Search NASA⌕ Search

SEARCH · Search NASA

Results for “adherend”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Preliminary design of cracked-lap shear specimen thickness for determination of interlaminar fracture toughness

This paper outlines a technique for preliminary sizing of the adherends for cracked-lap-shear specimen to assure delamination instead of adherend failure. The cracked-lap-shear specimen is a popular specimen used for determination of mixed mode interlaminar fracture toughness of composites. Thin adherends, on the order of three plies thick, have been used successfully in the past for determination of fracture toughness of rather brittle matrix systems. However, the tougher matrices now being considered for composite applications require thicker adherends in order to get composite delamination rather than adherend failure. The optimum thickness is obtained on the basis that the critical value of the strain energy release rate is reached at the delamination front before the ultimate strength is reached in the adherend. By proper design the specimen would delaminate and not use excessive material or load. A simple analysis for the optimum adherend thickness and experimental verification are included.

Mangalgiri, P. D.↗

Influence of interface ply orientation on fatigue damage of adhesively bonded composite joints

An experimental study of cracked-lap-shear specimens was conducted to determine the influence of adherend stacking sequence on debond initiation and damage growth in a composite-to-composite bonded joint. Specimens consisted of quasi-isotropic graphite/epoxy adherends bonded together with either FM-300 or EC 3445 adhesives. The stacking sequence of the adherends was varied such that 0 deg, 45 deg, or 90 deg plies were present at the adherend-adhesive interfaces. Fatigue damage initiated in the adhesive layer in those specimens with 0 deg nd 45 deg interface plies. Damage initiated in the form of ply cracking in the strap adherend for the specimens with 90 deg interface plies. The fatigue-damage growth was in the form of delamination within the composite adherends for specimens with the 90 deg and 45 deg plies next to the adhesive, while debonding in the adhesive resulted for the specimens with 0 deg plies next to the adhesive. Those joints with the 0 deg and 45 deg plies next to either adhesive has essentially the same fatigue-damage-initiation stress levels. These stress levels were 13 and 71 percent higher, respectively, than those for specimens with 90 deg plies next to the EC 3445 and FM-300 adhesives.

Johnson, W. S.↗

Cyclic debonding of adhesively bonded composites

To analyze the fatigue behavior of a simple composite-to-composite bonded joint, a combined experimental and analytical study of the cracked-lap-shear specimen subjected to constant-amplitude cyclic loading was undertaken. Two bonded systems were studied: T300/5208 graphite/epoxy adherends bonded with adhesives EC 3445 and with FM-300. For each bonded system, two specimen geometries were tested: (1) a strap adherend of 16 plies bonded to a lap adherend of 8 plies, and (2) a strap adherend of 8 plies bonded to a lap adherend of 16 plies. In all specimens tested, the fatigue failure was in the form of cyclic debonding with some 0 deg fiber pull-off from the strap adherend. The debond always grew in the region of adhesive that had the highest mode I (peel) loading and that region was close to the adhesive-strap interface. Furthermore, the measured cyclic debond growth rates correlated well with total strain energy release rates G(T) as well as with its components G(I) (peel) and G(II) (shear) for the mixed-mode loading in the present study.

Mall, S.↗

Influence of interface ply orientation on fatigue damage of adhesively bonded composite joints

An experimental study of cracked-lap-shear specimens was conducted to determine the influence of adherend stacking sequence on debond initiation and damage growth in a composite-to-composite bonded joint. Specimens consisted of quasi-isotropic graphite/epoxy adherends bonded together with either FM-300 or EC 3445 adhesives. The stacking sequence of the adherends was varied such that 0 deg, 45 deg, or 90 deg plies were present at the adherend-adhesive interfaces. Fatigue damage initiated in the adhesive layer in those specimens with 0 deg and 45 deg interface plies. Damaage initiated in the form of ply cracking in the strap adherend for the specimens with 90 deg interface plies. The fatigue-damage growth was in the form of delamination within the composite adherends for specimens with the 90 deg and 45 deg plies next to the adhesive, while debonding in the adhesive resulted for the specimens with 0 deg plies next to the adhesive. Those joints with the 0 deg and 45 deg plies next to either adhesive has essentially the same fatigue-damage-initiation stress levels. These stress levels were 13 and 71 percent higher, respectively, than those for specimens with 90 deg plies next to the EC 3445 and FM-300 adhesives.

