Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Testing of a Miniature Loop Heat Pipe Using a Thermal Electrical Cooler for Temperature Control

This paper describes the design and testing of a miniature LHP having a 7 mm O.D. evaporator with an integral CC. The vapor line and liquid line are made of 1.6mm stainless steel tubing. The evaporator and the CC are connected on the outer surface by a copper strap and a thermoelectric (TEC) is installed on the strap. The TEC is used to control the CC temperature by applying an electrical current for heating or cooling. Tests performed in ambient included start-up, power cycle, sink temperature cycle, and CC temperature control using TEC. The LHP demonstrated very robust operation in all tests where the heat load varied between 0.5W and 1OOW, and the sink temperature varied between 243K and 293K. The heat leak from the evaporator to the CC was extremely small. The TEC was able to control the CC temperature within +/-0.3K under all test conditions, and the required control heater power was less than 1W.

Ku, Jentung↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

Free-spray characteristics and spray-wall interactions of methanol on a gasoline direct injector under flash-boiling and non-flash-boiling conditions

Methanol is considered a promising alternative fuel for internal combustion engines (ICEs) due to its high-octane number, fast laminar flame speed, and elevated latent heat of vaporization, all of which support higher compression ratios and improved thermal efficiency. However, its substantial latent heat of vaporization also poses cold-start challenges, such as misfire and fuel film deposition. This study aims to investigate methanol spray morphology and spray-wall interaction using the Spray M injector from the Engine Combustion Network within a constant-pressure flow vessel. A recently developed unified numerical framework capable of modeling both flash and non-flash boiling sprays is validated against experimental liquid volume fraction data acquired via 3-D computed tomography. Here, the results reveal that flash boiling significantly alters the spray morphology, leading to smaller droplets and spray collapse due to enhanced air-entrainment-induced turbulence. Quantitative agreement between experiments and simulations confirms this behavior. Coupled 0-D equilibrium and 3-D computational fluid dynamics analyses show that flash boiling accelerates evaporation and reduces fuel residence time, while non-flash conditions maintain a persistent liquid core more susceptible to wall wetting. Wall temperature diagnostics reveal that spray collapse alters heat transfer patterns by shifting cooling effects. Mixture fraction analysis indicates that evaporation is primarily governed by shear-layer turbulence, though deviations from adiabatic equilibrium mixing emerge under low-turbulence conditions. Finally, increasing fuel, ambient, and wall temperatures reduces wall wetting and film thickness, mitigating cold-start risks. These findings enhance the understanding of methanol sprays’ behavior and support its adoption as a viable, alternative fuel for ICEs.

Engine Combustion Network↗

Sequentially evaporated thin Y-Ba-Co-O superconducting films on microwave substrates

The development of high T sub c superconducting thin films on various microwave substrates is of major interest in space electronic systems. Thin films of YBa2Cu3O(7-Delta) were formed on SrTiO3, MgO, ZrO2 coated Al2O3, and LaAlO3 substrates by multi-layer sequential evaporation and subsequent annealing in oxygen. The technique allows controlled deposition of Cu, BaF2 and Y layers, as well as the ZrO buffer layers, to achieve reproducibility for microwave circuit fabrication. The three layer structure of Cu/BaF2/Y is repeated a minimum of four times. The films were annealed in an ambient of oxygen bubbled through water at temperatures between 850 C and 900 C followed by slow cooling (-2 C/minute) to 450 C, a low temperature anneal, and slow cooling to room temperature. Annealing times ranged from 15 minutes to 5 hrs. at high temperature and 0 to 6 hr. at 450 C. Silver contacts for four probe electrical measurements were formed by evaporation followed with an anneal at 500 C. The films were characterized by resistance-temperature measurements, energy dispersive X-ray spectroscopy, X-ray diffraction, and scanning electron microscopy. Critical transition temperatures ranged from 30 K to 87 K as a function of the substrate, composition of the film, thicknesses of the layers, and annealing conditions. Microwave ring resonator circuits were also patterned on these MgO and LaAlO3 substrates.

Valco, G. J.↗

A numerical investigation of severe thunderstorm gust fronts

A numerical model was developed to simulate the evolution and structure of severe thunderstorm gust fronts. The model is a non-hydrostatic, fine resolution, cross-sectional primitive equation model. Two-dimensional horizontal and vertical equations of motion, the continuity equation, and the thermodynamic energy equation were utilized. It was shown that two dominant factors influencing gust front configuration are surface friction and the solenoidal field coincident with the front. It is suggested that solenoidal accelerations oppose the deceleration of surface friction. After a downdraft is initiated in the model, these opposing tendencies soon reach a balance and the gust front achieves a quasi-steady configuration. Thus, the experiments indicate that surface friction does not induce a cycle of front formation and collapse. In addition, the effect of evaporative cooling in producing a vigorous downdraft was parameterized by a local cooling function. Greater cooling in the downdraft results in a more intense gust front that exhibits stronger wind maximums and greater shears. The ambient air stability was shown to be an important factor influencing the depth of the cold outflow.

