while the levelized subsidy contributes to widening the gap. On average, biogas systems should be operated for at least four years and the substitution rate should be more than 67% in order to keep the gap between actual and theoretical CO 2 reduction costs under 50%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Identification and Quantification of Technetium Species in Hanford Waste Tank AN-102

Technetium-99 (Tc) generated from the fission of 235U and 239Pu in high yields is one of the most difficult contaminants to be addressed at the U.S. Department of Energy Hanford Site. In strongly alkaline solutions typifying Hanford tank waste, Tc exists as pertechnetate (TcO4-) (oxidation state VII) as well as in reduced forms (oxidation state < VII) collectively known as non-pertechnetate species. Designing strategies for effective Tc management, including separation and immobilization, necessitates understanding the molecular structure of the non- pertechnetate species and their identification in the actual tank waste samples, which would facilitate development of new treatment technologies effective for dissimilar Tc species. Toward this objective, a spectroscopic library of the Tc(I) [fac-Tc(CO)3]+ and Tc(IV, VII) compounds was generated using a range of techniques and applied to the characterization of the actual tank waste supernatant collected from the tank 241-AN-102 at Hanford, WA. A sample of the 241-AN-102 tank waste supernatant was processed to adjust Na concentration to about 5.6 M and remove 137Cs by spherical resorcinol-formaldehyde (sRF) ion exchange resin. Cesium-loaded sRF column was eluted with 0.5 M HNO3. As received AN-102, Cs-depleted AN-102 effluent, and sRF eluate fractions were comprehensively characterized for chemical composition and speciation of Tc using 99Tc nuclear magnetic resonance spectroscopy and X-ray absorption spectroscopy. It was demonstrated for the first time that non-pertechnetate Tc present in the 241-AN-102 tank waste is composed of several low-valent Tc species, including the Tc(I) [fac-Tc(CO)3]+ and Tc(IV) compounds. This is the second experimental observation of the [fac-Tc(CO)3]+ species in the Hanford tank waste and the first demonstration of multiple forms of non-pertechnetate species existing simultaneously in the waste, cumulatively highlighting their importance for the waste processing.

Low Activity Waste (LAW), High Level Waste, nuclea↗

A Novel Spatial-Temporal Variational Quantum Circuit to Enable Deep Learning on NISQ Devices

Quantum computing presents a promising approach for machine learning with its capability for extremely parallel computation in high-dimension through superposition and entanglement. Despite its potential, existing quantum learning algorithms, such as Variational Quantum Circuits (VQCs), face challenges in handling more complex datasets, particularly those that are not linearly separable. What’s more, it encounters the deployability issue, making the learning models suffer a drastic accuracy drop after deploying them to the actual quantum devices. To overcome these limitations, this paper proposes a novel spatial-temporal design, namely “ST-VQC”, to integrate nonlinearity in quantum learning and improve the robustness of the learning model to noise. Specifically, ST-VQC can extract spatial features via a novel block-based encoding quantum sub-circuit coupled with a layer-wise computation quantum sub-circuit to enable temporal-wise deep learning. Additionally, a SWAP-Free physical circuit design is devised to improve robustness. These designs bring a number of hyperparameters. After a systematic analysis of the design space for each design component, an automated optimization framework is proposed to generate the ST-VQC quantum circuit. The proposed ST-VQC has been evaluated on two IBM quantum processors, ibm-cairo with 27 qubits and ibmq-lima with 7 qubits to assess its effectiveness. The results of the evaluation on the standard dataset for binary classification show that ST-VQC can achieve over 30% accuracy improvement compared with existing VQCs on actual quantum computers. Moreover, on a non-linear synthetic dataset, the STVQC outperforms a linear classifier by 27.9%, while the linear classifier using classical computing outperforms the existing VQC by 15.58%.

Li, Jinyang↗

Economic, Exergy, and Environmental Analyses of the Energy Assessments for U.S. Industries

Abstract This paper highlights the expected versus actual outcomes of 152 energy assessments that were performed between 2011 and 2020. The 1317 energy-assessment recommendations (ARs) are grouped into eight categories. This study adopted four measures per each category of recommendations: annual electricity savings, annual gas savings, annual cost savings, and annual CO2 emission reduction. The first part of the analysis compares the expected to the actually implemented values of the measures applied to each recommendation’s category. It was found that the percentages of the actual to the expected electricity, gas, and cost savings are 26.6%, 11.4%, and 17.1%, respectively, while the percentage of the actual to the expected CO2 reduction is 22%. Moreover, the second part of the analysis presents each category's implementation rate and the reasons for rejecting the unimplemented ARs. Cash flow and expensive initial investment resulted in rejecting 25% of ARs. Furthermore, the study proposes techniques and strategies to increase ARs’ implementation rate and improve private energy services companies’ implementation rate. Finally, exergy analysis is added to show the improvement that energy assessment achieves regarding exergy and exergy efficiencies of different industrial applications.

Energy & Fuels↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