Johnson, W. S.↗

Test and analysis of Celion 3000/PMR-15, graphite/polyimide bonded composite joints: Data report

Standard single lap, double lap and symmetric step lap bonded joints of Celion 3000/PMR-15 graphite/polyimide composite were evaluated. Composite to composite and composite to titanium joints were tested at 116 K (-250 F), 294 K (70 F) and 561 K (550 F). Joint parameters evaluated are lap length, adherend thickness, adherend axial stiffness, lamina stacking sequence and adherend tapering. Advanced joint concepts were examined to establish the change in performance of preformed adherends, scalloped adherends and hybrid systems. The material properties of the high temperature adhesive, designated A7F, used for bonding were established. The bonded joint tests resulted in interlaminar shear or peel failures of the composite and there were very few adhesive failures. Average test results agree with expected performance trends for the various test parameters. Results of finite element analyses and of test/analysis correlations are also presented.

Cushman, J. B.↗

Cyclic debonding of adhesively bonded composites

The fatigue behavior of a simple composite to composite bonded joint was analyzed. The cracked lap shear specimen subjected to constant amplitude cyclic loading was studied. Two specimen geometries were tested for each bonded system: (1) a strap adherend of 16 plies bonded to a lap adherend of 8 plies; and (2) a strap adherend of 8 plies bonded to a lap adherend of 16 plies. In all specimens the fatigue failure was in the form of cyclic debonding with some 0 deg fiber pull off from the strap adherend. The debond always grew in the region of adhesive that had the highest mode (peel) loading and that region was close to the adhesive strap interface.

Mall, S.↗

Test and analysis of Celion 3000/PMR-15, graphite/polyimide bonded composite joints: Summary

Standard single lap, double lap and symmetric step lap bonded joints of Celion 3000/PMR-15 graphite/polyimide composite were evaluated. Composite to composite and composite to titanium joints were tested at 116K (-250 F), 294K (70 F) and 561K (550 F). Joint parameters evaluated were lap length, adherend thickness, adherend axial stiffness, lamina stacking sequence and adherend tapering. Tests of advanced joint concepts were also conducted to establish the change in performance of preformed adherends, scalloped adherends and hybrid systems. Special tests were conducted to establish material properties of the high temperature adhesive, designated A7F, used for bonding. Most of the bonded joint tests resulted in interlaminar shear or peel failures of the composite. There were very few adhesive failures. Average test results agree with expected performance trends for the various test parameters. Results of finite element analyses and of test/analysis correlations are also presented.

Cushman, J. B.↗

Debonding characteristics of adhesively bonded woven Kevlar composites

The fatigue damage mechanism of an adhesively bonded joint between fabric reinforced composite adherends was investigated with cracked-lap-shear specimens. Two bonded systems were studied: fabric Kevlar 49/5208 epoxy adherends bonded together with either EC 3445 or FM-300 adhesive. For each bonded system, two specimen geometries were tested. In all specimens tested, fatigue damage occurred in the form of cyclic debonding; however, the woven Kevlar specimens gave significantly slower debond growth rates and higher fracture toughness than previously found in the nonwoven adherend specimens. The surfaces for the woven adherends were not smooth; rather, they had regular crests (high spots) and troughs (low spots) due to the weave pattern. Radiographs of the specimens and examination of their failure surfaces revealed that fiber bridging occurred between the crests of the two adherends in the debonded region. The observed improvements in debond growth resistance and static fracture toughness are attributed to this bridging.

Mall, S.↗

Stresses in adhesively bonded joints: A closed form solution

The plane strain of adhesively bonded structures which consist of two different orthotropic adherents is considered. Assuming that the thicknesses of the adherends are constant and are small in relation to the lateral dimensions of the bonded region, the adherends are treated as plates. The transverse shear effects in the adherends and the in-plane normal strain in the adhesive are taken into account. The problem is reduced to a system of differential equations for the adhesive stresses which is solved in closed form. A single lap joint and a stiffened plate under various loading conditions are considered as examples. To verify the basic trend of the solutions obtained from the plate theory a sample problem is solved by using the finite element method and by treating the adherends and the adhesive as elastic continua. The plate theory not only predicts the correct trend for the adhesive stresses but also gives rather surprisingly accurate results.