Mitchell, K. E.↗

Experimentally Determined Heat Transfer Coefficients for Spacesuit Liquid Cooled Garments

A Human-In-The-Loop (HITL) Portable Life Support System 2.0 (PLSS 2.0) test has been conducted at NASA Johnson Space Center in the PLSS Development Laboratory from October 27, 2014 to December 19, 2014. These closed-loop tests of the PLSS 2.0 system integrated with human subjects in the Mark III Suit at 3.7 psi to 4.3 psi above ambient pressure performing treadmill exercise at various metabolic rates from standing rest to 3000 BTU/hr (880 W). The bulk of the PLSS 2.0 was at ambient pressure but effluent water vapor from the Spacesuit Water Membrane Evaporator (SWME) and the Auxiliary Membrane Evaporator (Mini-ME), and effluent carbon dioxide from the Rapid Cycle Amine (RCA) were ported to vacuum to test performance of these components in flight-like conditions. One of the objectives of this test was to determine the heat transfer coefficient (UA) of the Liquid Cooling Garment (LCG). The UA, an important factor for modeling the heat rejection of an LCG, was determined in a variety of conditions by varying inlet water temperature, flowrate, and metabolic rate. Three LCG configurations were tested: the Extravehicular Mobility Unit (EMU) LCG, the Oceaneering Space Systems (OSS) LCG, and the OSS auxiliary LCG. Other factors influencing accurate UA determination, such as overall heat balance, LCG fit, and the skin temperature measurement, will also be discussed.

Bue, Grant↗

CONDENSATION-EVAPORATION MODELING OF DRIFT FROM A MECHANICAL COOLING TOWER

Numerical studyfor investigatingthe phase change behavior of a drift from a mechanical draft cooling tower is presented. A k-ε turbulence model, discrete phase model, species transport equations, and a heat-mass exchange model are solved simultaneouslyto capture the heat and mass transfer effects of a drift condensing and evaporatingeffects. The simulation result is compared to an available real scale test data and its limitation is also discussed. A parametric study is carried out by varying the ambient dry bulb temperature, ambient relative humidity, wind speed, liquid droplet diameter, and the drift amount. It is found that by combining the evaporation and condensation models, a drift phase change phenomena is accurately depicted. A parametric study reveals that wind speed impact is affected by the ambient temperature and the number of liquid droplets and their size play a critical role in the phase change phen

Han, Kai↗

Experimentally Determined Overall Heat Transfer Coefficients for Spacesuit Liquid Cooled Garments

A Human-In-The-Loop (HITL) Portable Life Support System 2.0 (PLSS 2.0) test has been conducted at NASA Johnson Space Center in the PLSS Development Laboratory from October 27, 2014 to December 19, 2014. These closed-loop tests of the PLSS 2.0 system integrated with human subjects in the Mark III Suit at 3.7 psi to 4.3 psi above ambient pressure performing treadmill exercise at various metabolic rates from standing rest to 3000 BTU/hr (880 W). The bulk of the PLSS 2.0 was at ambient pressure but effluent water vapor from the Spacesuit Water Membrane Evaporator (SWME) and the Auxiliary Membrane Evaporator (Mini-ME), and effluent carbon dioxide from the Rapid Cycle Amine (RCA) were ported to vacuum to test performance of these components in flight-like conditions. One of the objectives of this test was to determine the overall heat transfer coefficient (UA) of the Liquid Cooling Garment (LCG). The UA, an important factor for modeling the heat rejection of an LCG, was determined in a variety of conditions by varying inlet water temperature, flow rate, and metabolic rate. Three LCG configurations were tested: the Extravehicular Mobility Unit (EMU) LCG, the Oceaneering Space Systems (OSS) LCG, and the OSS auxiliary LCG. Other factors influencing accurate UA determination, such as overall heat balance, LCG fit, and the skin temperature measurement, will also be discussed.

Bue, Grant↗

The geometry and physical properties of exhaust clouds generated during the static firing of S-1C and S-2 rocket engines

An experimental program was conducted during the static firing of the S-1C stage 13, 14, and 15 rocket engines and the S-2 stage 13, 14, and 15 rocket engines. The data compiled during the experimental program consisted of photographic recordings of the time-dependent growth and diffusion of the exhaust clouds, the collection of meteorological data in the ambient atmosphere, and the acquisition of data on the physical structure of the exhaust clouds which were obtained by flying instrumented aircraft through the clouds. A new technique was developed to verify the previous measurements of evaporation and entrainment of blast deflector cooling water into the cloud. The results of the experimental program indicate that at the lower altitudes the rocket exhaust cloud or plume closely resembles a free-jet type of flow. At the upper altitudes, where the cloud is approaching an equilibrium condition, structure is very similar to a natural cumulus cloud.

Forbes, R. E.↗

Comparative analysis of thermal management systems in electric vehicles at extreme weather conditions: Case study on Nissan Leaf 2019 Plus, Chevrolet Bolt 2020 and Tesla Model 3 2020

With the surge in electric vehicle (EV) adoption and the need for extended driving ranges, optimizing energy efficiency, particularly through thermal management, is critical, especially in extreme weather. Managing the substantial energy needed for cabin climate control and battery temperature regulation can increase energy demands by over 50 %, severely limiting range. This study conducts a comparative analysis of thermal management systems (TMS) in three popular EV vehicles, 2020 Chevrolet Bolt, 2019 Nissan Leaf Plus, and 2020 Tesla Model 3, evaluating their distinct TMS configurations and performance under varied weather conditions. Using both numerical simulations and experimental data collected on a controlled test bench at Argonne National Laboratory, we assess how TMS architecture and operational modes influence energy consumption and range. A comprehensive TMS model was developed, integrating cabin and battery thermal sub-models in the Autonomie software platform, to simulate temperature fluctuations and range impacts. Cabin climate was modeled using a mono-zonal approach, while battery cell temperature distribution was estimated through a 2D nodal structure. Each vehicle's distinct TMS setup was evaluated: the Chevrolet Bolt and Tesla Model 3 use a dual evaporator vapor compression cycle with a PTC heater for the cabin and a coolant loop for battery thermal management; the Nissan Leaf Plus employs a heat pump with a PTC heater for the cabin and air-cooling for the battery. Tests conducted at ambient temperatures of 35°C, 22°C, -7°C, and -18°C reveal significant differences in energy use and range reduction across both configurations and conditions. At 35°C, the Tesla Model 3, Chevrolet Bolt, and Nissan Leaf Plus have a range reduction of 8%, 9%, and 13%, respectively, due to air conditioning. In winter, heating technology is paramount; at -7°C, the Nissan Leaf's heat pump configuration achieves a lower range reduction (19.3%) compared to the Tesla and Chevrolet Bolt PTC heaters, which reduce range by 28.3% and 31%, respectively. Further, this study provides valuable insights for automotive engineers, EV technology researchers, and thermal management system designers aiming to enhance electric vehicle performance by understanding how different weather conditions and TMS architectures impact energy consumption and driving range.