Delale, F.↗

Fracture surface analysis in composite and titanium bonding: Part 1: Titanium bonding

Fractured lap shear Ti 6-4 adherends bonded with polyphenyquinoxaline (PPQ) and polysulfone were analyzed. The effects of adherend pretreatment, stress level, thermal aging, anodizing voltage, and modified adhesive of Ti 6-4 adherend bonded with PPQ on lap shear strength were studied. The effect of adherend pretreatment on lap shear strength was investigated for PS samples. Results of scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) used to study the surface topography and surface composition are also discussed.

Sanderson, K. A.↗

End effects in scarf joints

Scarf joints with small scarf angles are especially sensitive to stiffness mismatch between adherends and to adherend tip bluntness. Pre-assembly breakage of an adherend tip where it is only a few microns thick can cause significant reduction in joint strength. Mathematically, the reason for such sensitivity is that the solutions to the governing differential equation develop boundary layer character when the scarf angles are small. The boundary layers are regions with large adhesive stresses. Experimental strength data for laminated composite adherends agree with the results of this analysis.

Adkins, D. W.↗

Interpreting test temperature and loading rate effects on the fracture toughness of polymer-metal interfaces via time–temperature superposition

Here, in this letter, we present interfacial fracture toughness data for a polymer-metal interface where tests were conducted at various test temperatures T and loading rates $\dot{δ}$. An adhesively bonded asymmetric double cantilever beam (ADCB) specimen was utilized to measure toughness. ADCB specimens were created by bonding a thinner, upper adherend to a thicker, lower adherend (both 6061 T6 aluminum) using a thin layer of epoxy adhesive, such that the crack propagated along the interface between the thinner adherend and the epoxy layer. The specimens were tested at T from 25 to 65 °C and $\dot{δ}$ from 0.002 to 0.2 mm/s. The measured interfacial toughness Γ increased as both T and $\dot{δ}$ increased. For an ADCB specimen loaded at a constant $\dot{δ}$, the energy release rate G increases as the crack length a increases. For this reason, we defined rate effects in terms of the rate of change in the energy release rate $\dot{G}$. Although not rigorously correct, a formal application of time–temperature superposition (TTS) analysis to the Γ data provided useful insights on the observed dependencies. In the TTS-shifted data, Γ decreased and then increased for monotonically increasing $\dot{G}$. Thus, the TTS analysis suggests that there is a minimum value of Γ. This minimum value could be used to define a lower bound in Γ when designing critical engineering applications that are subjected to T and $\dot{δ}$ excursions.

36 MATERIALS SCIENCE↗

Exploring Failure of Adhesively-Bonded Joints with Different Void Sizes at the Same Void Volume Fraction through A Micro-scale Numerical Modeling

This paper studied the effects of void sizes on the failure behavior of adhesively-bonded materials under global shear via micro-scale computational modeling. The numerical results indicate that large void sizes with increased distances between them at the same void volume fraction can alleviate the reduced joint strength of a weaker adherend-adhesive interface caused by interfacial voids. However, this is not the case for an adherend-adhesive interface with the interfacial tensile strength being sufficiently higher than the adhesive strength, showing the negligible effect on the joint strength due to various void sizes and the amount of interfacial voids. This preliminary investigation provides insightful information for scaling up the void size in the macro-scale computational modeling of joints, and enhances the understanding of the micro-mechanical adhesion in adherend-adhesive interfaces with different levels of bonding.

Qiao, Yao↗

Optimizing Aluminum Bonding: Exploring Surface Roughness and Contact Angle Effects through Plasma and Acid Etching Contrasts

The use of adhesives to replace traditional techniques like welding and riveting has been on the rise in various industries as increasingly complex geometries and situations for bonding is required. It’s well known in the scientific community that an adhesive bond is only as efficient as the surface preparation used beforehand. Plasma treatments have been shown to gently clean the surface by only removing the top-most layer from the adherend and “charging” the surface instead of berating it. Whereas chemical treatments “etch” the surface in hopes of increasing surface area by increasing surface roughness. This method can be difficult to control quantitatively and can generate waste leading to serious environmental concerns. This study aims to address the encountered differences between plasma treatments and acid etching on aluminum substrates for adhesive bonding. Treating the surface of adherends plays a crucial role in promoting a good bond between adhesive and adherend. In this study, the effects of plasma and acid treatments are categorized using surface roughness measurements as well as contact angle which have been shown to correlate to mechanical strength. When evaluating different surface treatments, it is notable to mention that not only surface roughness and contact angle play a role in determining which method is most effective but also the consequences of the treatment itself. It was found that although chemical etching was the most effective in increasing roughness and decreasing contact angle, it generates a large amount of waste and is not sustainable compared to plasma work which uses a renewable process. The results from this work provide a deeper understanding of the relationship between surface treatments and surface roughness/contact angle and how this relates to a stronger adhesive bond.