33 ADVANCED PROPULSION SYSTEMS↗

Composition of interstellar clouds in the disk and halo. 2: Gamma(sup 2) Velorum

High-resolution observations of gamma(sup 2) Vel with the Goddard High-Resolution Spectrograph (GHRS) echelle on the Hubble Space Telescope reveal the presence of seven narrow absorption components, with LSR velocities between -23 and +9 km s(exp -1). Three of these show column density ratios N(S(++))/N(S(+)) and N(P(++))/N(P+)) of about 1 or more, and can be identified as H II regions, while the other four are H I regions, consistent with the O I profile and with the overall H(sup 0) column density of 5.9 x 10(exp 19) cm(exp -2), given the usual assumptions that S is undepleted while O has a depletion D(O) = -0.3 dex. The depletions of Fe, Si, and Mn, which could be measure accurately for two of the four H I regions (components 6 and 7), differ somewhat from the values of D(sub ws) found for slowly moving warm clouds in HD 93521; in particular, for the component at 4.0 km s(exp -1) (No. 6), abosolute of D exceeds absolute of D(sub ws) by 0.1-0.4 dex, while for that at 9.3 km s(exp -1) (No. 7), absolute of D equals absolute of D(sub ws) on the average. The observed ratio of Fe + Mg atoms to Si atoms in the grains of component 6 is 2.04 +/-0.10, consistent with an olivine grain composition; the Fe/Mg ratio is 1.5 +/- 0.2. The electron density in component 6, determined from the C II(sup *) feature, is 0.075 +/- 0.013 cm (exp -3), about two-thirds of that found for clouds of this velocity in HD 93521. In the two conspicuous H II regions, components 3 and 4, n(sub e), determined from the Si II(sup *) feature, is about 1 cm(exp -3). From the column density of S(+) + S(++) in these two components, the total H II path length is about 40 pc. With the radius of a wind-blown bubble around gamma(sup 2) Vel set equal to 60 pc, the effective Stromgren radius is about 100 pc, requiring that T approx. equal to 50,000 K for the Wolf-Rayet component of the gamma(sup 2) Vel binary. Since zeta Pup is a comparable source of ionizing radiation, this temperature is an upper limit. The profiles of the strongest H2 absorption features, from Copernicus archives, indicate that the absorbing molecules have a mean velocity identical with that of the strongest H II component (No. 4). We have no explanation for the possible presence of these H2 molecules in a region of ionized H. Alternatively, the H2 profiles can be explained by molecules in the two adjacent (in velocity) H I regions, components 2 and 5, provided their H I gas has densities and temperatures typical of normal cold clouds. The GHRS data show absorption by highly ionized atoms Si(3+) and C(3+), N(4+) in broad features, in addition to the narrow-line absorption by Si(3+) and C(3+) observed in the dominant H II components, Nos. 3 and 4. The broad C(3+) and N(4+) features have widths corresponding to T in the range (4-8) x 10(exp 5) K, consistent with the broad O(5+) line shown in Copernicus data. Despite some observational uncertainties, the ratios of column densities in the broad C(3+), N(4+), and O(5+) features agree to +/- 0.1 dex with theoretical values for warm gas, heating and evaporating by thermal conduction from an adjacent hot region. Outward evaporation from an isolated cloud in a hot ambient gas cannot be distinguished, on the basis of these data, from inward evaporation of a warm shell, compressed by an expanding, hot stellar-wind bubble. For several halo stars, the C IV/O VI ratio has a quite different average value, perhaps consistent with cooling of infalling hot gas instead of conductive heating and evaporation.

Fitzpatrick, Edward L.↗

Thermal Performance of a Multi-Evaporator Loop Heat Pipe with Thermal Masses and Thermoelectric Coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermoelectric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of the condensers is fully utilized. Ammonia was used as the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 10W even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/- 0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5 ) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

Ku, Jen-Tung↗

Capillary Pumped Loop 3 Flight Experiment Overview

The Capillary Pumped Loop 3 (CAPL 3) Experiment is a follow on to the CAPL 1 and CAPL 2 experiments which flew on STS-60 (2/94) and STS-69 (9/95), respectively. CAPL 3 is tentatively scheduled to fly on the Space Shuttle in late 2000 as part of the Hitchhiker Experiments Advancing Technology (HEAT) payload. The experiment is a joint Naval Research Laboratory (NRL)/Goddard Space Flight Center (GSFC) payload which will meet technology objectives for both the Department of Defense and NASA. The primary objective of CAPL 3 is to demonstrate in space a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and at least 50% heat load sharing with hardware for a deployable radiator. CAPL 3 is a full scale CPL system with four parallel capillary evaporators. The loop also contains a capillary starter pump, 8 parallel direct condensation condensers with associated flow regulators, a back pressure regulator, a two-phase reservoir, and various headers and transport tubing. A variable conductance heat pipe is located between one of the evaporators and the experiment radiator to provide a cooling source for the demonstration of heat load sharing. The experiment has an operating power range of 100 W to approximately 1400 W. The experiment ammonia charge will cause it to transition to a fixed conductance mode of operation if the radiator usage reaches 85%. Ambient functional tests have been performed on the experiment. Tests performed included start-up, low power, power cycles, high power, heat load sharing, variable/fixed conductance transition, saturation temperature changes, and pressure primes while the system was operating. The majority of the testing was performed at an ammonia saturation temperature of 30C, but a few tests were done at temperatures above and below this. The testing was highly successful. Details of the tests performed and a discussion of the results will be given in the presentation.

Ottenstein, Laura↗

Thermal performance of a multi-evaporator loop heat pipe with thermal masses and thermal electrical coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermal electric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of condenser is fully utilized. Ammonia was used ad the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 1OW even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/-0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing the orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

loop heat pipes↗

Site Ambient Temperatures and Operating Schedules for EIC - Utility CW Considerations

The heat dissipated by the EIC accelerator system and components is ultimately removed by the conventional water-cooling systems that will be ultimately dissipated the waste heat to the atmosphere. An estimated 45 MW of heat will be dissipated to water during full beam operation and that will need to be effectively rejected to the atmosphere. Approximately 50% of the heat is required to be rejected to a low temperature heat sink that cannot be achieved by an evaporative cooling tower during summer. To operate during these summer months, a secondary chilled water refrigeration system will be required that would increase the cost of the cooling water system. Further, operating chiller compressor in the summer months will increase the energy consumption of the machine. This analysis is being prepared to evaluate the impact on operating and capital costs on the cooling system for various summer operating schedules while utilizing the most cost-effective scenario of an evaporative cooling system. The technology selection for the various heat sinks is addressed in a separate write-up and are not expected to change the conclusions of this write-up.