36 MATERIALS SCIENCE↗

Optimizing Aluminum Bonding: Exploring Surface Roughness and Contact Angle Effects through Plasma and Acid Etching Contrasts.

The use of adhesives to replace traditional techniques like welding and riveting has been on the rise in various industries as increasingly complex geometries and situations for bonding is required. It’s well known in the scientific community that an adhesive bond is only as efficient as the surface preparation used beforehand. Plasma treatments have been shown to gently clean the surface by only removing the top-most layer from the adherend and “charging” the surface instead of berating it. Whereas chemical treatments “etch” the surface in hopes of increasing surface area by increasing surface roughness. This method can be difficult to control quantitatively and can generate waste leading to serious environmental concerns. This study aims to address the encountered differences between plasma treatments and acid etching on aluminum substrates for adhesive bonding. Treating the surface of adherends plays a crucial role in promoting a good bond between adhesive and adherend. In this study, the effects of plasma and acid treatments are categorized using surface roughness measurements as well as contact angle which have been shown to correlate to mechanical strength. When evaluating different surface treatments, it is notable to mention that not only surface roughness and contact angle play a role in determining which method is most effective but also the consequences of the treatment itself. It was found that although chemical etching was the most effective in increasing roughness and decreasing contact angle, it generates a large amount of waste and is not sustainable compared to plasma work which uses a renewable process. The results from this work provide a deeper understanding of the relationship between surface treatments and surface roughness/contact angle and how this relates to a stronger adhesive bond

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adhesive-bonded double-lap joints

Explicit analytical solutions are derived for the static load carrying capacity of double-lap adhesive-bonded joints. The analyses extend the elastic solution Volkersen and cover adhesive plasticity, adherend stiffness imbalance and thermal mismatch between the adherends. Both elastic-plastic and bi-elastic adhesive representations lead to the explicit result that the influence of the adhesive on the maximum potential bond strength is defined uniquely by the strain energy in shear per unit area of bond. Failures induced by peel stresses at the ends of the joint are examined. This failure mode is particularly important for composite adherends. The explicit solutions are sufficiently simple to be used for design purposes

Hart-Smith, L. J.↗

Analysis and design of advanced composite bounded joints

Advances in the analysis of adhesive-bonded joints are presented with particular emphasis on advanced composite structures. The joints analyzed are of double-lap, single-lap, scarf, stepped-lap and tapered-lap configurations. Tensile, compressive, and in-plane shear loads are covered. In addition to the usual geometric variables, the theory accounts for the strength increases attributable to adhesive plasticity (in terms of the elastic-plastic adhesive model) and the joint strength reductions imposed by imbalances between the adherends. The solutions are largely closed-form analytical results, employing iterative solutions on a digital computer for the more complicated joint configurations. In assessing the joint efficiency, three potential failure modes are considered. These are adherend failure outside the joint, adhesive failure in shear, and adherend interlaminar tension failure (or adhesive failure in peel). Each mode is governed by a distinct mathematical analysis and each prevails throughout different ranges of geometric sizes and proportions.

Hart-Smith, L. J.↗

An investigation of adhesive/adherend and fiber/matrix interactions. Part B: SEM/ESCA analysis of fracture surfaces

Adhesion was studied with emphasis on the characterization of surface oxide layers, the analysis of fracture surfaces, and the interaction of matrices and fibers. A number of surface features of the fractured lap shear samples were noted in the SEM photomicrographs including the beta phase alloy of the Ti 6-4 adherend, the imprint of the adherend on the adhesive failure surface, increased void density for high temperature samples, and the alumina filler particles. Interfacial failure of some of the fractured lap shear samples is invariably characterized by the appearance of an ESCA oxygen photopeak at 530.3 eV assigned to the surface oxide layer of Ti 6-4 adherend. The effect of grit blasting on carbon fiber composites is evident in the SEM analysis. A high surface fluorine concentration on the composite surface is reduced some ten fold by grit blasting.

Beck, B.↗