43 PARTICLE ACCELERATORS↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Possible Influences of Air Pollution, Dust and Sandstorms on the Indian Monsoon

In Asian monsoon countries, such as China and India, human health and safety problems caused by air pollution are becoming increasingly serious, due to the increased loading of atmospheric pollutants from waste gas emissions and from rising energy demand associated with the rapid pace of industrialization and modernization. Meanwhile, uneven distribution of monsoon rain associated with flash floods or prolonged drought, has caused major loss of human life and damage to crops and.property with devastating societal impacts. Historically, air-pollution and monsoons research are treated as separate problems. However recent studies have suggested that the two problems may be intrinsically linked and need to be studied jointly. Fundamentally, aerosols can affect precipitation through radiative effects cif suspended particles in the atmosphere (direct effect) and/or by interfering and changing: the cloud and precipitation formation processes (indirect effect). Based on their optical properties, aerosols can be classified into two types.: those that absorb solar radiation, and those that do not. Both types of aerosols scatter sunlight and reduce the amount of solar radiation from reaching the Earth's surface, causing it to cool. The surface cooling increases atmospheric stability and reduces convection potential, Absorbing aerosols, however, in addition to cooling the surface, can heat the atmosphere. The heating of the atmosphere may reduce the amount of low clouds by increased evaporation in cloud drops. The heating, however, may induce rising motion, enhance low-level moisture, convergence and, hence, increases rainfall, The latent heating from enhanced rainfall may excite feedback processes in the large-scale circulation, further amplify.the initial response to aerosol heating and producing more rain. Additionally, aerosols can increase the concentration of cloud condensation nuclei (CCN), increase cloud amount and decrease coalescence and collision rates, leading to reduced precipitation. However, in the presence of increasing moist and warm air, the reduced coalescence/collision may lead to supercooled drops at higher altitudes where ice precipitation falls and melts. The latent heat release from freezing aloft and melting below implies greater upward heat transport in polluted clouds and invigorate deep convection. In this way, aerosols may lead to increased local convection. Hence, depending on the ambient large-scale conditions and dynamical feedback processes, aerosols' effect on precipitation can be positive, negative or mixed. In the Asian monsoon and adjacent regions, the aerosol forcing and responses of the water cycle are even more complex, Both direct and indirect effects may take place locally and simultaneously, interacting with each other. in addition to local effects, monsoon rainfall may be affected by aerosols transported from other regions and intensified through large-scale circulation and moisture feedback. Thus, dust transported by the large-scale circulation from the adjacent deserts to northern India may affect rainfall over the Bay of Bengal; sulphate and black carbon front industrial pollution in central, southern China and northern India may affect the rainfall regime over the Korean peninsula and Japan; organic and black carbon front biomass burning from Indo-China may modulate the pre-monsoon rainfall regime over southern China and coastal regions, contributing to variability in differential heating and cooling of the atmosphere and to the land-sea thermal contrast. During the pre-monsoon season and monsoon breaks, it has been suggested that radiative forcing by absorbing aerosols have nearly the same order of magnitude as the forcing due to latent heating from convection and surface fluxes. The magnitude of the total aerosol radiative cooling due to sulphates and soot is of the order of 20-40 W/m2 over the Asian monsoon land region in the pre-monsoon season, compared to about 1-2 W/m2 for global warng. However, the combined forcing at the surface and in the atmosphere, including all species. if aerosols, and details of aerosol mixing, and impacts on the energy and water cycles in the monsoon land regions, are not well known.

Lau, William K. M.↗

Start-up Behavior of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

This paper presents the test results on start-up behaviors of a miniature loop heat pipe (MLHP) with two evaporators and two condensers. The MLHP start-up tests were conducted by varying the heat load to one or both evaporators, the condenser sink temperatures, and with or without compensation chamber (CC) temperature control. More than 90 start-up tests have been conducted in horizontal position, and all were successful. Test results showed robust start-ups of the MLHP with heat loads of 1W to 100W. Loop started as soon as the heat load was applied, without a large temperature overshoot. The efficacy and good repeatability of the start-ups with CC active temperature control by using thermoelectric cooler (TEC) was demonstrated. The ability of the loop to start with parasitic heat gain caused by cooling the CC temperature below ambient temperature was also demonstrated.

Nagano, Hosei↗